Physical Properties of Photosynthetic Cyanobacteria Applied Porous Concrete by CO2 Sequestration (광합성 남세균을 도포한 투수 콘크리트의 이산화탄소 고정에 의한 물성 변화)

  • Indong Jang;Namkon Lee;Jung-Jun Park;Jong-Won Kwark;Hoon Moon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.416-424
    • /
    • 2023
  • Concrete emits a large amount of carbon dioxide throughout its life cycle, and due to the societal demand for carbon dioxide reduction, research on storing carbon dioxide in concrete in the form of minerals is ongoing. In this study, cyanobacteria, which absorb carbon dioxide through photosynthesis and fix it as calcium carbonate, were applied to a porous concrete substrate, and the changes in the properties of the concrete substrate due to their special environmental curing condition were analyzed. The results showed that the calcium carbonate precipitation by the microorganisms was concentrated in the light-exposed surface area, and most of the precipitation occurred in the cement paste part, not in the aggregate. This microbially induced calcium carbonate precipitation enhanced the mechanical performance of the paste and improved the overall compressive strength as the curing age progressed. In addition, the increase in microbial biofilm and calcium carbonate improved the pore structure, which influenced the reduction in water permeability.

On Pattern of Birth and Death in Seoul City (서울시인구(市人口)의 출생(出生).사망(死亡) 양상(樣相)에 관(關)한 연구(硏究))

  • Kwon, E-Hyock;Kim, Tae-Ryong;Park, Hyung-Jong;Koo, Do-Suo;Lee, Yong-Wook;Park, Soon-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.1 no.1
    • /
    • pp.9-23
    • /
    • 1968
  • A survey was conducted by the staff of the College of Medicine and School of Public Health, Seoul National University in cooperation with Seoul Special City from 1 December 1967 through 28 February 1968, on such events as delivery, death, abortion and pregnancy. The survey directed to a total population of 47,811 residing in 9,157 households led us to the following findings: 1. Two year averages of crude birth rate, crude death rate and natural increase rate were 30.1, 5.6 and 24.5, respectively. 2. Of all deliveries, home and hospital deliveries constituted 61.1 per cent and 35.5 per cent, respectively. 3. Deliveries other than hospital deliveries were found to be attended more often by mother-in-laws (26.5 per cent) than by doctors or midwives(23.4 per cent). 4. About 51 per cent of all women having experiences in pregnancy during the last two years had an experience of consulting a doctor at least one time throughout whole period of pregnancy. 5. In most cases scissors were used to cut umbilical cords, of which 71.0 per cent were not sterilized and only 20.3 per cent sterilized. 6. In many cases placenta was incinerated(48.2 per cent) and on many other occasions it was thrown away into water(28.3 per cent). 7. Cement bags(37.4 per cent), gauze and absorbent cotton(29.8 per cent) were found to be most frequently used to receive new-born babies. 8. In 1966 8. 8 per cent of the women had at least one abortion induced and in 1967 the percentage was 9.2 per cent. 9. Nearly all(95.8 per cent) of the induced abortions reportedly were done at doctor's clinics. 10. Of all the abortions induced 65.3 per cent were done by specialists in obstetrics, 30.3 per cent by general practitioners and 2.7 per cent by midwives. 11. Those who experienced spontaneous abortions were 1.9 per cent of all women both in 1966 and 1967. 12. About 9.2 per cent of women investigated were found to be currently pregnant. 13. Age specific death rate turned out to be highest among those under 1 year of age. 14. Ten major causes of death in their order of frequency were: 15. Places of death can be classified into homes(75.3 per cent) and hospitals(13.2 per cent). 16. Method of disposing of corpses comprised burials(54.2 per cent) and cremations(44.6 per cent). 17. Infant, neonatal and hebdomadal mortality rates have been computed at 32.2, 18.9 and 13.7, respectively. 18. Infants were found to have died either at homes(81.5 per cent) or at hospitals(18.5 per cent). 19. Birth registrations had been done for about 18.5 per cent of the dead infants.

  • PDF

EFFECT OF VARIOUS RESIN CEMENTS TO THE SHEAR BOND STRENGTH IN THE ADHESION BRIDGE (접착성가공의치에서 세멘트 종류가 전단결합강도에 미치는 영향)

  • Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.4
    • /
    • pp.791-799
    • /
    • 1996
  • The purpose of this study was to compare the shear bond strength of adhesion bridge by various resin cements. One hundred and foully 1st premolars were used. The teeth were cut below 2mm from CEJ and the coronal portions were used. The coronal portions were embeded with the acrylic resin and trimmed with sic paper until the flat plane with ${\phi}$ 4mm above acrylic resin sticks in height 5mm were casted with nonprecious metal and the using surfaces were treated with sic paper from #200 to #1200 and polished with alminum oxide paste. And then, the using surfaces were sandblasted and treated with the electrochemical etching. The teeth were divided into three groups of fourty two each. In group I, teeth and specimens were cemented with Panavia 21 In group II, teeth and specimens were cemented with Superbond In group I, teeth and specimens were cemented with All-Bond & composite resin cement Each group was subdivided into three subgroups according to the storage period ; one-day storage, fifteen-day storage, and thirty-day storage. The special jig was made. Then, the specimen and jig were mounted to Instron Universal Testing Machine and the failure were measured. The results were as follows. 1. There was statisfically significant difference between the failure loads of group I and group II and III after one day storage(P<0.01), 2. There was statisfically significant difference between the failure loads of group II and group I and III and between group I and group III at fifteen day storage(P<0.01). 3. There was statisfically significant difference between the failure loads of group I and II and group III after thirty day storage(P<0.01). 4. There was statisfically significant difference between the failure loads of one day storage and fifteen and thirty days storages in group III (P<0.01).

  • PDF

Fracture load and marginal fitness of zirconia ceramic coping by design and coloration (유색 및 백색 지르코니아 세라믹 코핑의 코핑 디자인에 따른 파절 하중과 변연 적합성)

  • Shin, Mee-Ran;Kim, Min-Jeong;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.406-415
    • /
    • 2009
  • Purpose: The purpose of this study was to compare the marginal fitness and fracture load of the zirconia copings according to the design with different thickness and coloration. Material and methods: The evaluation was based on 80 zirconia copings. Zirconia copings were fabricated in design with different thicknesses using CAD/CAM system (Everset, KAVO dental GmbH, Biberach, Germany). The designs of copings were divided into four groups. The first group consisted of copings with uniform thickness of 0.3 mm. The thickness in the second group was 0.3 mm on the buccal surface and 0.6 mm on the lingual surface. The third group consisted of coping with uniform thickness of 0.6 mm. The thickness in the fourth group was 0.6 mm on the buccal surface and 1mm on the lingual surface. Each group consisted of 10 colored and 10 uncolored copings. Half of the copings (40) processed with a milling system according to the specific design were sent to be given a color (A3) through saturation in special dye by a manufacturing company. Just after sintering, the marginal discrepancies of copings were measured on the buccal, lingual, mesial and distal surfaces of metal die, under a Video Microscope System (sv-35, Sometech, Seoul, Korea) at a magnification of $\times$ 100. It was remeasured after the adjusting of the inner surface. Next, all copings were luted to the metal dies using reinforced cement {GC FujiCEM (GC Corp. Tokyo, Japan)} and mounted on the testing jig in a Universal Testing Machine (Instron 4467, Norwood, MA, USA). The results were analyzed statistically using the one-way ANOVA test. Results: The obtained results were as follow: 1. The measured value of marginal discrepancy right after sintering was the greatest in the contraction of the buccal area in all groups, except for group I2. 2. There was no significant difference of marginal fitness among the groups in the colored zirconia group (P<.05). 3. When the marginal fitness among the groups in the uncolored zirconia group was considered, group II2 had the smallest marginal discrepancy. 4. When the colored and uncolored groups with the same design were compared, there was a significant difference between I1 and II1 groups. In group 2, 3, and 4, the uncolored zirconia had the greatest marginal fitness (P<.05). 5. After adjustment of inner surface, there was no significant difference in the marginal fitness in all groups when color and design of the zirconia coping were compared. 6. The fracture load of CAD/CAM zirconia copings showed significant difference in group 1, 2, 3, and 4. I4 and II4 had the strongest fracture load. 7. When groups with different color and same design were compared, all colored groups showed greater fracture load (P>.05), with no significance. Conclusion: There was difference in the marginal fitness according to the design and coloration of zirconia copings right after sintering, but it was decided that the copings may well be used clinically if the inner surface are adjusted. The copings should be thick enough for the reinforcement of fracture strength. But considering the esthetics of the visible surfaces (labial and buccal surface), the thickness of copings may be a little thin, without giving any significant effect on the fracture strength. This type of design may be considered when giving priority to preservation of tooth or esthetics.