• 제목/요약/키워드: Special bridge

검색결과 210건 처리시간 0.021초

리플전압을 이용한 병렬아크 사고 감지기 개발 (Development of Parallel Arc Fault Detector Using Ripple Voltage)

  • 최정규;곽동걸
    • 전력전자학회논문지
    • /
    • 제21권5호
    • /
    • pp.453-456
    • /
    • 2016
  • The major causes of electrical fire in low-voltage distribution lines are classified into short-circuit fault, overload fault, electric leakage, and electric contact failure. The special principal factor of the fire is electric arc or spark accompanied with such electric faults. This paper studies the development of an electric fire prevention system with detection and alarm of that in case of parallel arc fault occurrence in low-voltage distribution lines. The proposed system is designed on algorithm sensing the instantaneous voltage drop of line voltage at arc fault occurrence. The proposed detector has characteristics of high-speed operation responsibility and superior system reliability from composition using a large number of semiconductor devices. A new sensing control method that shows the detection of parallel arc fault is sensed to ripple voltage drop through a diode bridge full-wave rectifier at electrical accident occurrence. Some experimental tests of the proposed system also confirm the practicality and validity of the analytical results.

A Computer-Aided Inspection Planning System for On-Machine Measurement - Part I : Global Inspection Planning -

  • Lee, Hong-Hee;Cho, Myeong-Woo;Yoon, Gil-Sang;Choi, Jin-Hwa
    • Journal of Mechanical Science and Technology
    • /
    • 제18권8호
    • /
    • pp.1349-1357
    • /
    • 2004
  • Computer-Aided Inspection Planning (CAIP) is the integration bridge between CAD/CAM and Computer Aided Inspection (CAI). A CAIP system for On-Machine Measurement (OMM) is proposed to inspect the complicated mechanical parts efficiently during machining or after machining. The inspection planning consists of Global Inspection Planning (GIP) and Local Inspection Planning (LIP). In the GIP, the system creates the optimal inspection sequence of the features in a part by analyzing the various feature information such as the relationship of the features, Probe Approach Directions (PAD), etc. Feature groups are formed for effective planning, and special feature groups are determined for sequencing. The integrated process and inspection plan is generated based on the sequences of the feature groups and the features in a feature group. A series of heuristic rules are developed to accomplish it. In the LIP of Part II, the system generates inspection parameters. The integrated inspection planning is able to determine optimum manufacturing sequence for inspection and machining processes. Finally, the results are simulated and analyzed to verify the effectiveness of the proposed CAIP.

Analysis of Slot Leakage Reactance of Submersible Motor with Closed Slots during Starting Transient Operation

  • Bao, Xiaohua;Di, Chong;Fang, Yong
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.135-142
    • /
    • 2016
  • Generally, closed slots are adopted to reduce the water friction loss in both the stator and the rotor of water filling submersible motor due to the special environment of operation. One of the obvious differences between the traditional induction motors and water filling submersible motors is that the submersible motors only need relatively smaller starting torque. This paper aims to analyze the slot leakage reactance of water filling submersible motor during starting transient operation. An improved analytical method which considered the magnetic saturation of the slot bridge and the skin effect of rotor bars is proposed. The slot permeance factor which has a direct impact on the slot leakage reactance is calculated. Then finite element models with different stator slot types are constructed and search coils are introduced to measure the slot flux linkage. Moreover, the starting performances of the models with two typical stator slots are compared and the flux leakage characteristics are obtained. Finally, the results obtained by finite element method are very close to the results obtained by analytical method.

Field Circuit Coupling Optimization Design of the Main Electromagnetic Parameters of Permanent Magnet Synchronous Motor

  • Zhou, Guang-Xu;Tang, Ren-Yuan;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권1호
    • /
    • pp.88-93
    • /
    • 2008
  • The electromagnetic parameters of a permanent magnet synchronous motor (PMSM) such as the open load permanent magnet flux, d axis reactance $X_d$, and q axis reactance $X_q$, are most essential to the performance analysis and optimization design of the motor. Based on the numerical analysis of the 3D electromagnetic field, the three electromagnetic parameters of permanent magnet synchronous motors with U form interior rotor structures are calculated by FEA. The rules of the leakage coefficient and reactance parameters changing with the air gap length, permanent magnet magnetism length, and isolation magnetic bridge dimensions in the rotor are given. The calculated values agree well with the measured values. The FEA results are integrated with the self compiled electromagnetic design program to optimize the prototype motor. The tested performances of the prototype motor prove that the method is suitable for the optimization of motor structure.

Determination of plastic hinge properties for static nonlinear analysis of FRP-strengthened circular columns in bridges

  • Amiri, Gholamreza Ghodrati;Jahromi, Azadeh Jaberi;Mohebi, Benyamin
    • Computers and Concrete
    • /
    • 제10권5호
    • /
    • pp.435-455
    • /
    • 2012
  • In the recent years, rehabilitation of structures, strengthening and increasing the ductility of them under seismic loads have become so vital that many studies has been carried out on the retrofit of steel and concrete members so far. Bridge piers are very important members concerning rehabilitation, in which the plastic hinging zone is very vulnerable. Pier is usually confined by special stirrups predicted in the design procedure; moreover, fiber-reinforced polymers (FRP) jackets are used after construction to confine the pier. FRP wrapping of the piers is one of the most effective ways of increasing moment and ductility capacity of them, which has a growing application due to its relative advantages. In many earthquake-resistant bridges, reinforced concrete columns have a major defect which could be retrofitted in different ways like using FRP. After rehabilitation, it is important to check the strengthening adequacy by dynamic nonlinear analysis and precise modeling of material properties. If the plastic hinge properties are simplified for the strengthened members, as the simplified properties which FEMA 356 proposes for non-strengthened members, static nonlinear analysis could be performed more easily. Current paper involves this matter and it is intended to determine the plastic hinge properties for static nonlinear analysis of the FRP-strengthened circular columns.

새로운 열교환 방식을 이용한 유도가열 과열증기 발생장치 개발 (Development of induction heating superheater system using new heat exchanging method)

  • 설용태;이의용;권혁민
    • 한국산학기술학회논문지
    • /
    • 제10권4호
    • /
    • pp.740-746
    • /
    • 2009
  • 본 논문에서는 공진형 유도가열기를 이용한 2단 직렬 부하형 유도가열 과열증기 발생장치를 제안하였다. 발열방식은 외부의 가열코일로부터 특수 합금 발열체에 비접촉 상태로 전자유도 와전류를 구조체에 흐르게 하였다. 인버터는 풀-브리지 고주파 직렬 부하 공진형 이며, LC 공진 설계에서 부하자체를 인덕터로 선정하여 효율을 최대화 하였다. 개발된 장치는 전자유도가열 발열체와 유체이동에 의한 새로운 열교환 방식으로 일체의 연소과정 없이 기체, 액체 및 증발체 등을 상온에서 고온에 이르기까지 고정도의 가열이 가능하다.

Output-only modal parameter identification of civil engineering structures

  • Ren, Wei-Xin;Zong, Zhou-Hong
    • Structural Engineering and Mechanics
    • /
    • 제17권3_4호
    • /
    • pp.429-444
    • /
    • 2004
  • The ambient vibration measurement is a kind of output data-only dynamic testing where the traffics and winds are used as agents responsible for natural or environmental excitation. Therefore an experimental modal analysis procedure for ambient vibration testing will need to base itself on output-only data. The modal analysis involving output-only measurements presents a challenge that requires the use of special modal identification technique, which can deal with very small magnitude of ambient vibration contaminated by noise. Two complementary modal analysis methods are implemented. They are rather simple peak picking (PP) method in frequency domain and more advanced stochastic subspace identification (SSI) method in time domain. This paper presents the application of ambient vibration testing and experimental modal analysis on large civil engineering structures. A 15 storey reinforced concrete shear core building and a concrete filled steel tubular arch bridge have been chosen as two case studies. The results have shown that both techniques can identify the frequencies effectively. The stochastic subspace identification technique can detect frequencies that may possibly be missed by the peak picking method and gives a more reasonable mode shapes in most cases.

변압기 직렬구조의 EV용 승압형 양방향 ZCS DC/DC 컨버터 개발 (Development of Boost Type Bidirectional ZCS DC/DC Converter For EV of Transformer Series Construction)

  • 최정식;박병철;정동화;송성근
    • 조명전기설비학회논문지
    • /
    • 제27권11호
    • /
    • pp.37-46
    • /
    • 2013
  • This paper proposes the boost type bidirectional zero current switching(ZCS) DC/DC converter of transformer series construction for electric vehicle operation using low voltage battery. This converter can high boost through the double voltage circuit and series construction of output part using two converters. This converter system has the advantages that bidirectional power transfer is excellent, size and making of transformer because of this converter keeps the transformation ratio to 1:1. Proposed DC/DC converter uses the ZCS method to decrease the switching loss. By replacing reactance ingredients of L-C resonance circuit for ZCS with leakage inductance ingredients of high frequency transformer and half-bridge capacitor it reduces system size and expense because of not add special reactor. It can confirm to output of high voltage to operate the electric vehicle with low voltage of input and operation of ZCS in all load region through the result of PSIM simulation and experiment.

변위 시계열 데이터를 이용한 교량거더의 Flutter 계수 추정기법에 관한 연구 (A Study on the Identification Method for Flutter Derivatives of Bridge Girders using Displacement Time History Data)

  • 이재형;민원;이용재
    • 한국강구조학회 논문집
    • /
    • 제13권5호
    • /
    • pp.525-533
    • /
    • 2001
  • 교량의 내풍 안전성을 평가하기 위해서는 플러터 계수(Flutter Derivatives)의 안정적 추정이 필요하다. 본 논문에서는 풍동실험에서 얻어지는 시간영역에서의 데이터중 변위 시계열데이터를 이용해서 플러터 계수를 구하는 동특성 계수 측정기법 2가지를 검토하였다. 검토된 MITD(Modified Ibrahim Time Domain) 방법과 AKF(Adaptive Kalman Filtering) 방법은 2차원단면모형 실험으로부터 동시에 8개의 플러터 계수를 산출할 수 있는 유용한 방법이다. 제안된 방법의 실제상황에서의 적용성을 검토하기 위해서 Bandlimited Gausian white noise을 가상의 데이터에 첨가하여 수학적 시뮬레이션으로 잡음에 대한 안정성을 검증해 보았다. 그 결과 교량의 플러터 해석에서는 본 연구에서 검증된 MITD 방법을 통한 플러터 계수의 산출이 추전된다.

  • PDF

모달시험을 통한 국부 구조물 방진대책 수립 (Vibration measures for local structures through modal tests)

  • 권종현;김문수;양성붕;이원석;이봉민
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2017년도 특별논문집
    • /
    • pp.14-18
    • /
    • 2017
  • The Lashing bridge and radar mast of ship are upright structures so they are generally exposed to excessive vibration. Recently, the use of low speed main engines for improving fuel efficiency has been increasing, and the excitation frequencies of the main engine are moving to the low frequency band. If the excitation frequencies are coincident with the natural frequencies of the local structure, excessive vibration occurs during main engine operating condition. The modal test is to experimentally determine resonance frequency, mode shape, and damping, which are vibration characteristics of a mechanical structure under dynamic external force. Through this study, the vibration characteristics of the structure are obtained by modal tests and the low vibration measure is applied to the local structures.

  • PDF