• 제목/요약/키워드: Spatial resolution

검색결과 2,532건 처리시간 0.031초

Performance Evaluation of Pansharpening Algorithms for WorldView-3 Satellite Imagery

  • Kim, Gu Hyeok;Park, Nyung Hee;Choi, Seok Keun;Choi, Jae Wan
    • 한국측량학회지
    • /
    • 제34권4호
    • /
    • pp.413-423
    • /
    • 2016
  • Worldview-3 satellite sensor provides panchromatic image with high-spatial resolution and 8-band multispectral images. Therefore, an image-sharpening technique, which sharpens the spatial resolution of multispectral images by using high-spatial resolution panchromatic images, is essential for various applications of Worldview-3 images based on image interpretation and processing. The existing pansharpening algorithms tend to tradeoff between spectral distortion and spatial enhancement. In this study, we applied six pansharpening algorithms to Worldview-3 satellite imagery and assessed the quality of pansharpened images qualitatively and quantitatively. We also analyzed the effects of time lag for each multispectral band during the pansharpening process. Quantitative assessment of pansharpened images was performed by comparing ERGAS (Erreur Relative Globale Adimensionnelle de Synthèse), SAM (Spectral Angle Mapper), Q-index and sCC (spatial Correlation Coefficient) based on real data set. In experiment, quantitative results obtained by MRA (Multi-Resolution Analysis)-based algorithm were better than those by the CS (Component Substitution)-based algorithm. Nevertheless, qualitative quality of spectral information was similar to each other. In addition, images obtained by the CS-based algorithm and by division of two multispectral sensors were shaper in terms of spatial quality than those obtained by the other pansharpening algorithm. Therefore, there is a need to determine a pansharpening method for Worldview-3 images for application to remote sensing data, such as spectral and spatial information-based applications.

Recognition resolution enhancement of ultrasonic sensors via multiple steps of transmitter voltages

  • Na, Seung-You;Park, Min-Sang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 Proceedings of the Korea Automatic Control Conference, 11th (KACC); Pohang, Korea; 24-26 Oct. 1996
    • /
    • pp.409-412
    • /
    • 1996
  • Ultrasonic sensors are widely used in various applications due to advantages of low cost, simplicity in construction, mechanical robustness, and little environmental restriction in usage. But the main purposes of the noncontact sensing are rather narrowly confined within object detection and distance measurement. For the application of object recognition, ultrasonic sensors exhibit several shortcomings of poor directionality which results in low spatial resolution of objects, and specularity which gives frequent erroneous range readings. To resolve these problems in object recognition, an array of the sensor has been used. To improve the spatial resolution, more number of sensors are used in essence throughout the various devices of the sensor arrays. Under the disguise of a fixed number of the sensors, the array can be shifted mechanically in several steps. In this paper we propose a practical sensor resolution enhancement method using an electronic circuit accompanying the sensor array. The circuit changes the transmitter output voltage in several steps. Using the known sensor characteristics, a set of different return echo signals provide enhanced spatial resolution. The improvement is obtained with neither the cost of the increased number of the sensors nor extra mechanical devices.

  • PDF

기하학적 기법을 이용한 하이퍼스펙트럴 영상의 Linear Spectral Mixing모델에 관한 연구 (A Study on Linear Spectral Mixing Model for Hyperspectral Imagery with Geometric Method)

  • 장은석;김대성;김용일
    • 한국GIS학회:학술대회논문집
    • /
    • 한국GIS학회 2003년도 추계학술대회논문집
    • /
    • pp.23-29
    • /
    • 2003
  • Detection in remotely sensed images can be conducted spatially, spectrally or both [2]. If the images have high spatial resolution, materials can be detected by using spatial and spectral information, unless we can't see the object embedded in a pixel. In this paper, we intend to solve the limit of spatial resolution by using the hyperspectral image which has high spectral resolution. Therefore, the Linear Spectral Mixing(LSM) Model which is sub-pixel detection algorithm is used to solve this problem. To find class Endmembers, we applied Geometric Model with MNF(Minimum Noise Fraction) transformation. From the result of sub-pixel detection algorithm, we can see the detection of water is satisfied and the object shape cannot be extracted but the possibility of material existence can be identified.

  • PDF

Resolution analysis of Fourier Hologram using integral imaging

  • Chen, Ni;Park, Jae-Hyeung;Kim, Nam
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2009년도 창립 20주년기념 특별학술발표회
    • /
    • pp.331-332
    • /
    • 2009
  • We present an analysis on the quality factors of the Fourier hologram generated from multiple orthographic view images of three-dimensional object. In the analysis, we analyze both the maximum size of the reconstructed object and its spatial resolution. For the maximum size of the reconstruction, we found that the main factor is the orthographic projection angle interval. Too large projection angle interval causes overlapping in the reconstruction space domain. For the spatial resolution, there are three factors, i.e. the capturing lens array pitch which determines the spatial sampling rate of the original three-dimensional objects, the maximum orthographic projection angle, and the spatial frequency bandwidth of the object. The dominant factor is determined by the relationship between those three factors.

  • PDF

TEM 관련 이론해설 (6): 투과전자현미경의 고분해능 영상이론: 결맞음 (1) (Theory of High Resolution TEM Image Formation: Coherence (1))

  • 이확주
    • Applied Microscopy
    • /
    • 제35권3호
    • /
    • pp.105-112
    • /
    • 2005
  • 고분해능 TEM 영상 이론의 결맞음 조사에서의 결맞음에 관한 개념을 소개하였다. 현미경에서 부분 결맞음 파동으로 인한 transfer function과 envelope의 발생을 설명하고 현미경의 분해능과 관련된 passband와 Scherzer 초점 조건을 소개하였다.

An Approach to Fuse IKONOS Images by Wavelet Transformation

  • Zhu, Changqing;Wang, Yuhai
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.776-782
    • /
    • 2003
  • This paper develops an approach to fuse 1-meter resolution spatial panchromatic and 4-meter resolution multi-spectral IKONOS images. The approach is based on the characteristics of four-band wavelet transformation. The experiment shows that the fused images based on four-band wavelet method contain with not only high spatial resolution but also rich spectral characteristic.

  • PDF

시계열 위성영상을 위한 효과적인 Super Resolution 기법 (An Efficient Super Resolution Method for Time-Series Remotely Sensed Image)

  • 정승균;최윤수;정형섭
    • Spatial Information Research
    • /
    • 제19권1호
    • /
    • pp.29-40
    • /
    • 2011
  • 정지궤도 해색 센서(GOCI: Geostationary Ocean Color Imager) 는 세계 최초의 정지궤도 위성으로 매일 1 시간마다 8 장의 영상을 획득 할 수 있어 육상파 해양 모두 활용성이 높은 위성이다. 그러나 500m의 GSD(Ground Sample Distance)를 지니는 서해성도 영상은 육성 활용에 한계가 있다. 최근, 컴퓨터 비전분야에서 활발히 진행 중인 기술인 Super Resolution(이하 SR)는 유사 시간대에 촬영한 저해상도 영상으로부터 고해상도 영상을 제작하는 기술로, 이를 시간 해상도가 높은 시계열 위성인 GOCI에 적용한다면 해상도가 향상 된 영상을 제작하는 기술로, 이를 시간 해상도가 높은 시계열 위성인 GOCI에 적용한다면 해상도가 향상 된 영상의 취득이 가능하며, 또한 광학 위성 영상의 단점인 구름에 의해 손실된 지상 정보의 복원이 가능할 것이다. 본 연구에서는, GOCI 자료를 위한 효율적인 초해상도 영상 복원 알고리즘 개발을 위한 선행연구로써 위성 영상 취득과정과 유사한 환경의 시뮬레이션을 통해 시계열 자료를 제작하고, 제작된 자료를 제안한 알고리즘에 적용함으로서 0.1 단위의 픽셀 정합도를 확인하였고, 원본 영상과 RMSE 0.5763, PSNR 52.9183 db, SSIM Index 0.9486의 정확도를 나타낸 HR 영상을 복원하였다.

Onco Flash에서 매개변수 변화에 따른 영상의 질 평가 (Evaluation of Image Quality by Parameter Change in Onco Flash)

  • 차은선;노익상;김기;최춘기;석재동
    • 핵의학기술
    • /
    • 제13권1호
    • /
    • pp.30-34
    • /
    • 2009
  • 목적 : 현재 신속한 검사 및 환자의 대기 시간 단축에 따른 제한적인 영향을 가지고 있는 whole body bone scan의 단점을 보완하기 위한 다양한 프로그램들이 개발되어 사용되고 있다. 본 연구는 스캔속도와 알파 값에 따른 FWHM를 이용하고 영상의 육안평가를 통해서 우수한 영상의 질을 얻을 수 있는 매개변수로 임상의 유용성을 얻고자 한다. 실험재료 및 방법 : Siemens (e.cam)사의 감마카메라에서 spatial resolution phantom과 four quadrant bar phantom을 이용하였다. spatial resolution phantom을 가지고 scatter와 non scatter로 Onco Flash를 적용해서 스캔속도 15, 20, 25, 30, 35, 40 cm/min으로 FWHM을 비교하였다. 또한 Onco Flash의 알파값 (0~100%)에서 10%씩 증가하여 스캔속도 30 cm/min 기준으로 계수율과 bar phantom 영상을 얻어 육안적 평가를 하였다. 결과 : Onco Flash를 적용한 scatter에서 스캔속도에 따라 FWHM은 9.37, 9.40, 9.28, 9.30, 9.31, 9.53 mm이고, non scatter에서는 스캔속도에 따라 FWHM은 8.42, 8.32, 8.2, 8.25, 8.35, 8.52 mm이었다. 알파 값은 10%씩 증가할수록 계수율도 증가하고, 육안적 평가는 40% 이상에서 인공물이 나타나기 시작하기 때문에 알파 값은 30% 이하에서 적합하였다. 따라서 Onco Flash를 사용한 스캔속도가 25~35 cm/min에서 알파값 30% 적용 시 FWHM이 평균 9.3 mm로서 15~40 cm/min를 벗어나는 값 보다 공간분해능이 향상되었다. 결론 : Whole body bone scan의 영상을 향상시킬 수 있는 적정 매개변수를 알 수 있었으며 검사 시간을 단축하면서 영상의 질을 향상 할 수 있도록 매개변수들을 적용해 보아 임상적용에 적합한 범위를 얻어 검사자에게 유용한 지표가 될 것이라 사료된다.

  • PDF

시각적 기법에 의한 DMC/UlatraCamXp/ADS80 디지털 항공영상의 공간해상도 특성 분석 (Analysis of Spatial Resolution Characteristics for DMC/UlatraCamXp/ADS80 Digital Aerial Image Based on Visual Method)

  • 이태윤;이재원
    • 대한공간정보학회지
    • /
    • 제24권1호
    • /
    • pp.61-68
    • /
    • 2016
  • 최근 디지털 항공영상은 우수한 촬영기하와 높은 공간 및 방사해상도로 인하여 대축척 지도제작에 보편적으로 활용되고 있다. 하지만 제작된 결과물에 대한 높은 정밀도와 신뢰도의 확보를 위해서는 촬영된 영상의 품질검증 작업이 선행되어야 한다. 국외에서는 영구적인 항공카메라 검정용 테스트베드를 구축하여 영상취득 시스템을 검증하는 실험적 연구가 활발히 진행되고 있다. 반면 국내에서는 아직 관련 분야에 관한 연구와 실험이 미흡하여 영상의 품질검증을 위한 실용적인 방안의 제시가 절실한 실정이다. 따라서 본 연구에서는 휴대용 Siemens star 타겟을 이용하여 시각적인 방법으로 손쉽게 영상의 공간해상도를 측정하는 방법을 제시하고자 하였다. 본 연구에 이용된 영상은 면형 방식의 DMC, UltraCamXp와 선형방식의 ADS80 등 세 종류의 카메라로 취득하였다. 촬영된 영상에서 Siemens star 타겟을 추출하여 시각적인 방법으로 영상의 해상도를 이론적인 GSD(Ground Sample Distance)와 비교하였다. 아울러 Siemens star 타겟이 촬영된 영상의 위치와 비행방향 및 비행직각 방향에 따라 공간해상도의 변화를 비교 분석하였다. 본 연구의 결과, 카메라별 촬영된 영상의 이론적 GSD는 약 6~9cm인 반면, 시각적 해상도는 이론적인 GSD에 비하여 약 1.2~1.3배 정도 크게 측정됨을 알 수 있었다.