High levels of ambient noise and safety factors often limit the use of 'active-source' seismic methods for geotechnical investigations in urban environments. As an alternative, shear-wave velocity-depth profiles can be obtained by treating the background microtremor wave field as a stochastic process, rather than adopting the traditional approach of calculating velocity based on ray path geometry from a known source. A recent field test in Melbourne demonstrates the ability of the microtremor method, using only Rayleigh waves, to resolve a velocity inversion resulting from the presence of a hard, 12 m thick basalt flow overlying 25 m of softer alluvial sediments and weathered mudstone. Normally the presence of the weaker underlying sediments would lead to an ambiguous or incorrect interpretation with conventional seismic refraction methods. However, this layer of sediments is resolved by the microtremor method, and its inclusion is required in one-dimensional layered-earth modelling in order to reproduce the Rayleigh-wave coherency spectra computed from observed seismic noise records. Nearby borehole data provided both a guide for interpretation and a confirmation of the usefulness of the passive Rayleigh-wave microtremor method. Sensitivity analyses of resolvable modelling parameters demonstrate that estimates of shear velocities and layer thicknesses are accurate to within approximately $10\%\;to\;20\%$ using the spatial autocorrelation (SPAC) technique. Improved accuracy can be obtained by constraining shear velocities and/or layer thicknesses using independent site knowledge. Although there exists potential for ambiguity due to velocity-thickness equivalence, the microtremor method has significant potential as a site investigation tool in situations where the use of traditional seismic methods is limited.
Park, Cheol Woo;Lee, Changho;Lim, SooHee;Ni, Aleksey;An, Jin Hyo;Lee, Ho;Bae, Jae Sung;Kim, Jeehyun
Journal of the Optical Society of Korea
/
v.16
no.2
/
pp.174-180
/
2012
In this study, the feasibility of spectral domain optical Doppler tomography for measuring blood flow characteristics in a micro-tube was demonstrated through several experiments. The use of an SD-ODT system in blood flow measurement can provide high resolution images (5 microns resolution). We prepared three capillary tubes to reveal the effect of different concentrations of hematocrit ratio (HR). One tube serves as the control. The two other tubes contained different concentrations of HR (5%, 25%). Three different capillary tube inlet flow velocities were tested in the present study. The Reynolds number (Re) which is based on the capillary tube inner diameter ranges from Re=6 to 48. We calculated a Doppler shift of the power spectrum of the temporal interference fringes with Kasai autocorrelation function to achieve the velocity profile of the flow. As a result, SD-ODT systems could not detect the cell depletion layer in the present study due to the limitation of spatial resolution. Nevertheless, these systems were proven to be capable of observing the RBCs of blood.
The Leadership in Energy and Environmental Design (LEED) has provided abundant resources and guidelines for a new project to become a sustainable anchor in the neighborhood. Paired with a range of checklist, LEED has strong influence on the standards for a sustainable building, and it also has played an iconic role in energy-efficient architecture. However, it is still unclear as to whether or not an LEED certified building enhances environmental benefits to its surroundings. If an LEED certification promises a baseline for an eco-friendly building, then a group of these structures should ensure significant environmental benefits to the society. This is the main question of this study, and the authors answer this hypothesis by examining the relationship of LEED certificates and their influence on outdoor temperature, especially in terms of urban heat island effect. The goal of this paper is to analyze the influence of the LEED certification on urban temperature as an indicator of sustainable architecture's regional interactions. If an LEED certificate is regarded as a strong contributor to a sustainable built environment, then a group of these certificates should result in greater benefits to society. To this extent, the authors question if there is any possible relationship between a large concentration of LEED certified sites and the temperature of their surroundings. To properly assess the research direction, Global Moran's I analysis, Local Moran's I analysis, and Hot Spot analysis are implemented to find the clustered areas of LEED certified buildings. For examining relationships between clustered area and its temperature, correlation efficients are calculated.
Proceedings of the Plant Resources Society of Korea Conference
/
2019.10a
/
pp.27-27
/
2019
본 연구는 멸종위기 아고산수종 구상나무의 보존 복원을 위한 유전다양성을 고려한 표본추출전략을 구명하는데 그 목적이 있다. 2019년 9월에 한라산 영실 집단($14,000m^2$)에서 총 152개체를 대상으로 선발된 10개의 nSSR 마커를 이용하여 유전다양성 및 공간적 유전구조를 분석하였다. 평균 유전다양성은 관찰된 대립유전자수(A)가 7.2개, 유효대립유전자수($A_e$)가 3.6개, 이형접합도 관찰치($H_o$)가 0.528, 이형접합도 기대치($H_e$)가 0.595이며, 고정지수(F)는 0.071 이었다. 조사구내 구상나무 성목 152개체는 평균 수고 3.6 m, 흉고직경 17.3 cm로 나타났다. 구상나무의 개체목간 평균거리는 3.94 m, 임분밀도는 700 본/ha 이며 개체의 공간적 분포는 임의분포 형태로 나타났다. 구상나무의 유전변이에 대한 공간적 자기상관성(spatial autocorrelation) 분석 결과, 조사구의 구상나무는 약 15 m 이내에서 분포하는 개체들 간 유전적 유사성이 있게 분포하는 것으로 나타났으며 임분밀도가 높고 수고가 낮은 특성으로 인하여 비교적 작은 유전군락이 형성된 것으로 사료된다. 결과적으로 영실의 구상나무 집단의 보존 복원을 위한 표본추출전략은 15 m의 간격을 두고 개체를 선발하는 것이 타당한 것으로 나타났다.
KSCE Journal of Civil and Environmental Engineering Research
/
v.29
no.4D
/
pp.443-450
/
2009
Uninterrupted facility - since there is a close relationship between traffic volume, speed and density -, when a ramp traffic flow merges into the main line, will change the traffic speed or density, and the corresponding correlational model equation will be changed. Thus, this study, using time and space-series traffic data on areas under the influence of such a merging, identified sections which changed the correlation between speed and density variables, and examined such changes. As a result, the upstream and merging sections showed the "Underwood"-shaped exponent, and the downstream after passing the merging section showed a straight line "Greenshields" model. The downstream section which changed the correlation between speed and density showed a gradual downstream movement phenomenon within 100 m-500 m from the end of the third lane linking with the ramp, as the traffic approached the inner lanes. Also, the upstream section, merging section, and downstream section involving a change showed heterogeneous traffic flows which, in the speed-density model, have a statistically different free flow speed (constant) and a different ratio of free flow speed to jam density (gradient).
Apartments constitute 64% of the housing type composition, representing the highest proportion among housing types. This proportion has been increasing annually. Given this trend, apartment prices are likely to have a significant impact on the national economy and people's livelihoods. This study examines the impact of the recent development of Seodaegu Station on the surrounding apartment market, with a specific focus on the effects of the educational environment. To this end, we conduct empirical analysis employing a hedonic price model and spatial autocorrelation analysis, based on actual transaction price data from the Ministry of Land, Infrastructure, and Transport. The study revealed three key findings: first, the development of Seodaegu Station positively impacted apartment prices. Second, this positive effect increases with the proximity to Seodaegu Station. Third, the enhancement of the educational environment nearby the Seodaegu Station development also positively influenced apartment prices. This study aims to serve as baseline research output for the public management of future metropolitan transportation facility development projects and for predicting apartment price trends.
To reveal and classify site characteristics in densely populated areas in Chuncheon, Korea, Rayleigh-waves were recorded at 50 sites including four sites in the forest area using four 1-Hz velocity sensors and 24 4.5-Hz vertical geophones during the period of January 2011 to May 2013. Dispersion curves of the Rayleigh waves obtained by the extended spatial autocorrelation method were inverted to derive shear-wave velocity ($v_s$) models comprising 40 horizontal layers of 1-m thickness. Depths to weathered rocks ($D_b$), shear wave velocities of these basement rocks ($v_s^b$), average velocities of the overburden layer ($\bar{v}_s^s$), and the average velocity to a depth of 30 m ($v_s30$), were then derived from those models. The estimated values of $D_b$, $v_s^b$, $\bar{v}_s^s$, and $v_s30$ for 46 sites at lower altitudes were in the ranges of 5 to 29 m, 404 to 561 m/s, 208 to 375 ms/s, and 226 to 583 m/s, respectively. According to the Korean building code for seismic design, the estimated $v_s30$ indicates that the lower altitude areas in Chuncheon are classified as $S_C$ (very dense soil and soft rock) or $S_D$ (stiff soil). To determine adequate proxies for $v_s30$, we compared the computed values with land cover, lithology, topographic slope, and surface elevation at each of the measurement sites. Due to a weak correlation (r = 0.41) between $v_s30$ and elevation, the best proxy of them, applications of this proxy to Chuncheon of a relatively small area seem to be limited.
Journal of the Economic Geographical Society of Korea
/
v.19
no.2
/
pp.286-299
/
2016
The increase of elderly population is inevitable a universal trend in developed countries. The Korea also followed this tendency. Especially the elderly population in Korea has been rapidly increasing since the 1990s. The rural population is aging more rapidly than the urban one because younger generations move into the urban area, due to better jobs and children education's opportunities. However, the majority of studies on population ageing are focused on the urban area rather than the rural ones. Rural areas also have been excluded as a priority of the national welfare policy for the elderly people. This paper tries to analyze the population ageing among regions and to identify the regional disparity between the elderly people and the level of public services in the rural area. Based upon these results, this study notes some policy alternatives for the improvement of quality of life of the rural elderly. It also suggests on the suitable location of public service facilities in the rural areas.
Journal of the Korean Association of Geographic Information Studies
/
v.17
no.4
/
pp.69-85
/
2014
Carbon stocks of NFI plots can be accurately estimated using field survey information. However, an accurate estimation of carbon stocks in other unsurveyed sites is very difficult. In order to fill this gap, various spatial information can be used as an ancillary data. In South Korea, there is the 1:5,000 forest type map that was produced by digital air-photo interpretation and field survey. Because this map contains very detailed forest information, it can be used as the high-quality spatial data for estimating carbon stocks. In this study, we compared three upscaling methods based on the 1:5,000 forest type map and 5th national forest inventory data. Map algebra(method 1), RK(Regression Kriging)(method 2), and GWR(Geographically Weighted Regression)(method 3) were applied to estimate forest carbon stock in Chungcheong-nam Do and Daejeon metropolitan city. The range of carbon stocks from method 2(1.39~138.80 tonC/ha) and method 3(1.28~149.98 tonC/ha) were more similar to that of previous method(1.56~156.40 tonC/ha) than that of method 1(0.00~93.37 tonC/ha). This result shows that RK and GWR considering spatial autocorrelation can show spatial heterogeneity of carbon stocks. We carried out paired t-test for carbon stock data using 186 sample points to assess estimation accuracy. As a result, the average carbon stocks of method 2 and field survey method were not significantly different at p=0.05 using paired t-test. And the result of method 2 showed the lowest RMSE. Therefore regression kriging method is useful to consider spatial variations of carbon stocks distribution in rugged terrain and complex forest stand.
Journal of the Korean Institute of Landscape Architecture
/
v.49
no.6
/
pp.27-36
/
2021
At a time when the equitable use of urban parks is gradually emerging as a social issue, this study was initiated to expand the influence of urban parks by improving the quality of park services, thereby resolving areas not covered by urban park services. This study targeted the Hangang Park in Seoul, where the qualitative service of parks shows the greatest difference. The influence relationship between the qualitative services of the park and the user's sphere of influence, which indicates the distribution of park users, was proposed to assess the influence of improvements in the quality of service. As a research method, the top three districts and the bottom three districts were selected through the Han River Park user satisfaction survey conducted from 2017 to 2019, and a qualitative service evaluation was carried out. It was derived using the data acquired in September. Afterward, by performing a spatial autocorrelation analysis on the user's sphere of influence, additional verification of the user's sphere of influence was performed numerically and visually. As a result of the study, the user influence in the top three districts, with high-quality service, was stronger and wider than that of the lower three districts. It was confirmed that the quality of service of the park affects the user influence. This shows that to realize park equity, it is necessary to improve the quality of services through continuous management and improvement of individual parks and the creation of new parks. This study has significance in that it recognizes the limitations of research on park services from a supplier's point of view and evaluates the qualitative services of parks from the perspective of actual park users. We propose an alternative to deal with the lower the park deprivation index.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.