• Title/Summary/Keyword: Spatial Therapy

Search Result 149, Processing Time 0.026 seconds

Dose Rate of Restroom in Facilities using Radioisotope (방사성동위원소 사용시설(내/외) 화장실의 외부선량률)

  • Cho, Yong-Gwi;An, Seong-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.237-246
    • /
    • 2016
  • This study is therefore aimed at measuring the surface dose rate and the spatial dose rate in and outside the radionuclide facility in order to ensure safety of the patients, radiation workers and family care-givers in their use of such equipment and to provide a basic framework for further research on radiation protection. The study was conducted at 4 restrooms in and outside the radionuclide facility of a general hospital in Incheon between May 1 and July 31, 2014. During the study period, the spatial contamination dose rate and the surface contamination dose rate before and after radiation use were measured at the 4 places-thyroid therapy room, PET center, gamma camera room, and outpatient department. According to the restroom use survey by hospitals, restrooms in the radionuclide facility were used not only by patients but also by family care-givers and some of radiation workers. The highest cumulative spatial radiation dose rate was 8.86 mSv/hr at camera room restroom, followed by 7.31 mSv/hr at radioactive iodine therapy room restroom, 2.29 mSv/hr at PET center restroom, and 0.26 mSv/hr at outpatient department restroom, respectively. The surface radiation dose rate measured before and after radiation use was the highest at toilets, which are in direct contact with patient's excretion, followed by the center and the entrance of restrooms. Unsealed radioactive sources used in nuclear medicine are relatively safe due to short half lives and low energy. A patient who received those radioactive sources, however, may become a mobile radioactive source and contaminate areas the patient contacts-camera room, sedation room, and restroom-through secretion and excretion. Therefore, patients administered radionuclides should be advised to drink sufficient amounts of water to efficiently minimize radiation exposure to others by reducing the biological half-life, and members of the public-family care-givers, pregnant women, and children-be as far away from the patients until the dose remains below the permitted dose limit.

Effect of the Space Dose Rate due to Change of X-ray Irradiation Energy and MU Value in Radiation Therapy Room (선형가속기의 엑스선 조사에너지와 MU값의 변화가 치료실 내 공간선량률 변화에 미치는 영향)

  • Kwon, Hyeonghyo;Park, Geonryul;Kim, Minji;Jo, Yeongdan;Kim, Youngjae
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.77-83
    • /
    • 2020
  • This study investigated the radiation protection of therapeutic radiologists. Based on the change in X-ray energy and MU value, the space dose rate in the treatment room after the irradiation was measured. 6MV, 10MV and 15MV photon beams were exposed to radiation inside the treatment room based on 300MU, 600MU and 1000MU using a linear accelerator. And repeated 10 times under the same conditions. As a result of the experiment, 0.1555 μSv/h for 6MV 300MU, 0.157 μSv /h for 300sec, 0.152 μSv/h, 0.156 μSv/h for 600MU, and 0.157 μSv/h 0.152 μSv/h for 1000MU. 300MU of 10MV was 0.49 μSv/h, 0.309 μSv/h, and 0.69 μSv/h, 0.416 μSv/h for 600MU, respectively, and 1000MU was 0.977 μSv/h and 0.478 μSv/h, respectively. The 300MU of 15MV was 3.02 μSv/h, 1.2 μSv/h, 5.459 μSv/h at 600MU, 7.34 μSv/h at 1.836 μSv/h 1000MU, and 2.709 μSv/h. The average spatial dose rate of 6MV was not significantly different from the natural spatial dose rate in the treatment room. High spatial dose rates were measured at 10 MV and 15 MV and were attenuated over time. Therefore, entering the treatment room after a certain period of time (more than 60 seconds) is considered to be effective to prevent the exposure dose of radiation workers.

A Study of Image Quality and Exposed Dose by Field Size Changing on CBCT (CBCT 촬영 시 조사야 조절에 따른 영상의 최적화 및 피폭선량에 관한 고찰)

  • Bang, Seung Jae;Kim, Young Yeon;Jeong, Il Seon;Kim, Jeong Soo;Kim, Young Gon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.175-180
    • /
    • 2013
  • Purpose: Modern radiation therapy technique such as IGRT has become a routine clinical practice on LINAC for decrease patient's set-up error. CBCT can be used to adjust patient set-up error and treat patient more accurately. The Purpose of this study is to evaluate field size of CBCT for improving Image quality and suggest reference date of CBCT field size. Materials and Methods: Image date were acquired using KV CBCT and Catphan phantom (Half fan and full fan mode were scanned from 2 ~16 cm, at intervals of 2 cm). Field size were categorized by Small field size (2 cm, 4 cm), Medium field size (8 cm, 10 cm), Large field size (more than 14 cm) and evaluate. To estimated the CTDi using CTDi phantom and Ion chamber. Results: CT number linearity of Small and Large field size are greater than Medium field size. Spatial resolution are not significantly different without Small field size. But half fan mode is more different than full fan mode. In full fan, except Medium field size, all field size exceed recommendation for HU uniformity. But half pan has stability for all field except Small field size. CTDi makes radical sign function graph in Medium field size. Conclusion: The worst result was given by Small field size for Image quality and practically. Medium field size can be useful to prevent patient from radiation exposure and give better Image quality. So this study recommends that Medium field size (8~10 cm) is more suitable for CBCT.

  • PDF

Evaluation of Skin Dose and Image Quality on Cone Beam Computed Tomography (콘빔CT 촬영 시 mAs의 변화에 따른 피부선량과 영상 품질에 관한 평가)

  • Ahn, Jong-Ho;Hong, Chae-Seon;Kim, Jin-Man;Jang, Jun-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose: Cone-beam CT using linear accelerator attached to on-board imager is a image guided therapy equipment. Because it is to check the patient's set-up error, correction, organ and target movement. but imaging dose should be cause of the secondary cancer when taking a image. The aim of this study is investigation of appropriate cone beam CT scan mode to compare and estimate the image quality and skin dose. Materials and Methods: Measurement by Thermoluminescence dosimeter (TLD-100, Harshaw) with using the Rando phantom are placed on each eight sites in seperately H&N, thoracic, abdominal section. each 4 methods of scan modes of are measured the for skin dose in three time. Subsequently, obtained average value. Following image quality QA protocol of equipment manufacturers using the catphan 504 phantom, image quality of each scan mode is compared and analyzed. Results: The results of the measured skin dose are described in here. The skin dose of Head & Neck are measured mode A: 8.96 cGy, mode B: 4.59 cGy, mode C: 3.46 cGy mode D: 1.76 cGy and thoracic mode A: 9.42 cGy, mode B: 4.58 cGy, mode C: 3.65 cGy, mode D: 1.85 cGy, and abdominal mode A: 9.97 cGy, mode B: 5.12 cGy, mode C: 4.03 cGy, mode D: 2.21 cGy. Approximately, dose of mode B are reduced 50%, mode C are reduced 60%, mode D are reduced 80% a point of reference dose of mode A. the results of analyzed HU reproducibility, low contrast resolution, spatial resolution (high contrast resolution), HU uniformity in evaluation item of image quality are within the tolerance value by recommended equipment manufacturer in all scan mode. Conclusion: Maintaining the image quality as well as reducing the image dose are very important in cone beam CT. In the result of this study, we are considered when to take mode A when interested in soft tissue. And we are considered to take mode D when interested in bone scan and we are considered to take mode B, C when standard scan. Increasing secondary cancer risk due to cone beam CT scan should be reduced by low mAs technique.

  • PDF

The Efficacy of Treadmill Training with Body Weight Support on Ambulation with Stroke Patients (체중현수 트래드밀 훈련이 뇌졸중 환자의 보행에 미치는 영향)

  • Kim, Seong-Hak;Park, Rae-Joon;Park, Heung-Gi;Kim, Ho-Bong;Chae, Soo-Gyung;Kim, Chun-Il
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.10 no.1
    • /
    • pp.83-101
    • /
    • 2004
  • The propose of the study was to evaluate the efficacy of the partial body weight support during treadmill training on the ambulation in elderly with chronic stroke. Fourteen hemiplegic volunteers participated and were divided into an experimental and control groups. In the experimental group, the body weight support during treadmill training was performed 3 times per week for 6 weeks. In the control group, usual treadmill training was applied. Before and after experiments, temporal-spatial gait parameters were measured. The date of 14 patients who carried out the whole experimental course were statistically analyzed. The results of the study were : 1. In the comparison of gait velocity before and after experiment, the gait velocity was significantly increased in the experimental group and the control group(p<.05). In the comparison of difference of the gait velocity between groups, there was not, significant difference between the experimental group and the control group(p>.05). 2. In comparison of gait cadence before and after experiment, the gait cadence was significantly increased in both groups(p<.05). In the comparison of difference of the gait cadence between groups, there was not significant difference between the experimental group and the control group(p>.05). 3. In the comparison of step length before and after experiment, the step length was significantly increased in the experimental group and the control group(p<.05). In the comparison of difference of the step length between groups, there was not significant difference between the experimental group and the control group(p>.05). 4. In the comparison of single support time asymmetry before and after experiment, the single support time asymmetry was no significant difference between groups(p>.05). In the comparison of difference of the single support time asymmetry between groups, there was not significant difference between the experimental group and the control group(p>.05). 5. In the comparison of step length asymmetry before and. after experiment, the step length asymmetry was not significant difference between the experimental group and the control group(p>.05). In the comparison of difference of the single step length asymmetry between groups, there was not significant difference between the experimental group and the control group(p>.05).

  • PDF

The Efficacy of Treadmill Training with Body Weight Support on Ambulation and Muscle Activity with Elderly Chronic Stroke (체중현수 트래드밀 훈련이 뇌졸중노인의 보행과 근활성에 미치는 영향)

  • Kim, Seong-Hak
    • Journal of Korean Physical Therapy Science
    • /
    • v.11 no.2
    • /
    • pp.27-37
    • /
    • 2004
  • The propose of the study was to evaluate the efficacy of the partial body weight support during treadmill training on the ambulation in elderly with chronic stroke. Fourteen hemiplegic volunteers participated and were divided into an experimental and control groups. In the experimental group, the body weight support during treadmill training was performed 3 times per week for 6 weeks. In the control group, usual treadmill training was applied. Before and after experiments, temporal-spatial gait parameters were measured. The date of 14 patients who carried out the whole experimental course were statistically analyzed. The results of the study were : 1. In the comparison of gait velocity before and after experiment, the gait velocity was significantly increased in the experimental group and the control group(p<.05). In the comparison of difference of the gait velocity between groups, there was not significant difference between the experimental group and the control group(p>.05). 2. In comparison of gait cadence before and after experiment, the gait cadence was significantly increased in both groups(p<.05). In the comparison of difference of the gait cadence between groups, there was not significant difference between the experimental group and the control group(p>.05). 3. In the comparison of step length before and after experiment, the step length was significantly increased in the experimental group and the control group(p<.05). In the comparison of difference of the step length between groups, there was not significant difference between the experimental group and the control group(p>.05). 4. In the comparison of vastus medialis root mean square(RMS) before and after experiment, the vastus medialis RMS was significantly increased in the experimental group(p<.05). In the comparison of vastus medialis root mean square(RMS) before and after experiment, the vastus medialis RMS was not significantly increased in the experimental group(p>.05). In the comparison of difference of the vastus medialis RMS between groups, there was not significant difference between the experimental group and the control group(p>.05). 5. In the comparison of latency of somatosensory evoke potential(SSEP) before and after experiment, the latency of SSEP was significantly increased in the experimental group(p<.05). In the comparison of latency of somatosensory evoke potential(SSEP) before and after experiment, the latency of SSEP was significantly decreased in the control group(p>.05). In the comparison of difference of the latency of SSEP between groups, there was not significant difference between the experimental group and the control group(p>.05). 6. In the comparison of functional ambulation profile(FAP) before and after experiment, the FAP was not significant difference in the experimental group and the control group(p>.05). In the comparison of difference of the FAP between groups, there was not significant difference between the experimental group and the control group(p>.05).

  • PDF

A Study on the Development of a Technology to Improve Anger Coping Strategies Using Location-based Service (위치기반 서비스를 활용한 분노대처 능력 향상 서비스 기술개발에 관한연구)

  • Lee, Pung-Sam;Lee, Yun-Gil
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.9
    • /
    • pp.289-296
    • /
    • 2017
  • Anger cause heart disease and domestic violence and recently there have been an increasing number of media reports of crimes committed because of their inability to control their anger. Anger has been reported to cause massive financial losses due to heart disease and domestic violence. Therefore, since anger raises serious social problems and social costs, it is necessary to take active intervention methods to alleviate inappropriate anger coping. A variety of methods such as cognitive and emotional approach, psycho-mechanical approach, psycho-educational approach, relaxation therapy, cognitive behavior-art therapy, and stress immunization are being explored and utilized for presenting effective anger-coping intervention alternatives. In this manner, information and communication technology is likely to be used as an effective means for this, and various researches are being conducted. The purpose of this study is to develop an anger coping service technology using ICT (Information & Communication Technology) technology as an effort to improve anger coping ability. In other words, the goal is to develop a technology that delays anger and evokes the surroundings by providing location-based services to recognize anger situations and facilitate anger. This research is about the technology which intervene directly the anger situation to resolve it using location information and introduce the base technology to realize it.

Commissioning Experience of Tri-Cobalt-60 MRI-guided Radiation Therapy System (자기공명영상유도 Co-60 기반 방사선치료기기의 커미셔닝 경험)

  • Park, Jong Min;Park, So-Yeon;Wu, Hong-Gyun;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.193-200
    • /
    • 2015
  • The aim of this study is to present commissioning results of the ViewRay system. We verified safety functions of the ViewRay system. For imaging system, we acquired signal to noise ratio (SNR) and image uniformity. In addition, we checked spatial integrity of the image. Couch movement accuracy and coincidence of isocenters (radiation therapy system, imaging system and virtual isocneter) was verified. Accuracy of MLC positioing was checked. We performed reference dosimetry according to American Association of Physicists in Medicine (AAPM) Task Group 51 (TG-51) in water phantom for head 1 and 3. The deviations between measurements and calculation of percent depth dose (PDD) and output factor were evaluated. Finally, we performed gamma evaluations with a total of 8 IMRT plans as an end-to-end (E2E) test of the system. Every safety system of ViewRay operated properly. The values of SNR and Uniformity met the tolerance level. Every point within 10 cm and 17.5 cm radii about the isocenter showed deviations less than 1 mm and 2 mm, respectively. The average couch movement errors in transverse (x), longitudinal (y) and vertical (z) directions were 0.2 mm, 0.1 mm and 0.2 mm, respectively. The deviations between radiation isocenter and virtual isocenter in x, y and z directions were 0 mm, 0 mm and 0.3 mm, respectively. Those between virtual isocenter and imaging isocenter were 0.6 mm, 0.5 mm and 0.2 mm, respectively. The average MLC positioning errors were less than 0.6 mm. The deviations of output, PDDs between mesured vs. BJR supplement 25, PDDs between measured and calculated and output factors of each head were less than 0.5%, 1%, 1% and 2%, respectively. For E2E test, average gamma passing rate with 3%/3 mm criterion was $99.9%{\pm}0.1%$.

Effects of Performing Dual Task on Temporospatial Gait Variables in Subjects With Subacute Stroke (아급성기 뇌졸중 환자의 이중 과제 수행이 보행의 시·공간적 변수에 미치는 영향)

  • Jang, Young-Min
    • PNF and Movement
    • /
    • v.15 no.3
    • /
    • pp.361-371
    • /
    • 2017
  • Purpose: The purpose of this study was to examine the effects of performing a dual task on gait velocity, temporospatial variables, and symmetry in subjects with subacute stroke. Methods: The study included 14 independent community ambulators with gait velocity of 0.8m/s. The Korean mini-mental state examination, the Berg balance scale, the Trunk impairment scale, and the Fugl-Meyer assessment scale were used to recruit homogeneous subjects. Subjects performed a single task (10m ambulation at a comfortable speed) and a dual task (10m ambulation at a comfortable speed while carrying a water-filled glass). Gait variables were examined with the OptoGait system. Results: The findings of this study were as follows: 1) Gait velocity decreased significantly in the dual-task condition as compared to the single task condition. 2) There were no significant differences between the paretic and non-paretic stances. 3) Paretic swing decreased significantly in the dual-task condition as compared to the single task condition. 4) The non-paretic, double-limb support phase increased significantly in the dual-task condition as compared to the single- task condition. 5) There was no significant difference in temporal symmetry. 6) Non-paretic step length decreased significantly in the dual-task condition as compared to the single-task condition. 7) There was no significant difference in spatial symmetry. Conclusion: Performing dual tasks decreases gait velocity, paretic swing phase, and non-paretic step length, while it increases non-paretic double limb support. In addition, although there is no difference in temporospatial symmetry, there is high inter-subject variability in temporospatial symmetry. Thus, dual tasks should be selected in accordance with the functional level of the hemiplegic patient, and inter-subject variability of the individual should be considered when dual tasks are considered for gait-training of hemiplegic patients.

Fast Approximate Dose Model Used in Arc Therapy (아크 치료를 위한 고속 근사선량모델 개발)

  • Suh, Tae-Suk;Suh, Doug-Young
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.4
    • /
    • pp.227-236
    • /
    • 1995
  • Using beam data and accurate 3D dose model, a study of the spatial dose distribution for various arcs was carried out. The dose dirstibution generated by the accurate dose model could be represented by a simple approximate analytic form which is convenient and very efficient for calculating dose distribution iteratively in the optimization procedure. We developed an empirical cylindrical dose model to compute dose for one full rotational arc or partial rotational arc. After a tedious search for fits to a collection of 200 points of accurate dose data, we found simple formular with 7 parameters search. As a consequence, the programs required approximately less than 1 second to compute dose for one single arc on a 20 by 20 matrix (400 points) using fast approximate dose model. In conclusion the fast approximate dose model give dose distributions similar to the accurate dose model, which makes this fast dose model an attractive alternative to the accurate 3D dose model.

  • PDF