• 제목/요약/키워드: Spalling

검색결과 475건 처리시간 0.034초

Spalling of the Oxide Scales Foemed on Stainless Steels During Cooling

  • Saeki, Isao;Ogama, Tetsuro;Furuichi, Ryusaburo;Kikkawa, Shinichi
    • Corrosion Science and Technology
    • /
    • 제2권5호
    • /
    • pp.225-232
    • /
    • 2003
  • High temperature oxidation of SUS430 and SUS304 stainless steels in 16.7 kPa $O_2$ - 20.3 kPa $H_2O$ - balanced N2 atmosphere at 1273 K was studied focused on the scale spalling during cooling after an isothermal oxidation. Spalling of the oxide scale during cooling occurred only for SUS304 stainless steel. The oxide scale was composed of two layers and they detached at the interface between them. The reason for the spalling could not be explained only by thermal stresses applied to the specimen during heating and cooling. A new mechanism for scale spalling was proposed based on combination of thermal stresses and thermal shock caused by a fast Martensite transformation of substrate metal.

고성능 콘크리트의 폭렬방지 공법 시공사례 (A Case Study on the Field Construction of Spalling Resistance Method of High Performance Concrete)

  • 김경민;허영선;이재삼;지석원;이성연;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.610-613
    • /
    • 2006
  • This paper is the fundamental study for manufacture of spalling resistance concrete and also analyses the mechanism and spalling resistance method with materials, mixture proportion and lateral confinement. The present work with the basic experiment achieved successful method for spalling resistance using both proper amounts of fiber contents and lateral confinement using metal lath. Moreover, the developed spalling resistance method was applied for full sized column construction in the Doosan We've Poseidon I field, located in Busan city. Authors investigated the physical properties examining workability, placeability and pumpability. These studies are continuously processing to develop new technology expecting remarkable impact on the spalling resistance and fire resistance performance of high-raise building construction in the future.

  • PDF

고강도 콘크리트의 폭렬발생 및 폭렬저감 메커니즘에 관한 문헌적 고찰 (A Study on the Mechanism of Explosive Spalling and Spalling Prevention Methods of High-Strength Concrete in Fire Temperature)

  • 정희진;이재영;김재환;한병찬;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.313-316
    • /
    • 2008
  • Nowadays, the use of high strength concrete has become increasingly popular. Thus, the theory of this study gives a definition of HSC mechanism through study factors of spalling occurrence of HSC and solutions of failure mechanism. During the fire goes on, building structure using HSC causes explosive spalling and finally it gets to the breaking of the structure down. As a result of this failure mechanism, it remains to be investigated to prevent from explosive spalling of HSC and needs to provide basic problems of HSC at high temperature.

  • PDF

복합유기섬유를 사용한 고강도 콘크리트의 기초특성 및 폭렬방지 (Fundamental Properties and Spalling Resistance of High Strength Concrete Containing Hybrid Organic fiber)

  • 배장춘;한동엽;이진우;한창평;양성환;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.745-748
    • /
    • 2006
  • This study investigates the fundamental properties and examines spalling appearances and residual compressive strength of high strength concrete containing hybrid organic fibers subjected to fire. Test showed that overall, an increase of fiber content decreased the fluidity of concrete, but specimens containing polyvinyl alcoho(PVA)+polypropylene(PP) fiber and nylon(NY)+PP fiber had improved flow. In addition, the air content of all specimens was properly ranged in target value, regardless of fiber content. As for the spalling properties when completed the fire test, control concrete exhibited spalling occurrence due to sudden elevated temperature. However, specimens containing more than 0.1 vol% of PP fiber prevented the spalling, while specimens containing PP+CL and PVA+PP fiber can protected from fire in more than 0.15vol% of the fiber content. Importantly, a specimen containing only 0.05vol% of NY+PP showed the favorable spalling resistance performance.

  • PDF

Leveraging artificial intelligence to assess explosive spalling in fire-exposed RC columns

  • Seitllari, A.;Naser, M.Z.
    • Computers and Concrete
    • /
    • 제24권3호
    • /
    • pp.271-282
    • /
    • 2019
  • Concrete undergoes a series of thermo-based physio-chemical changes once exposed to elevated temperatures. Such changes adversely alter the composition of concrete and oftentimes lead to fire-induced explosive spalling. Spalling is a multidimensional, complex and most of all sophisticated phenomenon with the potential to cause significant damage to fire-exposed concrete structures. Despite past and recent research efforts, we continue to be short of a systematic methodology that is able of accurately assessing the tendency of concrete to spall under fire conditions. In order to bridge this knowledge gap, this study explores integrating novel artificial intelligence (AI) techniques; namely, artificial neural network (ANN), adaptive neuro-fuzzy inference system (ANFIS) and genetic algorithm (GA), together with traditional statistical analysis (multilinear regression (MLR)), to arrive at state-of-the-art procedures to predict occurrence of fire-induced spalling. Through a comprehensive datadriven examination of actual fire tests, this study demonstrates that AI techniques provide attractive tools capable of predicting fire-induced spalling phenomenon with high precision.

고강도 콘크리트의 폭렬형태에 미치는 가열속도의 영향 (Effect of Heating Rate on Spalling Type of High-Strength Concrete)

  • 황의철;김규용;손민재;서동균;이예찬;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.237-238
    • /
    • 2021
  • This study evaluated the vapor pressure and thermal stress of high-strength concrete according to spalling type. As a result, it was confirmed that the internal temperature gradient of the concrete varies depending on the heating rate, and the vapor pressure and thermal stress of the concrete are the main factors of spalling. In addition, it was confirmed that spalling type varies depending on the vapor pressure and thermal stress of the concrete.

  • PDF

섬유종류 및 혼입량에 따른 고성능콘크트의 폭열저감에 관한 실험적 연구 (An Experimental study on Reduction Effect to Explosive spalling of high performance concrete by Fiber Type and Volume Fraction of Fiber)

  • 나철성;신관수;김영선;권영진;김규용;김무한
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2005년도 공동추계학술논문발표회 논문집
    • /
    • pp.81-85
    • /
    • 2005
  • Recently, fire resistance of high performance concrete for explosive spalling was issued as high performance concrete was vulnerable to the explosive spalling in initial fire. Therefore, in this study, an experiment about reduction effect to explosive spalling of high performance concrete is performed by adding several polymer fiber with various volume fraction, an then final fiber and volume fraction of that which reduce the explosive spalling of high performance concrete is presented. As the result of this study, the most fitted fiber volume fraction of reducing effect for explosive spalling at high performance concrete is under the 0.1%, as consider the flowability and efficiency.

  • PDF

Evaluation on Spalling Properties of Specimen Size with PP Fiber and Fireproof Coating

  • Kim, Gyu-Yong;Min, Choong-Siek;Lee, Tae-Gyu;Miyauchi, Hiroyuki;Park, Gyu-Yeon;Lee, Gwang-Jun
    • 한국건축시공학회지
    • /
    • 제11권4호
    • /
    • pp.353-362
    • /
    • 2011
  • High Strength Concrete (HSC) has weakness that in a fire, it is spalled and brittles. The phenomenon of spalling is made by water vapor's being confined in watertight concrete. This study is aimed to evaluate explosive spalling properties of high strength concrete with ${\square}100{\times}100{\times}200$ mm specimen and ${\square}400{\times}400{\times}1500$ mm column. To prevent spalling of concrete, fireproof coating and PP fiber are used. As a result, ${\square}400{\times}400{\times}1500$ mm column was prevented spalling likes ${\times}100{\times}100{\times}200$ mm specimen. When concrete protected failure to explosive spalling, quantity heat ratio (which fireproof coating specimen to pp fiber mixed specimen) between ${\square}100{\times}100{\times}200$ mm and ${\square}400{\times}400{\times}1500$ mm was maximum value at 20 minute, but difference of quantity heat ratio decreased and quantity heat ratio of each specimen is almost same at 30 minute.

박리를 고려한 지하박스구조물의 화재하중해석 I : 박리해석 (Fire Loading Analysis of Underground Box Structure with Considering of Concrete Spalling I : Spalling Analysis)

  • 이계희;최익창
    • 한국전산구조공학회논문집
    • /
    • 제20권4호
    • /
    • pp.477-483
    • /
    • 2007
  • 본 연구에서는 전력구나 공동구와 같은 지하 콘크리트박스구조물의 화재발생시 온도분포와 박리거동에 대한 수치해석을 수행하였다. 해석에 사용된 온도장은 터널화재에 사용하는 화재곡선을 기본으로 하고 화재시 내부공간에 대한 열유체해석을 수행하여 온도분포를 결정하였다. 박리거동은 탈수화도를 따라 콘크리트의 온도가 기준값에 도달하였을때 발생하는 것으로 하였다. 이때 박리가 일어난 요소를 제거하고 경계조건과 요소망을 재생성하여 해석을 반복수행하였다. 3개의 화재 시나리오에 따라 해석을 수행하였고, 해석결과는 각 시나리오별로 타당한 박리거동을 보여주었다. 각 시나리오에 따른 구조물의 내하력은 본 논문의 2편에서 산정되었다.

PP섬유 혼입 고강도 경량골재콘크리트의 내화특성 (Fire Performance of Structural Lightweight Aggregate Concrete using PP fiber)

  • 송훈;추용식;이종규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.797-800
    • /
    • 2006
  • Normally, Structural light-weight aggregate concrete(LWC) has been main used in high rise building with the object of wight loss. In spite of LWC have the advantage of light-weight, limit the use of strength restrictions by reason that explosive spalling in fire. Especially, LWC is occurred serious fire performance deterioration by explosive spalling. Thus, this study is concerned with fire performance of LWC for the purpose of using PP fibers prevent to explosive spalling. From the experimental test result, LWC is happened explosive spalling.

  • PDF