• Title/Summary/Keyword: Spacing

Search Result 3,356, Processing Time 0.038 seconds

A Study of Feasibility of Dipole-dipole Electric Method to Metallic Ore-deposit Exploration in Korea (국내 금속광 탐사를 위한 쌍극자-쌍극자 전기탐사의 적용성 연구)

  • Min, Dong-Joo;Jung, Hyun-Key;Park, Sam-Gyu;Chon, Hyo-Taek;Kwak, Na-Eun
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.3
    • /
    • pp.250-262
    • /
    • 2008
  • In order to assess the feasibility of the dipole-dipole electric method to the investigation of metallic ore deposit, both field data simulation and inversion are carried out for several simplified ore deposit models. Our interest is in a vein-type model, because most of the ore deposits (more than 70%) exist in a vein type in Korea. Based on the fact that the width of the vein-type ore deposits ranges from tens of centimeters to 2m, we change the width and the material property of the vein, and we use 40m-electrode spacing for our test. For the vein-type model with too small width, the low resistivity zone is not detected, even though the resistivity of the vein amounts to 1/300 of that of the surrounding rock. Considering a wide electrode interval and cell size used in the inversion, it is natural that the size of the low resistivity zone is overestimated. We also perform field data simulation and inversion for a vein-type model with surrounding hydrothermal alteration zones, which is a typical structure in an epithermal ore deposits. In the model, the material properties are assumed on the basis of resistivity values directly observed in a mine originated from an epithermal ore deposits. From this simulation, we can also note that the high resistivity value of the vein does not affect the results when the width of the vein is narrow. This indicates that our main target should be surrounding hydrothermal alteration zones rather than veins in field survey. From these results, we can summarize that when the vein is placed at the deep part and the difference of resistivity values between the vein and the surrounding rock is not large enough, we cannot detect low resistivity zone and interpret the subsurface structures incorrectly using the electric method performed at the surface. Although this work is a little simple, it can be used as references for field survey design and field data Interpretation. If we perform field data simulation and inversion for a number of models and provide some references, they will be helpful in real field survey and interpretation.

Evaluation of Contralateral Breast Surface Dose in FIF (Field In Field) Tangential Irradiation Technique for Patients Undergone Breast Conservative Surgery (보존적 유방절제 환자의 방사선치료 시 종속조사면 병합방법에 따른 반대편 유방의 표면선량평가)

  • Park, Byung-Moon;Bang, Dong-Wan;Bae, Yong-Ki;Lee, Jeong-Woo;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.401-406
    • /
    • 2008
  • The aim of this study is to evaluate contra-lateral breast (CLB) surface dose in Field-in-Field (FIF) technique for breast conserving surgery patients. For evaluation of surface dose in FIF technique, we have compared with other techniques, which were open fields (Open), metal wedge (MW), and enhanced dynamic wedge (EDW) techniques under same geometrical condition and prescribed dose. The three dimensional treatment planning system was used for dose optimization. For the verification of dose calculation, measurements using MOSFET detectors with Anderson Rando phantom were performed. The measured points for four different techniques were at the depth of 0cm (epidermis) and 0.5cm bolus (dermis), and spacing toward 2cm, 4cm, 6cm, 8cm, 10cm apart from the edge of tangential medial beam. The dose calculations were done in 0.25cm grid resolution by modified Batho method for inhomogeneity correction. In the planning results, the surface doses were differentiated in the range of $19.6{\sim}36.9%$, $33.2{\sim}138.2%$ for MW, $1.0{\sim}7.9%$, $1.6{\sim}37.4%$ for EDW, and for FIF at the depth of epidermis and dermis as compared to Open respectively. In the measurements, the surface doses were differentiated in the range of $11.1{\sim}71%$, $22.9{\sim}161%$ for MW, $4.1{\sim}15.5%$, $8.2{\sim}37.9%$ for EDW, and 4.9% for FIF at the depth of epidermis and dermis as compared to Open respectively. The surface doses were considered as underestimating in the planning calculation as compared to the measurement with MOSFET detectors. Was concluded as the lowest one among the techniques, even if it was compared with Open method. Our conclusion could be stated that the FIF technique could make the optimum dose distribution in Breast target, while effectively reduce the probability of secondary carcinogenesis due to undesirable scattered radiation to contra-lateral breast.

  • PDF

A Study on Movement of the Free Face During Bench Blasting (전방 자유면의 암반 이동에 관한 연구)

  • Lee, Ki-Keun;Kim, Gab-Soo;Yang, Kuk-Jung;Kang, Dae-Woo;Hur, Won-Ho
    • Explosives and Blasting
    • /
    • v.30 no.2
    • /
    • pp.29-42
    • /
    • 2012
  • Variables influencing the free face movement due to rock blasting include the physical and mechanical properties, in particular the discontinuity characteristics, explosive type, charge weight, burden, blast-hole spacing, delay time between blast-holes or rows, stemming conditions. These variables also affects the blast vibration, air blast and size of fragmentation. For the design of surface blasting, the priority is given to the safety of nearby buildings. Therefore, blast vibration has to be controlled by analyzing the free face movement at the surface blasting sites and also blasting operation needs to be optimized to improve the fragmentation size. High-speed digital image analysis enables the analyses of the initial movement of free face of rock, stemming optimality, fragment trajectory, face movement direction and velocity as well as the optimal detonator initiation system. Even though The high-speed image analysis technique has been widely used in foreign countries, its applications can hardly be found in Korea. This thesis aims at carrying out a fundamental study for optimizing the blast design and evaluation using the high-speed digital image analysis. A series of experimentation were performed at two large surface blasting sites with the rock type of shale and granite, respectively. Emulsion and ANFO were the explosives used for the study. Based on the digital images analysis, displacement and velocity of the free face were scrutinized along with the analysis fragment size distribution. In addition, AUTODYN, 2-D FEM model, was applied to simulate detonation pressure, detonation velocity, response time for the initiation of the free face movement and face movement shape. The result show that regardless of the rock type, due to the displacement and the movement velocity have the maximum near the center of charged section the free face becomes curved like a bow. Compared with ANFO, the cases with Emulsion result in larger detonation pressure and velocity and faster reaction for the displacement initiation.

PREDICTION OF THE SUM OF MESIODISTAL WIDTHS OF THE UNERUPTED PERMANENT CANINES AND PREMOLARS (미맹출 영구견치 및 소구치의 폭경 예측)

  • Park, Dong-Ock;Sung, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.18 no.2
    • /
    • pp.407-420
    • /
    • 1988
  • The primary objective of this study was to make the prediction percentile tabulation of the sum of mesiodistal widths of the unerupted permanent canines and premolars derived from the sum of mesiodistal widths of the erupted permanent incisors in normal and crowding groups. Crowding group consisted of 85 pairs of dental casts (42 males and 43 females) with more than 4mm of crowding in anteriors. Normal group consisted of 109 pairs of dental casts (65 males and 44 females) with less than 1mm of spacing or crowding in anteriors. The mesiodistal crown diameters of permanent teeth were measured from the dental casts using the sliding calipers (Mitutoyo Co., Japan). From the study, the obtained results were as follows: There were not significant differences between male and female in both groups on the basis of the ratios between the sum of mesiodistal widths of incisors and the sum of mesiodistal widths of canines and premolars. There was not significant difference between two groups on the basis of the ratio between the sum of mesiodistal widths of mandibular incisors and the sum of mesiodistal widths of mandibular canines and premolars and was significant differences between two groups on the basis of the ratio between the sum of mesiodistal widths of mandibular incisors and the sum of mesiodistal widths of maxillary canines and premolars. There was significant difference between two groups on the basis of the ratio between the sum of mesiodistal widths of maxillary incisors and the sum of mesiodistal widths of mandibular canines and premolars. There was significant difference between two groups on the basis of the ratio between the sum of mesiodistal widths of maxillary incisors and the sum of mesiodistal widths of maxillary canines and premolars. The percentile prediction tabulations were made in an attempt to predict the sum of mesiodistal widths of the unerupted permanent canines and premolars derived from the sum of mesiodistal widths of the erupted permanent mandibular incisors in each group. The percentile prediction tabulations were made in an attempt to predict the sum of mesiodistal widths of the unerupted permanent canines and premolars derived from the sum of mesiodistal widths of the erupted permanent maxillary incisors in each group.

  • PDF

Toxic Impact Analysis by Exposure Duration of Dog Studies for Pesticides using in Korea (국내 사용농약의 노출 기간이 개의 독성반응에 미치는 영향 분석)

  • Lee, Je Bong;Jeong, Mi-Hye;You, Are-Sun;Hong, Soonsung;Paik, Min-Kyoung;Oh, Jin-Ah;Park, Kyung Hun;Ihm, Yang Bin
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.4
    • /
    • pp.350-358
    • /
    • 2013
  • Both 13-week and 1-year studies in dog were required for pesticide registration in domestic pesticide control authority. It is raising issue up whether to request 1-year dog study of pesticides using non-food crop. So at this investigation, relevant toxicity test to establish acceptable daily intake (ADI), target organs, difference of no-observed adverse-effect levels (NOAELs) in 13-week and 1-year of 166 active ingredients are analyzed. The data were evaluated to determine if the 13-week dog study and the long term studies in two rodent species (mice and rats) without 1-year dog study were sufficient for the identification of NOAELs and lowest observed adverse effect levels (LOAELs) for the derivation of ADI. Toxicity end points and dose response data from 13 week and 1-year studies were compared. The analysis showed that 68 ADIs of the 166 pesticides were established from dog studies. Major target organs of dog studies were liver in 49 cases, body weight change in 21 cases, cholinesterase inhibition in 16 cases, and alteration in hematology in 14 cases. Similarity of target organ in 13-week and 1-year was 73%. 22 of 40 pesticides had similar critical effects regardless of duration and had NOAELs within a difference of 1.5-fold of each other. For the remaining 18 pesticides, 14 items had lower NOAELs in the 1-year study than 13-week study primarily due to dose selection and spacing. In only 10% of the cases were additional toxic effects identified in the 1-year study that were not observed in the 13-week study.

A study on the readability of web interface for the elderly user -Focused on readability of Typeface- (고령사용자를 위한 웹 인터페이스에서의 가독성에 관한 연구 -Typeface의 가독성을 중심으로-)

  • Lee, Hyun-Ju;Woo, Seo-Hye;Park, Eun-Young;Suh, Hye-Young;Back, Seung-Chul
    • Archives of design research
    • /
    • v.20 no.3 s.71
    • /
    • pp.315-324
    • /
    • 2007
  • The fast development of the information technology makes Korea one of the most advanced countries in information communication in the world in a short period of time. However, the gap between the aged and the young has been seriously increased. Those who are less than 10% of the older adults are using the internet at present. It means the elderly has many difficulties in using the internet because of their physical and cognitive differences. The purpose of this study is that the aged can easily achieve and use information by developing a guidelines for the Korean typography in the web interface. A literature search was conducted on the web interface design guidelines for older adults. These guidelines were classified by interface component and the study subjects needed for the Korean internet environment were selected. The subjects are a more comfortably readable typeface according to the sizes, a proper text size of Gulim and Batang, a more comfortably readable leading size, the appropriate letter spacing, the proper line length of body, the suitable size proportion between a title and a body, and a more comfortably readable text alignment. Survey questions were made and these Questions were improved after the pretest. Both online and offline survey programs were written and the aged and the young were tested with these programs. The result of this survey shows that there are satisfaction differences between the aged and the young in the readability and legibility of the web contents. Therefore these universal guidelines to be used in the Korean typographical environment for the future aged population were specified. It is expected that this study will be used as basic data for the universal web interface where the older adults can easily use and acquire information.

  • PDF

VARIETAL DIFFERENCES IN DISTRIBUTION AND PHYSIOLOGICAL CHARACTERISTICS OF RICEROOT (수도근(水稻根)의 분포(分布) 및 생리적(生理的) 특성(特性)에 관(關)한 품종간차이(品種間差異))

  • Park, H.;Park, Y.S.;Kim, Y.W.;Shin, C.S.;Kim, Y.S.
    • Applied Biological Chemistry
    • /
    • v.15 no.1
    • /
    • pp.49-57
    • /
    • 1972
  • Varietal difference in root distribution and other root characteristics were investigated under fold and water culture condition. The results were as follows: 1. IR667 showed funnel type of root distribution in soil profit while Jinheung had barrel type, and each type appearance was more distinguishable with fertilizer application. 2. Root weight per tiller was smaller in IR667 than in Jinheung and IR667 had more root in 0 to 5cm of soil depth but Jinheung had more in 5 to l0cm depth. 3. Horizontal distribution of root was dencer near to stem base without fertilizer than with fertilizer in both IR667 and Jinheung indicating structural construction for intensive nutrient uptake. Between varieties this 'dence to stem base' trend accompaning 'dence to wide spacing side' was greater in IR667 without fertilizer and these were quite true with fertilizer in Jinheung. 4. The decreasing rates of root and ear weight by fertilizer application were greater in IR667 than in Jinheung. This and other characteristics indicated that the root of IR667 is likely to be panicle-number type comparing with Jinheung. 5. The root of IR667 had lower oxidizing power of ${\alpha}-naphthylamine$ than that of Jinheung indicating weaker resistance to reductive soil but cation exchange capacity of water-cultured root was higher in IR667 suggesting stronger nutrient uptake. 6. The content of phosphorus and especially potassium in root were higher with fertilizer but lower without fertilizer in IR667 than in Jinheung indicating that IR667 is more sensitive to root environment. 7. The contents of N, K and CEC were increasing toward root tip while P content was decreasing. The root from surface soil had higher N and K content than that from subsoil. The contents of N,P,K, and CEC of root at harvesting stage were about 1.0%, 0.1%, 0.5% and 15me/100g at dry weight base, respectively.

  • PDF

Dosimetric Characterization of an Ion Chamber Matrix for Intensity Modulated Radiation Therapy Quality Assurance (세기변조방사선치료 선량분포 확인을 위한 2차원적 이온전리함 배열의 특성분석)

  • Lee, Jeong-Woo;Hong, Se-Mie;Kim, Yon-Lae;Choi, Kyoung-Sik;Jung, Jin-Beom;Lee, Doo-Hyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.131-135
    • /
    • 2006
  • A commercial ion chamber matrix was examined the characteristics and its performance for radiotherapy qualify assurance. The device was the I'mRT 2D-MatriXX (Scanditronix-Wellhofer, Schwarzenbruck, Germany). The 2D-MatriXX device consists of a 1020 vented ion chamber array, arranged in $24{\times}24cm^2$ matrix. Each ion chamber has a volume of $0.08cm^3$, spacing of 0.762 cm and minimum sampling time of 20 ms. For the investigation of the characteristics, dose linearity, output factor, short-term reproducibility and dose rate dependency were tested. In the testing of dose linearity. It has shown a good signal linearity within 1% in the range of $1{\sim}800$cGy. Dose rate dependency was found to be lower than 0.4% (Range: 100-600 Mu/min) relative to a dose rate of 300 Mu/min as a reference. Output factors matched very well within 0.5% compared with commissioned beam data using a ionization chamber (CC01, Scanditronix-Wellhofer, Schwarzenbruck, Germany) in the range of field sizes $3{\times}3{\sim}24{\times}24cm^2$. Short-term reproducibility (6 times with a interval of 15 minute) was also shown a good agreement within 0.5%, when the temperature and the pressure were corrected by each time of measurement. in addition, we compared enhanced dynamic wedge (EDW, Varian, Palo Alto, USA) profiles from calculated values in the radiation planning system with those from measurements of the MatriXX. Furthermore, anon-uniform IMRT dose fluence was tested. All the comparison studies have shown good agreements. In this study, the MatriXX was evaluated as a reliable dosimeter, and it could be used as a simplistic and convenient tool for radiotherapy qualify assurance.

  • PDF

Three-Dimensional Limit Equilibrium Stability Analysis of Spile-Reinforced Shallow Tunnel

    • Geotechnical Engineering
    • /
    • v.13 no.3
    • /
    • pp.101-122
    • /
    • 1997
  • A spiting reinforcement system is composed of a series of radially installed reinforcing spites along the perimeter of the tunnel opening ahead of excavation. The reinforcing spill network is extended into the in-situ soil mass both radially and longitudinally The sailing reinforcement system has been successfully used for the construction of underground openings to reinforce weak rock formations on several occasions. The application of this spiting reinforcement system is currently extended to soft ground tunneling in limited occasions because of lack of reliable analysis and design methods. A method of threetimensional limit equilibrium stability analysis of the smile-reinforced shallow tunnel in soft ground is presented. The shape of the potential failure wedge for the case of smile-reinforced shallow tunnel is assumed on the basis of the results of three dimensional finite element analyses. A criterion to differentiate the spill-reinforced shallow tunnel from the smile-reinforced deep tunnel is also formulated, where the tunnel depth, soil type, geometry of the tunnel and reinforcing spites, together with soil arching effects, are considered. To examine the suitability of the proposed method of threedimensional stability analysis in practice, overall stability of the spill-reinforced shallow tunnel at facing is evaluated, and the predicted safety factors are compared with results from twotimensional analyses. Using the proposed method of threetimensional limit equilibrium stability analysis of the smile-reinforced shallow tunnel in soft ground, a parametric study is also made to investigate the effects of various design parameters such as tunnel depth, smile length and wadial spill spacing. With slight modifications the analytical method of threeiimensional stability analysis proposed may also be extended for the analysis and design of steel pipe reinforced multi -step grouting technique frequently used as a supplementary reinforcing method in soft ground tunnel construction.

  • PDF

Feasibility of Two Dimensional Ion Chamber Array for a Linac Periodic Quality Assurance (선형가속기의 품질관리를 위한 2차원이온전리함배열의 유용성)

  • Lee, Jeong-Woo;Hong, Se-Mie;Park, Byung-Moon;Kang, Min-Young;Kim, You-Hyun;Suh, Tae-Suk
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.183-188
    • /
    • 2008
  • Aim of this study is to investigate the feasibility of 2D ion chamber array as a substitute of the water phantom system in a periodic Linac QA. For the feasibility study, a commercial ion chamber matrix was used as a substitute of the water phantom in the measurement for a routine QA beam properties. The device used in this study was the I'm RT MatriXX (Wellhofer Dosimetrie, Germany). The MatriXX consists of a 1,020 vented ion chamber array, arranged in $24{\times}24\;cm^2$ matrix. Each ion chamber has a volume of $0.08\;cm^3$, spacing of 0.762 cm. We investigated dosimetric parameters such as dose symmetry, energy ($TPR_{20,10}$), and absolute dose for comparing with the water phantom data with a Farmer-type ionization chamber (FC65G, Wellhofer Dosimetrie, Germany). For the MatriXX measurements, we used the white polystyrene phantom (${\rho}:\;1.18\;g/cm^3$) and also considered the intrinsic layer (${\rho}:\;1.06\;g/cm^3$, t: 0.36 cm) of MatriXX to be equivalent to water depth. In the preliminary study of geometrical QA using MatriXX, the rotation axis of collimator and half beam junction test were included and compared with film measurements. Regarding the dosimetrical QA, the MatriXX has shown good agreements within ${\pm}1%$ compared to the water phantom measurements. In the geometrical test, the data from MatriXX were comparable with those from the films. In conclusion, the MatriXX is a good substitute for water phantom system and film measurements. In addition, the results indicate that the MatriXX as a cost-effective novel QA tool to reduce time and personnel power.

  • PDF