• Title/Summary/Keyword: Spacers

Search Result 250, Processing Time 0.029 seconds

A Design of Optimal Masks in Hadamard Transform Spectrometers (하다마드 분광계측기의 마스크 설계)

  • 박진배
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.239-248
    • /
    • 1995
  • The method of increasing signal to noise ratio (SNR) in a Hadamard transform spectrometer (HTS) is multiplexing. The multiplexing is executed by a mask. Conventional masks are mechanical or electro-optical. A mechanical mask has disadvantages of jamming and misalignment. A stationary electro-optical mask has a disadvantage of information losses caused by spacers which partition mask elements. In this paper, a mixed-concept electro-optical mask (MCEOM) is developed by expanding the length of a spacer to that of lon-off mask element. An MCEOM is operated by stepping a movable mask. 2N measurements are required for N spectrum estimates. The average mean square error (AMSE) using MCEQM is equal to that using a stationary electro-optical mask without spacers for large N. The cost of manufacturing an MCEOM is lower than that of producing a conventional electro-optical mask because an MCEOM needs only (N + 1)/2 on-off mask elements whereas the con¬ventional electro-optical mask needs N on-off mask elements. There are no information losses in the spectrometers having an MCEOM.

  • PDF

Synthesis and Drug-Releasing Behavior of Various Polymeric Prodrugs of PGE1 with PEG and Its Derivative as Polymer Carriers

  • Lee, Chan-Woo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.484-493
    • /
    • 2007
  • Two polymeric prodrugs of PGE1 (prodrugs IVg and PNg) were newly synthesized. The drug conjugation proceeded in quantitative yield without decomposition of PGE1 to PGA1. With two types conjugates, PEG-PGE1 and PN-PGE1 with different spacer groups, we first discovered a possibility of slow release of PGE1 in blood circulatory system. PGE1 is conjugated with PEG and PN through the long alkylene spacers, and their availability as polymeric prodrugs is evaluated. Their drug-releasing behavior was examined both in phosphate buffer (pH=7.4) and rat plasma. Each prodrug was known to be highly stabile in the buffer solution. The drug-releasing rate became much faster in rat plasma than in the buffer solution due to the acceleration by the plasma enzymes. The drug-release was found to reach a plateau in rat plasma because the released PGE1 or its derivatives may be captured or decomposed by the plasma proteins. The slower drug-releasing rate of pro drug PNg in rat plasma is reasonably attributed to the molecular aggregation due to the hydrophobic bonding between the PGE1 moieties and spacers.

A Morphometric Study of the Lumbar Interspinous Space in 100 Stanford University Medical Center Patients

  • Jang, Donghwan;Park, Seoungwoo
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.5
    • /
    • pp.261-266
    • /
    • 2014
  • Objective : With the increased use of interspinous spacers in the treatment of lumbar stenosis, knowledge of the geometry of the interspinous space is important. To prevent dislodgment of an interspinous spacer, the accurate depth and width of the interspinous space needs to be established to facilitate the best intraoperative selection of correct spacer size. Methods : To determine the depth and width of the interspinous space, two methods are available which utilize plain film and magnetic resonance imaging (MRI). Data analysis of the interspinous depth and width was undertaken in 100 patients. Results : The standard deviations were variable, since skin thickness (zone 1) was altered by sex and age. The difference in the zone 1 distance between adjacent interspinous processes varied according to gender (p<0.05), but was not influenced by age [p=0.32 by analysis of variance between groups (ANOVA)]. Zone 2, the supraspinous, and zone 3, the interspinous ligament depths, comprise the operative working area during insertion of an interspinous spacer. There were no differences with regard to gender or age (p>0.05). For zones 6 and 7, the interspinous distances at the narrowest and widest points, respectively, were found to decrease with the aging process, but the decrease was not statistically significant. There were no differences with regard to gender (p>0.05). Conclusion : This study provides additional information on the interspinous space. This statistical data are valuable for use in the design of interspinous spacers.

The Effect of Flexible Spacers on the H-Shaped Dimesogenic Liquid Crystalline Compounds (H-자형 이메소젠 액정화합물의 유연격자 효과)

  • Park, Joo Hoon;Lee, Hwan Myoung;Choi, Ok Byung;Lee, Chang Joon;So, Bong Keun;Lee, Soo Min
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.6
    • /
    • pp.562-569
    • /
    • 2001
  • A homologous series of new H-shaped twin liquid crystal molecules (PPPA-n) with flexible spacers, oxypolymethyleneoxy, has been prepared by esterification of acid chloride of $\alpha$,$\omega$-bis(2,5-dicar-boxyphenoxy) alkanes with p-phenylphenol. The length of spacer was varied from oxyethyleneoxy (n=2) to oxydecamethyleneoxy (n=10). Their thermodynamic data were measured by differential scanning calorimetry and liquid crystalline properties were investigated by a hot-stage polarizing microscope.

  • PDF

A Study on the Spacer Installation Method for 2-Conductor Bundle Transmission Lines (2도체 송전선로의 스페이서 취부방식 연구)

  • Min, Byeong-Wook;Kim, Woo-Kyum;Choi, Han-Yeol;Park, Kee-Yong;Kim, Won-Jin;Park, Jae-Ung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.333-334
    • /
    • 2008
  • Overhead transmission lines are classified by the number of sub conductors per phase. Korean transmission lines use two, four, or six-conductor bundle. Bundle of conductors must have spacers or spacer dampers which keep the proper distance between sub conductors. They can prevent conductors from being vibrated or twisted due to the wind. As for the two-conductor bundle, alternating current flow generates absorption force between sub conductors which may cause a collision of sub conductors. To prevent sub conductors from being vibrated, twisted, and collided, spacer or spacer damper installation method is designed considering vibration characteristics of sub conductors. We have spacer installation method for four or six-conductor bundle lines. However, we don't have it for two-conductor bundle ones. So we have installed spacers at regular intervals in two-conductor bundle lines, and it caused rigid body oscillation of conductors due to the wind which made a flashover between conductors. This paper introduces a vibration characteristic analysis of two-conductor bundle and proposes a spacer installation method for two-conductor bundle lines.

  • PDF

Experimental Investigation on Air-Distribution in a Water-Flowing through a G1-Rod Bundle with Helical Spacers

  • Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.79-86
    • /
    • 1978
  • The object of this study was to obtain data on air-distributions in two-phase up flow in vertical rod-bundle test-section. The test-section in this study was a hexagonal shaped 61-rod bundle where each rod was wrapped with helical spacers. The variables were flow rates of air and water and air inlet positions. Experimental data were obtained at the outlet of the test-section. The experiments were performed in two parts. Firstly, data were taken at increasing flow rates of air keeping water flow rates constant, and secondly, at simultaneous increase of air and water flow rates. At each flow condition, air supply position could be changed to 4 different positions. Data obtained by electrical void-needle technique were analyed and are presented here in graphical forms for comparison. The results of this study demonstrate qualitatively that air-distribution tends to be more uniform as water flow rates are increased. The air supply positions have noticeable effects on the pattern of air-distribution.

  • PDF

Shape Design of A Spacer for 800kV GIS Interrupter (800kV급 GIS의 모델차단부용 스페이서의 형상설계)

  • Shin, Y.J.;Chang, K.C.;Park, K.Y.;Chong, J.K.;Song, W.P.;Kang, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1639-1642
    • /
    • 1994
  • The severe conditions such as rated voltage of 800kV, gas pressure of $5kg/cm^2$ and rated lighting impulse withstand voltage of 2400kV were adopted for the design of spacers in the 800kV GIS to give a sufficient design margin. The design criteria on the maximum electric field strength of the center conductor and the insulator surface were established by considering the insulator surface characteristics, electrode area and surface effects in the unequal electric field strength of the given gap. The design parameters such as inter/outer envelope degree, thickness, inter/outer inserts, triple junction gap were determined by calculating the electric field using FLUX-2D program package and by referring to the published papers. The mechanical stress analysis was conducted on the feasible model spacers that showed good electric field distributions to confirm the sufficient mechanical design margin. The 800kV spacer designed as described above is now in the process of manufacturing.

  • PDF

Performance Improvement of a Paper Enthalpy Exchange Element by Impregnation of the Spacer (골심지의 흡습제 함침에 의한 종이 재질 판형 전열교환 소자의 성능 향상)

  • Kim, Nae-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.142-147
    • /
    • 2017
  • Improvement of the enthalpy exchange element's energy efficiency is of current interest from anenergy-saving viewpoint. In this study, a LiCl-impregnated spacer was devised as a means to improve the performance of the enthalpy exchange element. Two samples were tested : one with and one without impregnated spacers of $338{\times}338{\times}380mm$ sizes with 2.0 mm channel spacing. The results showed that the temperature efficiencies of the two samples were approximately the same. The humidity efficiency, however, was strongly affected by the LiCl impregnation. The impregnated sample yielded a 9% higher humidity efficiency under cooling and the difference increased to 14% under aheating condition. It was anticipated that more moisture would beadsorbed on the LiCl-impregnated spacers, which was delivered to their roots and eventually to the air in neighboring channels. Separate moisture adsorption tests revealed that both the adsorption rate and the amount of the adsorbed moisture are higher for the LiCl-impregnated specimen.

New Liquid Crystalline Methacrylate Polymers Containing 4-Methacryloyloxyphenoxy Group and 4'-((S)-(+)-2-Methylbutoxy)biphenyl-4-carboxyl Mesogenic Group: 1. Synthesis and Characterization of the Monomers (4-Methacryloyloxyphenoxy기와 4'-((S)-(+)-2-methylbutoxy)biphenyl-4-carboxyl 메소겐기를 갖는 새로운 메타크릴레이트 액정화합물: 1. 단량체의 합성 및 특성)

  • So, Bong-Keun;Lee, Sang-Ho;Lee, Soo-Min
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.6
    • /
    • pp.599-608
    • /
    • 2004
  • New two kinds of methacrylate monomers having a benzene ring inserted between spacer and methacryloyl group and the chiral center connected to the terminal of the mesogenic structures were synthesized. In these two series the effects for the formation of the liquid crystals in regard to the length changes of the spacers and mesogenic groups were investigated. The first series did not show any liquid crystalline phases in the intermediate compounds nor in the end products. However, the methacrylates of second series showed the liquid crystalline phases in the intermediate compounds as well as in the final products regardless of the length of the spacers.

Numerical Analysis of Surface Discharge due to Particles Attached to the GIS spacer (GIS 스페이서에 파티클 부착시 연면방전과 전계해석)

  • Jang, D.G.;Lee, J.H.;Kwak, H.R.;Park, H.Y.;Kim, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1788-1790
    • /
    • 2003
  • GIS is a typical power equipment with higher reliability. It is compact and safe because all the energized parts are enclosed by a sealed cylindrical tank which is filled with $SF_6$. Generally gas insulated power equipments like GIS are designed to have sufficient electrical strength to prevent partial discharges under normal operating condition. Despite of the careful processes in manufacturing, transporting and assembling, voids or particles can be created, resulting in partial discharges at electrically weak points. The key factors causing partial discharges in GIS are; particles, voids in solid insulation, protrusions, poor contact of metal components, etc. The particle can be attached on; spacers, electrodes, internal wall of the GIS tank. It also moves in GIS freely. Most of partial discharges are likely to occur when particles are attached to spacers. In this paper, the electrical characteristics of a surface discharge were investigated under various conditions by using simulation program of FEMLAB.

  • PDF