• 제목/요약/키워드: Spacer Damper

검색결과 19건 처리시간 0.029초

2도체 송전선로의 스페이서 취부방식 연구 (A Study on the Spacer Installation Method for 2-Conductor Bundle Transmission Lines)

  • 민병욱;김우겸;최한열;박기용;김원진;박재웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.333-334
    • /
    • 2008
  • Overhead transmission lines are classified by the number of sub conductors per phase. Korean transmission lines use two, four, or six-conductor bundle. Bundle of conductors must have spacers or spacer dampers which keep the proper distance between sub conductors. They can prevent conductors from being vibrated or twisted due to the wind. As for the two-conductor bundle, alternating current flow generates absorption force between sub conductors which may cause a collision of sub conductors. To prevent sub conductors from being vibrated, twisted, and collided, spacer or spacer damper installation method is designed considering vibration characteristics of sub conductors. We have spacer installation method for four or six-conductor bundle lines. However, we don't have it for two-conductor bundle ones. So we have installed spacers at regular intervals in two-conductor bundle lines, and it caused rigid body oscillation of conductors due to the wind which made a flashover between conductors. This paper introduces a vibration characteristic analysis of two-conductor bundle and proposes a spacer installation method for two-conductor bundle lines.

  • PDF

송전선로에서 스페이서지그(Spacer Jig)를 이용한 스페이서댐퍼 유지보수공법 (Spacer Damper Maintenance Method by Using the Spacer Jig in Overhead Transmission Lines)

  • 김점식;권세원;박용범;권신원;문성원;조성문;김도영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.22-24
    • /
    • 2008
  • 다도체 송전선로에서 전선 간격 유지 및 진동을 완화시켜주는 역할을 하는 스페이서댐퍼가 손상 받게 되면 즉시 유지보수 및 교체 작업을 하여야 한다. 그러나 이러한 작업은 송전선로 위에서 이루어지므로 전선의 장력과 작업자의 하중으로 인해 유지보수 및 교체작업이 매우 어렵고, 작업시간이 많이 소요되며, 전선표면손상, 스페이서댐퍼의 위치 변동 및 무리한 작업으로 인한 작업안전성 저하 등의 문제점이 있다. 따라서, 상기한 문제점을 해소하고 작업 효율의 상승을 위하여 작업시 각 전선의 간격을 쉽게 벌리고 좁힐 수 있는 작업용 공구인 스페이서지그(Spacer Jig)와 이를 이용한 송전선로의 스페이서댐퍼 유지보수 및 교체공법을 개발하여 교체작업시간 단축 및 작업안전성을 향상시킨 우수한 기술을 개발하였다.

  • PDF

송전선로 스페이서댐퍼 적정 설치방안 연구 (A Study on the Installation method of the Spacer Damper for Bundled T/L)

  • 이형권;손홍관;이동일;위화복;박완동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.436-438
    • /
    • 2003
  • Wind-induced oscillations are known to cause damage to the conductors and related hardware through fatigue, clashing of the bundled conductors and bolt loosening. Wake-induced oscillations have been known since the advent of bundled conductors, they are caused by aerodynamically unstable forces acting on the leeward conductors in the wake of the windward conductors, They take the form of horizontal galloping, snaking or rolling, in which case all subconductors move together in unison. They can also take the form of the subspan oscillation, which appear as elliptical motions of the subconductors moving out of phase, mainly in the horizontal plane within a subspan. In order to decrease amplitudes of the oscillation, this paper examines the application status of the spacer dampers and suggests proper installation methods.

  • PDF

765kV 6도체용 스페이서댐퍼 교체를 위한 스페이서지그 개발 (A Development of the Spacer Jig for Spacer Damper Replacement of 6 Bundle conductor 765kV Transmission Line)

  • 김점식;김도영;문성원;조성문;권세원;박용범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2077-2078
    • /
    • 2008
  • 다도체 송전선로에서 전선 간격 유지 및 진동을 완화시켜주는 역할을 하는 스페이서 댐퍼가 손상 받게 되면 즉시 유지보수 및 교체 작업을 하여야 한다. 그러나 이러한 작업은 송전선로 위에서 이루어지므로 전선의 장력과 작업자의 하중으로 인해 유지보수 및 교체작업이 매우 어렵고, 작업시간이 많이 소요되며, 전선표면 손상, 스페이서 댐퍼의 위치 변동 및 무리한 작업으로 인한 작업안전성 저하 등의 문제점이 있다. 따라서, 상기한 문제점을 해소하고 작업 효율의 상승을 위하여 작업시 각 전선의 간격을 쉽게 벌리고 좁힐 수 있는 작업용 공구인 스페이서지그(Spacer Jig)와 이를 이용한 송전선로의 스페이서 댐퍼 유지보수 및 교체공법을 개발하여 교체작업시간 단축 및 작업안전성을 향상시킨 우수한 기술을 개발하였다.

  • PDF

스페이서 강성과 간격이 송전선 갤러핑에 미치는 영향분석 (Effect Analysis of Spacer Stiffness and Interval on Galloping of Power Transmission Lines)

  • 오윤지;손정현
    • 한국기계가공학회지
    • /
    • 제18권1호
    • /
    • pp.52-58
    • /
    • 2019
  • Due to icing and snow, power transmission lines have asymmetric cross sections, and their motion becomes unstable. At this time, the vibration caused by the wind is called galloping. If galloping is continuous, short circuits or ground faults may occur. It is possible to prevent galloping by installing spacers between transmission lines. In this study, the transmission line is modeled as a mass-spring-damper system by using RecurDyn. To analyze the dynamic behavior of the transmission line, the damping coefficient is derived from the free vibration test of the transmission line and Rayleigh damping theory. The drag and lift coefficient for modeling the wind load are calculated from the flow analysis by using ANSYS Fluent. Galloping simulations according to spacer stiffness and interval are carried out. It is found that when the stiffness is 100 N/m and the interval around the support is dense, the galloping phenomenon is reduced the most.

4도체 가공선로에서 복도체 스페이서를 이용한 진동저감 대책 연구 (A Study on Measures Against Subspan Oscillation using Twin Spacers in 4 Bundle Overhead Lines)

  • 이형권;한형주
    • 전기학회논문지P
    • /
    • 제58권3호
    • /
    • pp.323-327
    • /
    • 2009
  • The oscillation is very dangerous in bundled transmission lines, besides 4 bundle transmission lines are very weak for subspan oscillations. In some cases, subspan oscillations are continuously occurred in the same subspan. In order to develop the control method of the above subspan oscillation, this paper suggests a method of applying twin spacers to the subspans. We have carried out some tests to analyze the oscillation phenomena after installing twin spacers on 4 bundle overhead lines, and we got a good effect for controling subspan oscillations by installing twin spacers.

Field Observation and Analysis of Wind-Induced Vibrations in Four-Bundled Conductor Transmission Lines

  • Sohn, Hong-Kwan;Lee, Hyung-Kwon;Chu, Jang-Hee;Lee, Dong-Il;Lee, Eun-Woong
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권2호
    • /
    • pp.109-114
    • /
    • 2003
  • This paper presents observations made on four-bundled conductor transmission lines concerning the behavior of conductors under the effect of natural winds. To know the wind-induced vibration status and how to control it, wind-induced vibrations have been recorded and analyzed from the real transmission lines. From the field observation and analysis results, subspan oscillation was found to be the main type of vibration. In addition, the data also revealed some common characteristics of the observation sites with high maintenance rates. The results will be used in controlling the subspan oscillations and protecting the conductors.

동역학 해석을 통한 송전선로 검사로봇 프레임 설계에 관한 연구 (Dynamic Stiffness Design of Inspection Robot Frame Using Multi-body Dynamic Simulation)

  • 이준영;김문영;임지윤;김창환;임홍재
    • 한국소음진동공학회논문집
    • /
    • 제25권3호
    • /
    • pp.169-175
    • /
    • 2015
  • This study aims to improve the dynamic stiffness of an inspection robot frame to prevent derailment from transmission lines. Finite element models for the transmission lines and robot frame are developed for the multi-body dynamic simulation. Natural frequency analysis was conducted using the FE models. Three types of spacer damper clamps installed on 4-conductor transmission lines are used to evaluate the derailment of the robot. Multi-body dynamic simulations with FE models are demonstrated for sub-span oscillation. When the robot operates, derailment of inspection robot from the transmission lines is determined because of resonance. To prevent the resonance, body position was changed and thickness optimization was conducted. The results show that derailment was not occurred because of the natural frequency improvement.