• 제목/요약/키워드: Space heating

검색결과 675건 처리시간 0.028초

TAP을 적용한 내단열과 외단열구조의 열성능 평가에 관한 연구 (A Study on Thermal Performance Evaluation with TAP (Thermosyphoning Air Panel) in Inside and Outside Insulated Constructions)

  • 이경회;유호천;홍영우;전채휘
    • 태양에너지
    • /
    • 제7권1호
    • /
    • pp.23-29
    • /
    • 1987
  • TAP system, a kind of natural convective space heating collector, has a good heat loss by night. The aim of this paper is to induce and to study an hourly heat flow theory by response factors analysis with TAP in inside and outside insulated construction, to compare and evaluate on thermal performance an hourly natural temperature, heated room temperature and heating load in aboved-mention constructions with computer simulation. The results of the study can be summarized as follows. According that there is no TAP and with TAP, it is inside insulated construction and outside insulated construction, daily natural range of temperature each shows $12.5^{\circ}C$ and $16.7^{\circ}C$, $2.7^{\circ}C$ and $3.7^{\circ}C$, daily heated range of temperature with noramal control heating system each shows $6.6^{\circ}C$ and $12.1^{\circ}C$, $1.7^{\circ}C$ and $3.1^{\circ}C$, heating hours each show 10 hr and 7 hr, 9 hr and 4 hr and heating energy saving percentage in january 123% and 79%, 100% and 40%. Therefore, energy saving percentage shows that outside insulated construction saves about 54% in comparision with inside insulated construction.

  • PDF

지붕형 태양광발전 패널의 공장 지붕 설치에 따른 냉방 및 난방 부하 변화량 연구 (A Study of Cooling and Heating Load Changes with Roof Type Solar Panels Installed on Factory Roof)

  • 조호현;김정민;김영일
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권4호
    • /
    • pp.9-15
    • /
    • 2020
  • In this study, effect of reinforced insulation on heating and cooling loads were studied due to installation of PV panels on factory building roof with a floor area of 12,960 m2. For PV panel installation, combination of aluminum, polyurethane, air, polystyrene and steel materials were added to the original roof, which increased thermal insulation performance. Half of the roof were covered with PV panel and the other half without. Temperature and relative humidity were measured for 8 days during summer season for both indoor spaces. PV panel showed the effect of lowering the indoor space temperature by 0.6℃. TRNSYS dynamic simulation showed that with PV panel, cooling load per area is reduced by 1.7 W/m2 and heating by 10.0 W/m2. PV panels installed on building roof not only generate electricity but also can save energy by reducing cooling and heating loads.

이용자 평가를 통한 대학기숙사 내부공간의 거주환경개선에 관한 연구 -광주광역시내 종합대학 기숙사를 중심으로- (A Study on Improvement of Residential Environment for Indoor Space of University Dormitory through the Evaluation of User Satisfaction -the case of university dormitory in gwangju-)

  • 박행자;박성진;이청웅
    • 한국주거학회논문집
    • /
    • 제18권2호
    • /
    • pp.129-136
    • /
    • 2007
  • This study, as a case study of four university dormitories in Gwangju, examined the situation of interior space and conducted a quantitative survey investigating importance about the interior space and assessment factors of residential environment on users. Then user satisfaction at the assessment factors of residential environment was analyzed to draw problems and explore improvement. The results showed the following problems that should be resolved: Bedrooms should increase the area of convex space; toilets and bathrooms should be changed into a cluster type at least in common use by floor; rest space should reinforce heating and cooling system; robby space should become mixed space for various user's behavior; private fitness rooms should be planned as group fitness space; private libraries should reinforce lighting facilities; and computer rooms should complement and improve HVAC.

공간분활 및 영역열량측정에 의한 공평 자동난방운영시스템 구현 (System Implementation for Fair Automatic Heating Operation Based on Spatial Distributing and Zonal Calorie Measuring)

  • 한상철;류광렬
    • 한국정보통신학회논문지
    • /
    • 제23권8호
    • /
    • pp.910-916
    • /
    • 2019
  • 본 논문은 주거공간영역 별로 사용 난방열량을 측정하고 사용량을 자동으로 측정 분석하여 계량 운영 할 수 있는 공평관리 자동난방운영시스템의 구현이다. 난방공간은 4영역으로 분할하여 하나의 계량기로 유량과 열량이 계측된다. 이 시스템은 열량검출, 온도조절기, 밸브제어기, PC컨버터와 모니터링으로 구성된다. 난방 공간영역은 실내온도에 따라 열량 계산에 필요한 환수 온도가 측정되고 영역별 열량이 산출된다. 실험결과, 측정기기로 계측한 값과 비교하여 측정열량 값의 오차 범위는 1% 내이다. 기존의 유량계를 이용한 난방 분할 방식과 비교하면 난방 에너지 사용 비용이 약 7% 저감된다. 이 공평시스템은 향후에는 BEMS와 공동으로 연계하는 연구가 필요하다.

산간지대 농가의 부엌공간 변화요인에 관한 연구 (A Study on the Factors Affecting Variations of Kitchen Spaces in Mountain-areas.)

  • 유옥순
    • 한국주거학회논문집
    • /
    • 제3권2호
    • /
    • pp.51-61
    • /
    • 1992
  • The aims of this study are to imvestigate the changes seen in rural kitchens and the factors affecting the modernization of agrarian kitchen space in mountain areas, and to compare them with those in the plains. The major findings are as follows. 1) The kitchen space in mountain areas remained in the state of a combined style(depicting both western and traditional styles), while the kitchen space in the plains after the 1980s showed a tendency toward the western style. Generally speaking, the physical state of kitchens in mountain farmhouses, therefore, was at a low level in comparison with that of the plains. 2) The kitchen improvement projects of Sae-Ma-Eul Movement fostered a trend toward the western and combined style kitchens in the plains, but it did exert a little influence only on a part of the four mountain areas, and it resu]led in a combination of both styles. 3) Among the socio-demographic characteristics under consideratien. only the level of education achieved by the wi fe was found to be a determinant factor of the kitchen type in the mountain areas. but the level of education achieved by the husband and the family life cycle were two determinant factors in the plains. Under the category of family life style. the factors affecting the kitchen type in the mountain areas were cooking-heating fuel and the position of the refrigerator, while the main factors in p]ains were the place and the method of eating. cooking-heating fuel, the position of refrigerator, and numbers of family-memorials.

  • PDF

우주 유연 붐의 열적 유기 진동에 관한 연구 (A Study on Thermally-induced Vibration of Space Flexible Booms)

  • 공창덕;오경원;방조혁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1631-1636
    • /
    • 2003
  • The purpose of this study is to analyze the phenomena of the thermally-induced vibration for the flexible space structure due to abrupt change of radiation heating circumstance using the numerical analyze and experiment test. In order to verify this structure, numerical approaches on the simplified flexible tube were compared with experimental test results at the ground experimental facility In this analyze, it was found that the thermal deformation occurs firstly due to fast radiation heating of flexible structure and then the thermally-induced vibration would be induced due to small periodic change of temperature. According to comparison of numerical and experimental result, in case of no tip mass, the first mode vibration by the numerical analyze was O.78Hz same as that of the experimental result However in case of increase tip-masses of 8g l6g, 50g and 100g, the first modes vibration theoretical analyze were 1.75Hz, 1.3Hz, 0.87Hz and O.73Hz, in decrease trend respectively and those by experimental test were 234Hz, 1.5Hz, O.78Hz and O.78Hz in decrease trend respectively Although using the simpled equation for the estimation, the estimation results were similar to experimental results.

  • PDF

지열을 이용한 외기부하저감시스템의 냉각 및 가열효과 예측을 위한 간이추정법에 관한 연구 (A Study on the Simplified Presumption Method for the Prediction of Cooling and Heating Performance in a Fresh Air Load Reduction System by Using Geothermal Energy)

  • 손원득;박경순
    • 설비공학논문집
    • /
    • 제22권9호
    • /
    • pp.628-634
    • /
    • 2010
  • This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space. The fresh air is introduced into the double slab space and passes through the opening bored into the footing beam. The air is cooled by the heat exchange with the inside surface of the double slab space in summer, and heated in winter. This system not only reduces sensible heat load of the fresh air by heat exchange with earth but also reduces latent heat load of the fresh air by ad/de-sorption of underground double slab concrete. In this paper, we proposed a simplified presumption method for the prediction of cooling and heating performance in the system. In conclusion the proposed method has been verified by comparing with the calculated value of the numerical analysis model by using nonlinear two-dimension hygroscopic question.

시험 데이터 기반 소형 열진공챔버 시스템 식별에 관한 연구 (A Study on System Identification of Small Thermal Vacuum Chamber Based on Test Data)

  • 박성욱;김승균
    • 한국항공우주학회지
    • /
    • 제49권5호
    • /
    • pp.407-415
    • /
    • 2021
  • 인공위성의 부품은 발사 전 지상에서의 우주 궤도환경 하에서의 성능검증이 필수적이다. 본 논문은 열진공시험을 위한 위성 부품 및 소형 열진공챔버 간의 전도, 복사, 열손실 및 내부 발열의 열환경을 고려한 모델식을 설계하였다. 최근 한국항공우주연구원에서 수행된 열진공시험 20건의 시험데이터를 이용한 시스템 식별을 수행하였다. 시험품 기능시험의 발열이 일정하지 않는 경우를 제외하고 시스템 식별의 정확성을 확인함으로써 개발된 모델식이 유효함을 검증하였다.

강릉지역 전(田)자형 민가의 주생활 변화에 따른 주거공간의 변형 (The Residential Space Transformation of Vernacular Houses with 田-shaped Floor Plan according to the Housing Life Change at Gangreung Area)

  • 최장순
    • 한국농촌건축학회논문집
    • /
    • 제20권2호
    • /
    • pp.49-56
    • /
    • 2018
  • The vernacular houses with 田-shaped floor plan at Gangreung have been played important roles in tracing the vernacular living cultures including housing life. But due to the adoption of convenient facilities in vernacular housing lives caused by modernization and urbanization, many changes and transformations have happened at residential space of vernacular houses. This thesis targets to extract basic data to prepare and prevent various problems in process of renovation, extension and function change as installing housing life facilities, and to identify the changes and transformations of them to prepare the proper balances between their original form preservation and residents' convenience living. The results are as follows. The inner wall removal of rooms, the fuel change of cooking and heating, the leveling change of kitchen floor made possible the sedentary lifestyles. And its residential rooms were transformed from two row to one row by inner wall removal, the fuel heating change, the heating method change and the heat insulating materials. The residential extension materials were changed from the traditional materials such as soil, wood, etc to the modern materials such as cement block or brick, sandwich panel, etc. And the modern materials were used and attached to widen residential spaces to the vernacular house because of the easiness of execution. So, it is necessary for 田-shaped floor plan vernacular house owners to distribute printed execution guide book to prevent and minimize the various problems to be shown by extension, renovation and function change.

재해임시주거 냉난방을 위하여 기존 에어컨을 열펌프로 전환하는 변환기 개발 (Development of a Conversion Unit converting the existing air conditioner to Heat Pump System for the Emergency Shelter)

  • 송헌
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.77-84
    • /
    • 2011
  • Korea and some other countries located in the northern hemisphere employ the air conditioner for the space cooling in the hot summer season and also some kinds of heaters for the space heating in the cold winter season. Especially in Korea, a great number of air conditioners of about 12,700,000 sets have been used these days. However, they are used for a short operation period of only 58 days a year, which results in the material and economic losses. To solve this problem and employ this system for the emergency shelter, a new conversion unit which could convert the existing air conditioner to a heat pump system for simultaneous heating and cooling was developed in this study, and the thermal performance was tested. The results indicated that the indoor air could be heated from $27^{\circ}C$ to $39^{\circ}C$ by the air conditioner converted to a heat pump system with the ambient temperature variation of $-10^{\circ}C{\sim}10^{\circ}C$, and cooled from $20^{\circ}C$ to $15^{\circ}C$ by the converted system with the ambient temperature variation of $20^{\circ}C{\sim}35^{\circ}C$. And also the heating COP increased from 3.3 to 5.3 in case of the heat exchange of the super cooling(HESC) circuit and from 3.0 to 4.0 in case of the By-pass with the ambient temperature variation of $-10^{\circ}C{\sim}10^{\circ}C$, respectively, whereas the cooling COP decreased from 3.1 to 2.1with the increase of the ambient temperature from $20^{\circ}C$ to $35^{\circ}C$.