• 제목/요약/키워드: Space dose rate

검색결과 60건 처리시간 0.032초

강내치료실 차폐에 대한 고찰 (A Study on Structural Shielding Design of Afterloading Therapy Room)

  • 윤석록;김명호;신동오
    • 대한방사선치료학회지
    • /
    • 제2권1호
    • /
    • pp.31-40
    • /
    • 1987
  • In the case of designing a high dose rate remote controlled afterloading treatment room with existing hospital facilities. We must construct the effective protective barriers so as to reduce the primary and scattered radiation up to the maximum permissible dose level. It is difficult to reinforce the barrier thickness of the shielding requirements because of the limited space and the problem of the existing building structure at the surrounding area. Therefore we can reduce the intensity of primary radiation to the required degree at the location of interest with installing the appropriate I shaped Pb barriers between the radiation source and the shielding wall of the concrete. As a result, it was possible to reduce the intensity of the primary radiation below the M.P.D level by using additional Pb barriers instead of increasing thickness of concrete wall.

  • PDF

선량 중첩을 이용한 멀티형 연 X-선 정전기 제거장치의 개발 (Development of Multi-Type Soft X-ray Ionizer using Radiation Dose Overlapped Effect)

  • 이수환;이동훈
    • 한국안전학회지
    • /
    • 제33권2호
    • /
    • pp.28-31
    • /
    • 2018
  • In display and semi-conductor manufacturing process, there are numerous unstable factors such as particle concentration, minimal vibration, changes in magnetic field, or electrostatic that becomes an issue to be managed and controlled. In the recent, X-ray ionization is widely used that is neutralized by separating air or gas molecules in the area where the static must be resolved. The mono-type of X-ray ionizer was not capable to be used in $8^{th}$ generation panels manufacturing plant due to its insufficient ionizing coverage since the panel itself is approximately in $2m{\times}3m$. To resolve the current problem, the development of new type called, "Multi-type X-ray ionizer" has resulted in covering enough ionizing space in $8^{th}$ generation panels industry. Comparing mono and multi types with MCNPX code simulation, the multi one indicates more X-ray flux, efficiency, and ionization performance in comparison with either a mono-type or multi-type in array format. In addition, the ionizing efficiency of overlapping area with multi-type showed 30% higher effectiveness rate as to the ordinary mono-type.

Cosmic Ray Experiment on the KITSAT-1

  • Shin, Y.H.;Park, Y.W.;Min, K.W.;Kim, S.H.
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.10-10
    • /
    • 1993
  • The cosmic ray experiment (CRE) on board the KITSAT-1 has been operating normally since the launch of the satellite. CRE is composed of two parts : the cosmic particle experiment (CPE) and the total dose experiment (TDE). Of these, we will discuss on the CPE results obtained the last several months. The data show much larger high energy Particle flux than the Previous UOSAT-3 data. The 550(single event upset) rate is also an order of magnitude higher than the UOSAT-3result. We will compare these results with the Bredictions of the CREME codel. ReferTncesAdams, J. H., Jr., 1987, NRL Memorandun Report 5901

  • PDF

Remodeling of Infarcted Myocardium with Contrast-Enhanced Magnetic Resonance Imaging

  • 최병욱;최규옥;김영진;정남식;임세중
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2003년도 제8차 학술대회 초록집
    • /
    • pp.45-45
    • /
    • 2003
  • To evaluate remodeling of infarcted myocardium with contrast-enhanced MRI (co-MRI) at true end-diastole (ED) MRI was performed with a Gyroscan Intera (1.5 Tesla, Philips, Netherlands) in 13 patients with acute subendocardial myocardial infarction. The First exam was done 0-15 days (mean 5.2days) after symptom onset and the second exam 28-88days (mean 49 days) after the first exam. Ce-MRI encompassing the entire left ventricle was performed with a multi-shot, turbo-field-echo, breath-hold sequence and a non-selective, inversion prepulse 10 minutes after the intravenous injection of Gd-DTPA at a dose of 0.2 mmol/kg body weight. To allow the long TD, ECG synchronization should use two RR-intervals for one acquisition of a segment of k-space by setting the heart rate to half that of the true heart rate. Trigger delay time (TD) was adjusted to the RR-interval for true end-diastolic imaging. The other typical parameters were TR=5.4ms, TE=1.6ms, voxel size=1.37${\times}$1.37${\times}$10mm, k-space data segmented into 8 segments with 32 lines of segment per two cycles over 16 cardiac circles. The thickness of hyperenhanced myocardium and epicardially nonenhanced myocardium were followed.

  • PDF

Remodeling of Infarcted Myocardium with Contrast-Enhanced Magnetic Resonance Imaging

  • 최병욱;최규옥;김영진;정남식;임세중
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2003년도 제8차 학술대회 초록집
    • /
    • pp.92-92
    • /
    • 2003
  • To evaluate remodeling of infarcted myocardium with contrast-enhanced MRI (co-MRI) at true end-diastole (ED) MRI was performed with a Gyroscan Intera (1.5 Tesla, Philips, Netherlands) in 13 patients with acute subendocardial myocardial infarction. The First exam was done 0-15 days (mean 5.2days) after symptom onset and the second exam 28-88days (mean 49 days) after the first exam. Ce-MRI encompassing the entire left ventricle was peformed with a multi-shot, turbo-field-echo, breath-hold sequence and a non-selective, inversion prepulse 10 minutes after the intravenous injection of Gd-DTPA at a dose of 0.2 mmol/kg body weight. To allow the long TD, ECG synchronization should use two RR-intervals for one acquisition of a segment of k-space by setting the heart rate to half that of the true heart rate. Trigger delay time (TD) was adjusted to the RR-interval for true end-diastolic imaging. The other typical parameters were TR=5.4ms, TE=1.6ms, voxel size=1.37$\times$1.37$\times$10mm, k-space data segmented into 8 segments with 32 lines of segment per two cycles over 16 cardiac cycles. The thickness of hyperenhanced myocardium and epicardially nonenhanced myocardium were followed.

  • PDF

지하역사 승강장에서 코로나19 바이러스 공기감염 대응 공기조화기와 공기청정기의 적용 효과 비교 (Comparison of applicability of HVAC and air cleaners in a subway station platform against airborne infection of SARS-CoV-2)

  • 이건희;김상복;박인용;홍기정;이예완;김학준;김용진;한방우
    • 한국입자에어로졸학회지
    • /
    • 제18권3호
    • /
    • pp.51-59
    • /
    • 2022
  • In this work, virion concentration and its dose changes by HVAC and air cleaners were estimated in a subway station platform to control airborne infection of SARS-CoV-2. Collection efficiencies with particle size were measured for the air filter equipped in a HVAC in one subway station in Daejeon. Indoor PM2.5 changes according to outdoor PM2.5 with time were also measured to estimate air infiltration rate in the subway station platform. When infected persons generate virions by 104, 105, 106, 3 × 106 and 5 × 106 h-1 in a 2,400 m3 volume platform, the concentration and dose were estimated as 9, 92, 275 and 458 virions/m3 and 4, 43, 130 and 217 virions after 1 hour exposure, respectively. The concentration and dose were reduced by 70%, and 64%, respectively by operations of both HVAC (with a flow rate of 16,000 m3/h, MERV 11) and ten air cleaners(with total CADR 10,740 m3/h) compared to those without operation of both HVAC and air cleaners. However, virion dose in the platform was estimated to be too low at the general conditions due to a large space, a high air infiltration (3 h-1) and a short residence time (usually < 10 mins) in the platform irrespective of the operations of HVAC or air cleaners. HVAC with filters and air cleaners would be more necessary in the concourse or shopping areas in the subway stations to reduce the infection dose from a few hundred to several tens virions in a hour.

Understanding the Treatment Strategies of Intracranial Germ Cell Tumors : Focusing on Radiotherapy

  • Kim, Joo-Young;Park, Jeonghoon
    • Journal of Korean Neurosurgical Society
    • /
    • 제57권5호
    • /
    • pp.315-322
    • /
    • 2015
  • Intracranial germ cell tumors (ICGCT) occur in 2-11% of children with brain tumors between 0-19 years of age. For treatment of germinoma, relatively low radiation doses with or without chemotherapy show excellent 10 year survival rate of 80-100%. Past studies showed that neoadjuvant chemotherapy combined with focal radiotherapy resulted in unacceptably high rates of periventricular tumor recurrence. The use of generous radiation volume which covers the whole ventricular space with later boost treatment to primary site is considered as standard treatment of intracranial germinomas. For non-germinomatous germ cell tumors (NGGCT), 10-year overall survival rate is still much inferior than that of intracranial germinoma despite intensive chemotherapy and high-dose radiotherapy. Craniospinal radiotherapy combined with cisplatin-based chemotherapy provides the best treatment outcome for NGGCT; 60-70% of overall survival rate. There is a debate on the surgical role whether surgery can contribute to improved treatment outcome of NGGCT when added to combined chemoradiotherapy. Because higher dose of radiotherapy is required for treatment of NGGCT than for germinoma, it is tested whether whole ventricular irradiation can replace craniospinal irradiation in intermediate risk group of NGGCT to minimize radiation-related late toxicity in the recent studies. To minimize the treatment-related neural deficit and late sequelae while maintaining long-term survival rate of ICGCT patients, optimized administration of chemotherapy and radiotherapy should be selected. Use of technically upgraded radiotherapy modalities such as intensity-modulated radiotherapy or proton beam therapy is expected to bring an improved neurocognitive outcome with longitudinal assessment of the patients.

RALS에 장착한 Ir-192 선원의 강도측정에 대한 고찰 (Calibration of an $^{192}Ir$ Source Used for High Dose Rate RALS.)

  • 문언철
    • 대한방사선치료학회지
    • /
    • 제6권1호
    • /
    • pp.56-60
    • /
    • 1994
  • In the past, brachytherapy was carried out mostly with radium or radon sources. Currently. use of artificially produced radionuclially produced radionuclides such as $^{137}Cs,\;^{192}Ir,\;^{198}Au,\;and\;^{125}I$ is rapidly increasing. Although electrons are often used as an alternative to interstitial implants, brachytherapy continues to remain an important mode of therapy, either alone or combined with external beam. The National Council on Radiation Protection and Measurements(NCRP) recommends that the strength of any ${\gamma}$ emitter should be specified directly in terms of exposure rate in air at a specified distance such as 1m. The air kerma strength is defined as the product of air kerma rate in 'free space' and the square of the disrance of the calibration point from the source center along the perpendicular bisector, i. e., $S_k=K_L{\times}L^2$. Where $S_K$ is the the air kerma strength and K is the air kerma rate at a specified distance L. (usually 1m). Recommended units for all kerma strength are ${\mu}Gym^{2}h^{-1}$.

  • PDF

방사선조사가 백서 협점막에 미치는 영향에 관한 전자현미경적 연구 (AN ELECTRON MICROSCOPIC STUDY ON THE EFFECTS OF IRRADIATION ON THE BUCCAL MUCOSA OF RAT)

  • 최승규;이상래
    • 치과방사선
    • /
    • 제17권1호
    • /
    • pp.7-20
    • /
    • 1987
  • The author studied the acute reaction of cobalt-60 irradiation to buccal mucosa in rats and difference of the effects of single versus fractionated exposure. 195 Sprague Dowley strain rats, weighing about 120gm, were used in this experiment. 3 rats served as controls and the remaining 192 rats were divided into six groups of 32 rats each. Experimental group Ⅰ, Ⅱ, Ⅲ were received a single dose of 15Gy, 16.5Gy, 18Gy and group Ⅳ, Ⅴ, Ⅵ were received two equal sized fractionated dose of 9Gy, 9.75Gy, 10.5Gy at 4 hour intervals, respectively. The experimental groups were irradiated with cobalt-60 teletherapy unit, Picker model 4M 60 (Field size, 12x5 cm, SSD, 50㎝, Dose rate, 222cGy/min, Depth, 1㎝). The animals were sacrificed at 1, 2, 3, 6, 12 hours, 1, 3, 7 days after irradiation and the changes of the irradiated buccal mucosa were observed by electron and light microscopy. The results were as follows: 1. A single exposure was more damaging than fractionated exposure, and as the radiation dose increased, the changes of cell organelles became faster, but the healing of radiation-induced damage in fractionated exposure was faster than in single exposure. 2. The radiation-induced changes of the basal cells were the most prominent in 18Gy-single exposure group, and the least in 18Gy-fractionated exposure group. 3. Electron-microscopically, there appeared nuclear changes, swelling of mitochondria and rough endoplasmic reticulum, decrease of free ribosome, presence of vesicles, widening of intercellular space, and loss of basal lamina. The early remarkable changes were partly loss of nuclear membrane and swelling of mitochondria. 4. Light-microscopically, derangement and pyknosis of basal cells, hydropic changes of spinous cells, enlargement of granular cells, indistinctness of basement membrane, and proliferation of epithelium were observed.

  • PDF

척수강 내 약물 주입기의 이식 -증례보고- (Implantation of an Intrathecal Drug Administration System -A report of two cases-)

  • 이상진;남상건;김장현;김현주;이상철;김용철
    • The Korean Journal of Pain
    • /
    • 제22권1호
    • /
    • pp.68-73
    • /
    • 2009
  • Opioids profoundly inhibit evoked discharges of spinal nociceptive neurons, thereby inhibiting the transmission of pain. Intrathecal administration of opioids using implantable continuous infusion systems is an effective method of pain relief when other treatments have failed, as well as for patients with adequate analgesia on high dose therapy that produces unacceptable side effects. We report two cases of intrathecal pump implantation performed in patients suffering from intractable chronic pain. A test dose of 3 mg morphine was injected into the epidural space. No side effects were noted and patients experienced considerable pain relief. Implantation was performed one day after the test. The initial intrathecal morphine delivery dose was half of the equivalent dose of daily oral intake opioids and the infusion rate was increased gradually under close observation for opioid side effects. Two days post-implantation, both patients were discharged without any complications.