• Title/Summary/Keyword: Space current

Search Result 3,322, Processing Time 0.029 seconds

Power factor correction of the three phase boost converter using DSP control (DSP 제어에 의한 3상 Boost 컨버터의 역률개선)

  • Baek, Jong-Hyeon;Hong, Seong-Tae
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.958-961
    • /
    • 1998
  • In this paper, a three phase boost converter that operates with unity power factor and sinusodial input currents is presented. The current control of the converter is based on the space vector strategy with fixed switching frequency and the input current tracks the reference current within one sampling time interval. Space vector strategy for current control was materialized as a digital control method by using DSP. By using this control strategy low ripples in the output voltage, low harmonics in the input current and fast dynamic responses are achieved with a small capacitance in the dc link.

  • PDF

Conduction mechanism in organic light-emitting diode in ITO/PEDOT/PSS/TPD/Alq$_3$/LiAl structure (ITO/PEDOT/PSS/TPD/Alq$_3$/LiAl 구조의 유기 발광 소자에서 전도 메카니즘)

  • 정동회;김상걸;정택균;오현석;이원재
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.198-201
    • /
    • 2002
  • We have studied the temperature dependence of current-voltage and luminance-voltage characteristics of Organic Light Emitting Diodes(OLEDs). The OLEDS are based on the molecular compounds, N,N'-diphenyl-N,N'-bis(3-methylphenyl)-1,1'-biphenyl-4,4'-diamine (TPD) as a hole transport, tris(8-hydroxyquinolinoline) aluminum(III) (Alq$_3$) as an electron transport, and poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) as a buffer layer. The current-voltage and luminance-voltage characteristics were measured in the temperature range of 10[K] and 300[K]. A conduction mechanism in OLEDs has been interpreted in terms of space-charge-limited current(SCLC) and tunneling mechanism.

  • PDF

Modified Space-Vector Modulation Hysteresis Current Control Method (개선된 공간벡터형 히스테리시스 전류제어기법)

  • Jeong, An-Sik;Park, Ki-Won;Jeong, Seung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2529-2533
    • /
    • 1999
  • This paper proposes a modified hysteresis current control method based on space vector modulation. The proposed method differs from former works in that it uses effective voltage vectors instead of zero vectors while not significantly increasing the circuit complexity. The circuit uses outer band that is slightly wider than the usual current limit band (inner band) to detect the phase of current command and thereby the region information. The comparator output signals associated with the inner and outer band are used to determine the proper voltage vector that minimizes the current error and number of switching, with simple logic circuitry. The utilization of effective voltage vector is of particular importance when the ac-side emf is relatively large. Both the simulation and experiment show that the proposed method is more effective than the conventional one that uses zero vectors, in reducing the number of switching over a range of ac-side emf variation.

  • PDF

Predictive Current Control of Distribution Static Condenser (D-STATCON) for Reactive Power Compensation in Flexible AC Transmission System(FACTS) (유연송전시스템에서의 역률 보상을 위한 배전용 정지형 동기조상기의 전류제어)

  • 오관일;문건우;전영수;이기선;추진부
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.447-454
    • /
    • 1998
  • This paper describes a modeling and current control techniques of Distribution static condenser (D-STATCON) for power factor compensation. The current control is based on the predictive and the space vector PWM scheme. The predictive current controlled PWM D-STATCON can maintain its performance with power factor compensation and fixed switching frequency. By using the space vector control low ripple and offset in the current and the voltage as well as fast dynamic responses are achieved with a small DC link capacitance employed.

  • PDF

A Study on the Measurement Technique of the Grounding Mesh Resistance by Field Measurements (현장실측에 의한 메시(Mesh)접지저항 출정기법 연구)

  • 한기붕;김삼수;정세중;이상익
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.426-429
    • /
    • 1999
  • In this paper, we have provided the measurement technique of the grounding mesh resistance by field measurements. The standard of measurement is specified in the IEEE Std 81.2-1991 and JEAC 5001-1988, which is the the fall-of-potential method by test-current injection, but this method is difficult to apply at field, where is small around a electric power substation of domestic. For the convenient measurement method, space of assistant probe and quantity of test-current injection are changed step for step. As the result, ' the proposed measurement technique of grounding mesh resistance is that the space of current and potential probes must be fixed at 150rn from a grounding mesh, the test-current injection has to keep 5A or more.

  • PDF

A Study on the Novel Space Vector Based Harmonic Elimination Method of Inverter (인버터 고조파 저감을 위한 새로운 공간벡터 변조기법에 관한 연구)

  • Lee, Sang-Taik;Kim, Hee-Jun;Oh, Won-Seok;Shin, Tae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1236-1238
    • /
    • 2000
  • This paper considers the problem of eliminating harmonics in the inverter output waveforms. The approach is based on the minimization of the current harmonics in the induction motor by space vector modulation method. Reference voltage is compensated with injection of controlled current harmonics which are calculated to reduce current harmonics through sampled current harmonic analyzing algorithm. The theoretical analysis is carried out using computer simulation. It is verified that proposed SVM technique could reduce current harmonic component and improve THD.

  • PDF

Analysis of Interleaved Boost Power Factor Corrector (Interleaved 승압형 역률보상 컨버터의 해석)

  • Heo, Tae-Won;Park, Jee-Ho;Roh, Tae-Kyun;Chung, Jae-Lyoun;Kim, Dong-Wan;Woo, Jung-In
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.51 no.4
    • /
    • pp.186-192
    • /
    • 2002
  • In this paper, interleaved boost power factor corrector(IBPFC) is applied as a pre-regulator in switch mode power supply. IBPFC can reduce input current ripple and effectively increase the switching frequency without increasing the switching losses, because input current is divided each 50% by two switching devices. IBPFC can be classified as three cases by duty ratio condition in continuous current mode and be carried out state space average modeling. According to the modeling, steady and transient state analysis is performed by steady elements and perturbation element. Control transfer function is derived for design of control system.

Temperature Dependent Current-Voltage Characteristics of Organic Light-Emitting Diodes using TPD/$Alq_3$ (TPD/$Alq_3$를 이용한 유기 발광 소자의 온도에 따른 전압-전류 특성)

  • Han, Wone-Keun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.533-534
    • /
    • 2005
  • Temperature-dependent current-voltage characteristics of organic light-emitting diodes(OLEDs) were studied in a device structure of ITO/TPD/$Alq_3$/Al. The OLEDs were based on the molecular compounds, N,N'-diphenyl-N,N'-bis(3-methylphenyl)-l,1'-diphenyl-4,4'-diamine(TPD) as a hole transport and tris(8-hydroxyquinoline) aluminum($Alq_3$) as an electron transport and emissive material. The current-voltage characteristics were measured in the temperature range of 10K and 300K. We analyzed an electrical conduction mechanism of the OLEDs using space-charge-limited current(SCLC) and Fowler-Nordheim tunneling.

  • PDF

Model Predictive Control for Shunt Active Power Filter in Synchronous Reference Frame

  • Al-Othman, A.K.;AlSharidah, M.E.;Ahmed, Nabil A.;Alajmi, Bader. N.
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.405-415
    • /
    • 2016
  • This paper presents a model predictive control for shunt active power filters in synchronous reference frame using space vector pulse-width modulation (SVPWM). The three phase load currents are transformed into synchronous rotating reference frame in order to reduce the order of the control system. The proposed current controller calculates reference current command for harmonic current components in synchronous frame. The fundamental load current components are transformed into dc components revealing only the harmonics. The predictive current controller will add robustness and fast compensation to generate commands to the SVPWM which minimizes switching frequency while maintaining fast harmonic compensation. By using the model predictive control, the optimal switching state to be applied to the next sampling time is selected. The filter current contains only the harmonic components, which are the reference compensating currents. In this method the supply current will be equal to the fundamental component of load current and a part of the current at fundamental frequency for losses of the inverter. Mathematical analysis and the feasibility of the suggested approach are verified through simulation results under steady state and transient conditions for non-linear load. The effectiveness of the proposed controller is confirmed through experimental validation.

Eddy-Current Loss Analysis in Rotor of Surface-Mounted Permanent Magnet Machines Using Analytical Method (해석적 방법을 이용한 표면부착형 영구자석 기기의 회전자 와전류 손실해석)

  • Choi, Jang-Young;Choi, Ji-Hwan;Jang, Seok-Myeong;Cho, Han-Wook;Lee, Sung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1115-1122
    • /
    • 2012
  • This paper analyzes eddy-current loss induced in magnets of surface-mounted permanent magnet (SPM) machines by using an analytical method such as a space harmonic method. First, on the basis of a two-dimensional (2D) polar coordinate system and a magnetic vector potential, the analytical solutions for the flux density produced by armature winding current are obtained. By using derived field solutions, the analytical solutions for eddy current density distribution are also obtained. Finally, analytical solutions for eddy current loss induced in rotor magnets are derived by using equivalent electrical resistance calculated from magnet volume and analytical solutions for eddy-current density distribution. In particular, the influence of time harmonics in armature current on the eddy current loss is fully investigated and discussed. All analytical results are validated extensively by finite element analysis (FEA).