냉각된 복사천장패널의 열전달 특성에 관한 연구 (A Study on the Heat Transfer Characteristics of the Radiant Chilled Ceiling Panel for Space Cooling)

  • 이태원;황인주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.164-169
    • /
    • 2001
  • There is a chilled ceiling panel which carries out the air conditioning by radiation and convection between the room and cold ceiling panel surface. In order to verify heat transfer characteristics between them in cooling system with radiant chilled ceiling panel, analytical and experimental studies were performed for various design and operating parameters such as tube space and diameter, inlet water temperature, mass flow rate, cooling load, and so on. In this study, we found that the tube space and inlet water temperature were more important elements than the tube diameter and water flow rate for the performance of radiant chilled ceiling panel. The cooling capacity of the radiant chilled ceiling panel had the maximum value of $65W/m^{2}$ because the highest cooling capacity was limited by the condensation on the panel surface. The results of comparison between numerical analysis and experiment showed a resonable agreement qualitatively, especially for low cooling capacity.

  • PDF

Thermal Analysis of MIRIS Space Observation Camera for Verification of Passive Cooling

  • Lee, Duk-Hang;Han, Won-Yong;Moon, Bong-Kon;Park, Young-Sik;Jeong, Woong-Seob;Park, Kwi-Jong;Lee, Dae-Hee;Pyo, Jeong-Hyun;Kim, Il-Joong;Kim, Min-Gyu;Matsumoto, Toshio
    • Journal of Astronomy and Space Sciences
    • /
    • 제29권3호
    • /
    • pp.305-313
    • /
    • 2012
  • We conducted thermal analyses and cooling tests of the space observation camera (SOC) of the multi-purpose infrared imaging system (MIRIS) to verify passive cooling. The thermal analyses were conducted with NX 7.0 TMG for two cases of attitude of the MIRIS: for the worst hot case and normal case. Through the thermal analyses of the flight model, it was found that even in the worst case the telescope could be cooled to less than $206^{\circ}K$. This is similar to the results of the passive cooling test (${\sim}200.2^{\circ}K$). For the normal attitude case of the analysis, on the other hand, the SOC telescope was cooled to about $160^{\circ}K$ in 10 days. Based on the results of these analyses and the test, it was determined that the telescope of the MIRIS SOC could be successfully cooled to below $200^{\circ}K$ with passive cooling. The SOC is, therefore, expected to have optimal performance under cooled conditions in orbit.

태양열 냉.난방 및 급탕 시스템 열성능 (Evaluation of thermal performance for solar cooling and heating system)

  • 곽희열;주홍진;이호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.203-208
    • /
    • 2009
  • This paper presents demonstration study results derived through field testing of a solar assisted cooling and heating system for the library of a cultural center building located in Gwangju, Korea. The area of demanded cooling and heating for building was about 350m2. Solar hot water was delivered by means of a 200m2 array of evacuated tubular solar collector (ETSC) to drive a single-effect (LiBr/H2O) absorption chiller of 10RT nominal cooling capacity. From March in 2008 to February in 2009, demonstration test were performed for solar cooling and heating system. After experiments and analysis, this study found that solar thermal system was 84% for the solar hot water supply and 12% for space heating and 4% for space cooling.

  • PDF

시험공간에 대한 냉방부하 실증실험 및 계산 (Verification Experiment and Calculation of Cooling Load for a Test Space)

  • 유호선;현석균;김용식;홍희기
    • 설비공학논문집
    • /
    • 제15권8호
    • /
    • pp.641-651
    • /
    • 2003
  • In order to assess the reliability of a building energy simulation program (TRNSYS) from the standpoint of user, a set of verification experiment and calculation of cooling load for a test space is carried out. This work is a complement of the previous study that dealt with heating load for the same space. The test space is kept airtight to eliminate the source of uncertainties in modeling. A window-mounted, on/off controlled air-conditioner is used for cooling, whose performance has been established a priori. The calculation encompasses two models for evaluating cooling load in TRNSYS: energy rate control and temperature level control. Comparison of the total cooling loads obtained from different sets of experimental data enables to validate the measurements. The experimental result shows that the latent load is fairly large even in the absence of apparent air change in the space, which needs to be clarified. Each of hourly and daily accumulated sensible loads is compared between the experiment and two calculation models. Despite an inconsistency associated with solar irradiation, both of the models agree favorably with the experiment within a tolerance, illustrating their capability of properly predicting space thermal loads.

A Preliminary Analysis of the Impact of Urban Green Spaces on the Urban Heat Island Effect Using a Temperature Map

  • Myeong, Soo-Jeong
    • 대한원격탐사학회지
    • /
    • 제26권6호
    • /
    • pp.675-680
    • /
    • 2010
  • Temperature is one of the main issues in climate change, and the urban heat island effect in highly developed urban areas is an important issue that we need to deal with. This study analyzed the extent of the cooling effects of urban green spaces. The study used a surface temperature map of Seoul. It found that the cooling effects of green space was observed within limited distances, although it varied a little depending on the parks investigated. The cooling effect distance ranged from 240m to 360m, averaging about 300m. It also found the size of an urban green space does not make much difference in cooling the surrounding areas. Although further investigation with diverse urban areas should be conducted on this matter, the results did imply that many small green spaces in the neighborhood are more effective than a single big green space in mitigating the heat island effects of cities.

시험공간에 강제환기를 고려한 냉방부하의 실증실험 및 시뮬레이션 (Verification Experiment and Simulation of Cooling Load for a Test Space with Forced Ventilation)

  • 김동혁;유호선;홍희기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.217-222
    • /
    • 2005
  • Building energy consumption according to the ventilation has been considered to be an important subject. The purpose of this study is to investigate the cooling loads in a test space with a forced ventilating system. In the test space, on/off controlled air-conditioning and forced ventilating facility were operated between 8:30 to 21:00 during 4 days and some important data like temperatures and energy consumption were measured to obtain actual cooling loads. The simulation was carried out in a mode of temperature level control using a TRNSYS 15.3 with a precisely measured air change amount and performance data of air-conditioner. Cooling loads including sensible and latent were compared between by experiment and by simulation. Both of cooling loads associated with ventilation show a close agreement within an engineering tolerance.

  • PDF

케로신과 액체산소를 추진제로 하는 10톤급 액체로켓엔진의 재생냉각 특성 평가 (Evaluation on the Regenerative Cooling Characteristics in Liquid Rocket Engine of 10tf-thrust using Kerosene and Liquid Oxygen as a Propellant)

  • 한풍규;조원국;조용호
    • 한국항공우주학회지
    • /
    • 제32권4호
    • /
    • pp.111-117
    • /
    • 2004
  • 케로신과 액체산소를 추진제로 하며, 10톤을 설계 추력으로 하는 우주 발사체의 2단용 액체로켓엔진의 재생 냉각 특성에 대한 해석적 연구를 수행하였다. 또한 보조적인 냉각 방법으로서 노즐 확장부에는 대기로의 복사 방열에 의한 냉각을 적용하였다. 본 연구를 통해, 케로신을 연료로 하는 10톤 추력의 2단용 액체로켓엔진에서 재생냉각과 복사 냉각에 의한 냉각 기구만으로는 소재의 열 및 열구조적인 불안정성과 냉각채널에서의 과다한 압력강하에 의해 적합하지 않다는 것을 확인하였다.

도시 열저감 관점에서의 오픈스페이스 토지이용 공간패턴분석 (Open Space Spacial Pattern Analysis from the Perspective of Urban Heat Mitigation)

  • 강상준
    • 환경영향평가
    • /
    • 제33권4호
    • /
    • pp.155-163
    • /
    • 2024
  • 연구목적은 오픈스페이스 토지이용 공간패턴이 도시 열저감 관점에서 어떤 의미를 갖는지 토지이용 시나리오를 이용하여 가능성 수준에서 살펴보는 것이다. 연구방법은 다음과 같다: (1) InVEST Urban Cooling Model을 이용, 5개 토지이용 시나리오별 Cooling Capacity Index 산출, (2) Guidos Spatial Pattern Toolbox를 사용, 토지이용 시나리오별 각각의 오픈스페이스 Entropy와 형태학적 공간패턴 산출, (3) InVEST 결과값과 Guidos 결과값들의 Spearman rank correlation analysis. 연구결과는 다음과 같다. Cooling Capacity Index와 오픈스페이스 면적비 순위 상관성은 보통이며(rho=0.50), 그 외 지표들은 낮은 것으로 나타났다. 이는 도시 열저감 관점에서는 오픈스페이스 총량만이 큰 의미를 가질 가능성이 있으며, 그 외 오픈스페이스 입지 공간패턴은 도시 열환경 관리 관점에서 큰 의미는 없을 수 있다는 가능성이 관찰되었다.

수원시 녹지 조성 및 주변 환경에 따른 녹지 냉각 효과의 변화 (Variation of Green Space Cooling Effect Influenced by Its Composition and Surroundings in Suwon City)

  • 이승연;전성우
    • 환경영향평가
    • /
    • 제32권3호
    • /
    • pp.176-186
    • /
    • 2023
  • 도시열섬(Urban Heat Island; UHI)은 도시가 인근 지역에 비해 뜨거운 현상을 의미하며 도시 내부의 건물의 구성, 토지피복의 종류 등이 변화하기 때문에 발생한다. 도시열섬을 완화하기 위한 방법으로 녹지공간의 조성인데, 녹지가 제공하는 냉각효과의 경우 녹지의 내부 구성 요소 및 녹지의 크기에 따라 변화한다. 본 연구는 다양한 토지피복으로 구성된 수원시를 대상으로 녹지의 크기와 녹지를 구성하는 요소들에 따른 냉각효과의 차이를 확인하고, 녹지의 인근 토지피복에 따라 녹지로부터 제공되는 냉각효과의 차이를 고찰하고자 한다. 연구 결과, 녹지의 초기 온도는 산림의 비율이 높을수록, 그리고 호수가 존재할수록 낮아졌다. 냉각효과 중 하나인 냉각강도는 숲의 비율이 높을수록 강해졌지만, 초기 온도가 더 큰 영향을 미쳤다. 다만 냉각 거리는 녹지의 크기나 구성에 따라 달라지지 않음을 확인했다. 본 연구의 결과는 도시의 계획 시 열섬을 완화하기 위한 녹지 설계 방안을 제시한 다는 점에 의의를 가진다.

건물예냉과 실내온도의 선형상승에 의한 피크냉방수요 저감 (Reducing Peak Cooling Demand Using Building Precooling and Modified Linear Rise of Indoor Space Temperature)

  • 이경호;양승권;한승호
    • 설비공학논문집
    • /
    • 제22권2호
    • /
    • pp.86-96
    • /
    • 2010
  • The paper describes development and evaluation of a simple method for determining gradient of modified linear setpoint variation to reduce peak electrical cooling demand in buildings using building precooling and setpoint adjustment. The method is an approximated approach for minimizing electrical cooling demand during occupied period in buildings and involves modified linear adjustment of cooling setpoint temperature between $26^{\circ}C$ and $28^{\circ}C$. The gradient of linear variation or final time of linear increase is determined based on the cooling load shape in conventional cooling control having a constant setpoint temperature. The potential to reduce peak cooling demand using the simple method was evaluated through building simulation for a calibrated office building model considering four different weather conditions. The simple method showed about 30% and 20% in terms of reducing peak cooling demand and chiller power consumption, respectively, compared to the conventional control.