• Title/Summary/Keyword: Space Rate

Search Result 3,314, Processing Time 0.033 seconds

Setup of Infiltration Galleries and Preliminary Test for Estimating Its Effectiveness in Sangdae-ri Water Curtain Cultivation Area of Cheongju, Korea (청주 상대리 수막재배지의 지중 침투형 갤러리 설치와 예비 주입시험)

  • Moon, Sang-Ho;Kim, Yongcheol;Kim, Sung-Yun;Ki, Min-Gyu
    • Economic and Environmental Geology
    • /
    • v.49 no.6
    • /
    • pp.445-458
    • /
    • 2016
  • Most of water curtain cultivation (WCC) area in Korea has been inveterately suffering from the gradual draw-down of groundwater level and related shortage of water resources at the late stage of WCC peak time. To solve this problem, artificial recharge techniques has been recently applied to some WCC area. This study introduces infiltration gallery, which is one of the artificial recharge methods, and tentatively examined the effectiveness of three galleries installed at Sangdae-ri WCC area of Cheongju City. Seven galleries are set up at each empty space between eight vinyl houses in this area and its dimension is designed as 50 cm in each width and height and 300 cm in each length. Installation process was including bed excavation, backfill with gravels and silica sands, and completion of gallery by equipment of piezometer and covering with non-woven cloth. For each B, C, D gallery, 3 types of test including preliminary, four step and one long-term injection were performed. The first preliminary test showed the rough relations between injection rates and water level rise as follows; 20 cm and 30 cm level rise for $33.29{\sim}33.84m^3/d$ and $45.60{\sim}46.99m^3/d$ in B gallery; 0 cm, 16 cm and 33 cm level rise for $21.1m^3/d$, $33.98m^3/d$ and $41.69m^3/d$ in C gallery; 29 cm and 42 cm level rise for $48.10m^3/d$ and $52.23m^3/d$ in D gallery. Afterwards, more quantitative results estimating effectiveness of artificial recharge were reasoned out through stepped and long-term injection tests, which is expected to be employed for estimating water quantity re-injected into the aquifer through these galleries by natural injection over the period of WCC peak time.

The Influence of the Landscaping Shade Membrane's Brightness on the Mean Radiant Temperature(MRT) of Summer Outdoor (조경용 차양막 재료의 명도가 하절기 옥외공간의 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.5
    • /
    • pp.65-73
    • /
    • 2015
  • The purpose of this study was to compare the Mean Radiant Temperature(MRT) under two landscaping shade membranes, white and black, with those of natural outdoor spaces at summer midday. An additional perforated black shading net was applied and compared for the consideration of the practical application. The average MRT at the height of 2.4m, 10cm below the membranes of black, white, and perforated black were $49.1^{\circ}C$, $41.6^{\circ}C$ and $36.8^{\circ}C$ respectively, while that of open sky was $41.8^{\circ}C$. This indicates that a closer position to the darker membrane caused a higher MRT. At the height of 1.1m and 1.7m, the difference of MRT between the black and the white membranes was slight, while the value of white was unexpectedly higher than the black. The MRT of black perforated net showed the lowest value at every height. The black membrane absorbed more solar radiation than the white, which caused the greater release of long wave radiation and higher temperature near the membrane itself. In spite of the higher albedo of the white membrane, the higher solar radiation transmittance rate of which seemed to cause the slightly higher MRT than the black at the hight of 1.1m and 1.7m. In summary, the performance of the black membrane was slightly better than the white in terms of the air conditioning of the human related space around the height of 1.1m and 1.7m, when the shading membranes were at 2.5m height.

ERUPTION PATTERN OF A CYST-ASSOCIATED MANDIBULAR PREMOLAR AFTER MARSUPIALIZATON OF A DENTIGEROUS CYST (함치성 낭의 조대술 후 이환치아의 맹출 양상)

  • Kim, Joo-Young;Kim, Hyeun-Jung;Kim, Young-Jin;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.373-384
    • /
    • 2003
  • The purpose of this study was to evaluate the eruption pattern of a cyst-associated mandibular premolar after marsupialization of a dentigerous cyst in children. The result from the twenty two pairs of normalized panoramic radiographs of twenty two patients who underwent neither extraction nor orthodontic traction of the cyst-associated mandibular after marsupialization were as follows. 1. The eruption speed of a cyst-associated premolar was 3.5 times faster than that of the normal contra-lateral premolar(p<0.05). The angulation change of test group was an average of $2.7^{\circ}$ per month. 2. In the change of the level of root formation, the group which had a little root maturity tended to be faster in the eruption speed(p>0.05) and the R1/4 group had a great change in the angulation change(p>0.05). 3. In the change to be with the cusp position index, the eruption speeds were increased to the 30% deviation groups. But, the eruption speed was decreased above that(p>0.05). 4. Group with cyst diminishment rate of more than $80mm^2$ per month showed the fastest eruption speed of all(p<0.05). 5. The mesial angulated teeth in the test group were decreased more rapidly than the distal angulated teeth in the eruption speed(p>0.05). But, increased in the angulation change(p<0.05). 6. There was a tendency of faster tooth eruption with less deviation of tooth axis. Group with tooth axis deviation of less than $15^{\circ}$ showed the fastest angulation change of all(p<0.05). 7. The eruption speed and the angulation change rapidly decreased during the first 6 months following marsupialization. Based on the results of this study, a cyst-associated mandibular premolar erupted more rapidly after marsupializaton. We thought so that it's prognosis was good if the tooth had a little root maturity, a little devitation and cyst lesion healed faster. We recommend that if there is enough space for eruption, orthodontic traction and surgical treatment of the cyst-associated tooth should be postponed 6 months after marsupialization.

  • PDF

Effects of Electric Stimulation and Activation Conditions on the Fusion and Development of Porcine Somatic Cell Nuclear Transfer Embryos (전기적 융합과 활성화 방법이 돼지 체세포 복제수정란의 체외발달에 미치는 영향)

  • 정기화
    • Journal of Embryo Transfer
    • /
    • v.19 no.1
    • /
    • pp.43-51
    • /
    • 2004
  • The present study was conducted to investigate the effects of fusion and/or activation protocol on in vitro development of porcine somatic cell nuclear transfer (SCNT) embryos. Porcine fetal fibroblast cells were transferred into the perivitelline space of enucleated in vitro matured oocytes. Cell fusion and activation were induced simultaneous fusion/activation (SA) or delayed activation (DA) with or without cytochalasin B (CB) treatment with electic pulses in 0.28 M mannitol-based medium. The SCNT embryos were cultured in vitro for 7 days and stained with Hoechst 33342 to determine the number of nuclei. After 7 days culture, cleavage and blastocyst formation rates were 72.4% and 7.6% in SCNT and 76.3% and 20.4% in parthenotes. To examine the effect of electric field strengths on development of SCNT embryos, oocytes were fused two pulses of 110 V/mm, 130 V/mm or 150 V/mm for 30 sec post-injection. The fusion and cleavage rates in 130 V/mm group (70.2% and 72.6%) and 150 V/mm group (72.6% and 70.5%) were higher (P<0.05) than 110 V/mm group (47.1% and 48.6%), respectively. However, the rate of embryos developing to the blastocyst stage (8.1%, 9.7% and 10.7%) were not different among three groups. The cleavage rates and the blastcyst formation rates were not different among three treatment groups (SA group, 71.4% and 9.7%; SA+CB treatment group, 74.7% and 8.0%; DA+CB treatment group, 70.8% and 11.2%, respectively). And, no different in the number of cells in blastocysts was observed among the three groups (22.5$\pm$12.8, 23.3$\pm$11.2 and 21.6$\pm$10.4, respectively). These result suggest that two pulses of 130 V/mm or 150 V/mm for 30 sec with SA treatment or DA treatment are enough for fusion/activation of porcine somatic cell nuclear transfer (SCNT) embryos to develop to the blastocyst stage.

Studies on the drought resistance of mulberry trees (상수의 내건성에 관한 연구)

  • 김문협
    • Journal of Sericultural and Entomological Science
    • /
    • v.7
    • /
    • pp.1-26
    • /
    • 1967
  • In order to develop the standards for the measurement of drought resistance in mulberry trees (Morus genus) the varietal differences of drought resistance were measured for 30 mulberry varieties, and the relationships between the drought resistance and the histological and physiological characteristics of mulberry leaves were investigated. The results were summarized as follows; 1. It is reasonable to use the drought resistance ratio, expressed by D/D'*100, for the standard of drought resistance measurement for mulberry tree as a perennial tree crop. Where: D stands for growth amount(shoot length) in the plot of dry treatment, at the end of treatment. D' stands for an expected value of D which is expressed by B*C/A. Here, A is the growth amount of wet treatment plot at the beginning of treatment, B is the growth amount of dry treatment plot at the beginning of treatment, and C is the growth amount of wet treatment plot at the end of treatment. 2. The results obtained from the application of above formula showed that the varieties Cadaneo, Tahozosaeng, Yongchunchuwu, Kaeryang suban. and Kabsun were highly resistant to drought and the varieties Jukmok, Shipyung, Sobun, Kaeryangzosaeng shipmoonza and Chungagokyo were highly susceptible. 3. Among leaf tissues. the rate of inter-cellular space showed the highest relationship with drought resistance. The correlation coefficient calculated (r=0.4153) was highly significant. Other leaf tissues such as epidermis and palisade showed no significant correlations with drought resistance. 4. The size and density of stomata were correlated to drought resistance. That is: Correlation between drought resistance and size of stomata(length ${\times}$ width)......r= -0. 3253(signif. at 5%) density(No. of stomata/l$\textrm{mm}^2$......r= +0.5047(signif. at 1%)

  • PDF

Review of Policy Direction and Coupled Model Development between Groundwater Recharge Quantity and Climate Change (기후변화 연동 지하수 함양량 산정 모델 개발 및 정책방향 고찰)

  • Lee, Moung-Jin;Lee, Joung-Ho;Jeon, Seong-Woo;Houng, Hyun-Jung
    • Journal of Environmental Policy
    • /
    • v.9 no.2
    • /
    • pp.157-184
    • /
    • 2010
  • Global climate change is destroying the water circulation balance by changing rates of precipitation, recharge and discharge, and evapotranspiration. The Intergovernmental Panel on Climate Change (IPCC 2007) makes "changes in rainfall pattern due to climate system changes and consequent shortage of available water resource" a high priority as the weakest part among the effects of human environment caused by future climate changes. Groundwater, which occupies a considerable portion of the world's water resources, is related to climate change via surface water such as rivers, lakes, and marshes, and "direct" interactions, being indirectly affected through recharge. Therefore, in order to quantify the effects of climate change on groundwater resources, it is necessary to not only predict the main variables of climate change but to also accurately predict the underground rainfall recharge quantity. In this paper, the authors selected a relevant climate change scenario, In this context, the authors selected A1B from the Special Report on Emission Scenario (SRES) which is distributed at Korea Meteorological Administration. By using data on temperature, rainfall, soil, and land use, the groundwater recharge rate for the research area was estimated by period and embodied as geographic information system (GIS). In order to calculate the groundwater recharge quantity, Visual HELP3 was used as main model for groundwater recharge, and the physical properties of weather, temperature, and soil layers were used as main input data. General changes to water circulation due to climate change have already been predicted. In order to systematically solve problems associated with how the groundwater resource circulation system should be reflected in future policies pertaining to groundwater resources, it may be urgent to recalculate the groundwater recharge quantity and consequent quantity for using via prediction of climate change in Korea in the future and then reflection of the results. The space-time calculation of changes to the groundwater recharge quantity in the study area may serve as a foundation to present additional measures for the improved management of domestic groundwater resources.

  • PDF

Hydro-Mechanical Modelling of Fault Slip Induced by Water Injection: DECOVALEX-2019 TASK B (Step 1) (유체 주입에 의한 단층의 수리역학적 거동 해석: 국제공동연구 DECOVALEX-2019 Task B 연구 현황(Step 1))

  • Park, Jung-Wook;Park, Eui-Seob;Kim, Taehyun;Lee, Changsoo;Lee, Jaewon
    • Tunnel and Underground Space
    • /
    • v.28 no.5
    • /
    • pp.400-425
    • /
    • 2018
  • This study presents the research results and current status of the DECOVALEX-2019 project Task B. Task B named 'Fault slip modelling' is aiming at developing a numerical method to simulate the coupled hydro-mechanical behavior of fault, including slip or reactivation, induced by water injection. The first research step of Task B is a benchmark simulation which is designed for the modelling teams to familiarize themselves with the problem and to set up their own codes to reproduce the hydro-mechanical coupling between the fault hydraulic transmissivity and the mechanically-induced displacement. We reproduced the coupled hydro-mechanical process of fault slip using TOUGH-FLAC simulator. The fluid flow along a fault was modelled with solid elements and governed by Darcy's law with the cubic law in TOUGH2, whereas the mechanical behavior of a single fault was represented by creating interface elements between two separating rock blocks in FLAC3D. A methodology to formulate the hydro-mechanical coupling relations of two different hydraulic aperture models and link the solid element of TOUGH2 and the interface element of FLAC3D was suggested. In addition, we developed a coupling module to update the changes in geometric features (mesh) and hydrological properties of fault caused by water injection at every calculation step for TOUGH-FLAC simulator. Then, the transient responses of the fault, including elastic deformation, reactivation, progressive evolutions of pathway, pressure distribution and water injection rate, to stepwise pressurization were examined during the simulations. The results of the simulations suggest that the developed model can provide a reasonable prediction of the hydro-mechanical behavior related to fault reactivation. The numerical model will be enhanced by continuing collaboration and interaction with other research teams of DECOLVAEX-2019 Task B and validated using the field data from fault activation experiments in a further study.

Replacement of Saline Water through Injecting Fresh Water into a Confined Saline Aquifer at the Nakdong River Delta Area (염수로 충진된 낙동강 델타지역 피압대수층에서 담수주입에 의한 염수치환 연구)

  • Won, Kyung-Sik;Chung, Sang Yong;Lee, Chang-Sup;Jeong, Jae-Hoon
    • The Journal of Engineering Geology
    • /
    • v.25 no.2
    • /
    • pp.215-225
    • /
    • 2015
  • We performed injection tests in a deep-seated confined aquifer to assess the potential of artificial recharge as a means of preventing saltwater contamination, thereby securing groundwater resources for the Nakdong Delta area of Busan City, Korea. The study area comprises a confined aquifer, in which a 10-21-m-thick clay layer overlies 31.5-36.5 m of sand and a 2.8-11-m-thick layer of gravel. EC logging of five monitoring wells yielded a value of 7-44 mS/cm, with the transition between saline and fresh water occurring at a depth of 15-38 m. Above 5 m depth, water temperature is 10-15.5℃, whereas between 5 and 50 m depth the temperature is 15.5-17℃. Approximately 950 m3 of fresh water was injected into the OW-5 injection well at a rate of 370 m3/day for 62 hours, after which the fresh water zone was detected by a CTD Diver installed at a depth of 40 m. The persistence of the fresh water zone was determined via EC and temperature logging at 24 hours after injection, and again 21 days after injection. We observed a second fresh water zone in the OW-2 well, where the first injection test was performed more than 20 days before the second injection test. The contact between fresh and saline water in the injection well is represented by a sharp boundary rather than a transitional boundary. We conclude that the injected fresh water occupied a specific space and served to maintain the original water quality throughout the observation period. Moreover, we suggest that artificial recharge via long-term injection could help secure a new alternative water resource in this saline coastal aquifer.

A Study on the Neutron in Radiation Treatment System and Related Facility (방사선치료 장치 및 관련시설에서의 산란 중성자에 관한 연구)

  • Kim Dae-Sup;Kim Jeong-Man;Lee Hee-Seok;Lim Ra-Seung;Kim You-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.141-145
    • /
    • 2005
  • Purpose : It is known that the neutron is generally generated from the photon, its energy is larger than 10 MV. The neutron is leaked in the container inspection system installed at the customs though its energy is below 9 MV. It is needed that the spacial effect of the neutrons released from radiation treatment machine, linac, installed in the medical canter. Materials and Methods : The medical linear accelerator(Clinac 1800, varian, USA) was used in the experiment. Measuring neutron was used bubble detector(Bubble detector, BDPND type, BTI, Canada) which was created bubble by neutron. The bubble detector is located on the medical linear accelerator outskirt in three different distance, 30, 50, 120 cm and upper, lower four point from the iso-center. In addition, for effect on protect material we have measured eight points which are 50 cm distance from iso-center. The SAD(source-axis-distance), distance from photon source to iso-center, is adjusted to 100 cm and the field size is adjusted to $15{\times}15cm^2$. Irradiate 20 MU and calculate the dose rate in mrem/MU by measuring the number of bubble. Results : The neutron is more detected at 5 position in 30, 50 cm, 7 position in 120 cm and with wedge, and 2 position without mount. Conclusion : Though detection position is laid in the same distance in neutron measurement, the different value is shown in measuring results. Also, neutron dose is affected by the additional structure, the different value is obtained in each measurement positions. So, it is needed to measure and evaluate the neutron dose in the whole space considering the effect of the distance, angular distribution and additional structure.

  • PDF

Application of CMP Process to Improving Thickness-Uniformity of Sputtering-deposited CdTe Thin Film for Improvement of Optical Properties (스퍼터링 증확 CdTe 박막의 두께 불균일 현상 개선을 위한 화학적기계적연마 공정 적용 및 광특성 향상)

  • Park, Ju-Sun;Lim, Chae-Hyun;Ryu, Seung-Han;Myung, Kuk-Do;Kim, Nam-Hoon;Lee, Woo-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.375-375
    • /
    • 2010
  • CdTe as an absorber material is widely used in thin film solar cells with the heterostructure due to its almost ideal band gap energy of 1.45 eV, high photovoltaic conversion efficiency, low cost and stable performance. The deposition methods and preparation conditions for the fabrication of CdTe are very important for the achievement of high solar cell conversion efficiency. There are some rearranged reports about the deposition methods available for the preparation of CdTe thin films such as close spaced sublimation (CSS), physical vapor deposition (PVD), vacuum evaporation, vapor transport deposition (VTD), closed space vapor transport, electrodeposition, screen printing, spray pyrolysis, metalorganic chemical vapor deposition (MOCVD), and RF sputtering. The RF sputtering method for the preparation of CdTe thin films has important advantages in that the thin films can be prepared at low growth temperatures with large-area deposition suitable for mass-production. The authors reported that the optical and electrical properties of CdTe thin film were closely connected by the thickness-uniformity of the film in the previous study [1], which means that the better optical absorbance and the higher carrier concentration could be obtained in the better condition of thickness-uniformity for CdTe thin film. The thickness-uniformity could be controlled and improved by the some process parameters such as vacuum level and RF power in the sputtering process of CdTe thin films. However, there is a limitation to improve the thickness-uniformity only in the preparation process [1]. So it is necessary to introduce the external or additional method for improving the thickness-uniformity of CdTe thin film because the cell size of thin film solar cell will be enlarged. Therefore, the authors firstly applied the chemical mechanical polishing (CMP) process to improving the thickness-uniformity of CdTe thin films with a G&P POLI-450 CMP polisher [2]. CMP process is the most important process in semiconductor manufacturing processes in order to planarize the surface of the wafer even over 300 mm and to form the copper interconnects with damascene process. Some important CMP characteristics for CdTe were obtained including removal rate (RR), WIWNU%, RMS roughness, and peak-to-valley roughness [2]. With these important results, the CMP process for CdTe thin films was performed to improve the thickness-uniformity of the sputtering-deposited CdTe thin film which had the worst two thickness-uniformities of them. Some optical properties including optical transmittance and absorbance of the CdTe thin films were measured by using a UV-Visible spectrophotometer (Varian Techtron, Cary500scan) in the range of 400 - 800 nm. After CMP process, the thickness-uniformities became better than that of the best condition in the previous sputtering process of CdTe thin films. Consequently, the optical properties were directly affected by the thickness-uniformity of CdTe thin film. The absorbance of CdTe thin films was improved although the thickness of CdTe thin film was not changed.

  • PDF