• 제목/요약/키워드: Space Geodesy

검색결과 265건 처리시간 0.022초

수치사진측량 기반 3차원영상생성 정확도 분석 (The Accuracy Analysis of 3D Image Generation by Digital Photogrammetry)

  • 강준묵;엄대용;임영빈
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2003년도 추계학술발표회 논문집
    • /
    • pp.157-162
    • /
    • 2003
  • The 3D Image which embodies real object to 3D space of computer enables various geometrical analysis as well as visualization of complex 3D shape by giving sense for the real and cubic effect that can not be offered in 2D image. Human gives real object to same physical properties in 3D space imagination world of computer, and it is expected that this enables offering of various information by user strengthening interface between human-computer to observe object in real condition. In this study, formal style routine of 3D image creation applying digital photogrammetry was designed for more practical, highly trusty 3D image creation, and the system was emboded using object-oriented technique which strengthen user interface. Also, the discontinuity information about rock slope using 3D image is acquired that is orientation, persistence, spacing and aperture etc.

  • PDF

고해상도 위성영상의 지상위치 정확도 개선을 위한 다항식 보정 프로그램의 개발 (Development of a Polynomial Correction Program for Accuracy Improvement of the Geopositioning of High Resolution Imagery)

  • 이진덕;소재경
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2007년도 춘계학술발표회 논문집
    • /
    • pp.135-140
    • /
    • 2007
  • Due to the expensiveness of IKONOS Pro and Precision Products, it is attractive to use the low-cost IKONOS Geo Product with vendor-provided RPCs to produce highly accurate mapping products. The imaging geometry of IKONOS high-resolution imagery is described by RFs instead of rigorous sensor models. This paper presents four different models defined respectively in object space and image space to improve the accuracies of the RF-derived ground coordinates. The four models include the offset model, the scale & offset model, the affine model and the 2nd-order polynomial model. Different configurations of ground control points (GCPs) are carefully examined to evaluate the effect of the GCPs arrangement on the accuracy of ground coordinates. The experiment also evaluates the effect of different cartographic parameters such as the number location, and accuracy of GCPs on the accuracy of geopositioning.

  • PDF

Global Magnetohydrodynamic Simulation of a Comet : When a Comet Crosses a Heliopheric Sector Boundary

  • Yu, Yi
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • 제22권1호
    • /
    • pp.6-23
    • /
    • 1994
  • A disconnection event (DE) of the cometary plasma tail is one of most spectacular phenomena observed in comets. Yet, for years it has remained one of the great unsolved problems I astronomy and space physics. The solar wind is thought to play a major role in the creation of comet plasma tail (type Ⅰ) disconnection events. The goal of this paper is to present a mechanism that explains the disconnection event in terms of the local conditions at the comet. Comparison of the solar wind conditions and 16 DEs in Halley's comet shows that DEs are associated primarily with crossings of the heliospheric sector boundary and apparently not with any other properties of the solar wind, such as a high speed stream[Yi et al., 1994]. A 3-dimensional resistive magnetohydrodynamic simulation in this paper supports this association by showing that only front-side magnetic reconnection between the reversed interplanetary magnetic fields that exist when a comet crosses the heliospheric sector boundary [Niedner and Brandt, 1978] could reproduce the morphology of a DE, including ray formation [Brandt, 1982].

  • PDF

Rational function model-based image matching for digital elevation model

  • 박정환
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2005년도 추계학술대회
    • /
    • pp.59-80
    • /
    • 2005
  • This Paper Presents a Rational Function Model (RFM)-based image matching technique for IKONOS satellite imagery. This algorithm adopts the object-space approach and reduces the search space within the confined line-shaped area called the Piecewise Matching Line (PLM). Also, the detailed procedure of generating 3-D surface information using the Rational Function model Coefficients (RFCs) is introduced as an end-user point of view. As a result, the final generated Digital Elevation Model (DEM) using the proposed scheme shows a mean error of 2$\cdot$2 m and RMSE of 3$\cdot$8 m compared with that from 1:5000 digital map.

  • PDF

3차원 정밀지형자료의 토공계획 활용 (An application for earthwork system using the precise 3D spatial data)

  • 이진녕;편무욱;구지희;이영균
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2010년 춘계학술발표회 논문집
    • /
    • pp.419-422
    • /
    • 2010
  • In this study, I executed civil engineering design and compared it with the existing method in order to analyze the expected effect of civil engineering design by using three dimensional space information and its advantages. Through a series of processes, it is possible to enhance the usability of three-dimensional space information, expected more accurate calculation of earth work and proceed with more reasonable construction in soil conversion and civil engineering work. Also, it enables improvement of productivity by establishing efficient construction plan.

  • PDF

GPS 관측을 통한 한반도 서해안 지역의 해수하중에 의한 지각변위 검출 가능성 조사 (Feasibility Study for Detecting Ocean Loading Displacements in the Western Costal Area of Korea Using GPS Measurements)

  • 박관동;임형철
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2004년도 춘계학술발표회논문집
    • /
    • pp.33-38
    • /
    • 2004
  • The ocean loading displacement of the crust is one of the major error sources in space geodesy techniques. In the western part of the Korean Peninsula, the vertical displacement due to ocean loading reaches up to 3cm. To check out the possibility of correcting the inaccurate ocean tide model in the Yellow Sea, we used four GPS sites to compute the height variations and compared them with the model-predicted ones. The comparison shows relatively good agreement except for small differences in the phase and amplitude.

  • PDF

Merging Two Regional Geoid Estimates by Using Optimal Variance Components of Type repro-BIQUUE: An Algorithmic Approach

  • SCHAFFRIN Burkhard;MAUTZ Rainer
    • Korean Journal of Geomatics
    • /
    • 제5권1호
    • /
    • pp.1-6
    • /
    • 2005
  • When merging various datasets the perennial problem of relative weighting arises. In case of two datasets an iterative algorithm has been developed recently that allows the rigorous determination of optimal variance components of type repro-BIQUUE even for large amounts of data, along with the estimation of the joint parameters. Here we shall present this new algorithm, and show its versatility in an example that will entail the merging of two regional geoid estimates (derived from EGM 96 and CHAMP) in terms of certain series expansions which have been proven previously to belong to the most efficient ones (e.g., wavelets, Hardy's multi-quadrics, etc.). Future attempts will be devoted to the sequential merging of altimeter and tide gauge data.

  • PDF

GPS를 이용한 전리층 토모그래피 모델 개발 (DEVELOPMENT OF IONOSPHERIC TOMOGRAPHY MODEL USING GPS)

  • 최병규;박종욱;이상정
    • Journal of Astronomy and Space Sciences
    • /
    • 제23권3호
    • /
    • pp.237-244
    • /
    • 2006
  • 한국천문연구원에서 운영중인 9개의 GPS(Global Positioning System) 상시관측소 데이터를 이용하여 한반도 상공의 고도에 따른 전리층 내의 전자밀도 분포를 산출하였다. 전리층의 전자 밀도를 정밀하게 추정하기 위해 이중주파수(L1,L2) 데이터가 사용되었고, 2차원 총전자수(Total Electron Contents, TEC)값을 기반으로 정밀한 전자 밀도 분포를 얻을 수 있었다. 그리고 토모그래피 모델개발에 널리 사용되고 있는 Inversion 기법 중의 하나인 ART(Algebraic Reconstruction Technique) 알고리즘을 적용하였다. 본 연구에서는 지역적 GPS 관측망을 활용하여 시간에 따른 한반도 상공의 전자밀도 분포 유형을 제시하였고, GPS에 의한 전리층 재구성으로 얻어진 전자밀도 유형을 경험적 모델인 IRI-2001에 의해 계산된 값과 관측으로부터 얻어진 Ionosonde 관측값을 서로 비교하였다. 그 결과 GPS 재구성에 의한 전자밀도 분포 유형이 Ionosonde에 의한 관측값과 잘 일치하는 경향을 보였다.

실내공간의 연결성 분석을 통한 고립지역 탐색 (Finding Isolated Zones through Connectivity Relationship Analysis in Indoor Space)

  • 이슬지;이지영
    • 한국측량학회지
    • /
    • 제30권3호
    • /
    • pp.229-240
    • /
    • 2012
  • 유비쿼터스 환경을 구축하기 위하여 우리나라에서는 IT 기반 신도시 건설의 프로젝트인 u-City 사업이 추진되고 있지만, u-City에서 제공해주는 u-service는 USN(Ubiquitous Sensor Network)기반으로 모니터링에 치중하여 공간분석에 관한 서비스가 부재하다. 특히 대규모 복합 건물이 증가로 실내공간에서의 활동시간이 늘어남에 따라 단순한 모니터링이 아닌 3차원 실내 공간분석이 필요하다. 따라서 위상학적 데이터 모델을 기반으로 하여 실내 공간에서의 연결성을 분석하였다. 실내공간에서는 실외공간과 달리 공간 객체간의 연결이 제한적이기 때문에 환경변화에 따라 연결성이 바뀔 수 있고, 이에 따라 공간분석 결과 또한 달라질 수 있다. 본 연구에서는 연결성을 변화시키는 긴급 상황의 대표적인 예로 화재가 발생하였을 경우 연결성을 분석하고, 연결성 변화를 통해 생성될 수 있는 고립지역을 탐색하는 알고리즘을 개발하였다. 개발한 알고리즘을 적용하여 분석 결과를 도출하기 위하여, 실내공간의3차원 구조뿐만 아니라, 고립지역을 가시화하는 시스템을 구현하였다.

GNSS 측위방법에 따른 해양조석하중 성분 검출 정확도 분석 (Accuracy Analysis of Ocean Tide Loading Constituent Detection Using GNSS Positioning)

  • 윤하수;최윤수;권재현
    • 한국측량학회지
    • /
    • 제34권3호
    • /
    • pp.299-308
    • /
    • 2016
  • 오늘날 우주측지기술은 측위정밀도를 높이고 시간과 비용적 측면에서 효율성을 향상시키는 방향으로 발전되고 있다. 정밀측위를 위하여 지구의 물리적 현상을 보정하는 것은 필수적이며, 그 중 해양조석하중의 보정은 중요한 요소이다. 본 연구에서는 인천과 제주의 조위관측소 GNSS 관측데이터를 이용하여 해양조석하중에 의한 수직지각변위를 산출하고 지각변위를 일으키는 각 분조의 조석성분을 검출하였다. GNSS 측위방법과 자료처리 시간에 따른 해양 조석하중 성분 검출 정확도를 비교하기 위하여 상대측위와 정밀절대측위로 GNSS 데이터를 처리하여 주요 8개 조석성분의 진폭을 산출하고 전지구 해양조석하중 모델의 진폭과 비교하였다. 연구결과 조석분조 진폭 검출에는 2시간 간격의 자료처리와 정밀절대측위 방법이 해양조석하중 분조 검출에 정확한 것으로 나타났다. 추후에는 장기간 자료를 이용하여 장주기 조석성분에 대한 분석도 이루어져야 할 것이다.