An Experimental Study on Acoustic Performance of Splitter Silencers in Large Maritime Gas Turbine Engines (해상용 가스터빈의 스플리터 소음기 성능에 대한 실험적 연구)

  • Baek, Seonghyeon;Lee, Kanghee;Kang, Kyungsik;Lee, Iljae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.7
    • /
    • pp.503-509
    • /
    • 2015
  • Based on ISO 7235, an experimental setup to measure the acoustic performance of splitter type dissipative silencers was fabricated. The length of each duct, sound source, microphone locations, modal filter, and anechoic termination were considered in the design of this setup. The modal filter is a particularly important factor because it affects the limit of measurement. The effects of number of splitters, absorptive material density, perforate plate, and media on the noise reduction of the sample silencers were experimentally investigated. The experimental results show that the insertion loss of a silencer with media, high perforate opening, and higher number of splitters increases especially at higher frequencies.

Multiple Buck-Chopper using Partial Resonant Switching

  • Mun Sang-Pil;Suh Ki-Young;Lee Hyun-Woo;Chun Jung-Ham
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.189-192
    • /
    • 2001
  • This paper proposed that an AC-DC converter system using multiple buck-chopper operates with four choppers connecting to a number of parallel circuits. To improve these, a large number of soft switching topologies included a resonant circuit have been proposed. And, some simulative results on computer are included to confirm the validity of the analytical results. The partial resonant circuit makes use of an inductor using step-down and a condenser of loss-less snubber. The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in a partial resonant circuit makes charging energy regenerated at input power source for resonant operation. The proposed conversion system is deemed the most suitable for high power applications where the power switching devices are used.

  • PDF

Transmission Path Analysis of Noise and Vibration in a Rotary Compressor by Statistical Energy Analysis

  • Hwang, Seon-Woong;Jeong, Weui-Bong;Yoo, Wan-Suk;Kim, Kyu-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.11
    • /
    • pp.1909-1915
    • /
    • 2004
  • The hermetic rotary compressor is one of the most important components of an air conditioning system since it has a great effect on both the performance and the noise and vibration of the system. Noise and vibration occurs due to gas pulsation during the compression process and to unbalanced dynamic force. In order to reduce noise and vibration, it is necessary to identify their sources and transmission path and effectively control them. Many approaches have been tried in order to identify the noise transmission path of a compressor. However, identification has proven to be difficult since the characteristics of compressor noise are complicated due to the interaction of the compressor parts and gas pulsation. In this study, the statistical energy analysis has been used to trace the energy flow in the compressor and to identify the transmission paths from the noise source to the exterior sound field.

Islanding Detection Method of Embedded Generator connected to Power Distribution System (분산형전원이 도입된 배전계통에 대한 ISLANDING DETECTION METHOD)

  • Hwang, J.S.;Kim, J.E.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.522-524
    • /
    • 2000
  • The installation of small sized Embedded Generator(EG) in parallel with the utility supply was required several technical complications for protection of the system. One of the most important protection is to provide protection against islanding and out of synchronism reclosing with the utility source. This paper explains several current methods of detecting 'Loss Of Mains'(LOM). But they have not proved completely dependable, in particular when the islanded load's capacity matches that of the EG. A new loss of mains protection algorithm is presented in this paper which based on measurement of the reactive power and node voltage for detecting the islanding condition even though the EG operate in the capacity.

  • PDF

Comparison of High Power Semiconductor Devices in 5MW PMSG MV Wind Turbines

  • Lee, Kihyun;Jung, Kyungsub;Suh, Yongsug;Kim, Changwoo;Cha, Taemin;Yoo, Hyoyol;Park, Sunsoon
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.386-387
    • /
    • 2013
  • This paper provides a comparison of high power semiconductor devices in 5MW-class Permanent Magnet Synchronous Generator (PMSG) Medium Voltage (MV) wind turbines. High power semiconductor devices of IGBT module type, IGBT press-pack type, and IGCT of both 4.5kV and 6.5kV are considered in this paper. Benchmarking is performed based on neutral-point clamed 3-level back-to-back type voltage source converter supplied from grid voltage of 4160V. The feasible number of semiconductor devices in parallel is designed through the loss analysis considering both conduction and switching losses under the given operating conditions of 5MW-class PMSG wind turbines, particularly for the application in offshore wind farms. The loss analysis is confirmed through PLECS simulations. The comparison result shows that IGBT press-pack type semiconductor device has the highest efficiency and IGCT has the lowest cost factor considering the necessary auxiliary components.

  • PDF

3-Level T-type Inverter Operation Method Using Level Change

  • Kim, Tae-Hun;Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.263-269
    • /
    • 2018
  • In this study, a selective inverter operation between a 2-level voltage source converter (VSC) and a 3-level T-type VSC (3LT VSC) is proposed to improve the efficiency of a 3LT VSC. The 3LT VSC topology, except for its neutral-point switches, has similar operations as that of the 2-level VSC. If an operation mode is changed according to efficiency, the efficiency can be improved because efficiencies of each methods are depending on current and MI (Modulation Index). The proposed method calculates the power losses of the two topologies and operates as the having lower losses. To calculate the losses, the switching and conduction losses based on the operation mode of each topology were analyzed. The controller determined the operation mode of the 2- or 3-level VSC based on the power loss calculated during every cycle. The validity of the proposed control scheme was investigated through simulation and experiments. The waveform and average efficiency of each method were compared.

A study on performance improvement of natural gas fueled engine (천연가스 기관의 성능 향상에 관한 연구)

  • 정동수;정진도;서승우;최교남
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.175-179
    • /
    • 1992
  • Generally speaking, natural gas possesses several characteristics that make it desirable as an engine fuel : for example (1) lower production cost, (2) abundant commodity and (3) cleaner energy source than gasoline. Due to the physical characteristics of natural gas, the volumetric efficiency and flame speed of a natural gas engine are lower than those of a gasoline engine, which results in a power loss of 10-20% when compared to a convensional gasoline engine. This paper describes the results of a research to improve the performance of a natural gas engine through the modification and controls of air/fuel ratio, spark timing advance and supercharging effect by forced air supply method.

Interior noise prediction of the Korean high speed train using sound source contribution analysis and sensitivity analysis of wall′s transmission loss (소음원 기여도 해석 및 벽면 투과손실에 대한 민감도 해석에 의한 한국형 고속철도의 실내소음 예측)

  • 김관주;박진규
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1093-1098
    • /
    • 2001
  • The interior sound pressure level of the Korean high speed train is predicted using ray acoustic method. The motor car, motorized car and passenger cabin are investigated under the environment of passing open countryside and inside tunnel Calculated sound levels of KHST are compared with the those of KTX prototype which vehicle shows similar acoustic behavior with KHST for the purpose of assuring the calculated data. In order to reduce the calculated SPL in systematic way, contribution analysis of sound sources and sensitivity analysis of concerning wall's transmission loss on the SPL of the designated receiving points are carried out. Finally, practical design suggestions are proposed.

  • PDF

A Review on the Emission Sources of Ammonia and the Factors Affecting Its Loss

  • Das, Piw;Sa, Jae-Hwan;Kim, D.S.;Kim, K.H.;Jeon, E.C.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.E2
    • /
    • pp.47-56
    • /
    • 2007
  • Among all the nitrogen species present in the atmosphere, ammonia forms a considerable portion along with the nitrogen oxides. The major sources of atmospheric ammonia are animal feedlot operations including emission from excreta of domestic animals and agricultural activities, followed by emission from synthetic fertilizers, biomass burning and to some lesser extent, fossil fuel combustion. Ammonia emission factor, expressed as the weight of ammonia per unit weight, volume, or duration of the activity emitting it, is generally used in developing emission estimates for emission inventories. The factors determining ammonia loss from soil or from manures are the temperature, pH, humidity, precipitation and the velocity of wind above it.

A Study on the Performance Enhancements of Video Streaming Service in MPLS Network

  • Kwak Kyoung Hwan;Park In Kap;Kim Chung Hyun
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.549-551
    • /
    • 2004
  • This paper used OPNET to simulate video streaming service a test IP network and MPLS network with the traffic shaping that have with CQ_ LLQ algorithm, LSP of fixed bandwidth, policy of limitation users and measures parameters such as delay, throughput, packet loss. To verify the performance of video streaming service in IP network and MPLS network, two scenario that have same topology and traffic source. One is the simulation for best-effort service in pure IP network. The other is the simulation for QoS-enabled service in MPLS Network. Based on simulation result, the MPLS network with CQ_ LLQ algorithm and fixed LSP show advantage of the video streaming service QoS, specially delay and packet loss

  • PDF