• Title/Summary/Keyword: Source To Image Receptor Distance

Search Result 14, Processing Time 0.033 seconds

Evaluation of Relationship between Radiation Dose and Image Quality according to Source to Image Receptor Distance in Rib Series Radiography (늑골 방사선검사 시 X선관 초점-영상수신체간 거리에 따른 환자선량과 화질의 연관성 평가)

  • Joo, Young-Cheol;Jung, Young-Jin
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.391-396
    • /
    • 2018
  • The purpose of this study was to compare and analyze the patient dose according to the distance between the X-ray tube focus and the image receptor, and to propose a new method for quantitatively evaluating the image quality. Using this quantitative evaluation method, the optimal distance for increasing x-ray image quality with low radiation dose was estimated between source and image receptor in Rib series radiography. Phantom images were obtained by changing the distance between focus and image receptor (100 cm and 180 cm). The patient radiation dose was estimated using entrance surface dose and dose area product. In order to evaluate image quality objectively, a non - reference image evaluation method was employed with paper and salt noise and Gaussian filter. As a result of this study, when the SID was changed from 100 cm to 180 cm, the entrance surface dose decreased by 4 ~ 5 times and the dose area product decreased by 3 times. In addition, there is no significant difference in image quality between of SID 180 cm and SID 100 cm. In conclusion, it was demonstrated that performing the rib series radiography at SID 180 cm is an optimal method to reduce the exposure dose and improve the image quality.

A Study on Patients Dose and Image Quality according to Source to Image receptor Distance in Abdomen Radiography: comparison of ESD measured and DRLs in other countries (복부일반촬영시 선원과 검출기간의 거리변화에 따른 영상 화질 및 피폭선량에 관한 연구)

  • Jang, Ji-Sung;Choi, Weon-Keun;Jung, Jae-Yon;Lee, Kwan-Sub;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.39-46
    • /
    • 2012
  • Purpose : The purpose of this study was to reduce Entrance Surface Dose and maintain image quality by changing Source to Image receptor Distance. And we'd like to compare ESD on this study to DRLs in other contries. Materials and Methods : We used indirect DR system(Definium 8000, General Electric, USA)and phantom(ART-200X, Flukebiomedical, USA),glass dosimeters(GD-352M, Asahi Techno Glass, Japan)for this study. The imagies were obtained throuh 80kVp fixed, and different tube currents using AEC mode in $16{\times}16$(inch) field size and changing Source to Image receptor Distance from 100 cm to 130 cm per 10 cm unit. The phantom with attaching 5 glass dosimeters on abdomonal skin was set at supine and erect position as a anterioposterial projection on detector For measuring Entrance Surface Dose. Image analysis was conducted by histograms of Image J(1.46r) which was given from National Institutes of Health(NIH). Results : Due to inverse square law of distance, the tube currents were increasing 42.6 % in supine position and 32.6 % in erect position according to the change of Source to Image receptor Distance. While Entrance Surface Doses were rapidly decreasing 14.2 % in supine position and 29.4 % in erect position according to the change of Source to Image receptor Distance. As the results of histogram using Image J, pixel mean values from 100 cm to 110 cm, 120 cm and 130 cm were decreasing each 1.4%, 2.5%, 2.7%, 4.5%, 2.2 %, 5.8 % in supine, erect position. While standard deviations from 100 cm to 110 cm, 120 cm and 130 cm were increasing each 1.4 %, 2.5 %, 2.5 %, 4.0 %, 2.0 %, 4.9 % Consequently, there are no significant differences in abdomen images taken. Conclusion: As the results described above, we strongly recommend using long Sourceto Image receptor Distance than 100cm that we have been using. So, we should deliver less Entrance Surface Dose to the patients while maintaining image quality in abdomen radiography.

  • PDF

Assessment of Dose and Image Quality according to the Change of Distance from Source to Image Receptor and the Examination Posture during the Skull Lateral Radiography (두부 측 방향 방사선검사 시 선원 영상수용체간 거리와 검사 자세 변화가 선량과 영상품질에 미치는 영향)

  • Eun-Hye, Kim;Young-Cheol, Joo;Han-Yong, Kim;Dong-Hwan, Kim
    • Journal of radiological science and technology
    • /
    • v.45 no.6
    • /
    • pp.483-489
    • /
    • 2022
  • This study proposes a new skull lateral examination, and provides an improved examination environment for patients and radiologists. The study was divided into three groups. One group was divided into the SID (source to image receptor distance) 110 ㎝ and 180 ㎝ in the skull lateral posture, the other group The other group was divided into an position in contact with the detector and an position without contact with the detector, and the other group was divided into male and female groups, considering that the difference in shoulder width between adult males and females would affect the dose and image quality. For dose evaluation, the ESD (entrance surface dose) was measured at the EAM (external auditory meatus), and the conditions were applied equally at 70 ㎸p, 200 ㎃, and 10 ㎃s. For image quality evaluation, SNR (signal to noise ratio) and CNR (contrast to noise ratio) were measured in frontal sinus, EAM, and sella turcica. As a result of ESD comparison, when sid 110 ㎝ to sid 180 ㎝ was changed among the three groups, ESD values decreased the most to 729.18±4.62 μ㏉ and 224.18±0.74 μ㏉ at 180 ㎝ (p<0.01). The values of SNR and CNR were statistically significant (p<0.01), but there was no qualitative difference. This shows that when the SID is 180 ㎝, it is possible to reduce the dose without lowering the image quality. So, It is suggested that the SID 180 ㎝ is used without contacting the detector when examining the skull lateral.

The Effect of Source to Image-Receptor Distance(SID) on Radiation Dose for Digital Chest Radiography (Digital Chest Radiography에서 방사선량에 대한 Source to Image-Receptor Distance (SID)의 영향)

  • Kwon, Soonmu;Park, Changhee;Park, Jeongkyu;Son, Woonheung;Jung, Jaeeun
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.203-210
    • /
    • 2014
  • Chest radiography has been typically performed at SID of 180 cm. Image quality and patient dose were investigated between 180 cm and 340 cm by 20 cm intervals at 120 kVp and 320 mAs with the AEC. VGA was performed for qualitative assessment and SNR was analysed for quantitative assessment on the image of the chest phantom. Patients dose was measured by ESAK and PCXMC was used for effective dose. As a result, when using the standard of SID of 180 cm which is typically used in the clinical practice, in the case of ESAK, 240 cm, 280 cm, and 320 cm were 8.7%, 11.47%, and 13.56% respectively therefore significant reduction was confirmed. In the case of effective dose, 2.89%, 4.67%, and 6.41% in the body and 5.08%, 6.09%, and 9.6% in lung were reduced. In the case of SNR, 9.04%, 8.24%, and 11.46% were respectively decreased especially, by 8.03% between SID of 260 cm and 300 cm, but SNR was 5.24 up to 340 cm. There were no significant differences in VGA thus the image is valuable in diagnosis. It is predicted that increasing SID up to 300 cm in digital chest radiography can reduce patient dose without decreasing image quality.

Study on Exposure Dose According to Change of Source to Image Distance and Additional Filter Using Abdomen Phantom (복부팬텀을 이용한 SID 변화와 부가필터 유무에 따른 피폭선량에 관한 연구)

  • Kim, Ki-Won;Son, Jin-Hyun
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.407-414
    • /
    • 2016
  • This study is to minimize the patient dose and maintain the image quality according to change of source to image receptor distance and applying additional filter. In this study, we used the DR system, the tissue-equivalent abdomen phantom and the aluminium filter. The exposure conditions were set to 80 kVp using AEC mode. The collimation size was $16{\times}16inch$. The exposure dose were measured 10 times when the SID was changed with 100, 110, 120 and 130 cm, respectively. The pirana 657 for dosimeter was located on center of radiation irradiation. The acquired images were analyzed by using the image J. In the results, the tube current was increased with increasing the SID but ESD was decreased with increasing the SID. The decrease of ESD attribute to use of filter that remove the photon of lower energy. In the histogram results using image J, there were differences between the ESD and the exposure conditions according to change of SID. However, there were not differences in histogram. Therefore, the exposure dose could reduced when set the longer SID. For pediatric exam, the exposure dose could reduced when used the aluminium filter.

Buildup Characteristics of Radiophotoluminescent Glass Dosimeters with Exposure Time of X-ray (엑스선의 조사시간에 따른 형광유리선량계의 빌드업 특성)

  • Kweon, Dae Cheol
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.256-263
    • /
    • 2017
  • By using the buildup characteristics of the radiophotoluminescence glass dosimeter(RPLGD), it is aimed to help the measurement of the accurate dose by measuring the radiation dose according to the time of the glass element. Five glass elements were arranged on the table and the source to image receptor distance(SID) was set to 100 cm for the build-up radiation dose measurement of the fluorescent glass dosimeter glass element(GD-352M). Radiation doses and saturation rates were measured over time according to irradiation time, with the tube voltage (30, 60, 90 kVp) and tube current (50, 100 mAs) Repeatability test was repeated ten times to measure the coefficient of variation. The radiation dose increased from 0.182 mGy to 12.902 mGy and the saturation rate increased from 58.3% with increasing exposure condition and time. The coefficient of variation of the glass elements of the fluorescent glass dosimeter was ranged from 0.2 to 0.77 according to the X - ray exposure conditions. X - ray exposure showed that the radiation dose and saturation rate were increased with buildup characteristics, and degeneration of glass elements was not observed. The reproducibility of the variation coefficient of the radiation generator was included within the error range and the reproducibility of the radiation dose was excellent.

Radiographic Study of Cobey Method and Modified Cobey Method (Cobey 검사법과 Modified Cobey 검사법에 대한 방사선학적 연구)

  • Go, Yu-Rim;Joo, Young-Cheol;Lee, Seung-Keun
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.167-173
    • /
    • 2019
  • The Cobey method and the modified Cobey method are most commonly used in clinical practice. Therefore, the purpose of this study was to investigate the radiological differences between Cobey and modified Cobey and provide radiographic information about changes of hindfoot image with X-ray entrance center and tube angle change in modified Cobey. This study was performed on foot and ankle phantom. First, for image comparison of Cobey and modified Cobey, the images obtained by applying the same X-ray entrance center to the ankle joint were compared and analyzed. Second, in the modified Cobey, the X-ray entrance center is set as ankle joint and lateral malleolus. The X-ray tube angle was varied from $10^{\circ}$ to $40^{\circ}$ at $5^{\circ}$ intervals for each X-ray entrance center. The images obtained by varying the X-ray tube angle from $10^{\circ}$ to $40^{\circ}$ at intervals of $5^{\circ}$ for each X-ray entrance center were compared and analyzed. The irradiation conditions were the same with 110 kVp, 200 mA, 10 ms, and 110 cm of source - image receptor distance (SID). Image evaluation was performed by two radiologists. Measurements were made on the lateral point, middle point, and calcaneus width based on a hypothetical line parallel to the calcaneal tuberosity. Data were analyzed by using descriptive statistics as the mean of the distance to each measurement location. The modified Cobey was longer than the Cobey by an average of 3 to 4 mm lateral and medial points, and the calcaneus width was similar (ICC = 0.939). In modified Cobey method, when the X-ray entrance center is ankle joint, the lateral point is about 3 mm and the medial point is about 4.3 mm longer than lateral malleolus. Also, when the X-ray tube angle is more than $20^{\circ}$, the degree of distortion is large. The ICCs for the lateral, medial point, and calcaneus width were 0.998, 0.961, and 0.997, respectively, as the X-ray entrance center and tube angle were changed. There was no significant difference between Modified Cobey and Cobey. Modified Cobey showed no need to compensate the $20^{\circ}$ detector angle of the Cobey. In addition, we suggest that tube angle should be limited within $20^{\circ}$ when modified Cobey is performed.

Effect of High Tube Voltage and Scatter Ray Post-processing Software on Image Quality and Radiation Dose During Chest Anteroposterior Radiography (흉부 전·후방향 검사 시 고관전압 및 산란선 후처리 소프트웨어 적용이 화질과 선량에 미치는 영향)

  • Kim, Jong-Seok;Joo, Young-Cheol;Lee, Seung-Keun
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.295-300
    • /
    • 2021
  • This study aims to present new chest AP examination exposure conditions through a study on the effect on image quality and patient dose by applying high tube voltage and scatter ray post-processing software during chest AP examination in digital radiography equipment. This study was used a human body phantom and in the chest AP position, the dosimeter was placed horizontally at the thoracic spine 6. The experiment was conducted by dividing into a low tube voltage (70 kVp, 400 mA, 3.2 mAs) group and a high tube voltage (100 kVp, 400 mA, 1.2 mAs) group. The collimation size (14″× 17″) and the source to image receptor distance(110 cm) were same applied to both groups. Radiation dose was presented to dose area product and entrance surface dose. Image quality was compared and analyzed by comparing the difference between the signal-to-noise ratio and the contrast-to-noise ratio of the image according to the application of the scatter ray post-processing software under each condition. The average value of the entrance surface dose in the low and high tube voltage conditions was 93.04±0.45 µGy and 94.25±1.51 µGy, which was slightly higher in the high tube voltage condition, but the dose area product was 0.97±0.04 µGy and 0.93±0.01 µGy. There was a statistically significant difference in the group mean value(p<0.01). In terms of image quality, the values of the signal-to-noise ratio and the contrast noise ratio were higher in the high tube voltage than in the low tube voltage, and decreased when the scattering line post-processing function was used, but the contrast resolution was improved. If there is a scatter ray post-processing function during chest AP examination, it is helpful to actively utilize it to improve the image quality. However, when this function is not available, I thought that applying a higher tube voltage state than a low tube voltage state will help to realize images with a large amount of information without changing the dose.

A Study on Chest X-ray Using Ancillary Device for Child Radiography (방사선촬영 보조기구를 이용한 어린이 흉부 엑스선 검사에 관한 연구)

  • Rhee, Do-byung;Lee, Somi;Choi, Hyunwoo;Kim, Jong-ki;Lee, Jongmin
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.1
    • /
    • pp.48-54
    • /
    • 2018
  • In this study, We developed a Ancillary device for child radiography for X-ray of children under 5 years old and verified its effectiveness. Chest X-rays of children younger than 5 years of age were performed by Supine method at the position of Table detector, Short - Source to Image Receptor Distance(SID). Existing Supine and Short -SID imaging methods cause many problems, such as errors in image reading and excessive radiation exposure dose to patients, but the use of an Ancillary device for child radiography(ADCR) solves these problems. A total of 160 children were divided into the Upright group using ADCR and Supine group without ADCR. The chest X-ray image was visually evaluated by two radiologists with reference to the European Commission's List of Quality Criteria for Diagnostic Radiographic Images in Pediatrics. The total score of the qualitative evaluation was 5.15% higher in the chest upright method using ADCR than in the chest supine method without ADCR, and the chest upright method score was higher than that of the chest supine method in items 1 to 7. whether infants have deep inspiration or not, 4.87% higher for item 1, whether infants rotate or not and the degree of tilting, 0% higher for the item 2, the reproduction of image from just above apices of lungs to T12/L1, 0% for the item 3, reproduction of the vascular pattern in central 2/3 of the lungs, 6.92% higher for the item 4, reproduction of the trachea and the proximal bronchi, 12.9% higher for the item 5, visually sharp reproduction of the diaphragm and costo-phrenic angles, 10% higher for the item 6, reproduction of the spine and paraspinal structures and visualisation of the retrocardiac lung and the mediastinum, and 3.65% higher for the item 7. Items 2 and 3 showed no statistically significant differences(P > 0.05), and items 1, 4, 5, 6, and 7 showed statistically significant differences(P < 0.05). In conclusion, Upright method using ADCR in pediatric chest X-ray is considered as a good alternative to existing Supine method.