• Title/Summary/Keyword: Source Site

Search Result 1,111, Processing Time 0.04 seconds

The Source Parameters of Offshore Earthquakes with Magnitude Larger than 4.0 Nearby Sinan (신안 앞바다 인근 규모 4.0 이상 지진들의 지진원 상수)

  • Choi, Hoseon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.213-219
    • /
    • 2014
  • The source parameters of four earthquakes with magnitude larger than 4.0 nearby the offshore Sinan are analyzed. The waveform inversion method is used for analyzing the source parameters of two events (20 August 2012 and 21 April 2013) with C&B and AK135-c crustal velocity structure models. The source parameters of the other two events (26 July 1994 and 23 March 2003) are obtained from references. Focal mechanisms of the events are strike slip faulting or strike slip faulting with a thrust component. The directions of P-axes of the events are ENE-WSW or NE-SW which are similar to previous studies on P-axes in and around the Korean peninsula. With regard to the events nearby the offshore Sinan, the regional stress, rather than being local stress, is seen to be the result of the combination of tectonic forces from the compression of plates colliding to the Eurasian Plate.

Site-specific Disruption of Glyoxylate Bypass and Its Effect in Lysine-producing Corynebacterium lactofermentum Strain

  • Kim, Youn-Hee;Lee, Heung-Shick
    • Journal of Microbiology and Biotechnology
    • /
    • v.6 no.5
    • /
    • pp.315-320
    • /
    • 1996
  • The role of glyoxylate bypass in a lysine-producing Corynebacterium lactofermentum strain was analyzed. Unlike the wild type, the strain expressed enzymes of glyoxylate bypass during growth in the fermentation broth containing glucose as the carbon source. To evaluate the importance of glyoxylate bypass in the strain, we disrupted chromosomal aceA by using a cloned fragment of the gene. Site-specific disruption of aceA which codes for the isocitrate lyase, the first enzyme of the bypass, was confirmed by Southern blot analysis. The aceA mutant strain completely lost isocitrate lyase activity and ability to grow in a minimal medium containing acetate as the sole carbon source. The mutant strain was similar to its parental strain in growth characteristics and produced comparable amounts of lysine in shake flasks containing glucose as the carbon source. The amount of oxaloacetate accumulated in the fermentation medium was similar for both strains, suggesting that expression of glyoxylate bypass does not necessarily lead to the increase in intracellular oxaloacetate. These data clearly demonstrate that glyoxylate bypass does not function as one of the routes of carbon supply for lysine production in the strain. It appears that the leakiness of the glyoxylate bypass in the strain might be the result of a secondary mutation which arose during previous strain development by random mutagenesis.

  • PDF

Life cycle cost analysis and smart operation mode of ground source heat pump system

  • Yoon, Seok;Lee, Seung-Rae
    • Smart Structures and Systems
    • /
    • v.16 no.4
    • /
    • pp.743-758
    • /
    • 2015
  • This paper presents an advanced life cycle cost (LCC) analysis of a ground source heat pump (GSHP) system and suggests a smart operation mode with a thermal performance test (TPT) and an energy pile system constructed on the site of the Incheon International Airport (IIA). First, an economic analysis of the GSHP system was conducted for the second passenger terminal of the IIA considering actual influencing factors such as government support and the residual value of the equipment. The analysis results showed that the economic efficiency of the GSHP system could be increased owing to several influential factors. Second, a multiple regression analysis was conducted using different independent variables in order to analyze the influence indices with regard to the LCC results. Every independent index, in this case the initial construction cost, lifespan of the equipment, discount rate and the amount of price inflation can affect the LCC results. Third, a GSHP system using an energy pile was installed on the site of the construction laboratory institute of the IIA. TPTs of W-shape and spiral-coil-type GHEs were conducted in continuous and intermittent operation modes, respectively, prior to system operation of the energy pile. A cooling GSHP system in the energy pile was operated in both the continuous and intermittent modes, and the LCC was calculated. Furthermore, the smart operation mode and LCC were analyzed considering the application of a thermal storage tank.

Regional Distribution Characteristics of Total Gaseous Mercury in Air-Measurements from Urban and Mountainous Sites in Korea (대기 중 수은의 지역적 분포특성에 대한 비교연구-한반도의 도심과 산악지역을 중심으로)

  • 김민영;김기현
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.1
    • /
    • pp.39-50
    • /
    • 2001
  • The spatial distribution characteristics of airborbe mercury(Hg) were investigated used its concentration data from six measurement sites selected to represent:(1) three terminal sites with heavy traffic loads in urban area, (2) one urban residential site and (3) two mountainous sites in Korea. The measurement data obtained during September 1997 through May 1998 indicated that the mean concentration of Hg from different study sites were comparably high with the mean values spanning from 5-9ng./㎥. The concentration from all those sites were systmatically high compared to those of most background sites around world or to other Korean sites investigaed previously. When results of correlation analysis between Hg and relevant parameters were compared among different study sites. temperature was most frequently found out to be in strong correlation with Hg concentrations. Results of factor analysis also indicated that Hg concentrations could be affected simultaneously by th factors affecting such parameters as ozone, temperature, ozone, carbon monoxide, and PM. The findings of enhanced Hg levels from Ji-Ri Mountain relative to terminal site suggest that is distributions may be rather homogeneous not enough to clearly distinguish areal differences and the associated source signatures between urban and rural area. The existence of systmatically high concentrations from all investigated sites also indicate that the impact of its source processes should be quite ubiquitous, while highly variable in relatively long term scale.

  • PDF

Non-Point Source Pollutions of the Youngsan River Basins I - The Method of Land-Use Types and Rainfall - (영산강 수계의 비점오염원에 관한 연구 I - 토지이용 및 강우를 중심으로 -)

  • Cha, Jin Myeong;Shin, Sung Euy;Cha, Gyu Suk
    • Journal of Environmental Impact Assessment
    • /
    • v.8 no.1
    • /
    • pp.41-49
    • /
    • 1999
  • This study was carried out to estimate the runoff loading characteristics of the non-point source pollutions in the Youngsan river basins by the method of land-use types and rainfall. The lysimeter test, rainfall and stream flowmeter measurement were performed to develop the pollutant loading unit discharged from the non-point sources. As the non-point sources, the unit pollutant discharge rates were different from the land-use types such as paddy field, upland, forest, housing site and others. The pollutant loading units classified by land-use types in the Youngsan river basins are as follows: The total BOD loading rate is 15.3 ton/day and the housing site is discharged 50.6%, the total T-N loading rate is 6.0 ton/day and the paddy field and upland is discharged 77.6%, and the total T-P loading rate is 0.39 ton/day and the paddy field and upland is discharged 81.2%. The pollutant loadings by rainfall in the Youngsan river basins are about 7,425 ton/year of BOD, 324 ton/year of T-N and 118 ton/year of T-P, respectively.

  • PDF

Assessment of Dynamic Open-source Cross-site Scripting Filters for Web Application

  • Talib, Nurul Atiqah Abu;Doh, Kyung-Goo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.10
    • /
    • pp.3750-3770
    • /
    • 2021
  • This study investigates open-source dynamic XSS filters used as security devices in web applications to account for the effectiveness of filters in protecting against XSS attacks. The experiment involves twelve representative filters, which are examined individually by placing them into the final output function of a custom-built single-input-form web application. To assess the effectiveness of the filters in their tasks of sanitizing XSS payloads and in preserving benign payloads, a black-box testing method is applied using an automated XSS testing framework. The result in working with malicious and benign payloads shows an important trade-off in the filters' tasks. Because the filters that only check for dangerous or safe elements, they seem to neglect to validate their values. As some safe values are mistreated as dangerous elements, their benign payload function is lost in the way. For the filters to be more effective, it is suggested that they should be able to validate the respective values of malicious and benign payloads; thus, minimizing the trade-off. This particular assessment of XSS filters provides important insight regarding the filters that can be used to mitigate threats, including the possible configurations to improve them in handling both malicious and benign payloads.

Analysis on the Effect of Local Climate on the Unit-type Ground Heat Exchanger (지역 기후가 유닛형 지중열교환기 성능에 미치는 영향)

  • Bae, Sangmu;Kim, Jae-Min;Nam, Yujin
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.1
    • /
    • pp.67-76
    • /
    • 2019
  • A ground source heat pump (GSHP) system can stable system operation by using underground heat source and has high reliability for energy production. However, wide-spread of the GSHP system is delayed to high initial investment costs. In previous studies, horizontal and unit-type ground heat exchanger (GHX) have developed to overcome disadvantages such as high initial cost. However, these performances of GHXs are greatly influenced by climate and weather conditions. It is necessary to analyze the performance of GHX according to the ground temperature change in the installation site. In this study, the ground temperature of each installation site confirmed and performance of unit-type GHX quantitatively analyzed by numerical analysis. As the result, the performance of the unit type GHX was 33.9 W/m in Seoul, 34.2 W/m in Daejeon, and 37.2 W/m in Busan.The result showed the difference performance of GHX according to local climate was maximum of 9.7%.

A Study on the SCW Ground Source Heat Pump System Technologies for Residential Cluster Homes (수주지열정 지열원 열펌프 시스템의 집단주거시설 적용을 위한 기반 기술 분석)

  • Lee, Kwang Ho;Do, Sung Lok;Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.3
    • /
    • pp.14-20
    • /
    • 2019
  • In this study, the technologies and regulations for distributing standing column well(SCW) ground source heat pump systems to the residential cluster homes were investigated. They have only been installed in the public or commercial building having different load pattern and site structure compared with the residential cluster homes. Some of SCWs for the residential cluster homes should be installed under the basement due to a lack of site area. There are pressure differences between the SCWs installed under ground surface and basement. It is needed to develop the technology or devices to prevent overflow caused by pressure difference among the SCWs. In addition, heat balance algorithm between SCWs should be adopted to maximize the system efficiency. A heat pump having heating, cooling, hot water, heating-hot water, and cooling-hot water modes should be developed for adopting an individual air-conditioning system to the residential cluster homes.

A Comparison Study of the Amplification Characteristics of the Seismic Station near Yedang Reservoir using Background Noise, S-wave and Coda wave Energy (배경잡음, S파 및 Coda파 에너지를 이용한 예당저수지 인근부지의 지반증폭 특성에 관한 비교 연구)

  • Wee, Soung-Hoon;Kim, Jun-Kyoung;Yoo, Seong-Hwa;Kyung, Jai-Bok
    • Journal of the Korean earth science society
    • /
    • v.36 no.7
    • /
    • pp.632-642
    • /
    • 2015
  • Seismograms are composed of 3 characteristics, that is, seismic source, attenuation, and site amplification. Among them, site amplification characteristics should be considered significantly to estimate seismic source and attenuation characteristics with more confidence. This purpose of this study is to estimate the site amplification characteristics at each site using horizontal to vertical (H/V) spectral ratio method. This method, originally proposed by Nakamura (1989), has been applied to study the surface waves in microtremor records. It has been recently extended to the shear wave energy of strong motion and applied to the study of site amplification. This study analyzed the H/V spectral ratio of 6 ground motions respectively using observed data from 4 sites nearby in Yedang Reservoir. And then, site amplification effects at each site, from 3 kinds of seismic energies, that is, S waves, Coda waves energy, and background noise were compared each other. The results suggested that 4 sites showed its own characteristics of site amplification property in specific resonance frequency ranges (YDS: ~11 Hz, YDU: ~4 Hz, YDD: ~7 Hz). Comparison of this study to other studies using different analysis method can give us much more information about dynamic amplification of domestic sites characteristics and site classification.

Development of Heating Technology for Greenhouse by Use of Ground Filtration Water Source Heat Pump (여과수열원 히트펌프를 이용한 온실난방기술 개발)

  • Moon, J.P.;Lee, S.H.;Kang, Y.K.;Lee, S.J.;Kim, K.W.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.172.2-172.2
    • /
    • 2010
  • This study was carried out in order to reduce the installation expense of heating system for greenhouse comparing to geothermal heat pump and develope the coefficient of performance (COP) for a heat pump. For getting plenty of heat flux from geothermal energy. Surface water in river channel was used for getting a lots of geothermal heat by penetrating water through underground soil layer of the river bank that make heat transmission to passing water. The range of water temperature after the process of Ground filtration is 13~18 degrees celsius which is very similar to low heat source of geothermal heat pump system and the plenty amount of heat source from that make the number of geothermal heat exchanging hole and the expense for geothermal heat exchanger construction reduced. Drainage well is also used for returning filtration water to the aquifer that keep the water good recirculation from losing geothermal heat and water resource. For the COP improvement of Heat pump, thermal storage tank with separating insulation plate according to the temperature difference make the COP of Heat pump that is similar to thermal storage tank with diffuser. Developed thermal storage tank make construction expense cheaper than customarily used one's. and that sand filter and oxidation sand (FELOX) are going to be used for improving ground filtration water quality that make heat exchanger efficiency better. All above developed component skill are going to be set on the Ground filtration water source heat pump system and applied for medium, large scale for protected greenhouse in riverside area and on-site experiment is going to do for optimizing the heating system function and overcome the problem happening in the process of on-site application afterward.

  • PDF