• 제목/요약/키워드: Source Characteristics

검색결과 6,541건 처리시간 0.03초

CHARACTERISTICS OF SMOKE CONCENTRATION PROFILES WITH UNDERGROUND UTILITY TUNNEL FIRE

  • Kim Hong Sik;Hwang In Ju;Kim Youn-Jea
    • 한국전산유체공학회지
    • /
    • 제10권1호
    • /
    • pp.94-98
    • /
    • 2005
  • Accurate prediction of the fire-induced air velocity, temperature and smoke flow in underground utility tunnel becomes more important for the optimization of design and placement of heat and smoke detectors. In order to improve the safety of underground utility tunnel systems, the behaviors of fire-induced smoke flow and temperature distributions are investigated. Especially, two different cross-sectional shapes of tunnel, such as rectangular and circular types are modeled. Also, fire source is modeled as a volumetric heat source. Three-dimensional thermal-flow characteristics in an underground tunnel are solved by means of FVM using SIMPLE algorithm. The effects of shape geometry on the fire-induced flow characteristics are graphically depicted. It is desirable that heat and smoke detectors are installed on the cables and the top of the wall.

음향 인텐시티법을 이용한 주행열차의 음향방사특성의 검토 (Study on the Sound Radiaton Characteristics of Trains by Sound Intensity Method)

  • 주진수;김재철
    • 소음진동
    • /
    • 제8권4호
    • /
    • pp.603-608
    • /
    • 1998
  • In order to obtain basic data for the prediction of railway noise propagation, the noise radiation characteristics (source position, radiation directivity, etc) of trains were measured by using the sound intensity method. The measurements were performed at a side of railway by setting an intensity-probe array. As the measurement results, it was found that rolling noise due to interaction between wheel and rail and motor noise radiation from the lower part of train are dominant. The location of main sound sources can be described as being at the height of 0.1m in the center line of track, and the radiation directivity in the cross section of actually running trains are presented as a dipole source.

  • PDF

축전지 전원을 사용한 소형선박 추진용 BLDC모터의 전력변환방식에 따른 효율 비교 및 성능 추정 (Efficiency Comparison according to Power Conversion Method and Performance Estimation for Battery Source BLDC Motor Propulsion System of Small Ships)

  • 정태영;정석권
    • 동력기계공학회지
    • /
    • 제14권1호
    • /
    • pp.27-33
    • /
    • 2010
  • We investigate some operation characteristics and energy efficiency of the BLDC motor system driven by different two types power conversion method depends on same battery source for applying to electrical motor propulsion system of a small ship. Also, we suggest an estimation manner of operating performances such as total running distance and operating speed of ships from basic discharge voltage characteristics of batteries. Through some experiments, direct power conversion was better than indirect method on the view point of energy efficiency and the voltage discharge characteristics could be used as important design factor for estimating operating performances of small ships driven by electrical motors.

도시, 농촌 및 임야유역으로부터 배출되는 비점원 오염부하의 특성비교 (Comparison of Discharge Characteristics of NPS Pollutant Loads from Urban, Agricultural and Forestry Watersheds)

  • 여중현;김건하
    • 한국물환경학회지
    • /
    • 제21권2호
    • /
    • pp.184-189
    • /
    • 2005
  • Impacts of non-point source pollution on water quality are well known. In this paper, effects of land use, precipitation characteristics, discharge characteristics on non-point source pollutant loadings at urban, agricultural and forestry watersheds were discussed. Rainfall runoffs from fifteen rainfall events were sampled and analysed at two urban watersheds, one rural watershed, and one forestry watershed. EMCs (Event Mean Concentration) were calculated based on monitored flow rates and concentrations. Statistical analysis carried out with runoff loadings and affecting variables indicated that runoff loadings are weakly correlated with the rainfall intensity and the dry days before rainfall events while showed no correlations with rainfall depth nor runoff quantity. By comparing EMCs between study watersheds on log-normal cumulative probability scale, EMCs ranking were in the descending order of urban watershed>agricultural watershed>forestry watershed for SS, TCOD, TN, and TP.

제한벽이 있는 공기제트에 의한 돌출 발열체의 냉각 특성에 대한 수치 해석 연구 (Numerical Study on the Cooling Characteristics of Pedestal Heat Source with an Confined Air Jet)

  • 최인수
    • 한국산업융합학회 논문집
    • /
    • 제12권1호
    • /
    • pp.11-18
    • /
    • 2009
  • The air flow and heat transfer characteristics of an air jet impinging on a pedestal heat source has been investigated numerically to examine the effects of geometric parameters such as nozzle-to-pedestal spacing, nozzle diameter and pedestal size. Also, the parameters of Reynolds number, air jet power, supplied heat and thermal conductivity of pedestal have been studied to reveal how these affect the average Nusselt number. Hence, a two-dimensional turbulent model has been developed and adopted to simulate the fluid flow and heat transfer phenomena numerically. The results obtained from the model show that the nozzle-to-pedestal spacing, relative size of nozzle to pedestal and Reynolds number of air jet have a significant influence on the cooling characteristics of heated pedestal. Furthermore, some useful guidelines could be given to the application of cooling the heated pedestal.

  • PDF

고주파 전원인가에 의한 무성방전 특성에 관한 연구 (The characteristics of Silent discharge using RF power source)

  • 이상근;이동욱;전병준;송현직;이광식;권혁한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.570-572
    • /
    • 2000
  • The characteristics of ozone generation were investigated in accordance with varying the diameter of internal electrode in an ozonizer using RF power source. The characteristics of ozone generation were improved with the diameter of internal electrode increased, but thermal loss was increased. Therefore, it was found that it is inevitable that the cooler has to be installed in an ozonizer which uses RF power source.

  • PDF

무효전력 제어에 의한 PCC전압 보상을 갖는 삼상 병렬형 능동전력필터 (A Three-Phase Parallel Active Power Filter Operating with PCC Voltage Compensation by Controlling Reactive Power)

  • 이우철;현동석;이택기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권3호
    • /
    • pp.211-218
    • /
    • 2000
  • The performance and dynamic characteristics of three-phase active power filter with PCC voltage compensation is presented and analyzed in this paper. The characteristics of parallel active filter are discussed when they are applied to nonlinear loads with current source and voltage source type, the characteristics of voltage compensator and comparison of two functions are discussed. The proposed scheme in this paper employs a PWM voltage-source inverter and has two operation modes. First, it operates as a conventional active filter with reactive power compensation while PCC voltage is in a certain range. Second, is operates as a voltage compensator while PCC voltage is out of range. Finally, the validity of this scheme is investigated through analysis of simulation and experimental results for a prototype active power filter system rated at 10KVA.

  • PDF

단효용 LiBr/물 흡수식 냉동사이클의 성능특성에 관한 연구 (A Study on Performance Characteristics of A Single Effect LiBr/Water Refrigeration Cycle)

  • 연제문;임삼택;오주원;이경우
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 춘계학술대회 논문집
    • /
    • pp.95-99
    • /
    • 2001
  • As a way to use energy effectively, the present study is aimed at investigating the performance characteristics of a Single Effect LiBr/Water Absorption Refrigerator using a low temperature driving heat-source. It was carried out by changing the driving heat-source temperature, the cold water outlet temperature(the refrigeration load), the cooling water inlet temperature, and the weak solution flow rate and this study compares the performance characteristics of refrigerator against the existence and non-existence of the Recirculation of the Weak solution which is used as a method to improve the performance of refrigerator. In case of Recirculation of the weak solution, more improved the Refrigeration Capacity and COP was obtained, and these effects became more larger in the high temperature of driving heat-source and large quantity of solution.

  • PDF

가스튜-브와 산화아연 바리스터의 PSpice 모델 (A PSpice Model of Gas Tube and ZnO Varistor)

  • 송재용
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권2호
    • /
    • pp.150-158
    • /
    • 1999
  • The process of designing protective circuits against damage by transient overvoltages requires much work and expensive equipment. However computer simulation using PSpice can overcome these problems. In this paper a gas tube and a ZnO varistor Pspice-model considering the steepness of the wave-front were presented. The effects of various waveforms on the transient behaviors and firing volt-ages of a gas tube were modeled by controlled voltage source E controlled current source G and TABLE function of PSpice. And the nonlinear characteristics of a ZnO varistor were modeled by controlled voltage source E and H. To estimate the characteristics of the models proposed various waveforms specified in IEC Std. 1000310-4-5 were used in the simulation and the actual tests. The simulation results were compared with test results and showed good agreement.

  • PDF