• Title/Summary/Keyword: Source Characteristics

Search Result 6,518, Processing Time 0.041 seconds

Characteristics of Pollutant Loads in Saemangeum Watershed Using HSPF (논문 - HSPF를 이용한 새만금 유역의 오염부하 특성)

  • Jung, Ji-Yeon;Shin, Yu-Ri;Choi, Jung-Hoon;Choi, In-Kyu;Yoon, Chun-Gyeong;Son, Yeong-Kwon
    • KCID journal
    • /
    • v.18 no.2
    • /
    • pp.54-65
    • /
    • 2011
  • This study was performed to analyze the influence of pollutant loads characteristics on the point and non-point sources in Saemangeum watershed area using Hydrological Simulation Program, Fortran (HSPF). The simulation items were flow, BOD, T-N, and T-P(2007~2010). The pollutant loads trend reflects the precipitation. Specifically, the point source loads were almost constant, but the non-point source loads were influenced in the precipitation. It was found that the effect of non-point source is larger than point source. The water quality had a clear trend by the season. However, pollutant loads did not show distinct seasonal changes. The reason is that the pollutant concentration is diluted by the increased flow at summer season. Therefore, it is important to control the non-point source in order to manage water quality in the region. For the management of Saemangeum lake, it is need to control of supplied pollutant loads from Saemangeum watershed.

  • PDF

A Study on Cooling Characteristics of Ground Source Heat Pump with Variation of Water Switching and Refrigerant Switching Methods (수절환 및 냉매절환방식에 따른 지열히트펌프의 냉방특성에 관한 연구)

  • Cha, Dong-An;Kwon, Oh-Kyung;Park, Cha-Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.8
    • /
    • pp.605-611
    • /
    • 2012
  • The objective of this study is to investigate the influence of the cooling performance for a water-to-water 10 RT ground source heat pump by using the water switching and refrigerant switching method. The test of water-to-water ground source heat pump was measured by varying the compressor speed, load side inlet temperature, and ground heat source side temperature. The cooling capacity and refrigerant mass flow rate of the heat pump increased with increasing ground heat source temperature. But COP of the heat pump decreased with increasing ground heat source temperature. As a result, the water switching method with counter flow, compared to a refrigerant switching method, improves the cooling capacity and COP by approximately 6~9% in average, respectively.

A Study on the Generating feature of Hydrogen Oxygen Gas Using Current Controlled Pulse Power Supply (전류제어형 펄스전원장치를 이용한 수산화 가스 발생 특성 연구)

  • Yang S. H.;Kang B. H.;Jun Y. S.;Mok H. S.;Choe G. H.
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.257-262
    • /
    • 2002
  • Water-Electrolyzed gas is a mixed gas has the constant volume ratio 2 1 Hydrogen and Oxygen gained from electrolyzed water, and it has better characteristics in the field of economy, efficiency of energy, and environmental intimacy than acetylene gas and LPG used for existing gas welding equipment. So nowdays many studies of Water-Electrolyzed gas are progressed, and commercially used as a source of thermal energy for gas welding in the industry. For Water-Electrolyzed Source, it was used diode rectifier or SCR rectifier for get DC source. This method which is not looking to improve a source for impossible current control or voltage and limited control intervals. In this paper, it was relized and designed In source of pulse type for complementing existing - DC source type, also by experiment it was acquired producting characteristics of Hydrogen -Oxygen Gas through feature of source

  • PDF

Characteristics Analysis of ZVS-HB Type High Frequency Resonant Inverter According to the Variable Capacitance of the DC Voltage Source Separation Capacitor (직류 전원 분할용 커패시터의 용량 변화에 따른 ZVS-HB형 고주파 공진 인버터의 특성해석)

  • Mun, Chang-Su;Kim, Jong-Hae;Kim, Dong-Hui;O, Seung-Hun;Sim, Gwang-Yeol;Min, Byeong-Jae
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.5
    • /
    • pp.352-357
    • /
    • 2000
  • This paper presents about an example of circuit design and characteristics of inverter according to the variable capacitance of the DC voltage source separation capacitor used in ZVS-HB type high frequency resonant inverter. The soft switching technology known as ZVS is used to reduce turn off loss at switching. In the event the capacitance of the DC voltage source separation capacitor is varied, the analysis of inverter circuit has generally described by using normalized parameter and operating characteristics have been evaluated in terms of switching frequency and parameters. According to the calculated characteristics value, a method of the circuit designs and operating characteristic of the inverter is also presented in this paper. In addition, this paper proves the validity of theoretical analysis through the experiment. This proposed inverter shows that it can be practically used in future as power source system for the lighting equipment of discharge lamp, DC-DC converter etc.

  • PDF

Variation of Illumination Performance with Source Size and Tolerance Characteristics of Freeform LED Lenses (LED 광원 크기에 따른 자유 형상 렌즈의 조명 성능 변화와 공차 특성)

  • Yang, Jae-Suk;Kim, Dae-Chan;O, Beom-Hoan;Park, Se-Geun;You, Il Hyun;Lee, Seung Gol
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.1
    • /
    • pp.29-38
    • /
    • 2013
  • In this paper, the illumination performances of three freeform lenses optimally designed for a point source were investigated for several LEDs with different source sizes, and also the tolerance characteristics of the lenses were analyzed. For comparison, two lenses with different sizes were designed with a divergent illumination model, and the last one was done with an overlapped illumination model. As the LED source size increased, the illuminance uniformity decreased more strongly, and the influence of a source misalignment on illumination performance became insignificant. However, the variation of LED radiation characteristics had strong effect on the illumination performance, irrespective of LED source size. Even though the lens based on a divergent illumination model showed superior performance compared to the lens based on an overlapped illumination model, the latter was less sensitive to the variation of LED radiation characteristics.

Effect of Information Source, Sales Promotion Type, and Impulse Buying Tendency Characteristics on Fashion Live Commerce Purchase Intention (정보원 특성, 판매촉진유형, 충동구매성향이 패션 라이브커머스 구매의도에 미치는 영향)

  • Choi, Hyun;Hwang, Sun Jin
    • Journal of Fashion Business
    • /
    • v.26 no.4
    • /
    • pp.52-63
    • /
    • 2022
  • As live commerce, mobile sales platforms based on real-time content and text are drawing attention as a new marketing channel. In particular, the fashion industry also using live commerce as a new fashion distribution channel, requiring marketing strategies to utilize it efficiently. This study attempted to verify the effect of information source, sales promotion, and impulse buying tendency characteristics on fashion live commerce purchase intention. The experimental design of this study was 2(characteristics of information source: expertise vs attractiveness) × 2(sales promotion type: value-added vs price discount) × 2(impulse buying tendency: high vs low) three-way mixed analysis of variance(ANOVA). A convenience sampling of 264 women in their 20s and 50s living in Seoul and the Gyeonggi area who had purchased products through Live Commerce was conducted. For the final analysis, 240 questionnaires were used. Data were analyzed by the SPSS 26 program and three-way ANOVA. Simple main effects analysis was conducted. The results of this study follow. First, there were statistically significant differences in purchase intention according to consumers' impulse buying tendencies and sales promotions. Second, information source and sales promotion showed statistically significant interaction effects on purchase intention. Lastly, information source, sales promotion, and impulse buying tendency showed significant three-way interaction effects on fashion live commerce purchase intention. Therefore, conducting appropriate marketing analysis can result in positive attitudes regarding live commerce products and substantive increases in sales.

An Analysis of the Acoustical Source Characteristics in the Time-varying Fluid Machines (유체기계 덕트 내 시변 음원의 음향 특성에 관한 연구)

  • 장승호;이준신;이정권
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.2
    • /
    • pp.104-112
    • /
    • 2003
  • The in-duct acoustical sources of fluid machines are often characterized by the source impedance and strength using the linear time-invariant model. However, negative resistances, which are physically unreasonable, have been found throughout various measurements of the source properties in IC-engines and compressors. In this paper, the effects of the time-varying nature of fluid machines on the source characteristics are studied analytically. For this purpose, the simple fluid machine consisting of a reciprocating piston and an exhaust is considered as representing a typical periodic, time-varying system and the equivalent circuits are analyzed. Simulated measurements using the analytic solutions show that the time-varying nature in the actual sources is one of the main causes of the negative source resistances. It is also found that, for the small magnitude of the time-varying component, the source radiates large acoustic power if the piston operates at twice the natural frequency of the static system. or integral submultiples of that rate.

Performance Characteristics of Flooded Type Evaporator for Seawater Cooling System with Heat Source Temperature of Mid-year (중간기 열원수 온도에 따른 만액식 해수냉각시스템의 성능 특성)

  • Yoon, Jung-In;Son, Chang-Hyo;Lee, Jeong-Mok;Kang, In-Ho
    • Journal of Power System Engineering
    • /
    • v.21 no.2
    • /
    • pp.64-69
    • /
    • 2017
  • The purpose of this study is to investigate the performance characteristics of seawater cooling system for a fishing vessel. The circulation amount of refrigerant, condensation capacity, evaporation capacity, compression work and coefficient of performance(COP) were analyzed as the heat source temperature changed. The experimental setup consisted of an open-type compressor, a shell&tube type condenser, an evaporator and an expansion valve. The heat source was controlled by a constant temperature chamber. The main results of this study are summarized as follows. The condensation capacity increased with increasing heat source temperature, and it was confirmed that the effect of circulating amount of refrigerant was dominant. The amount of heat for vaporization was almost constant even though the temperature of the heat source increased. On the other hand, the compression power was increased. This is because the compression ratio increases as the condensation pressure, the enthalpy difference between inlet and outlet, the amount of circulating refrigerant increases. The performance coefficient of this system showed a tendency decreasing with increasing heat source temperature. Therefore, the basic data of the seawater cooling system for the maintenance of the catch line of the shore fishing boats was acquired through this study, and it is considered that it will be sufficient for the actual design.

Characteristics of Runoff Load from Nonpoint Source Pollutants in the Lake Doam Watershed (도암호 유역에서 비점오염물질의 유출부하 특성)

  • Kwak, Sungjin;Bhattrai, Bal Dev;Gim, Giyoung;Kang, Phil-Goo;Heo, Woomyung
    • Korean Journal of Ecology and Environment
    • /
    • v.51 no.1
    • /
    • pp.135-147
    • /
    • 2018
  • In order to investigate the runoff characteristics of nonpoint source pollutants in the Lake Doam watershed, water quality and flow rate were monitored for 38-rainfall events from 2009 to 2016. The EMC values of SS, COD, TN and TP were in the range of 33~2,169, 3.5~56.9, 0.09~7.65 and $0.06{\sim}2.21mg\;L^{-1}$, respectively. As a result of analyzing the effect of rainfall factor on the nonpoint source pollutant load, EMCs of SS, COD and TP showed a statistically significant correlation with rainfall (RA) (p<0.01) and SS showed highly significant correlation with maximum rainfall intensity (MRI, R=0.48). The load ranges of SS, COD, TN and TP were 10.4~11,984.6, 1.1~724.4, 0.6~51.6 and $0.03{\sim}22.85ton\;event^{-1}$, respectively, showing large variation depending on the characteristics of rainfall events. The effect of rainfall on the load was analyzed. SS, COD and TP showed a positive correlation, but TN did not show any significant correlation. The annual load of SS was the highest with $88,645tons\;year^{-1}$ in 2011 when rainfall was the highest with 1,669 mm. The result of impact analysis of nonpoint source pollution reduction project and land-use change on runoff load showed that pollutant load significantly reduced from 2009 to 2014 but SS and TP loads were increased from 2014 to 2016 due to increase in construction area. Therefore, we suggested that nonpoint source pollution abatement plan should be continued to reduce the soil loss and pollutants during rainfall, and countermeasures to reduce nonpoint source pollution due to construction need to be established.

Evaporation Characteristics of Materials from an Electron Beam Evaporation Source (전자빔 증발원을 이용한 물질의 증발 특성)

  • Jeong, J.I.;Yang, J.H.;Park, H.S.;Jung, J.H.;Song, M.A.
    • Journal of the Korean institute of surface engineering
    • /
    • v.44 no.4
    • /
    • pp.155-164
    • /
    • 2011
  • Electron beam evaporation source is widely used to prepare thin films by physical vapor deposition because it is very effective to vaporize materials and there is virtually no limit to vaporize materials including metals and compounds such as oxide. In this study, evaporation characteristics of various metals and compounds from an electron beam evaporation source have been studied. The 180 degree deflection type electron beam evaporation source which has 6-hearth crucibles and is capable of inputting power up to 10 kW was employed for evaporation experiment. 36 materials including metals, oxides and fluorides have been tested and described in terms of optimum crucible liner, evaporation state, stability, and so on. Various crucible liners have been tried to find out the most effective way to vaporize materials. Two types of crucible liners have been employed in this experiment. One is contact type liner, and the other is non-contact type one. It has been tried to give the objective information and the most effective evaporation method on the evaporation of materials from the electron beam evaporation source. It is concluded that the electron beam evaporation source can be used to prepare good quality films by choosing the appropriate crucible liner.