• 제목/요약/키워드: Source

검색결과 35,877건 처리시간 0.056초

현대 패션 디자인의 그래픽 요소에 나타난 매개 소스별 미적 특성 -유희본능적 시각 표현을 중심으로- (Aesthetic Characteristics of Graphic Factor in Contemporary Fashion Design Categorized by Media Source -Focusing on Play-Instinct Visual Expression-)

  • 제갈미;이연희
    • 복식문화연구
    • /
    • 제19권5호
    • /
    • pp.945-956
    • /
    • 2011
  • The purpose for this paper is to categorize and analyze the aesthetic characteristics of graphic factors in contemporary fashion design by media source. Focused on play-instinct visual expression in contemporary fashion design and adopted media source following the way of communication design. A variety of literatures and online sites for graphic factors in contemporary fashion was studied. The standard of media source is classified as graphic media-source: photography media-source, typography media-source, illustration media-source. With this standard, expressed ways are as followings. First, graphic media-source in play-instinct expressional fashion design is mostly borrowing existed character or using designer's brand logo. Second, photography media-source in play-instinct expressional fashion design is placed photograph of social issued people in front of shirt. Third, typography media-source in play-instinct expressional contemporary fashion design is mostly expressed social messages or designer's name in brand. Fourth, illustration media-source is the best way to express play-instinct visual expression. Based on these, aesthetic characteristics of graphic factor in contemporary fashion by media source are classified as three: social words, playfulness and information transference. Frequency ratio using media source per aesthetic characteristics is different and these are able to categorize expression way and image feature. In conclusion, expressional way of graphic factors in contemporary fashion design became diverse as social and cultural changing. Frequency of graphic factor use in contemporary fashion is increased than before. This paper suggested that fashion design is one of the way of communicating with people and should be analyzed graphic factors in contemporary fashion design.

고 전력 Source Measurement Unit의 설계 및 제작 (Design and Implementation of High Power Source Measurement Unit)

  • 이상구;백왕기;박종식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.860-863
    • /
    • 2003
  • In this paper high power SMU(Source Measurement Unit) having 50V/1.5A source/measure range has been designed and implemented. The SMU has two operation mode, voltage mode and current mode. The SMU can be used as variable voltage source, variable current source, voltage meter, or current meter. Combining two different unit, output power can be doubled as 100V/1.5A. The developed SMU tan be used many semiconductor testing system and electronic device inspecting system.

  • PDF

흡입독성 연구에 이용될 0.25% 염화카드뮴 네뷸라이징 용액 에어로졸의 입경 (Particle Size of Aerosol from 0.25% Cadmium Chloride Nebulizing Solution for Inhalation Toxicology Study)

  • 정재열;이기남
    • 동의생리병리학회지
    • /
    • 제17권5호
    • /
    • pp.1257-1263
    • /
    • 2003
  • The modified engineering methodology and the modified electronic circuit in classical ultrasonic principles were applied to ultrasonic aerosol nebulizer for inhalation toxicology study of cadmium aerosol. 1532.96ppm Cd nebulizing solution was used to generate cadmium aerosol for particle size analysis with the modifying source and inlet temperatures. The results of particle size analysis for cadmium aerosol were as following. The highest particle counting for source temperature 20℃ was 399.75 × 10² in inlet temperature 100℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 50℃ was 399.70 × 10² in inlet temperature 50℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 70℃ was 411.14 × 10² in inlet temperature 100℃ and particle diameter 0.75㎛. The ranges of geometric mean diameter were 0.74-0.79㎛ in source temperature 20℃, 0.65-0.72㎛ in source temperature 50℃, and 0.65-0.80㎛ in source temperature 70℃. The smallest geometric mean diameter was 0.65㎛ in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the largest geometric mean diameter was 0.80㎛ in source temperature 70℃ and inlet temperature 100℃. The ranges of geometric standard deviation were 1.71-1.80 in source temperature 20℃, 1.27-1.61 in source temperature 50℃, and 1.27-2.29 in source temperature 70℃. The lowest geometric standard deviation was 1.27 in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the highest geometric standard deviation was 2.29 in source temperature 70℃ and inlet temperature 100℃. Generated aerosol for cadmium inhalation toxicology study was polydisperse aerosol with the above geometric standard deviation 1.2. The ranges of mass median diameter(MMD) were 1.75-2.25㎛ in source temperature 20℃, 1.27-1.61㎛ in source temperature 50℃, and 1.27-2.29㎛ in source temperature 70℃. The smallest MMD was 1.27㎛ in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the largest MMD was 2.29㎛ in source temperature 70℃ and inlet temperature 100℃. Cadmium chloride concentration in nebulizing solution affected the particle size and distribution of cadium aerosol in air. MMO for inhalation toxicology testing in OECD and EU is less than 3㎛ and EPA guidance is less than 4㎛. In our results, in source temperatures of 20, 50, 70℃, and inlet temperatures of 20, 50, 100, 150, 200, 250℃ were conformed to the those guidance.

Patch-based Cortical Source Modeling for EEG/MEG Distributed Source Imaging: A Simulation Study

  • Im Chang-Hwan
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권2호
    • /
    • pp.64-72
    • /
    • 2006
  • The present study introduces a new cortical patch-based source model for EEG/MEG cortical source imaging to consider anatomical constraints more precisely. Conventional source models for EEG/MEG cortical source imaging have used coarse cortical surface mesh or sampled small number of vertices from fine surface mesh, and thus they failed to utilize full anatomical information which nowadays we can get with sub-millimeter modeling accuracy. Conventional ones placed a single dipolar source on each cortical patch and estimated its intensity by means of various inverse algorithms; whereas the suggested cortical patch-based model integrates whole cortical area to construct lead field matrix and estimates current density that is assumed to be constant in each cortical patch. We applied the proposed and conventional models to realistic EEG data and compared the results quantitatively. The quantitative comparisons showed that the proposed model can provide more precise spatial descriptions of neuronal source distribution.

고선량율 원격강내조사의 코발트-60 이동선원에 의한 선량특성 (Dose Characteristics by the Co-60 Source Oscillations in High Dose Rate After Loading Irradiations)

  • 최태진;김옥배;노홍균
    • 한국의학물리학회지:의학물리
    • /
    • 제1권1호
    • /
    • pp.51-60
    • /
    • 1990
  • Dose distributions around Co- 60 moving source in high dose rate remote afterloading unit, Buchler 3K unit, were experimented with X-omat V films and calculations. In our experiments, film dosimetries have achieved to evaluated the axial dose distributions for source oscillations were 0, 3.5, 5.0 and 6.0 cm in periodically, In results, the dose distributions in axial of source movement showed apparently higher than in transverse direction caused by source locations, dwelling time and air gap in the applicator. In the calculations, the dose rate was derived by using the inverse square law, filteration corrections and Meisberger constant for scatter corrections as source movings. In our experiments and calculations, the average dose uncertainties were showed -2.1$\pm$1.9% in fixed sourdce, -2.9$\pm$1.8%, -7.4$\pm$6.1% and -6.7$\pm$4.6% at 3.5 cm, 5.0 cm and 6.0 cm source oscillations, but the calculations have showed very close to experimental dose rate within 4 cm distance from source.

  • PDF

EEG Current Source Imaging using VEP Data Recorded inside a 3.0T MRI Magnet

  • Han Jae Y.;Choi Young H.;Im Chang H.;Kim Tae-S.;Lee Soo Y.
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권2호
    • /
    • pp.95-99
    • /
    • 2005
  • We have performed EEG current source imaging on the cortical surface using visual evoked potentials (VEPs) recorded inside a 3.0 T MRI magnet. In order to remove ballistocardiogram (BCG) artifacts in the VEPs, an improved BCG template subtraction technique is devised. Using the cortically constrained current source imaging technique and pattern-reversal visual stimulations, we have obtained current source maps from 10 subjects. To validate the EEG current source imaging inside the magnet, we have compared the current source maps to the ones obtained outside the magnet. The experimental results demonstrate that there is a strong correspondence between the current source maps, proving that current source imaging is feasible with the evoked potentials recorded inside a 3.0 T MRI magnet.

효율적인 Source Head 개발에 관한 연구 (A Study on Development of Efficient Source Head)

  • 김귀정
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2007년도 추계 종합학술대회 논문집
    • /
    • pp.865-868
    • /
    • 2007
  • 본 연구는 이온주입(Ion Implanter)장비의 성능향상과 재현성 있는 Source Head를 개발하기 위한 방법이다. Source Head의 Life time이 부품 간 사용되는 Life time과 틀리기 때문에 보통 20일 정도 사용하고, 한번 Source Head를 재생하기 위해 교체되는 부품들도 고가일 뿐 만 아니라 50% 이상이 일회성으로 사용되고 있다. 본 개발에서는 원자의 유입방식을 공중 분산방식으로 적용함으로써 열전자의 손실로 발생하는 부분을 억제하는 효과와 Arc Chamber의 압력을 낮게 가지고 갈 수 있고 Chamber의 오염을 억제하는 효과를 얻을 수 있었다.

  • PDF

가려진 마이크로폰을 이용한 음원 위치 추적 (Sound Source Localization using Acoustically Shadowed Microphones)

  • 이협우;육동석
    • 음성과학
    • /
    • 제15권3호
    • /
    • pp.17-28
    • /
    • 2008
  • In many practical applications of robots, finding the location of an incoming sound is an important issue for the development of efficient human robot interface. Most sound source localization algorithms make use of only those microphones that are acoustically visible from the sound source or do not take into account the effect of sound diffraction, thereby degrading the sound source localization performance. This paper proposes a new sound source localization method that can utilize those microphones that are acoustically shadowed from the sound source. The experiment results show that use of the acoustically shadowed microphones, which receive higher signal-to-noise ratio signals than the others and are closer to the sound source, improves the performance of sound source localization.

  • PDF

고온 카본발열체의 발열특성에 관한 연구 (Study on the Heat Generation Characteristics of the Carbon Heating Source with High Temperature)

  • 배강열;이광성;신재호;정효민;정한식;전지수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.106-111
    • /
    • 2001
  • This paper is a study on the heat generation characteristics of the carbon heating source with high temperature. The main variables of this study are the input current and the amount of carbon heating source. As the results of the experiment in the waste rate of carbon heating source. The case of carbon heating source 300g was large than 500g. As the input current and the temperature are increased, the resistance values of carbon heating source were large. The Joule heat was represented the large value as the amount of heating source decrease with the input current. Finally, the heating source was represented the electrical steady state as the input current is increase.

  • PDF