• Title/Summary/Keyword: Soundproofing panel

Search Result 7, Processing Time 0.023 seconds

Study on Development of air-passing soundproofing panel (통풍형 방음벽 개발에 관한 연구 I)

  • Yoon, Je-Won;Sim, Sang-Deok;Kim, Young-Chan;Ku, Bon-Sung;Eom, Joo-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.638-643
    • /
    • 2011
  • The aluminum soundproofing panel used to the traffic noise reduction will judge with the material to improve because the CO2 emission is greater than other soundproofing panel such as plastic soundproofing panel. Also, if the air-passing soundproofing panel which can endure the fast wind velocity will be developed, it judged that it can reached to the target of low CO2 traffic technology development using the reduction of material cost and the lower consumption of steel. The objective of this study is to improve the soundproofing panel and to develop the air-passing soundproofing panel for the replacement of aluminum sound proofing panel which is more emit CO2 than other soundproofing panel. And, we tried to develop the reduction technology of CO2 emission through the development of air-passing soundproofing panel. At first, the flow and noise simulation were conducted for the purpose of the calculation of wind pressure on soundproofing wall and noise exposure level on receiver points according to the open ratio of air-passing soundproofing panel. And the 1st and 2nd mockup of air-passing soundproofing panel were made, and the design load test were conducted for these mockup.

  • PDF

A Study on the development and application of air-passing soundproofing wall (통풍형 방음벽 개발 및 적용에 관한 연구)

  • Yoon, Je-Won;Kim, Young-Chan;Kim, Keum-Mo;Jang, Kang-Seok;Ku, Bon-Sung;Eom, Joo-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.658-663
    • /
    • 2011
  • The purpose of this study is to develop an air-passing soundproofing panel with more improved structure to reduce the $CO_2$ emission and installation cost. To reduce the emission of $CO_2$ ; it is suggested to choose low $CO_2$ emission material relative to the aluminum and to reduce the materials by developing a specially designed air-passing soundproofing panel structure. First of all, we performed the flow analysis to predict the wind pressure according to the open angle of the air-passing soundproofing panel and the noise level analysis at the receiver point. To verify the simulation, a prototype of the soundproofing panel was made. The flow test in the wind tunnel and load test were performed. The economic evaluation for the installation of the air-passing soundproofing panel was performed and specifications of the installation was prepared. As the results of this research, it was verified that the wind load was reduced about 40% to that of the conventional one at 25m/s wind speed in the wind tunnel test. By applying the 4m span soundproofing wall with air-passing soundproofing panel and under the cost of 250 thousand $won/m^2$ instead of the conventional 2m span panel, the installation cost will always be lowered than the conventional one in the combination of (60:40~50:50) conventional to air-passing soundproofing panel from the economic evaluation. The 20% reduction of $CO_2$ was found by changing the 50% of aluminum soundproof panel to air-passing soundproofing panel.

  • PDF

A Reduction Effect in Noise Reflection by Different Shapes of Soundproofing-panel (도로소음원에 대한 방음패널 형상별 반사소음 저감효과)

  • Kim, Ilho;Park, Taeho;Chang, Seoil;Lee, Haein
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.2
    • /
    • pp.120-125
    • /
    • 2015
  • With rapid urbanization, the volume of traffic in urban area has been significantly increased. This in turn led to problem which can be described as Road Traffic Noise. Currently, to alleviate the road traffic noise damage, a demand for installation of soundproofing walls is rising. Among different shapes of soundproof walls being installed, the reflection-type acoustical insulation panel is highly drawing attentions of residents due to the fact that it does not obstruct their field of vision in contrast with the opaque acoustical insulation panel. On the other hand, improving the soundproofing wall of the reflection-type acoustical insulation barrier panel needs to be focused on since it has a possibility to cause a secondary damage by reflected sounds. Therefore, in this research, study has been carried out to improve the forms in order to minimize travelling of reflected sounds through changing the frontal surface shape and geometrical shape of the reflection-type soundproofing panel. A result from comparison between the normal reflection-type soundproofing panel and the improved soundproofing panel, with reduction effects in the noise reflection, showed that the curved type of soundproofing panel has an impact on reducing the noise up to 1.5 dB. Furthermore, from the research conducted, it appears that the increase and decrease in the reflected sounds can be changeable depending on various design factors. Thus, it turns out that the study shows a potential possibility to develop a reduction technology of the reflected sounds pertaining to overall condition on the soundproofing walls.

A Study on the Noise Reducing Method for HydroPower Station Building (수력발전소 건물 소음저감대책 연구)

  • Kim, Ki-Won;Cho, Sung-Su;Lee, Yeon-Ju;Park, Tae-Jin;Yi, Yong-Hun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.58-60
    • /
    • 2008
  • In this paper, In this investigation we measured and evaluated effects to residential area as result of noises caused by building vibration when the turbine of hydro-electric power station runs, and establishes the best plan of soundproof for that area. Furthermore, we analyzed differences between estimated noises and actual noises and its causes before constructing the soundproofing panels so that it helps to start building the soundproofing panels and similar constructions in the future.

  • PDF

Post Occupancy Evaluation of Hanok in Rural Area and Comparative Study on the Perception of Hanok -Hanok Residents and Architectural Designers Comparison Based on- (농촌한옥의 정주성 평가 및 한옥에 대한 인식도 비교 연구 -한옥거주자와 건축설계자간의 비교를 중심으로-)

  • Lee, Chang-Jae;Choi, Il
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.12 no.2
    • /
    • pp.77-84
    • /
    • 2010
  • Hanok has been widely distributed as a support policy by local governments for the purpose of improving residential environment. In this study, Hanok in a rural area was founded was to evaluate the user's satisfaction. Hanok between residents and the perception of architects and tries to figure out the difference. Current Hanok residents showed higher satisfaction, but they showed negative response for high construct cost, plane form of building, insulation performance and noise. According to the comparison of recognition between residents and architectural designers, they showed differences in "Low soundproofing", "lack of storage space", "Equipment", "Tile", "The modularity of the flat panel design", and "The modularity of construction materials" and it was examined that architectural designers group had higher preference for traditional materials and forms. For succeeding to the traditional architectural factors of Hanok and distributing it as modern house, the research on use of modern materials and modulation of plane and members should be performed for reducing construction cost and improving insulation performance.

A preliminary study on the measurement method for determining the absorption coefficient of sound barrier panels (방음판의 흡음률 측정방법 제안을 위한 기초 연구)

  • Yang Ki Oh;Ha Geun Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.152-160
    • /
    • 2023
  • Sound barrier walls are the most basic way to cope with noise problems in urban residential environments. The most important acoustic function of sound insulation board is represented by sound transmission loss and sound absorption coefficient. However, Korea has not yet established a standard for measuring the sound absorption rate of sound insulation boards. In addition, even in the European standard, where the overall acoustic standard of soundproofing boards has already been established, the sound absorption rate is applied only to the standard for measuring the sound absorption rate of general building finishing materials, and a separate measurement method considering the characteristics of soundproof walls and soundproofing boards is not presented. The sound absorption coefficient should be evaluated by summing up the energy absorbed into the material as well as the energy transmitted through the material, but the current European standard has a problem in that the transmitted sound energy is not taken into account. In this paper, we reviewed the sound absorption coefficient measurement standards of sound insulation boards currently being presented, and verified the difference between the results and the new measurement method considering transmission sound for sound insulation boards actually used in Korea.

A Study on the Soundproofing Plate Techniques for Noise Reduction of Power Transformers (전력용 변압기 소음저감을 위한 차음판 기술에 관한 연구)

  • Kweon, Dong-Jin;Koo, Kyo-Sun;Kim, Jung-Chon;Kim, Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.47-55
    • /
    • 2008
  • According to the increase of power demand and expansion of downtown, it is necessary to install transformers additionally in operating substations and construct substations in residential area. But the public complaint has been increased due to the transformer noise of the substation. KEPCO has used a vibration preventing pad, various soundproof walls and an enclosure to transformers in outdoor substations, and a soundproof door, shutter and wind-path soundproof equipment in indoor substations to block the sound propagation from the transformers. But these noise reduction methods are not satisfied. It should be considered to reduce transformer noise itself. To shut out sound emitted from transformers, we developed a soundproof technology that wall up reinforcing bar by steel sheet. For the practical application of it, we analyzed the vibration characteristics of a transformer tank and reduction of noise according to soundproof plate. As a result, it is confirmed that the technology can reduce 11 [dB] of transformer noise.