• 제목/요약/키워드: Sound reduction

검색결과 827건 처리시간 0.028초

주방환기 시스템의 소음 저감과 실내 음장분포 예측에 관한 연구 (A Research on the Noise Reduction of a Kitchen Ventilation System and the Prediction of Sound Distribution in a Kitchen and Room)

  • 송화영;이동훈;이창근;김동윤;홍병국
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.494-499
    • /
    • 2005
  • This paper introduces a study for the noise reduction of a range hood for household. Generally, range hoods have a built-in sirocco fan from which harsh noises are generated. Though the harsh noises have low noise level, these kinds of noises make most of the users nervous. For the purpose of noise reduction, in this study, a perforated plate system is installed in the fan housing of range hood. From the experimental results, it is confirmed that the noise level emitted from the range hood was decreased more than 10dB(A) in all 1/3 octave bands due to the effect of noise reduction by perforated plate systems.

  • PDF

공동주택의 바닥충격음 저감성능에 관한 연구 (A Study on the Reduction Performance of Floor Impact Sound in Apartment Building)

  • 이종균
    • KIEAE Journal
    • /
    • 제3권3호
    • /
    • pp.27-34
    • /
    • 2003
  • As a result of supply-oriented housing policy of Korea since the 1960s, the number of apartment housing units has increased up to six million as of the end of 2001 that is 55% of total housing units. Although the needs of placid living environment increases according to the enhancement of residents' living standard, most of construction firms as apartment suppliers plan and design apartment buildings to maximize the profit and give rise the residents' petitions and troubles about floor impact noise. In consequence, the floor impact noise becomes one of principal problems of living environment, and the government placed the obligation of installing the noise isolation materials between upper and lower floors in 2001 and controlling the floor impact noise lower than 60dB from the middle of 2004. In other to provide the fundamental research data to enhance the reduction performance of floor impact sound, in this paper, the factors that influence on the floor impact noise are derived from the survey of many research papers and the performance of various materials used as noise reduction objects are compared and surveyed with the factors in the experiments in field and laboratory.

높은 입사 음압에서의 미세 천공판을 이용한 흡음 기구의 설계 (Design of a Micro-perforated Panel Absorber at High Incident Sound Pressure)

  • 박순홍;서상현;장영순
    • 한국소음진동공학회논문집
    • /
    • 제20권10호
    • /
    • pp.983-990
    • /
    • 2010
  • Reduction of acoustic loads of space launch vehicles can be achieved by acoustic absorbers satisfying strict cleanness requirements. This limited the use of general porous materials and requires non-porous sound absorbers. Micro-perforated panel absorbers(MPPA) is one of promising sound absorbers satisfying the cleanness requirement for launch vehicles. However, its applicability was limited to low sound pressure levels according to the acoustic impedance model of micro-perforated panels. In this paper the applicability of micro-perforated panel absorbers at high incident sound pressure was investigated in experimental ways. The absorption characteristics of a micro-perforated panel absorber was simulated according to its design variables, e.g., minute hole diameters and aperture ratios. It was shown that optimal design can be readily done by using proposed design charts. Experiments were conducted to measure acoustic properties of the designed micro-perforated panel absorbers. The results showed that acoustic resistance increases rapidly as incident sound pressure level does but change of acoustic reactance can be neglected in a practical point of view. This caused the decrease of peak value of absorption coefficient at high incident sound pressure level, but the amount of reduction can be accepted in practice. The major advantage of the micro-perforated panel absorber(wide absorption bandwidth) was still kept at high sound pressure level.

실험실 실험을 통한 벽체 차음성능 측정의 신뢰성 향상을 위한 실험적 연구 (An Experimental Study to Improve Measurement Reliability for the Airborne Sound Insulation Performance by Laboratory Test)

  • 김항;박현구;구희모;김선우
    • 한국소음진동공학회논문집
    • /
    • 제24권1호
    • /
    • pp.35-44
    • /
    • 2014
  • Sound pressure levels in the receiving room while testing airborne sound insulation performance are varied by the measuring points. This may increase the measurement error, then decrease the measurement reliability. With this reason the research has carried out on the method to reduce deviations of sound pressure level in the ISO type rectangular laboratory focusing on the measurement of airborne sound insulation performance. Tests were made to see the effect of sound absorption in the receiving room, loudspeaker locations, microphones locations and flanking transmission path. Consequently, it was resulted that sound absorption in the receiving room and the loudspeaker location have influence on the sound level deviations especially in the low frequency. The microphone location was very important to get measurement reliability. The effective measuring point, which the sound level difference with average sound pressure level is within 2 dB, could yield most reliable average sound pressure level. Therefore it is necessary to find the effective measuring points in the receiving room. Flanking transmission path should be sealed using sound absorber or magnet etc. to prevent from lowering the sound insulation performance.

틸팅열차 측면재의 차음 전략 (Sound Insulation Strategy of the Side Panels in a Tilting Train)

  • 김석현;서태건
    • 산업기술연구
    • /
    • 제31권A호
    • /
    • pp.33-38
    • /
    • 2011
  • In an express tilting train, side wall insulating the noise from the exterior sound source consists of two parts. One is the layered composite panel including aluminum honeycomb, glass wool and nomex honeycomb. The other is the double glazed window. In this study, sound insulation performance of the two parts is investigated by mass law and experiment. Based on ASTM E2249-02, the intensity sound transmission loss (TL) is measured on the specimens of the two parts. Mass law deviation (MLD) is considered in order to compare the sound insulation performance in respect of weight. Contribution of each part to the sound insulation is analyzed and the sound insulation strategy for the interior noise reduction is investigated.

  • PDF

An Improvement Method of Sound Quality of the High-speed Coastal Passenger Ship

  • Kim, Yoon-Seok;Kim, Sa-Soo
    • International Journal of Ocean Engineering and Technology Speciallssue:Selected Papers
    • /
    • 제3권1호
    • /
    • pp.56-62
    • /
    • 2000
  • The trends of recent passenger ships are becoming speedy and luxury style to enhance comfortableness in cabin. In order to meet these trend, ship designer has to improve the sound quality as well as to reduce the sound pressure level in cabins. In this paper, the trend of noise and sound quality of real high-speed coastal passenger ships are measured and analyzed, while running on their regular courses. The sound quality parameters such as loudness, roughness, fluctuation strength, and sharpness are evaluated by Zwicker loudness calculation. In addition, we try to find sensitive critical frequency band for the improving sound quality by using signal editing. Finally, the expected effective design methods are proposed to designer for the improving sound quality of passenger ships.

  • PDF

Investigation of Sound Absorption Ability of Hinoki Cypress (Chamaecyparis obtusa) Cubes

  • JANG, Eun-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • 제50권5호
    • /
    • pp.365-374
    • /
    • 2022
  • Today, commercialized Hinoki cypress cubes are used for fragrance, humidification, and pillows in Korea. In this study, the sound absorption ability of Hinoki cypress (Chamaecyparis obtusa) cubes was examined. The three groups of Hinoki cypress cubes were prepared depending on their dimension (L: 9 × 9 × 9, M: 7 × 7 × 7, S: 4 × 4 × 4 mm). Their sound absorption coefficient was examined after filling 6, 8, 10, and 12 cm height in impedance tubes, respectively. Overall, the sound absorption ability depending on dimension was superior in the M group compared to the L and S groups. Also, as the filling height increased, the sound absorption capacity increased. In sum, noise reduction coefficients (NRC) of all Hinoki cypress cubes were 0.41-0.59. Thus, this research found that Hinoki cypress cubes have a sound-absorbing function.

방음실에 의한 공장설비 소음의 감쇠 효과에 관한 연구 (A Study on Sound Attenuation of Plant Noise by Enclosure)

  • 윤세철;이해경
    • 한국안전학회지
    • /
    • 제9권4호
    • /
    • pp.119-124
    • /
    • 1994
  • The considerations in the noise control by enclosure are the rise of temperature and sound pressure, transmission loss, absorption coefficient of the materials, the structure of the soundproof panels, an opening and coincidence frequency. But it is very difficult that we obtain the accurate data about those in design, so, the noise reduction after enclosing does not correspond with the calculation. The difference of the noise reduction between the calculation and the measurement was 8.2dBA, and we can obtain the approximate result as the following formula which correct 10dBA, safely.

  • PDF

154kV 전력용 변압기의 부하소음 및 냉각팬 소음 분석 (An Analysis on the Audible Sound Due to Load and Cooling Fan for 154kV Power Transformers)

  • 구교선;우정욱;곽주식;김경탁;권동진
    • 전기학회논문지P
    • /
    • 제59권3호
    • /
    • pp.298-304
    • /
    • 2010
  • Recently, the audible sound level of power transformer has been reduced due to development of new material and enhancement of manufacturing technology. There is lack of research on the audible sound of winding and cooling fan because the research on reduction of audible sound is concentrated on the core sound. Therefore this paper describes 3 kinds(core, winding and cooling fan) of transformer sound source. Also this paper analyzes the effect of load sound and cooling fan sound on the total transformer sounds. As the results, total sound level of 79dBA class transformer rises 0.2~0.3dB due to effect of load sound and rises 2.1~3.5dB due to effect of cooling fan sound. Also, total sound level of 55dBA class transformer rises 2.3~2.9dB due to effect of load sound and rises 1.9~3.5dB due to effect of cooling fan sound.

주거단지 입지특성에 따른 소음환경 실태조사 - 도로변 아파트단지를 대상으로 - (A field survey on the noise environment of apartment according to site location)

  • 박수빈
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 1994년도 학술발표대회논문집 상
    • /
    • pp.11-17
    • /
    • 1994
  • The increase of road traffic niose in residential area has been considered to be a serious environmental problem to deteriorate a living condition. The understanding of noise environment in multiple family housing is needed for noise reduction. This study attempts to find out the characteristics of noise environment. For this purpose, the field survey has been carried out to investigate the noise environment(sound level, quality of sound) and the residents' responses(noiseness, annoyance) for noise environment based on 173 households living in 3 apartment compounds built in Pusan according to site location. The major findings are as follows : 1. The sound levels by road traffic noise were measured by dB(A) and dB(Lin). The sound levels were : 77.0dB(A), 86.6dB(Lin) in D-Apt, 73.3dB(A), 82.6dB(Lin) in K-Apt, and 59.1dB(A), 74.6dB(Lin) in M-Apt. Especially, the difference between dB(A) and dB(Lin) was very big in the cae of M-Apt with a barriers for traffic noise reduction. 2. The internal sound levels were shown the soudn attenuation by horizontal distance and by opening or shuting condition of windows.

  • PDF