• Title/Summary/Keyword: Sound radiation

Search Result 295, Processing Time 0.026 seconds

Cardiorespiratory Responses of Qi-training: A Pilot Study

  • Lee, Myeong-Soo;Kim, Soo-Keun;Kim, Hye-Jung;Moon, Sun-Rock
    • Advances in Traditional Medicine
    • /
    • v.4 no.1
    • /
    • pp.18-21
    • /
    • 2004
  • Six volunteers (mean $age=25.7{\pm}1.7$, $height=173{\pm}1.9$ and $weight=63.4{\pm}2.3{\;}kg$) participated in a graded exercise test and one hour of basic form of ChunDoSunBup (CDSB) Qi-training to investigate the cardiorespiratory responses and exercise intensity of Qi-training, a Korean traditional psychosomatic training. In the maximal exercise, the trainee showed $96.2{\pm}8.89{\;}l/min$ in ventilation (VE), $46.0{\pm}4.4$ in breath frequency (BF), $1.31{\pm}0.05$ in respiratory exchange ratio (RER), $180.7{\pm}3.0$ in heart rate (HR), and $2.6{\pm}1.1{\;}l/min$ or $40.7{\pm}2.3{\;}ml/kg/ml$ in oxygen consumption $(VO_2)$. Qi-training induced significant changes in BF, RER, HR, and $VO_2$. The exercise intensity of Qi-training were 42.3%, 46.9% and 38.7% of $HR_{max}$ during the sound exercise, slow motion (haeng-gong) and meditation respectively and the average was 46.2% of $HR_{max}$. We conclude that Qi-training is an aerobic exercise of a light (mild) intensity exercise, and it leads to decrease the metabolic rate in the trainee by breathing efficiently and relaxing them. In addition, Qi-training may affect cardiorespiratory function of BF, RER, HR and $VO_{2max}$ in trainees.

Diagnostic Application of Temporomandibular Joint Disorder and Ultra Sound Guided Oral &Maxillofacial application (초음파를 이용한 턱관절질환의 진단과 초음파 가이드의 활용)

  • Seong, Tae-Hwan;Park, Jung-Hyun;Kim, Sun-Jong
    • The Journal of the Korean dental association
    • /
    • v.55 no.11
    • /
    • pp.789-799
    • /
    • 2017
  • Ultrasound images are noninvasive, can be observed in real time, have no radiation exposure, do not cause pain, and are not restricted in use depending on the patient's prosthetic implant or medical condition. Since the use of ultrasound in the dental field was first applied for tooth preparation in 1957, the use of diagnostic ultrasound for the first time in 1963 has been reported. Currently, it is used in the diagnosis of soft tissue lesions such as malignant tumor or salivary gland disease, fine needle aspiration test, temporomandibular joint disease, lymph node metastasis, measurement of muscle thickness and inflammatory diseases, differentiation of periapical cyst and granulation tissue, measurement of periodontal tissue thickness. The ultrasound image can be visualized in real time. The clinician can explain the structure to the patient while consulting the patient and consult the patient. When injecting the drug into a specific site or aspirating a specific site or substance, So that it can be confirmed and practiced. Recently, ultrasonic equipment specialized in the dental field has been developed and marketed, and it is expected that the use of ultrasonic waves will become active in the dentistry. In the future, development of popular equipment with size and frequency suitable for dental diagnosis and various researches on maxillofacial ultrasonic anatomy. If clinical studies are continuously carried out to demonstrate efficacy, ultrasound is expected to aid in accurate diagnosis and treatment throughout the dentistry.

  • PDF

Comparison of Track Vibration Characteristics for Domestic Railway Tracks in the Aspect of Rolling Noise (철도 전동 소음의 관점에서 해석한 국내 철도의 진동 특성 비교)

  • Ryue, Jungsoo;Jang, Seungho
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.2
    • /
    • pp.85-92
    • /
    • 2013
  • An important source of noise from railways is rolling noise caused by wheel and rail vibrations induced by acoustic roughness at the wheel-rail contact. The main contributors to rolling noise are the sleepers, rail, and wheels. In order to analyze and predict rolling noise, it is necessary to understand the vibrating behaviors of railway tracks, as well as of the wheels. In the present paper, theoretical modeling methods for railway track are reviewed in terms of rolling noise; these methods are applied for the three representative types of domestic railway tracks operated: the conventional ballasted track, KTX ballasted track and KTX concrete track. The characteristics of waves propagating along rails are investigated and compared among the types of tracks. The tracks are modeled as discretely supported Timoshenko beams and are compared in terms of the averaged squared amplitude of velocity, which is directly related to the sound radiation from the rails.

On the Solution Method for the Non-uniqueness Problem in Using the Time-domain Acoustic Boundary Element Method (시간 영역 음향 경계요소법에서의 비유일성 문제 해결을 위한 방법에 관하여)

  • Jang, Hae-Won;Ih, Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.1
    • /
    • pp.19-28
    • /
    • 2012
  • The time-domain solution from the Kirchhoff integral equation for an exterior problem is not unique at certain eigen-frequencies associated with the fictitious internal modes as happening in frequency-domain analysis. One of the solution methods is the CHIEF (Combined Helmholtz Integral Equation Formulation) approach, which is based on employing additional zero-pressure constraints at some interior points inside the body. Although this method has been widely used in frequency-domain boundary element method due to its simplicity, it was not used in time-domain analysis. In this work, the CHIEF approach is formulated appropriately for time-domain acoustic boundary element method by constraining the unknown surface pressure distribution at the current time, which was obtained by setting the pressure at the interior point to be zero considering the shortest retarded time between boundary nodes and interior point. Sound radiation of a pulsating sphere was used as a test example. By applying the CHIEF method, the low-order fictitious modes could be damped down satisfactorily, thus solving the non-uniqueness problem. However, it was observed that the instability due to high-order fictitious modes, which were beyond the effective frequency, was increased.

Computational study on prediction of electrical beam steering phenomenon of parametric array sound source (파라메트릭 어레이 음원의 전기적 빔 조향 현상 예측을 위한 수치 해석 기법 연구)

  • Been, Kyounghun;Ohm, Won-Suk;Moon, Wonkyu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.5
    • /
    • pp.485-493
    • /
    • 2019
  • The parametric array phenomenon refers to the generation of a high directivity low frequency wave from a small size radiation plate using the nonlinearity of the medium. In order to improve the usability of parametric array, the beam steering method of low frequency wave is researched, and the beam steering phenomenon is predicted easily using the PD (product directivity) model. However, the PD model can only be applied to Gaussian sources under quasi-linear conditions. Also, the prediction accuracy of low frequency wave beam width is poor. In this paper, a method for predicting the beam steering characteristics of a parametric array that can overcome the limitation of the PD model is investigated. For this purpose, the numerical analysis algorithm of the KZK (Khokhlov-Zabolotskaya-Kuzentsov) equation widely used for parametric array phenomenon prediction is improved. Thus, the beam steering characteristics are calculated by applying the electrical beam steering condition and comparing experimental results. As a result, the numerical analysis using the modified KZK equation algorithm in this study confirms that the beam steering phenomenon can be predicted even in a parametric array source that does not correspond to the quasi-linear condition.