• Title/Summary/Keyword: Sound pressure Level

Search Result 690, Processing Time 0.03 seconds

An Experimental Study on the Acoustic Characteristics of a Reciprocal Compressor (냉장고용 왕복동식 압축기의 소음특성에 관한 실험적 연구)

  • 박철희;차용웅;홍성철;주재만;김영헌;박윤서
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.196-201
    • /
    • 1997
  • In point of noise and vibration, it is easy to occur a noise and vibration, because the reciprocal compressor is composed of crank shaft, rod piston and etc. Therefore, it is important to understand the mechanism of reciprocal compressor. In this study, we measured the sound pressure level of compressor. There are two dominent frequencies. The first of one results from the suction part. In suction process, the suction valve flutteres, and it produces the noise of the first frequency. The other results from the structural vibration of the shell resonated by discharge pipe. Thus, to reduce the noise of compressor, it will be most efficiency to redesign muffler for the first frequency and discharge pipe for the second frequency.

  • PDF

Damping Patch Placement on Outdoor Unit of Air-conditioner by Using Structural Intensity Technique (구조 인텐서티법을 이용한 에어컨 실외기의 제진재 적용)

  • 김규식;진심원;정인화;이정우;강연준
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.7
    • /
    • pp.577-585
    • /
    • 2004
  • In this paper, reactive shearing structural intensity method is extended to damping patches placement on outer panels of outdoor unit of air-conditioner to reduce its structural borne noise. The structural intensity is calculated from the normal velocities of structures that are measured by using a laser scanning vibrometer, and $textsc{k}$-space (wave-number domain) signal processing is used to obtain the spatial derivatives in formulation of structural intensity. This method is applied to the outdoor unit of air-conditioner on shaker-exciting mode and operating mode. and then damping patches are placed over area of high reactive shearing structural intensity for reducing the radiated noise. Experimental results show the largest reduction of sound pressure level of an outdoor unit by appling small damping patches to optimal position.

Development of the Simple Prediction Program to Prevent Construction Noise in Site (건설소음 예방을 위한 현장용 간이 합성소음 예측프로그램 개발)

  • Bang, Jong-Dae;Song, Hee-Soo;Gyeong, Tae-Ug;Lim, Byung-Gun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.59-65
    • /
    • 2005
  • The research is an objective which prevents a construction noise by developing prediction program on utility, helps comprehension of construction noise by case study. The program developed with Visual Basic of the Excel Logic. The standard noise is a data with report of the construction machine (National Institute of Environmental Research), construction noise of sound pressure level applied the distance decrease of the point source. The decrease effect of the barrier noise wall used the data of 5, 10, 15, 20dB where the diffraction is reflected. used a program, case study is suggested Prevention method to prevent noise of construction site.

  • PDF

An Experimental Study on the Acoustical Characteristics in the Main Hall of Catholic Church (성당본당의 실내음향 특성에 관한 실험적 연구)

  • Shin, Young-Jin;Park, Hyeon-Ku;Choi, Hyung-Wook;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.468-473
    • /
    • 2000
  • Recently the acoustic design has been considered the important part of architectural design. However, in the design of Catholic churches the exterior beauty is still main point. This study aims to find out the acoustical characteristics in the main hall of Catholic churches. Six catholic churches were selected for this experiment and the physical parameters which represent the acoustic characteristics of room were compared by the plan type and the architectural factor. The physical parameters compared and analyzed were SD(Stand deviation) of SPL(sound pressure level), RT(reverberation time), $D_{50}$(definition), $C_{80}$(clarity) and STI(speech transmission index).

  • PDF

Vocal Function After Surgical Correction of the Bowing Vocal Cords (성대 Bowing의 술전.후 음성기능)

  • 정광윤;최종욱;한동수
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.6 no.1
    • /
    • pp.9-15
    • /
    • 1995
  • Bowing of the vocal cords may be due to aging. atrophy. bilateral superior laryngeal nerve paralysis. injudicious vocal cord surgery, of an idiopathic cause. The bowing usually produces a dysphonia characterized by breathiness due to air escape : however, it can produce aphonia. This report reviews vocal function after surgical correction of bowing of the vocal cords for diagnosis and management. The vocal function of 13 patients with sulcus vocalis and 12 patients with vocal cord atrophy was evaluated with the use of a test battery of multidimensional evaluation items. The voice was improved postoperatively in most patients. The voice improvement was reflected objectively in maximum phonation time, mean air flow rate during phonation, stroboscopic findings. sound pressure level range and fundamental frequency range of phonation, and results of acoustic analyses of tape-recorded voice. The vocal function after surgical correction of the sulcus vocalis and vocal cord atrophy was improved postoperatively in most patient, but the results were not satisfactory.

  • PDF

Slim Electronic Panel Cooler with Parallel Flow Condenser (PF 열교환기가 적용된 슬림형 중계기 냉각기)

  • Cho, J.P.;Kim, N.H.;Lee, J.H.;Lee, Y.J.;Mook, I.K.;Lim, W.K.;Lim, S.S.
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.483-488
    • /
    • 2006
  • In this study, newly-developed slim electronic panel cooler with aluminum PF condenser and evaporator was tested and the results are compared with imported panel cooler with fin-tube heat exchangers. The PF heat exchangers significantly (approximately 45%) reduced the refrigerant charge. The air-side pressure drop was also reduced, which resulted in the reduction of the sound level of the panel cooler. The effect of the condenser size was also investigated.

  • PDF

Introduction of a recent active loudspeaker measurement and assessment method based on IEC60268-21 (IEC60268-21 기반 최신 액티브 스피커 측정 및 분석 기법 소개)

  • LEE, Sinlyul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.3
    • /
    • pp.241-246
    • /
    • 2021
  • Modern loudspeaker systems are changing an active loudspeaker system that have multiple input channels and power amplifier. So, we cannot measure these active loudspeakers with IEC 60268-5 standard. This paper introduces an IEC 60268-21 standard that can measure an active loudspeaker having many analog and digital and wireless or wired inputs and having various control parameters.

A Study on the Noises of Fishes (어류가 내는 소리에 관하여)

  • CHO, AM;CHANG, Jee-won
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.8 no.1
    • /
    • pp.14-22
    • /
    • 1972
  • For the development of acoustic fishing method, the noises of fishes have been recorded and analy/'ed by many scientists. Some specimens of fishes were selected as such Cyprinus carpio, Ctenopharyngodon idellus Carassius carassius, and pagrosol1ms major in this experiment. The noises such as feeding noise, driving away noise, jumping noise and fi llip noise were recorded by the tape recorder, Sony Model 262, through the underwa te r microph I one, Oki ST 6582, and analyzed in frequencies bv octave band analyzer, Rion SA-55, and sound pressure level of source by sound level meter, Rion NA-opNN The supplied feed was placed within 5em apart from the hydrophone. The result of analyzed noises were as follow. Cyprinus carjJio; Feeding noise 250- 500 cps, 92- 99 dB Driving away noise 125-2, 000 eps, 101-112 dB Jumping noise 125-2, 000 eps, 99-116.5 dB Ctenopharyngodon idcllus; Driving away noise 125-1, 000 cps, 96-109 dB Carassius carassius; Feeding noise 250- 500 cps, 91. 5- 99.5 dB Driving away noise 125-1, 000 eps, 99-108 dB Carassius auratus Feeding noise 250 eps, 94-101 dB Driving away noise 125-1, 000 cps, 98-110 dB Pagrosomus major Feeding noise 230-500 cps, 90-101 dB Fillip noise 500 cps, 98-108 dB (1) Feeding noise was produced as like as snap noise of twig and gulping down saliva noise in human and dominant frequency range of the noise is 250-500 cps and noise level 90-101 dB. (2) It was found that feeding noise were not a monotonic but a complex tones though fish took the same food. (3) Driving away noise was produced not so keen and the wave form of the noise is rising very sharp and big amplitude in the oscillograph. Dominant frequency range of this noise was about 150-1, 000 cps and noise level 96-112 dB except thut of carp. (4) The frequency of snapper's fillip noise, when it produced by caudal fin in swimming at the surface of water, was 500 cps and noise level 93-108 dB snd that of jumping noise of carp about 150-2, 000 cps and noise level 99-116.5 dB.

  • PDF

Heavy-weight Impact Sound Characteristics of Floor Structure of a Small-Sized Wall-Slab Apartment Building having Joist Slab (장선슬래브를 갖는 소형평형 벽식구조 아파트 바닥구조의 중량충격음 특성)

  • Chun, Young-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.1
    • /
    • pp.8-15
    • /
    • 2020
  • In the present paper, as a way of reducing heavyweight impact sounds, in particular, among floor impact sounds which have come to the forefront as a social issue recently, a floor joist slab is proposed that is expected to bring an effect of reducing heavyweight impact sounds through a shift in the natural frequency by installing a floor joist on a flat-type slab to increase the rigidity of the floor slab, differently from the existing method that increases the thickness of floor slab, and the heavyweight impact sound characteristics depending on the floor joist height and interval are interpretively analyzed. As a result of the analysis, though a trend is shown where the sound pressure level decreases as the slab thickness of floor joist increases, and as no difference is shown when thickness is above a certain value, it is thought that there is a threshold for the effect of an increase in floor thickness on blockage of heavyweight impact sounds. Also, as an increase in floor rigidity resulting from an increase in the floor joist height and a decrease in the interval does not lead to a consistent increase in the performance of blocking heavyweight impact sounds, it is thought that a different floor joist height and interval should be applied to each type of house to expect optimum performance of blocking heavyweight impact sounds, and an increase of 100mm in the floor joist height or a decrease of about 100mm in the interval is expected to bring an effect of reducing heavyweight impact sounds by about 1dB to 2dB.

An Experimental Study on the Supersonic Jet Noise from Multihole (다공 초음속 분류소음에 관한 실험적 연구)

  • Kwon, Y.P.;Suh, K.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.2
    • /
    • pp.96-105
    • /
    • 1992
  • The objective of this paper is to study experimentally on the noise characteristics of supersonic jet from multihole orifice in the range of jet pressure from $at_g$ to $at_g$ in the reverberation room. At first, the single orifice jets are investigated for various hole diameter from 3.8mm to 10mm. Through the noise spectrum, the turbulent mixing noise and the shock associated noise is analyzed. The noise for confined jets into a tube of diameter 30mm or 90mm with length 2m is investigated in comparision with that for the free jets. The sound power level is measured and compared with thoretical models for free jet. At second, multihole orifice jets are investigated to study the effect of multijet on noise reduction. The spectrum and power level of multijets are measured and compared with single jets. The multi-jets in a confined pipe are also investigated. It is found that the noise spectrum is significantly altered by increasing the number of jet with decrease in jet diameter and also by confining the jet into tube.

  • PDF