• 제목/요약/키워드: Sound power

검색결과 811건 처리시간 0.024초

조화분포이동하중을 받는 무한보에서의 음향방사 (Sound Radiation From Infinite Beams Under the Action of Harmonic Moving Line Forces)

  • 김병삼;이태근;홍동표
    • 소음진동
    • /
    • 제3권3호
    • /
    • pp.245-251
    • /
    • 1993
  • The problem of sound radiation from infinite elastic beams under the action on harmonic moving line forces is studies. The reaction due to fluid loading on the vibratory response of the beam is taken into account. The beam is assumed to occupy the plane z=0 and to be axially infinite. The beam material and elastic foundation are assumed to be lossless and Bernoulli-Euler beam theory including a tension force (T), damping coefficient (C) and stiffness of foundation $(\kappa_s)$ will be employed. The non-dimensional sound power is derived through integration of the surface intensity distribution over the entire beam. The expression for sound power is integrated numerically and the results examined as a function of Mach number (M), wavenumber ratio$(\gamma{)}$ and stiffness factor $(\Psi{)}$. Here, our purpose is to explain the response of sound power over a number of non-dimensional parameters describing tension, stiffness, damping and foundation stiffness.

  • PDF

TV set의 스피커에 의한 소음 대책 설계 (A Design Approach of TV Set for Reducing Noise Induced from Speaker)

  • 김재환;김종연;이중근;이동호;곽순찬;박상덕;최진성;박종성
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.561-567
    • /
    • 1998
  • Recently, TV makers have tried for high sound quality and power, However, due to the high power of the speaker the structure of set brings about a sound vibration problem. Therefore, this paper illustrates the sound vibration phenomenon for a monotype TV set and suggests guide lines for reducing the sound vibration in the design of TV sets,

  • PDF

평판에 충돌하는 원형분류의 공력소음에 관한 실험적 연구 (Au Experimental Study on the Aerodynamic Noise by a Circular Jet Impinging on a Plate)

  • 이동훈;권영필;한희갑
    • 소음진동
    • /
    • 제7권1호
    • /
    • pp.71-79
    • /
    • 1997
  • The objective of this study is to investigate experimentally the effect of surface conditions of the plate on the impinging jet noise. The experimental results about the spectrum, the sound pressure level and the directivity are pressented and discussed in relation with the surface conditions. Regardless of the surface conditions, the pure tones of high level are generated at the same frequency band and the overall sound power level of impinging jets is much higher than that of the free jet. However, the velocity dependence of the sound pressure level and the directivity are different between smooth surfaces and rough surfaces. The dependence of sound pressure level on the jet velocity shows that the smooth surface generates quadrupole-type sound like free jets. However, the perforated or the rough surface radiates sound power exactly proportional to the sixth power of the jet velocity, indicating that the source is fixed dipole type. The directivities of 1/3 octave band sound pressure level for both the free and impinging jet show the peak directivity at 115$^\circ$ upstream, probably due to the refraction associated with velocity gradient.

  • PDF

광음향기법을 이용한 한국형 고속전철의 실내소음 예측 (Interior noise prediction of the high speed train using ray method)

  • 김관주;박진규
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.157-164
    • /
    • 2000
  • This study is about predicting the interior pressure level of the korean high speed train using ray acoustic method. The motor car and the motor and passenger cabin are investigated under the environment of passing open countryside and inside tunnel of 350 km/hr. Calculated sound levels are compared with the proposed sound levels and suggestions about the transmission Joss values of isolating panels inside motor car and the guide lines of allowed sound power limit of motor equipments are provided. Results of TPI car show calculated interior sound level is below the proposed values for both cases of open countryside running and inside tunnel. Since ray acoustic method calculated only air borne noise component, real sound level of the motor car may be higher than prediction. Passenger cabins of TMI, TM5 show higher sound level than the proposed values, so window method was carried out to find the contribution of each panel components and point out the remedy of transmission path. Reduction of sound power of motor equipments should be condisered at the same time.

  • PDF

적응 디지탈 필터와 DSP 칩을 이용한 폐음 분석기 설계 (Design of Lung Sound Analyzer Using Adaptive Digital Filter and DSP Chip)

  • 김규한;조일준
    • 대한의용생체공학회:의공학회지
    • /
    • 제10권2호
    • /
    • pp.151-156
    • /
    • 1989
  • 본 연구에서는 폐 및 기관지 질환 환자에 대한 객관적인 진단을 위한 폐음분석 시스템을 설계하였다. 적응 필터링 기법에 의하여 순수한 폐음을 분리하였고 이의 power spectrum을 구하기 위하여 TMS320C25 DSP 칩과 IBM PC를 사용해서 폐음 분석기를 구성하였다. 실험결과 적응 격자 위너 필터는 10차의 적은 차수로도 분리가 가능하였고 정상 폐음은 100-200 Hz, 급성 섬유성 폐렴폐음(crackle)은 100-400 Hz, 기관지 협착증(wheeze)폐음은 150-600 Hz에서 주파수범위를 갖는 power spectrum의 양상을 통해 각각 패턴 분류할 수 있었다.

  • PDF

수음실 잔향 시간변화에 따른 바닥충격음레벨 특성 - 잔향실을 중심으로 - (Floor Impact Sound Pressure Level Characteristics by the Change of Reverberation Time in a Reverberation Chamber)

  • 정정호;김정욱;정재군
    • 한국소음진동공학회논문집
    • /
    • 제23권3호
    • /
    • pp.274-281
    • /
    • 2013
  • Field measurement method of heavy/soft impact sound pressure level which is regulated in JIS and ISO has been using in Korea, Japan and Canada. It is reported that heavy/soft impact sound pressure level was varied by the sound field condition of receiving room such as sound absorption power and room volume. In this study, it is checked that heavy/soft impact sound pressure level was affected by the receiving sound field condition. Rubber ball and bang machine sound pressure level was measured in the vertically connected reverberation chamber. In oder to check the effect of receiving sound field on heavy/soft impact sound pressure, sound absorption power was changed with polyester sound absorption blankets with air space and glass wool. The reverberation time at 1 kHz band was changed from 10 s to 0.2 s by sound absorption material. Rubber ball sound pressure level measured without sound absorption material was 58 dB in $L_{i,Fmax,AW}$, but the level was 46 dB with sound absorption treatment. From this result, it is confirmed that sound field correction method is needed in the heavy/soft impact sound pressure level measurement method using bang machine and rubber ball.

소리의 특성 및 청지각기능에 대한 고찰 (A Study on the Nature of Sound and the Hearing Mechanism)

  • 이정학;김진숙
    • 음성과학
    • /
    • 제5권1호
    • /
    • pp.167-179
    • /
    • 1999
  • The hearing mechanism is a complicated system. Sound is generated by a source that sends out air pressure or power. The pressure or power makes the sound waves. These waves reach the eardrum, or tympanic membrane, which vibrates at a rate and magnitude proportional to the nature of the sound waves. The tympanic membrane transforms this vibration into the mechanical energy in the middle ear, which in turn converts it to the hydraulic energy in the fluid of the inner ear. The hydraulic energy stimulates the sensory cells of the inner ear which send neuroelectrical impulses to the central auditory nervous system. The passive perception of auditory information starts just here. The listener gives attention to the speech sound, differentiates the sound from background noise, and integrates his experience with similar sounds. The listener then puts all of these aspects of audition into the context of the moment to identify the nature of sound. This has a major role in human communication. This paper provides an overview of the nature and characteristics of sound, the structure and function of the auditory system, and the way in which sound is processed by the auditory system.

  • PDF

옵셋 인쇄기계 동력규모 변화에 따른 소음 영향 평가 (The Noise Influence Assessment according to the Change of the Offset Type Print Machine's Power)

  • 구진회;권명희;이우석;이재원;박형규;김삼수;윤희경;이규목;정대관;서충열
    • 한국소음진동공학회논문집
    • /
    • 제24권9호
    • /
    • pp.682-686
    • /
    • 2014
  • Nowadays, the needs to revise the classification criteria for noise emission facilities have been suggested by the related industries. Because there existed many reasonable factors in the criteria regarding the noise emission facilities. And the noise emission facility classification criterion of the print machine changed from 50 HP to 100 HP in 2013. But the increasement of the noise emission facility classification criterion of the print machine can cause adverse effects like the bigger noise. So, in this paper, we measured the print machine's sound power level according to the changes of the print machine's power to assess the adverse effects. The measurement method applied with KS I ISO 9614-2(1996). The corelation between the sound power level and the power of print machines was analyzed by regression analysis. In this paper, we found that the sound power level of the print machines can increase about 1.3 dB in the condition of that the power of print machine increases from 50 HP to 100 HP. And we found that the sound power level of the print machines can increase about 1.0 dB for a increasement of 1,000 SPH(sheet per hour) of printing speed. The noise emission characteristics of print machine stuied in this paper will be useful to design the noise reduction plan in the future.

전력용 변압기 차음실 개발 (Development of the Soundproof Enclosure for Power Transformers)

  • 권동진;구교선;이욱륜
    • 조명전기설비학회논문지
    • /
    • 제23권10호
    • /
    • pp.107-114
    • /
    • 2009
  • 전력수요의 증가 및 도심지역의 확대로 도심지내 변전소에 전력용 변압기의 설치가 필요하나, 변전소의 전력용 변압기에서 발생하는 소음으로 인한 민원이 증가하고 있다. 따라서 전력용 변압기에서 발생하는 소음의 전파를 차단하기 위하여, 옥외 변전소의 전력용 변압기에는 방음벽을 적용하여 왔으며, 옥내 변전소에는 방음문, 방음 셔터 및 풍도형 방음장치 등을 적용하여 왔다. 그러나 이러한 방법에 의한 소음저감 효과는 만족할 정도에 이르지 못하는 실정이다. 본 연구에서는 전력용 변압기로부터 발생되는 소음을 효과적으로 차단하기 위해 변압기 차음실을 개발하였다. 개발한 변압기 차음실은 154[kV] 변압기에 적용하여 120[Hz] 성분에서 15[dB]의 소음저감 효과를 확인하였다.

화재비상경보음의 건물 내 전달특성에 관한 연구 (A Study on the Propagation Characteristics of Fire Alarm Sound in Buildings)

  • 백은선
    • 한국화재소방학회논문지
    • /
    • 제23권5호
    • /
    • pp.153-160
    • /
    • 2009
  • 본 연구에서는 건축 실내음향 특성파악에 이용되는 컴퓨터 시뮬레이션을 통해 비상경보설비의 음향장치에 공급되는 전압의 변동에 따른 비상경보설비음의 전달특성을 파악하였다. 현재 가장 널리 사용되고 있는 비상경보설비의 음향장치 음향파워레벨(정격전압 DC 24V)은 경종은 98.6dB, 전자식사이렌 스피커는 95.7dB 그리고 전자식사이렌 폰은 101.8dB로 측정되었다. 또한 경종은 주파수 증가에 따라 음항파워레벨이 증가하고 고주파 대역에서 피크 레벨을 보이는데 반해 전자사이렌의 폰형과 스피커형은 135~200Hz에서 최저음향파워레벨을 보이다가 이후 급격히 증가하는 패턴을 나타냈다. 컴퓨터 시뮬레이션을 통하여 비상경보설비와의 이격거리에 따른 전달특성을 살펴보면, 대상건물의 복도에서는 전체적으로 고른 분포를 보여주고 있다. 하지만 인접해 있는 강의실에서는 벽체 부분을 제외한 우회전달음의 영향으로 비상경보설비 음향장치의 주파수 특성에 따라 전달되는 음압레벨의 차가 크게 발생하였다. 향후 예측수법의 정확도와 타당성 검토을 통한 화재비상경보음의 전달특성을 건축물의 계획 시에 예측 비교한다면 화재 경보의 인지 가능성을 높일 수 있을 것으로 사료된다.