Abstract
Field measurement method of heavy/soft impact sound pressure level which is regulated in JIS and ISO has been using in Korea, Japan and Canada. It is reported that heavy/soft impact sound pressure level was varied by the sound field condition of receiving room such as sound absorption power and room volume. In this study, it is checked that heavy/soft impact sound pressure level was affected by the receiving sound field condition. Rubber ball and bang machine sound pressure level was measured in the vertically connected reverberation chamber. In oder to check the effect of receiving sound field on heavy/soft impact sound pressure, sound absorption power was changed with polyester sound absorption blankets with air space and glass wool. The reverberation time at 1 kHz band was changed from 10 s to 0.2 s by sound absorption material. Rubber ball sound pressure level measured without sound absorption material was 58 dB in $L_{i,Fmax,AW}$, but the level was 46 dB with sound absorption treatment. From this result, it is confirmed that sound field correction method is needed in the heavy/soft impact sound pressure level measurement method using bang machine and rubber ball.
Keywords
Sound Field; Floor Impact Sound; Reverberation Time; Room Volume; Correction Method; Heavy/soft Impact Source;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Jeong, J. H. and Jeon, J. Y., 2005, Floor Impact Noise Measurement and Evaluation Method Using Impact Ball, Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 15, No. 10, pp. 1160-1168.   과학기술학회마을   DOI   ScienceOn
2 Son, C. B., Kim, J. S. and Kim, S. W., 1991, A Study on the Sound Distribution of Floor Impact Sound for Apartment house, Journal of the Architectural Institute of Korea, Vol. 7. No. 4, pp. 135-147.
3 Park, H. K. and Kim, S. W., 2009, Comparison and Analysis of Measurement of Floor Impact Sound in Apartment with Balcony Remodeling, Journal of the Architectural Institute of Korea, Vol. 25. No. 8. pp. 329-336.
4 Lee, S. W., 2004, Impact Sound Characteristics of Floors According to the Number of P'yong and Layers, Journal of Korea Institute of Ecological Architecture and Environment, Vol. 4. No. 3, pp. 71-78.
5 Joo, M. K., Park, J. Y., Yang, K. S. and Oh, Y. K., 2008, A Study on the Measurement Method of Improvement of Reliability for Heavy-weight Floor Impact Sound Measurement, Journal of the Acoustical Society of Korea, Vol. 27, No. 4, pp. 163-170.   과학기술학회마을
6 Lee, S. Y., Yoo, S. Y. and Jeon, J. Y., 2007, Investigation of Receiving Position in the Measurement Method for Floor Impact Sound in a Testing Building, Proceedings of the KSNVE Annual Spring Conference, pp. 694-968.
7 Oh, Y. K. and Joo, M. K., 2012, Problems in the Accreditation of Floor Impact Noise Insulation Performance, Proceedings of Korean Institute of Architectural Sustainable Environment and Building Systems Autumn Conference, pp. 71-74.
8 Stefan S., Berndt Z. and Trevor N., 2010, Influence of Receive Room Properties on Impact Sound Pressure Level Measured with Heavy Impact Sources, 1st EAA - EuroRegio 2010.
9 ISO 10140-5: 2010, Acoustics - Laboratory Measurement of Sound Insulation of Building Elements - Part 5: Requirements for Test Facilities and Equipment
10 ISO/CD 16283-2 Acoustics - Field Measurement of Sound Insulation in Buildings and of Building Elements - Part 2: Impact Sound Insulation.
11 ISO 16032 Acoustics - Measurement of Sound Pressure Level from Service Equipment in Buildings - Engineering Method.
12 Jeon, J. Y., Lee, P. J., Jeong, J. H. and Park, J. H., 2006, Comparisons of Standard Floor Impact Sources with a Hammer Impact Sources, Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 16, No. 8, pp. 789-796.   DOI   ScienceOn