Acoustical Estimation of Zooplankton Distributions From the Backscattered Signal of the Acoustic Doppler Current Profiler in the Korea Strait (한국 해협에서 ADCP(Acoustic Doppler Current Profiler)의 음파 산란신호에 의한 동물플랑크톤 분포의 추정)

  • Na, Jung Yul;Park, Joung Soo
    • 한국해양학회지
    • /
    • 제24권4호
    • /
    • pp.172-183
    • /
    • 1989
  • Acoustical estimation of vertical distributions of zooplankton was carried out by using the backscattered signals of ADCP which was deployed in the Korea Strait in September, 1978. the backscattered signals of ADCP represents the total backward sound intensity caused by the scatters existing within the insonified water column of 8m deep. Based on these backscattered intensities, the estimated number of individual zooplankton (namely, Copepods) varies with depth such that in the surface layer above the thermocline, the numbers are exceedingly larger than the lower layer. It is also shown that a relatively larger number of individuals exists in the bottom cold water layer in the centeral part of the Strait. The horizontal distribution of the zooplankton in the surface layer across the west channel of the Strait shows that the number is higher in the coastal zone of the Korea and it decreases toward the central and then remains constant up to the vicinity of the Tsushima Island where it increases again. This type of distributions is well fitted to the one obtained at several stations by the conventional method at least in qualitative way. Therefore, it is quite plausible to use the ADCP data for monitoring the spatial and temporal distributions of zooplankton.

  • PDF

Clinical efficacy of 0.75% ropivacaine vs. 2% lignocaine hydrochloride with adrenaline (1:80,000) in patients undergoing removal of bilateral maxillary third molars: a randomized controlled trial

  • Kakade, Aniket Narayan;Joshi, Sanjay S.;Naik, Charudatta Shridhar;Mhatre, Bhupendra Vilas;Ansari, Arsalan
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제21권5호
    • /
    • pp.451-459
    • /
    • 2021
  • Background: Lignocaine with adrenaline is routinely used as a local anesthetic for dental procedures. Adrenaline was added to increase the duration of anesthesia. However, epinephrine containing a local anesthetic solution is not recommended in conditions such as advanced cardiovascular diseases and hyperthyroidism. Recently, ropivacaine has gained popularity as a long-acting anesthetic with superior outcomes. The goal of this study was to assess and compare the effectiveness of 0.75% ropivacaine alone and 2% lignocaine with adrenaline (1:80,000) in the removal of bilateral maxillary wisdom teeth using the posterior superior alveolar nerve block technique. Methods: This was a single-blind, randomized, split-mouth, prospective study assessing 15 systemically sound outpatients who needed bilateral removal of maxillary third molars. We randomly allocated the sides and sequences of ropivacaine and lignocaine with adrenaline administration. We evaluated the efficacy of both anesthetics with regard to the onset of anesthesia, intensity of pain, variation in heart rate, and blood pressure. Results: The onset of anesthesia was faster with lignocaine (138 s) than with ropivacaine (168 s), with insignificant differences (p = 0.001). There was no need for additional local anesthetics in the ropivacaine group, while in the lignocaine with adrenaline group, 2 (13.3%) patients required additional anesthesia. Adequate intraoperative anesthesia was provided by ropivacaine and lignocaine solutions. No significant difference was observed in the perioperative variation in blood pressure and heart rate. Conclusion: Ropivacaine (0.75%) is a safe and an adrenaline-free local anesthetic option for posterior superior alveolar nerve block, which provides adequate intraoperative anesthesia and a stable hemodynamic profile for the removal of the maxillary third molar.

Ocean bottom reverberation and its statistical characteristics in the East Sea (동해 해역에서 해저면 잔향음 및 통계적 특징)

  • Jung, Young-Cheol;Lee, Keun-Hwa;Seong, Woojae;Kim, Seongil
    • The Journal of the Acoustical Society of Korea
    • /
    • 제38권1호
    • /
    • pp.82-95
    • /
    • 2019
  • In this study, we analyzed the beam time series of ocean reverberation which was conducted in the eastsouthern region of East Sea, Korea during the August, 2015. The reverberation data was gathered by moving research vessel towing LFM (Linear Frequency Modulation) source and triplet receiver array. After signal processing, we analyzed the variation of ocean reverberation level according to the seafloor bathymetry, source/receiver depth and sound speed profile. In addition, we used the normalized data by using cell averaging algorithm and identified the statistical characteristics of seafloor scatterer by using moment estimation method and estimated shape parameter. Also, we analyzed the coincidence of data with Rayleigh and K-distribution probability by Kolmogorov-Smirnov test. The results show that there is range dependency of reverberation according to the bathymetry and also that the time delay and the intensity level change depend on the depths of source and receiver. In addition, we observed that statistical characteristics of similar Rayleigh probability distribution in the ocean reverberation.

Optimization of Ingot Mold Design Parameters for Austenite Heat-resistant Steel Through Computational Simulation (전산모사를 통한 오스테나이트계 내열강용 잉곳 몰드 설계 파라미터 최적화)

  • Hwang, SooBeen;Park, JongHwa;Jo, SangHyun;Park, SeongIk;Kim, YunJae;Kim, Donggyu
    • Journal of Korea Foundry Society
    • /
    • 제42권1호
    • /
    • pp.3-11
    • /
    • 2022
  • In this study, the parameters on the shrinkage defect of HR3C alloy was secured through computer simulation research, and the ingot mold with greater than 85% of sound area was designed and manufactured. Moreover, the optimized coagulation was proposed at design stage through computer simulation and test was performed upon ingot manufactured. After the test, the defect pattern was analyzed through cutting and non-destructive inspection to verify the parameter and ingot mold design. Based on the verification results, shrinkage defect parameters such as Niyama, Feed Efficiency, and Hot Tear Intensity of HR3C Alloys were obtained. In addition, through the secured parameters, a plan for designing ingot mold with a Non-defect area of 85% or more was secured.

The Effect of Internal Control Weaknesses on Book-Tax Difference (내부회계관리제도의 취약점이 회계이익과 과세소득의 차이에 미치는 영향)

  • Yu, Soon-Mi;Park, Sang-Bong
    • Management & Information Systems Review
    • /
    • 제30권3호
    • /
    • pp.169-190
    • /
    • 2011
  • Recent academic studies have investigated book-tax differences as an indicator of earnings management. Tax accounting texts claim that the differences between pre-tax financial reporting earnings and taxable income can provide information about current earnings, and the large differences between book and taxable incomes are an indicator of low-quality financial reporting earnings. This study investigates the effect of internal control system over book and tax difference using the KOSPI and KOSDAQ firms from 2006 to 2008. The empirical findings are consistent with a weakness of internal control system being associated with higher book-tax difference. That means a firm which has material weakness in the internal control system allows for more malpractice. In addition to this, If the managers tries to the efficient tax decrease strategy, book-tax difference can be large. Which in turn leads us to observe a positive relation between the weakness of internal control system and intensity of book-tax difference. Overall, we interpret this evidence as indicating that the failure of the internal control system can effect not only investors and creditors but also tax authorities. And It emphasizes that a more effective internal control system linked with sound corporate governance.

  • PDF

An Experimental Study on Improvement of the Effect for Runoff Reducing Facilities Using Infiltration (침투형 우수유출 저감시설의 저감효과 개선에 관한 실험 연구 : 누가침투량 분석에 의한 침투-저류시스템 제안)

  • Im, Janghyuk;Song, Jaiwoo;Park, Youngjin
    • Journal of the Korean GEO-environmental Society
    • /
    • 제10권4호
    • /
    • pp.5-13
    • /
    • 2009
  • The runoff-reducing facilities using infiltration was considered for the sustainable and sound water management. However, for practical utilization, many problems are attended and therefore effort on improvements are required. In this study, methods of improvement for infiltration facilities proposed by Infiltration-Storage System (ISS) and the effect of runoff reduction were analyzed by hydraulic experimental study. In order to analyze the infiltration characteristics of proposed runoff reduction facilities in this study, it was applied to various rainfall condition and surface material considering development and urbanization influences. As a results of hydraulic model experiment, Infiltration-Storage System (ISS) made addition to effect of reduction by lower layer of accumulative infiltration quantities. And then as rainfall-intensity was increased, accumulative infiltration rates were increased in this study. Thus, Infiltration-Storage system (ISS) was more efficient than existing runoff reduction facilities because of increasing infiltration rate. Such a result was guaranteed application of ISS as runoff-reducing facilities. Therefore, ISS is expected to be capable for practical application if subsequent research for improvements are followed. Additionally, results of this study are expected to provide fundamental research data on infiltration facilities.

  • PDF

A Study on The Multi-point Signal and It's Directivity detection of FBG Hydrophone Using Hopper WDM be in The Making (Hopper WDM을 이용한 FBG(Fiber Bragg Grating) 하이드로폰(Hydrophone)의 다중점신호검출 및 지향성 연구)

  • Kim, Kyung Bok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • 제52권11호
    • /
    • pp.156-163
    • /
    • 2015
  • In the using of FBG(Fiber Bragg Grating) developed in home land, we designed and manufactured united FBG acoustic transducers the first in Korea. they are being applied to multi-point signal detection of FBG Hydrophone used Hopper WDM(national patent NO 10-1502954) in the underwater. On united FBG transducers manufactured, we made an demonstrated on respective frequency response peculiarities in the underwater and analyzed the special characters. As the experimental result on frequency response peculiarities, we made it possible underwater acoustic detection on united FBG acoustic transducers type to maximum 30Hz~2.5KHz. it's the optimum conditions of 1.2KHz frequency in detection. And for the purpose of realization on multi-point signal detection on wide scope in the underwater, in the using of WDM(Wavelength Division Multiplexing) method and passive band-pass filter system, established arrays system and succeeded in multi-point underwater acoustic signal detection to the frequency 200Hz~1.3KHz out of the two united type FBG transducers. Additionally, it would be possible directivity detection for the object of its source as the intensity of detection signal varies with the sound source's direction and angle. From now on we prepared a new moment on the practical use study on FBG hydrophone in the future.

N100 Amplitude Slopes in Major Depressive Disorder, Bipolar Disorder, Schizophrenia and Normal Controls (주요 우울 장애, 정신분열병, 양극성 장애 및 정상 대조군에서의 N100 진폭경사)

  • Yang, Eunkyoung;Lee, Seung-Hwan;Oh, Sunghee;Kim, Sangrae
    • Korean Journal of Biological Psychiatry
    • /
    • 제16권3호
    • /
    • pp.181-189
    • /
    • 2009
  • Objectives : N100 amplitude slope(the intensity dependence of the cortical auditory evoked potentials) is widely considered as an indirect indicator of central serotonergic neurotransmission. However, there are only a few studies about N100 amplitude slopes of major psychiatric disorders. In this study, we examined N100 amplitude slope differences among major depressive disorder(MDD), bipolar disorder(BD), schizophrenia (SCZ) and normal controls(NC). Methods : We measured the N100 amplitude slopes of 35 patients with MDD, 33 patients with BD, 27 patients with SCZ and 35 NC subjects. Amplitude differences from N1 to P2 at the five different sound intensities(55, 65, 75, 85 and 95dB) were examined at Cz electrode. The N100 amplitude slope was calculated as the linear regression of five N1/P2 peak-to-peak amplitudes across stimulus intensities. Results : BD patients showed significantly reduced N100 amplitude slope compared with NC(0.54${\pm}$0.70 vs. 0.96${\pm}$0.72, p=0.035). N100 amplitude slope of SCZ patients was significantly reduced compared with NC(0.50${\pm}$0.47 vs. 0.96${\pm}$0.72, p=0.027). N100 amplitude slope of BD patients was significantly lower than that of MDD patients(0.54${\pm}$0.70 vs. 0.94${\pm}$0.60, p=0.046). SCZ patients also showed significant reduction of N100 amplitude slope compared with MDD patients(0.50${\pm}$0.47 vs. 0.94${\pm}$0.60, p=0.036). There was no significant difference of N100 amplitude slope between MDD patients and NC(0.94${\pm}$0.60 vs. 0.96${\pm}$0.72, p=1.000). Conclusion : Interestingly, the N100 amplitude slopes of BD and SCZ were reduced compared to NC and MDD patients. Our results suggest the predictive use of N100 amplitude slope in making differential diagnoses of major psychiatric disorders. Clinical implications of N100 amplitude slope in major psychiatric disorders were discussed.

  • PDF

Flow Visualization of Acoustic Streaming Induced by Ultrasonic Vibration Using Particle Imaging Velocimetry (PIV를 이용한 초음파 진동에 의해 유도된 음향유동의 가시화)

  • 노병국;권기정;이장연;이동렬
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • 제14권6호
    • /
    • pp.528-535
    • /
    • 2004
  • Ultrasonic Vibrator is designed to achieve the maximum vibration amplitude at 30 kHz by in-cluding a horn (diameter, 40 mm), mechanical vibration amplifier at the top of the ultrasonic vibrator in the system and making the complete system resonate. In addition, it is experimentally visualized by particle imaging velocimetry (PIV) that the acoustic streaming velocity in the gap is at maximum when the gap between the ultrasonic vibrator and stationary plate agrees with the multiples of half-wavelength of the ultrasonic wave. This fact results from the resonance of the sound wave and the theoretical analysis of that is also accomplished and verified by experiment. It is observed that the magnitude of the acoustic streaming dependent upon the gap between the ultrasonic vibrator and stationary plate possibly changes due to the measurement of the average velocity fields of the acoustic streaming induced by the ultrasonic vibration at resonance and non-resonance. There exists extremely small average velocity at non-resonant gaps while the relatively large average velocity exists at resonant gaps compared with non-resonant gaps. It also reveals that there should be larger axial turbulent intensity at the hub region of the vibrator and at the edge of it in the resonant gap where the air streaming velocity is maximized and the flow phenomena is conspicuous than that at the other region. Because the variation of the acoustic streaming velocity at resonant gap is more distinctive than that at non-resonant gap, shear stress increases more in the resonant gap and is also maximized at the center region of the vibrator except the local position of center (r〓0). At the non-resonant gap there should be low values of vorticity distribution, but in contrast to the non-resonant gap, high and negative values of it exist at the center region of the vibrator with respect to the radial direction and in the vicinity of the middle region with respect to the axial direction. Acoustic streaming is noise-free due to the ultrasonic vibration and maintenance-free because of the absence of moving parts. Moreover, the proposed method by acoustic streaming can be utilized to the nano and micro-electro mechanical systems as a driving mechanism in addition to the augmentation of the streaming velocity.

Extraction of Muscle Areas from Ultrasonographic Images using Information of Fascia (근막 정보를 이용한 초음파 영상에서의 근육 영역 추출)

  • Kim, Kwang-Baek
    • Journal of Korea Multimedia Society
    • /
    • 제11권9호
    • /
    • pp.1296-1301
    • /
    • 2008
  • Ultrasonography constructs pictures of areas inside the body needs in diagnosis by bouncing high-enorgy sound waves(ultrasound) off internal tissues or organs. In constructing an ultrasonographic image, the weakness of bounding signals induces noises and detailed differences of brightness, so that having a difficulty in detecting and diagnosing with the naked eyes in the analysis of ultrasonogram. Especially, the difficulty is extended when diagnosing muscle areas by using ultrasonographic images in the musculoskeletal test. In this paper, we propose a novel image processing method that computationally extracts a muscle area from an ultrasonographic image to assist in diagnosis. An ultrasonographic image consists of areas corresponding to various tissues and internal organs. The proposed method, based on features of intensity distribution, morphology and size of each area, extracts areas of the fascia, the subcutaneous fat and other internal organs, and then extracts a muscle area enclosed by areas of the fascia. In the extraction of areas of the fascia, a series of image processing methods such as histogram stretching, multiple operation, binarization and area connection by labeling is applied. A muscle area is extracted by using features on relative position and morphology of areas for the fascia and muscle areas. The performance evaluation using real ultrasonographic images and specialists' analysis show that the proposed method is able to extract target areas being approximate to real muscle areas.

  • PDF