• Title/Summary/Keyword: Sound control

Search Result 1,193, Processing Time 0.029 seconds

Variation of the Sound Insulation Performance of Window in the Apartment House depending on the Sound Source Characteristics (공동주택에서 음원특성에 따른 외부창호 차음성능 변화)

  • Park, Hyeon-Ku;Lee, Ok-Kyun;Han, Dong-Hwa;Song, Hyuk;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1735-1740
    • /
    • 2000
  • The aim of this study is to analyze the sound insulation performance of windows depending on the sound source types and to propose the noise control method in the apartment house. The regions where apartment houses are constructed are varied in the dominant noise sources such as aircraft noise, railway noise and road traffic noise. For the experiment, nine noise sources including pink noise were selected and recorded, which was used in the experiment by reproducing. As a result of this study, the sound insulation performance of window was found that when the frequency contents of the noise were high level in all frequency bands the difference of sound insulation performance was negligible, but when the frequency contents were low level at particular frequency band the difference of sound insulation performance was shown very differently.

  • PDF

Sound Quality Improvement of Electric Parking Brake System (EPB(Electric Parking Brake) 작동음질 개선에 관한 연구)

  • Park, Dong-Chul;Hong, Seok-Kwan;Jo, Ki-Chang
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.461-466
    • /
    • 2012
  • Customers want to have more convenient and comfortable vehicle. Motor-on-caliper EPB(Electrical Parking Brake) System is one of the new systems for customer's convenience. It is applied for Midsize vehicle for reducing weight/price compared to cable puller type EPB. In this paper we studied sound quality improvement of motor-on-caliper EPB system. We developed the sound quality index and suggested the interior sound quality target value. To meet the target value cascading target was also suggested. EPB motor vibration level & sound radiation level, vibro-acoustic transfer function level from EPB to interior was defined. To find out effective way of sound quality improvement and find cascading target, TPA(Transfer Path Analysis) was carried out.

  • PDF

A Study on Prediction of vibration and Sound Radiation by Plate With Four Edges Clamped (네 변이 고정된 평판의 진동 및 방사 소음 예측에 관한 연구)

  • 심현진;이정윤;오재응
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.743-747
    • /
    • 2003
  • In recent years, several studies of the practical application of active sound and vibration control have been developed to plate to plate response with various boundary conditions. This study considers vibration and sound radiation for the clamped rectangular plate. The radiation of a sound from rectangular plate can be calculated that the velocity of a vibrating plate is analyzed. The vibration formulation is based on a variation method for the vibration of the plate, and assumes no damping, no fluid loading of the structure. And the plate is exited by harmonic point force. The radiation of sound from plate is analyzed in the far field, and is calculated from the Rayleigh integral. The prediction results of vibration and sound level have proved with FEM or BEM.

  • PDF

Evaluation of Sound Quality of Air-conditioning Noise (에어컨 소음의 Sound Quality 평가)

  • Jeon, Jin-Yong;You, Jin;Kim, Su-Yeon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.5 s.110
    • /
    • pp.551-558
    • /
    • 2006
  • Noise from air-conditioner system installed in the ceiling of a classroom was evaluated to investigate the sound quality of air-conditioning noise. Harmonics of air-conditioning noise were removed and the sound pressure levels of the frequency bands from $250{\sim}630Hz$ were changed to control sound quality. Evaluation for refreshing sensation was conducted using a paired comparison method and the results showed that noise without harmonics were preferred to noise with harmonics. The noises which have larger level increases to the unchanged noise at $250{\sim}630Hz$ were evaluated better in both of the noises with and without harmonics. Results of multiple regression analysis on psychoacoustic parameters and subjective preferences showed sharpness as a major affecting factor in describing the refreshing aspect of air-conditioning sound.

A study on the Beehive Door Opening and Closing System using a Hornet Sound Analysis

  • Kim, Joon Ho;Han, Wook;Chung, Wonki
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.393-396
    • /
    • 2022
  • Recently, rapid climate change has had a significant impact on the ecosystem of honeybees. In addition, the problem of Vespa Hornets invasion of colonies has a fatal impact on the bee ecosystem, independent of climate change. Especially in late summer. This study relates to a method for preventing Vespa Hornets attack. In this study, we developed a Vespa Hornets sound detection device was developed by collecting and analyzing the sound of a Vespa Hornets and applying IoT technology. The developed device detects the sound of a Vespa Hornets when Vespa Hornets appears around the hive of the bees and sends a signal to automatically close the door of the beehive. The device that receives the signal drives the motor that controls the honeycomb door to close the beehive door. The Vespa Hornets sound detection device operates until no Vespa Hornets sound is detected. The system developed by us is expected to be installed in the beehives of actual beekeeping farms to dramatically reduce the damage caused by by Vespa Hornets.

Effect of Heat Treatment on the Gas Permeability, Sound Absorption Coefficient, and Sound Transmission Loss of Paulownia tomentosa Wood (참오동나무의 열처리가 기체투과성, 흡음율과 음향투과손실에 미치는 영향)

  • KANG, Chun-Won;JANG, Eun-Suk;JANG, Sang-Sik;Cho, Jae-Ik;KIM, Nam-Hun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.47 no.5
    • /
    • pp.644-654
    • /
    • 2019
  • In this study, the gas permeability, sound absorption coefficient, and sound transmission loss of the Paulownia tomentosa wood were estimated using capillary flow porometry, transfer function method, and transfer matrix method, respectively. The longitudinal specific permeability constant of the Paulownia tomentosa wood with a thickness of 20 mm was 0.254 for the control sample and 0.279, 0.314, and 0.452 after being subjected to heat treatments at $100^{\circ}C$, $160^{\circ}C$, and $200^{\circ}C$, respectively. The gas permeability was observed to be slightly increased by the heat treatment. The mean sound absorption coefficients of 20-mm thick Paulownia tomentosa log cross-section for the control sample and after being subjected to heat treatments at $100^{\circ}C$, $160^{\circ}C$, and $200^{\circ}C$ were 0.101, 0.109, 0.096 and 0.106, respectively. Further, the noise reduction coefficients of 20-mm thick Paulownia tomentosa log cross-section of the control sample and after being subjected to heat treatment at temperatures of $100^{\circ}C$, $160^{\circ}C$, and $200^{\circ}C$ were 0.060, 0.067, 0.062 and 0.071, respectively. The mean of sound transmission loss of the 20-mm thick Paulownia tomentosa log cross-section was approximately 36.93 dB. Furthermore, the gas permeability and sound absorption coefficient of the heat-treated Paulownia tomentosa discs slightly increased depending on the heat treatment temperature; however, the rate of increase was insignificant.

A Helmholtz Resonator Array Panel for Low Frequency Sound Absorption (저주파수 흡음을 위한 헬름홀쯔 공명기 배열형 패널)

  • Kim, Yang-Hann;Kim, SangRyul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.8 s.101
    • /
    • pp.924-930
    • /
    • 2005
  • Sound absorptive materials have good performance in high frequency range, not at low frequencies. Therefore it has been great challenge to develop a sound absorbing structure that is good at low frequency. We propose to use a Helmholtz resonator array panel for this purpose. A Helmholtz resonator is one of noise control elements widely used in many practical applications. The resonator is a simple structure composed of a rigid-walled cavity with a neck, but it has very high performance at resonance frequency. This paper discusses the sound absorption of Helmholtz resonator array panels at normal and random incidence. First, various experimental results are introduced and studied. Secondly, we theoretically predict the absorptive characteristics of the resonator away panel. The theoretical approach is based on the Fourier analysis for a periodic absorber. We believe that this method can be used to design a panel for low frequency noise control.

A Separator system for underwater observing instrument (수중 관측 및 탐사장비 원격분리 시스템의 개발)

  • Kim, Young-Jin;Jeong, Han-Cheol;Huh, Kyung-Moo;Cho, Young-June
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.158-160
    • /
    • 2005
  • In order to successfully exploit underwater resources, the first step would be a marine environmental research and exploration on the seafloor. Traditionally one sets up a long-term underwater experimental unit on the seafloor and retrieves the unit later after a certain period time. Essential to these applications is the reliable teleoperation and telemetering of the unit. In our proposed ultrasonic-wave remote control system and an underwater sound recognition algorithm that can identify the sound signal without the influence of disturbances due to underwater environmental changes. The proposed method provides a means suitable for units which require low power dissipation and long-time underwater operation. We demonstrate its ability of securing stability and fast sound recognition through experimental methods.

  • PDF

A Study on the Sound Insulation Performance of Steel-Structured Apartment Buildings (I) (철골조 공동주택의 차음성능 실태조사에 관한 연구 (I))

  • Cha, Sang-Gon;Lee, Sang-Woo;Jung, Byung-Wook;Jeong, Dae-Up;Lee, Soo-Yeul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.151-156
    • /
    • 2000
  • The sound insulation performance of walls and floors for air-borne and structure-borne sounds in an apartment building is an important environmental factor which should be contemplated at the intial design stage for their thorough control. Recent increasing residents' demands for quality living spaces strongly urge the development of more accurate and efficient measurement and evaluation methods for the control of air-borne and structure-borne sound insulation. However, steel-structured apartment buildings, recently emerged as new building structures in the market, have not been thoroughly examined. The present work carried out an extensive survey for steel-structured apartment buildings, in an attempt to provide useful design data, and their sound insulation performances were compared with those of R.C. apartment buildings.

  • PDF

Active Control of Honeycomb Trim Panels for Aircrafts (항공기용 하니콤 트림판넬의 능동제어)

  • Elliott Stephan J.;Jeong, W.B.;Hong, Chin-Suk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.464-473
    • /
    • 2006
  • This paper summarises theoretical and experimental work on the feedback control of sound radiation from honeycomb panels using piezoceramic actuators. It is motivated by the problem of sound transmission in aircraft, specifically the active control of trim panels. Trim panels are generally honeycomb structures designed to meet the design requirement of low weight and high stiffness. They are resiliently-mounted to the fuselage for the passive reduction of noise transmission. Local coupling of the closely-spaced sensor and actuator was observed experimentally and modelled using a single degree of freedom system. The effect of the local coupling was to roll-off the response between the actuator and sensor at high frequencies, so that a feedback control system can have high gain margins. Unfortunately, only relatively poor global performance is then achieved because of localisation of reduction around the actuator. This localisation prompts the investigation of a multichannel active control system. Globalised reduction was predicted using a model of 12 channel direct velocity feedback control. The multichannel system, however, does not appear to yield a significant improvement in the performance because of decreased gain margin.

  • PDF