• Title/Summary/Keyword: Sound Temperature Level

Search Result 53, Processing Time 0.026 seconds

A Comparative Study on the Characteristics of Thermoacoustic Laser for Using Solar Energy (태양에너지 이용을 위한 열음향 레이저의 특성 비교 연구)

  • Park, Sung-Seek;An, Eoung-Jin;Oh, Seung-Jin;Chun, Won-Gee;Kim, Nam-Jin
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.516-521
    • /
    • 2012
  • The conversion of solar energy into acoustic waves is experimentally studied. Measurements were made on the Sound Pressure Level (SPL), frequency, onset time and the temperature gradient across the stack. A pyrex resonance tube is used with a honey-comb structure ceramic stack along with Ni-Cr and Cu wires. An AL1 acoustical analyzer was used to measure the SPL and frequency of acoustic waves whereas K-type thermocouples were hired to estimate temperature gradients. For a resonance tube of 100mm, no acoustic waves were generated with a power input of 25W. By increasing its length to 200mm, however, maximum SPLs of 96.4 dB, 106.3 dB and 112.8 dB were detected for the tubes of 10mm, 20mm and 30mm in IDs and their respective stack positions of 70mm, 60mm and 50mm from the closed end.

  • PDF

A Comparative Study on the Characteristics of Thermoacoustic Waves by the Stack Channel Number (스택의 채널 수에 다른 열음향파의 특성 비교 연구)

  • Park, Sung-Seek;Cheon, Won-Gi;Kim, Nam-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.8-14
    • /
    • 2013
  • The conversion of solar energy into acoustic waves is experimentally studied. Measurements were made on the Sound Pressure Level(SPL), onset time and the temperature gradient across the stack, with the Cell Per Square Inch(CPSI) of stack changed. A pyrex resonance tube is used with a honey-comb structure ceramic stack along with Ni-Cr and Cu wires. An AL1 acoustical analyzer was used to measure the SPL and frequency of acoustic waves whereas K-type thermocouples were hired to estimate temperature gradients. As a result, when the supply electric power was 25W, maximum SPLs of 104.1 dB, 109.4 dB and 112.8 dB were detected for the stacks of 200, 300 and 400 CPSI and their respective stack positions of 70mm, 60mm and 50mm from the closed end.

Development of a remote monitoring system for gas detection at the subway station (지하철 역내 가스 검출 원격 모니터링 시스템 구현)

  • Park, Yong-Man;Kim, Hei-Sik;Kim, Gyu-Sik;Lee, Moon-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.439-441
    • /
    • 2007
  • The seoul metropolitan subway has installed 8 lines and about 500 stations to transport 5 million passengers everyday. The underground air pollution level in the subway stations is very severe status, which is very harmful to the commutators and its personals. Although subway roles as such a massive and huge transportation system, the subway doesn't adapt yet any real-time air monitoring system. They have only some hand-held type detector equipments for monitoring air pollution. Therefore subway passengers are exposed to the harmful air pollution environment. The most harmful environmental parameters among the air pollution are known as the dust and sound noise dB level in the subway station. Because the dust is consisted of very small particles, we can't see them easily in dark condition on the platform, but it is very harmful. The monitoring system for air pollution is developed using embedded system attached with 6 different environmental sensors. This system monitors air pollution of dust sound noise, gas, temperature, humidity, inflammable gas, toxic gas in the subway ?station. The sensor unit of the ARM-CPU board and sensor transmits real time environmental data to the main server using Zigbee wireless communication module and TCP/IP network. The main control server receives and displays the real-time environmental data, and it send alarms to the personals when high level value.

  • PDF

A Study on the Sanitary Condition of Kitchens in Food Court/Cafeterias - An Observation on Seasonal Variations (휴게음식점 주방의 환경위생상태에 관한 조사연구 - 계절별 변화를 중심으로 -)

  • Kim, Jong-Gyu;Park, Jeong-Yeong;Kim, Joong-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.2
    • /
    • pp.118-127
    • /
    • 2012
  • Objectives: This study was undertaken to assess the sanitary conditions in the kitchens of food court/cafeterias and determine seasonal variations. Methods: We measured environmental factors (air temperature, relative humidity, illumination intensity, noise level), and dropping airborne microbes (bacteria and fungi) in the kitchens of eight food court/cafeterias in four seasons (January, April, July, and October). Air temperature and relative humidity were measured with in/out thermo-hygrometers at 1.2-1.5 m above floor level. Illuminance measurement was performed through the multiple point method of Korean Standards (KS). Noise level was measured by the standard methods for the examination of environmental pollution (noise and vibration) of Korea. The estimation of dropping airborne bacteria and fungi was performed through use of Koch's method. Results: The highest kitchen air temperature was in July, and the lowest in January. The average temperature surpassed $21^{\circ}C$ throughout the seasons, suggesting a higher temperature than required for the safe handling of food. Humidity in all the kitchens was measured in the range of 50-60%. Half of the kitchens showed illumination intensities below 300 Lux in April. It was found that the sound pressure level of noise in almost all of the kitchens was higher than 85 dB (A). The highest levels of dropping airborne bacteria and fungi were noted in July. The numbers of airborne bacteria were higher than those of fungi. The levels of dropping airborne bacteria and fungi were affected by air temperature, relative humidity, season, and place. Conclusions: This study indicates that the kitchen environments were unqualified to supply safe food. The hygiene level of the kitchens should be improved.

The dynamic stiffness of resilient materials for floor impact sound according to temperature change (온도변화에 따른 바닥충격음 완충재의 동탄성계수 변화)

  • Yeon, Junoh;Goo, Heemo;Lee, Sungchan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.338-342
    • /
    • 2018
  • In order to solve the floor impact sound problem in the upper and lower floors, the Ministry of Land, Transport and Maritime Affairs also notifies the physical properties of the resilient material affecting the floor impact sound level. The dynamic modulus of elasticity and the loss factor before and after heating are most related to the floor impact noise, especially for the cushioning material. Therefore, in this study, the rate of change with respect to the dynamic modulus and loss factor with temperature change was examined by increasing $10^{\circ}C$ by $10^{\circ}C$ from the temperature condition of $70^{\circ}C$ specified in the standard. The dynamic modulus of elasticity and the loss modulus were measured by using the pulse excitation method for eight kinds of samples. The calculation method was calculated by the time series analysis method using the damped vibration waveform.

Design and Implementation of an Indoor Particulate Matter and Noise Monitoring System (실내 미세먼지 및 소음 모니터링 시스템 설계 및 구현)

  • Cho, Hyuntae
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.17 no.1
    • /
    • pp.9-17
    • /
    • 2022
  • As the COVID-19 pandemic situation worsens, the time spent indoors increases, and the exposure to indoor environmental pollution such as indoor air pollution and noise also increases, causing problems such as deterioration of human health, stress, and discord between neighbors. This paper designs and implements a system that measures and monitors indoor air quality and noise, which are representative evaluation criteria of the indoor environment. The system proposed in this paper consists of a particulate matter measurement subsystem that measures and corrects the concentration of particulate matters to monitor indoor air quality, and a noise measurement subsystem that detects changes in sound and converts it to a sound pressure level. The concentration of indoor particulate matters is measured using a laser-based light scattering method, and an error caused by temperature and humidity is compensated in this paper. For indoor noise measurement, the voltage measured through a microphone is basically measured, Fourier transform is performed to classify it by frequency, and then A-weighting is performed to correct loudness equality. Then, the RMS value is obtained, high-frequency noise is removed by performing time-weighting, and then SPL is obtained. Finally, the equivalent noise level for 1 minute and 5 minutes are calculated to show the indoor noise level. In order to classify noise into direct impact sound and air transmission noise, a piezo vibration sensors is mounted to determine the presence or absence of direct impact transmitted through the wall. For performance evaluation, the error of particulate matter measurement is analyzed through TSI's AM510 instrument. and compare the noise error with CEM's noise measurement system.

Development of experimental water level measuring device using an Arduino and an ultrasonic sensor (아두이노와 초음파 센서를 이용한 실험용 수위 측정 장치 개발)

  • Yoo, Moonsung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.143-147
    • /
    • 2018
  • Water levels are measured in various fields such as sewage treatment plants, water treatment plants, rivers, dams, factory storages' tanks. Ultrasonic instruments for water level measurement are expensive and are used for industrial field. Rapid advances in electronics have made it possible to build a wide variety of measurement, monitoring and control functions at low cost. This study was started to make ultrasonic level measurement system at low price. The system was constructed with an Arduino, an ultrasonic sensor and a temperature sensor for use in the experiment. The ultrasonic sensor measures the time from the sensor to the liquid surface. The temperature sensor measures the atmospheric temperature and improves the accuracy of the ultrasonic distance measurement by correcting the sound speed. Arduino controls measurements and calculates the water level. All components of the system are assembled into a device holder. Experiments with this system show that the water level measured by the system is very close to the actual value. This system is also inexpensive and easy to install and maintain, making it suitable for laboratory use.

A Study on the Transmission Path of Shipboard Structure-Borne Noise-Using SAE (SEA법에 의한 선박고체소음의 전파경로에 대한 해석적 연구)

  • 현명환;김사수
    • Journal of KSNVE
    • /
    • v.6 no.5
    • /
    • pp.575-585
    • /
    • 1996
  • In order to build a quiet and comfortable ship, the noise levels on board ship must be predicted at early design stage. Statistical Energy Analysis (SEA) developed by R. H. Lyon has been well known to be the most useful frame work to study the energy flow of noise and vibration in structure. This paper applied this theory to predict the transmission loss of structure-borne noise of model structure and has developed computer program. Components constructions model structure have been all considered as SEA elements. And we also estimated the SEA parameters from the model structure. Using SEA and a new conception of STL, we found the transimission character of structure-borne noise theoretically by the idealized ship model, and then compared the results with three cases.

  • PDF

Development of an Acoustic Enclosure for the Large Low-Noise Transformer (저소음 변압기용 조립식 철판 방음실 개발)

  • Lee, Jun-Shin;Lee, Wook-Ryun;Kim, Seok-Man;Koo, Kyo-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.87-88
    • /
    • 2007
  • An acoustic total or partial enclosure is widely used to reduce the sound pressure level propagating from a noise source. However, the performance of the acoustic enclosure is decreased by its inherent limitations such as temperature rise or acoustic pressure build-up inside the enclosed acoustic field. In this reason, an acoustic enclosure consisting of a silencer and absobent panels with acoustic resonators is studied to reduce the transmitted noise from a transformer. Large sound-attenuation is expected by applying the enclosure to the large transformers in a substation.

  • PDF

Basic Study on the Performance Improvement of HD Diesel Engine (대형 디젤엔진의 소음 개선에 대한 기초 연구)

  • 김규철;이삼구;주봉철;노병준
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.1
    • /
    • pp.181-188
    • /
    • 2001
  • The evaluation of the noise for the an existing engine was carried out to improve the current noise level. The applied techniques were 1m air-borne noise, combustion noise analysis, torsional analysis at the front pulley and sound pressure intensity. In addition, the evaluation of the possibility to the noise reduction by means of wrapping the parts was performed to propose the detailed information in engine design. In view of the obtained results, the following countermeasures were recommended to reduce the current noise level through the above methods. Furthermore, in order to assess the influence of combustion noise on the overall engine noise, the noise test was also performed by the change of intake air temperature up to 5$0^{\circ}C$ in steps of 1$0^{\circ}C$. Finally, the fixed design specifications to reduce the engine noise will be decided in consideration of the test data for proto type engine.

  • PDF