The CO Gas Concentration Characteristics in a Sound Proof Road Tunnel According to the Upper Opening Installation Distance Interval (방음터널 내부의 상부배출구 간격에 따른 CO 농도분포 특성)

  • Park, Myung Sig
    • Journal of ILASS-Korea
    • /
    • v.21 no.3
    • /
    • pp.162-169
    • /
    • 2016
  • When we construct a road near an apartment complex, we consider a soundproof wall. To make residential places quieter, we may consider a soundproof road tunnel. Such a tunnel, however, would become highly concentrated with soot from vehicles whenever a traffic jam might occur. To create an optimum design, this study utilizes the PHOENICS-VR software. The work considers three cases: (1) no openings (2) openings at 30m intervals, and (3) openings at 60m intervals on the upper side of the tunnel. The study finds that in the second case shows CO concentration distributions were 15% less than those without openings. And the CO concentration distributions of the second and third cases are almost the same. The findings suggest that we should make the soundproof tunnel to reduce construction fees.

Investigation of Noise Spectrum Characteristics for an Evaluation of Railway Noise Barriers

  • Koh, Hyo-In;Jang, Seungho;Hong, Ji-Young
    • International Journal of Railway
    • /
    • v.6 no.3
    • /
    • pp.125-130
    • /
    • 2013
  • Most of the test methods used for determining the acoustic performance of the noise barriers in Korean standards address the sound-proof panels but refer to noise barriers as a whole system or their in-situ performances less. Many new types of trains with different operating speeds have been developed and produced, and civil appeals against railway noise are becoming quite extensive. Considering these latest changes of circumstances, it is necessary to investigate the current standards and specifications pertaining to railway noise barriers. In this paper, criteria for the measurements and evaluations of noise barriers and sound-proof panels are examined and experimental studies are introduced. In order to suggest more efficient methods for reasonable evaluations of the noise barriers, frequency spectrums of the noise source, the power of the actual railway vehicles, are investigated and introduced.

A Study on the Thermal Conductivity and Floor Impact Sound of Polyurethane Concrete (폴리우레탄 콘크리트의 열전도율과 바닥충격음에 관한 연구)

  • 강재홍;조영국;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.676-681
    • /
    • 1997
  • The purpose of this study is to evaluate the thermal Conductivity and Foolr Impact Sound of Polyurethane Concretes. The Polyurethane Concretes are prepared with various resin content, Fine and Coarse aggregates content, and its thickness, and tested for the Thermal Conductivity and Impact Sound. From the test results. the sound insulation grade of polyurethane concretes by the floor impact sound test on high frequency band is L-60, and its effect is considerable Polyurethane concretes have high degree of solidity compared with other heat shield materials, and its thermal conductivity is 0.05kcal/$mh^{\cire}C$. And it is suitable for sound proof floor materials.

  • PDF

The Effect of Office Layouts and Ambient Office Sounds on the Simple Tasks of White Collar Workers

  • Yoon, Heakyung Cecilia
    • Architectural research
    • /
    • v.8 no.2
    • /
    • pp.11-16
    • /
    • 2006
  • The purpose of this study is to scrutinize the effect of office layouts and ambient office sounds on the performance of office workers involved with a proof-reading test (simple task). Twenty subjects, who were professional researchers and computer programmers, were from three different office layouts: 1) Nine subjects from a combined office type with open meeting places and closed individual offices; 2) five from an open office with rectangular individual workstations, and 3) six from an open office with triangular individual workstations. Architects and consultants working in the field of office have reported from interviews and their own observations that occupants' satisfaction differs as their office layouts vary although the sizes are the same. This finding leads to the hypothesis of this experiment. Proof-reading test results were obtained from three different office layouts (combined office type, rectangular and triangular individual workstations in open offices) under two different sound conditions (quiet background sound and ambient sound of their own workplace) for 10 minutes. The test analysis shows the mean test score of subjects from the triangular individual workstations in open offices is significantly different from the mean test scores of subjects from the combined office type and the rectangular individual workstations in open offices.

Planting Design in Green Open Space, Urban Area : Planting Evaluation of Buffer Green Space in Housing Complex (도시지역 녹화공간의 배식기법 : 공동주택단지 완충녹지의 배식)

  • Cho, Woo
    • Korean Journal of Environment and Ecology
    • /
    • v.12 no.1
    • /
    • pp.78-90
    • /
    • 1998
  • An objective of this study was to provide database for the planting disign of buffer green space. Types, planting structure, and effect of vuffer green space were investigated in five housing complexes of newtown of metropolitan area, Korea. Buffer green space in the study sites were constructed as mounding, slope, and plate. The number of species was found 20 tree and sub-tree species(10 evergreen and 20 deciduous species ) and 13 shrub species. These species were planted in one-storyed planting structure and there was no difference with ornamental species in the urban parks. Effect of sound proof by the buffer green space was recognized but sound level in four types among the seven types was observed above standard sound level for housing complex(65dB). Effect of sound proof was especially most effective in the mounding type. It was found that planting density and index of plant crown volume were mot satisfied to the function of buffer green space because of lower density and crown volume than natural vegetation per unit. Based on these results, this study suggested that buffer green space is desirable to be developed in the mounding type over two meters height with multi-layer planting model. In addition, there is needed to consider vegetation structure of natural forest around the developing site.

  • PDF

Development of Noise-proof Facility Considered with Soundproofing Materials in a Tunnel Blasting (터널 발파에서 방음재질을 고려한 방음문 개발에 관한 연구)

  • Jeoung, Jae-Hyeung;Won, Yeon-Ho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.3
    • /
    • pp.27-35
    • /
    • 2011
  • This study investigated a sound reduction degree by each soundproofing materials and the sound pressure level of a main frequency range to develop soundproofing facilities installed for reducing sound in a tunnel blasting. The frequency range and sound pressure level of soundproofing materials(eg. sand and water etc.) mainly used at a working spot were measured using the experimental apparatus considered with blasting situation. The full scale pilot test was also carried out using developed soundproofing facilities in this study. And the performance of developed soundproofing facilities was analyzed. As a result, the developed soundproofing facilities using water in sound insulation materials could reduce about 10dB(A) of blasting noise in compare with the existing soundproofing facilities.

A study on the Effect of Plant Growth for Ecological Sound Barrier Development (생태방음벽 개발을 위한 식물생장의 효과에 관한 연구)

  • Bashyal, Sarita;Cho, Hae-Yong;Choi, Chang-Ha
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.3
    • /
    • pp.607-612
    • /
    • 2009
  • For the development of ecological sound proof wall, successful seed germination and growth of plants are very important. In our present study, we observed germination of thirty five different seed species in growth chamber at $24^{\circ}C$, humidity 60% and alternation of 12 hours photoperiods. Germination of same seeds were carried out at room temperature on 6:4, 7:3, 8:2, and 9:1 proportion of pure and mineral soils respectively. Out of studied species, maximum germination was recorded for Perennial penant (92%), followed by Brassica napus (86%), and Silene armeria (82%). The measurement of root/shoot length showed, maximum root/shoot length for Perennial penant, followed by perennial sonata and Rebolsentri sp. Based on germination percentage and root/shoot length of germinating seeds, we considered Perennial penant, perennial sonata and Rebolsentri sp. were proper species for the construction of ecological sound proof walls

Evaluating of Road Traffic Noise in Apartment Sites With Calculations of Equivalent Noise Levels (단지등가소음도 계산을 통한 공동주택 교통소음 평가방법에 관한 연구)

  • 김경호;전진용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.1040-1044
    • /
    • 2001
  • This study is to propose an analyzing method of road traffic noise in apartment sites using computer simulation program. The evaluation method used in this study is to calculate "Site Equivalent Noise Level". It will be possible to set up effective sound proof system with calculation of "The Number of Houses Exceeding Standard Noise Level".

  • PDF

Source Identification and Reduction of Noise for the Outdoor Unit of Room Air Conditioner (실외기 소음원 규명 및 소음저감)

  • 서상호;이근동;이내영;진심원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.575-581
    • /
    • 1998
  • The noise sources in the outdoor unit of RAC(Room Air Conditioner) are identified by the sound intensity method. The main noise sources are compressor noise and fluid noise which is caused by the fan, heat exchanger and shroud. First, the fluid noise is reduced through the design ol new fan and shroud with high flow rate and low noise, reduction of the system resistance by rearrangement of heat exchanger, and optimization of the complex parameter between the fan and shroud. Next, in order to reduce the compressor noise, the new shape of compressor mount and sound-proof material was applied. As a result, the overall noise was reduced by 4-5dB(A).

  • PDF

Establishment for Regulation Standards of Architectural Facility Noise Using Psycho-acoustic Experiment (청감실험을 이용한 건축 설비소음의 규제기준 설정)

  • Ju, Duck-Hoon;Yun, Jae-Hyun;Kim, Jae-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.11
    • /
    • pp.1001-1008
    • /
    • 2010
  • The architectural, facility makes the housing environment more pleasant, while too much noise coming from machinery room is detrimental to the workers physically and mentally. Therefore, more sound insulation and sound proof policies are increasingly required. However, as the annoyance caused by facility noise is influenced by various human listening characteristics as well as physical characteristics such as sound pressure level, it requires subjective evaluation characteristics through acoustic-psychological approach. For this purpose, the facility noise in the machinery room was actually measured and analyzed in the field to understand physical characteristics, and the correlation between physical evaluation value and psychological response value through listening test. Further, this study aims at presenting the data to set the standards of 'Just noticeable difference' of the facility noise together with reasonable evaluation with psychological reaction, through the grading of facility noise using trend formula. In the result, 13 stages of physical properties were forecasted for each evaluation method, together with 'Just noticeable difference' using the grading of architectural facility noise.