• 제목/요약/키워드: Sound Pressure Level

검색결과 690건 처리시간 0.034초

소음수준에 따른 신체자세동요의 변화 (Sound Levels and Postural Body Sway during Standing)

  • 박성하;이승원
    • 대한인간공학회지
    • /
    • 제25권3호
    • /
    • pp.1-15
    • /
    • 2006
  • Loss of postural balance can possibly lead to increased risk of slips and falls in work places. Present study was performed to investigate the effects of noisy environments on postural stability during standing. It is known that a sound is characterized by the frequency and pressure level of the sound. Therefore, effects of the frequency and pressure level on postural stability were of primary concern. Ten male subjects participated in the experiment. Subject's center of pressure(COP) position was collected on a force plate while they were exposed to different frequency and pressure levels of the sound. Measured COP was then converted into the length of postural sway path in both anterior-posterior(AP) and medio-lateral(ML) axis. Results showed that the length of sway path in AP axis was significantly affected by the frequency of sound. The length of sway path was lowest at frequency level of 2000Hz and increased below and above this frequency range. The sound pressure level, however, did not significantly affect the postural sway length in both AP and ML axis. The results imply that industrial workers in noisy environments should be aware that their abilities of postural balance can be disturbed significantly.

정압을 이용한 직교류팬 주변의 소음 예측 (Estimation of Noise Level near Cross Bow Fan by Measurements of Static Pressure.)

  • 김재원;조용;정윤영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.1156-1161
    • /
    • 2001
  • A significant trial has been performed for estimation of noise level of a cross flow fan for air conditioning system. In general, measurements of noise level of machinery require rigorous equipment involving an anechoic chamber with precision gauges. The apparatus is expensive to utilize and is not easy to construct. In this work, we adopt static pressure sensing from an ordinary pressure transducer for prediction of noise level of a rotating fan. The present procedure is finding sound pressure from the static pressure by manipulating Light-Curle equation depicts noisy energy in terms of pressure on surfaces of noise generators. Sound power level near core unit of the fan is evaluated with the present methodology in a normal laboratory room without any sound absorbers. The method is easy and shows good prediction results compared with precise measurements by using microphones.

  • PDF

장방향 복도 공간의 비상방송설비에 대한 음압 레벨과 음성 명료도 비교 (Comparison of Sound Pressure Level and Speech Intelligibility of Emergency Broadcasting System at Longitudinal Corridor)

  • 정정호;이성찬
    • 한국화재소방학회논문지
    • /
    • 제32권4호
    • /
    • pp.42-49
    • /
    • 2018
  • 본 연구에서는 건축음향시뮬레이션을 통하여 재실자에게 비상방송 설비에서 발생되는 비상 방송음이 명확하게 전달되는지를 알아보기 위하여 장방형 복도를 대상으로 NFSC 202의 기준에 따라 25 m 간격으로 비상 방송용 확성기가 설치되었을 때 건축마감재료 변경에 따라 음압레벨, 음성명료도 지표를 비교분석하였다. 마감재료로 흡음특성이 낮은 재료를 적용한 경우 충분한 음압 레벨은 확보할 수 있었지만, 재실자가 비상 방송음을 알아듣기 매우 어려운 수준의 음성명료도를 보였다. 마감재료로 흡음재료를 적용함에 따라 음성 명료도, 음성 전달 지수는 재실자가 잘 알아들을 수 있는 수준으로 개선이 가능한 것으로 나타났지만 재실자에게 전달되는 음압 레벨이 감소되며 같은 공간 내 레벨 차이가 크게 발생되는 것으로 나타났다. 따라서 흡음재료를 사용하여 음성명료도를 확보하고자 할 경우 고른 음압 레벨 분포를 확보하기 위하여 비상 방송용 확성기를 설치간격 조정 등이 필요한 것으로 나타났다.

외부소음에 대한 공동주택 실내 소음레벨분포에 관한 실험적 연구 (An Experimental Study on the Prediction of Indoor Sound Level Distribution in Apartment for Exterior Noise)

  • 박현구;김종빈;강동영;장현충;송혁;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.259-264
    • /
    • 2001
  • It is necessary to predict the sound pressure level(SPL) in rooms before designing an apartment when exterior noises are produced. In order to predict SPL for an apartment that has some specific exterior noises, the following should be known: the characteristics of outdoor noise, sound insulation performance and sound level differences of each room. The purpose of this study is to find out the possibility of predicting sound pressure level of rooms in an apartment by analysing sound level differences among rooms. Sound sources used in this experiment are construction noise, aircraft noise, railroad noise, road traffic noise and white noise as a reference to compare with the previous four. These noises were recorded and reproduced by speaker. As a result, we found that within the sound reduction pattern, the sound difference level appeared uniform depending on the sound insulation characteristics of the windows installed when facing the noise source. When the windows having the same acoustic performance were installed, the SPL in each room resulted in nearly the same values.

  • PDF

NCPX를 이용한 도로 표층 유형별 노면 소음 비교 연구 (A Study for Comparing Road Noise by Surface Types using NCPX)

  • 강원평;문학룡
    • 한국도로학회논문집
    • /
    • 제15권6호
    • /
    • pp.61-68
    • /
    • 2013
  • PURPOSES : The purpose of this study is to study the noise reducing effect of Micro Surfacing by comparing general asphalt, longitudinal tining and Slurry Seal. METHODS : This study measures vehicles' noise of each section by the NCPX method that can measure noise between the road surface and the tire at the field. Total sound pressure and sound pressure level by the 1/3 octave band frequency are calculated through the field data of each section. Total sound pressure level is compared by ANOVA test statistically. After ANOVA test, post-hoc test is conducted to know mean difference of surface type by Tukey. RESULTS : As the result of CPB analysis to confirm sound pressure levels by frequency, it was shown that sound pressure levels by frequency are totally similar except for those of frequency bands between 100Hz and 500Hz. The result of ANOVA test and post-hoc test, it was shown that sections of surface type have a difference. The result of Micro Surfacing was lower 2~5dB(A) than other surface type. CONCLUSIONS : It is found that the noise reduction performance of Micro Surfacing was better than other surface type.

임펄스응답적분법을 이용한 잔향시간의 측정방법이 규준화 바닥충격음레벨에 미치는 영향 (Effect of the Measuring Method of Reverberation Time Using Impulse Response Method on the Normalized Impact Sound Pressure Level)

  • 이주원;권영필
    • 한국소음진동공학회논문집
    • /
    • 제16권1호
    • /
    • pp.34-39
    • /
    • 2006
  • For the evaluation of the normalized impact sound pressure level, the reverberation time of the receiving room should be measured. This paper deals with the effect of the time constant of FFT analyzer and the measuring points on reverberation time. It is found that the time constant should be in the range between 10 ms and 35 ms. While the effect of measuring points on the reverberation time is significant when the bandwidth is narrow it is negligible in the evaluation of the normalized impact sound pressure level.

KRISS에서 수행된 음향관련 교정 및 시험 동향 (Tendency of Calibration and Test for Acoustic Field in KRISS)

  • 서재갑;권휴상;정성수;조문재;서상준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.448-452
    • /
    • 2002
  • We report the number of calibration and test for acoustic field which were conducted in KRISS between the year of 1990 and 2001. The items contain sound level meter and calibrator for calibration and sound absorption coefficient, transmission loss, sound pressure level of siren, sound pressure level and power of acoustic instrument and relative accessories for test. The data show that the number of them have been increased continuously.

  • PDF

송풍기${\cdot}$압축기의 소음레벨 측정방법 KS B 6361의 개정 (Method of A-Weighted Sound Pressure Level Measurement for Fans, Blowers and Compressors)

  • 이승배;김경호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.189-199
    • /
    • 1999
  • The revision was proposed for methods A-weighted sound pressure measurement for fans, blowers and compressors in order to apply newly developed measurement techniques to KS B 6361 established in 1987. This proposal includes modification of terminologies, revision of sound power methods for radiated sound from the body, inclusion of In-duct measurement method, and correction method for flow noise upon microphon.

  • PDF

사운드스케이프 적용을 위한 옥외 P.A. 시스템의 적정 인지레벨에 관한 실험적 연구 (An Experimental Study on the Optimistic Recognition Level of Public Address System as a Soundscape Application Facility)

  • 송민정;장길수
    • 한국소음진동공학회논문집
    • /
    • 제17권11호
    • /
    • pp.1050-1055
    • /
    • 2007
  • P.A.(public address) system is considered as an useful active soundscape appliance which can gives a place identity and vitality by introducing conventional musics, environmental musics, bird singing sounds etc. In this study, the main aim is to know the optimistic distance from the speaker and sound pressure level range of introducing sound. So, the sound pressure level of P.A. system due to distances were measured and subjects' responses with level variations were checked. The main results are as follows. Level range from 64 dB to 71 dB is comfortable for subjects. And the optimal level of introducing sound is related with sound source characteristics. The results of this study could be used for street furniture location design and P.A. system output level.

높은 입사 음압에서의 미세 천공판을 이용한 흡음 기구의 설계 (Design of a Micro-perforated Panel Absorber at High Incident Sound Pressure)

  • 박순홍;서상현;장영순
    • 한국소음진동공학회논문집
    • /
    • 제20권10호
    • /
    • pp.983-990
    • /
    • 2010
  • Reduction of acoustic loads of space launch vehicles can be achieved by acoustic absorbers satisfying strict cleanness requirements. This limited the use of general porous materials and requires non-porous sound absorbers. Micro-perforated panel absorbers(MPPA) is one of promising sound absorbers satisfying the cleanness requirement for launch vehicles. However, its applicability was limited to low sound pressure levels according to the acoustic impedance model of micro-perforated panels. In this paper the applicability of micro-perforated panel absorbers at high incident sound pressure was investigated in experimental ways. The absorption characteristics of a micro-perforated panel absorber was simulated according to its design variables, e.g., minute hole diameters and aperture ratios. It was shown that optimal design can be readily done by using proposed design charts. Experiments were conducted to measure acoustic properties of the designed micro-perforated panel absorbers. The results showed that acoustic resistance increases rapidly as incident sound pressure level does but change of acoustic reactance can be neglected in a practical point of view. This caused the decrease of peak value of absorption coefficient at high incident sound pressure level, but the amount of reduction can be accepted in practice. The major advantage of the micro-perforated panel absorber(wide absorption bandwidth) was still kept at high sound pressure level.