• Title/Summary/Keyword: Sonochemistry

Search Result 35, Processing Time 0.02 seconds

Preparation of Magnetic Chitosan Microsphere Particles (나노 크기의 마그네타이트 입자를 이용한 자성 키토산 미소구체의 제조)

  • Ko, Sang-Gil;Cho, Jun-Hee;Ahn, Yang-Kyu;Song, Ki-Chang;Choi, Eun-Jung
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.1
    • /
    • pp.66-70
    • /
    • 2006
  • Magnetite nanoparticles, which have been extensively used in many fields, were encapsulated with a natural polymer, chitosan, to improve their biocompatibility. We have synthesized magnetite $(Fe_3C_4)$ nanoparticles using chemical coprecipitation technique with sodium oleate as surfactant. Nanoparticle size can be varied from 1.2 to 7.4nm by controlling the sodium oleate concentration. Magnetite phase nanoparticles could be observed from X-ray diffraction. Magnetic colloid suspensions containing particles with sodium oleate and chitosan have been prepared. High magnetic property chitosan-microsphere particles were prepared from oleate-coated magnetite suspension using spray method. The surftce, and tile morphology of the magnetic chitosan microsphere particles were characterized using optical microscope and scanning electron microscope. Magnetic hysteresis measurement were performed using a superconducting quantum interference device (SQUID) magnetometer at room temperature to investigate the magnetic properties of the chitosan microspheres including magnetite nanoparticles. The SQUID measurements revealed superparamagnetism of nanoparticles.

Basic Study on the Design and Optimization of Sonoreactors for Sonochemical Water/Wastewater Treatment Processes (초음파 수처리 공정 개발을 위한 반응기 설계 기초 연구)

  • Kim, Seulgi;Son, Younggyu
    • Journal of Wetlands Research
    • /
    • v.16 no.2
    • /
    • pp.205-212
    • /
    • 2014
  • Ultrasound technology can be applied in various fields including environmental, energy, and material engineering processes. In this study the effect of liquid height/volume on calorimetric energy and sonochemical oxidation was investigated as one of the basic steps for the design of water/wastereater treatment sonoreactors. The liquid height was increased from 0 to $4{\lambda}$ by $1/4{\lambda}$ and it was found that both calorimetric energy and sonochemical oxidation were significantly increased at relatively high liquid height/volume where the power density was relatively low. The sonochemiluminescence (SCL) images for the visualization of the activity of cavitation also showed that larger and more stable active zone was formed with high SCL intensity at high liquid height/volume. Therefore, it was revealed that sonoreactors for water/wasterwater treatment could be significantly effective in terms of removal efficiency and energy consumption.

Effect of Ultrasound on the Decomposition of Sodium Dodecylbenzene Sulfonate in Aqueous Solution (Sodium Dodecylbenzene Sulfonate 수용액의 분해반응에서 초음파 효과)

  • Yim, Bong-Been
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.6
    • /
    • pp.561-567
    • /
    • 2004
  • The influence of ultrasound frequency, dissolved gases, and initial concentration on the decomposition of sodium dodecylbenzene sulfonate(DBS) aqueous solution was investigated using ultrasound generator with 200 W ultrasound power. The decomposition rates at three frequencies(50, 200, and 600 kHz) examined under argon atmosphere were highest at 200 kHz. The highest observed decomposition rate at 200 kHz occurred in the presence of oxygen followed by air and argon, helium, and nitrogen. The effect of initial concentration of DBS on the ultrasonic decomposition was decreased with increasing initial concentration and would depend upon the formation of micelle in aqueous solution. It appears that the ultrasound frequency, dissolved gases, and initial concentration play an important role on the sonolysis of DBS. Sonolysis of DBS mainly take place at the interfacial region of cavitation bubbles by both OH radical attack and pyrolysis to alkyl chain, aromatic ring, and headgroup.

Effect of Gas Sparging on Sonochemical Oxidation in a 300 kHz Sonoreactor (300 kHz 조건에서의 초음파화학적 산화반응에 대한 연속식 가스 주입 효과)

  • Seo, Jieun;Son, Younggyu
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.6
    • /
    • pp.642-649
    • /
    • 2018
  • The effect of gas sparging on sonochemical oxidation was investigated in a 300 kHz sonoreactor under various liquid height/volume conditions ($5{\sim}30{\lambda}$, 3.4 ~ 9.0 L), determined by the wavelength of the applied frequency. The electrical input power was maintained constant for all cases . Sonochemical activity drastically decreased from $15{\lambda}$ and the liquid height of $10{\lambda}$ was suggested as the optimal height for 300 kHz without gas sparging. In our previous research, the sonochemical activity observed was five-times higher when air sparging was applied for 36 kHz. On the other hand, no enhancement was obtained at 10, 15, 25 and $30{\lambda}$ using air sparging (1, 3, and 6 L/min) for 300 kHz in this study $20{\lambda}$ and optimization of gas sparging was conducted at $20{\lambda}$ using various gases including air, Ar, $O_2$, $N_2$, and mixtures of Ar and $O_2$. It was found that gas sparging using pure Ar or pure $O_2$ resulted in lower sonochemical activity compared to that of air sparging due to the imbalance between the intensity of cavitation phenomena and the generation of oxidizing radical species. Consequently, the gas mixture of $Ar:O_2$ = 80 % : 20 % (DO saturation ${\approx}100%$) was suggested as an optimal gas sparging condition.

Preparation of Biopolymer coated Magnetite And Magnetic Biopolymer Microsphere Particles for Medical Application (의학적 응용을 위한 생체 고분자로 피복 된 자성 나노 입자와 미소구체의 제조)

  • Ko, Sang-Gil;Cho, Jun-Hee;Ahn, Yang-kyu;Song, Ki-Chang;Choi, Eun-Jung
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.4
    • /
    • pp.221-227
    • /
    • 2006
  • We have synthesized uniform nanometer sized magnetite particles using chemical coprecipitation technique through a sonochemical method with surfactant such as oleic acid. Magnetite phase nanoparticles could be observed from X-ray diffraction. Magnetite nanoparticles is surface phase morphology and biopolymer-microspheres for Application Medical. Magnetite nanoparticles coated biopolymer. Atomic Force Microscope (AFM) was used to image the coated nanoparticles. Magnetic colloid suspensions containing particles with sodium oleate, chitosan and $\beta$-glucan have been prepared. The morphology of the magnetic biopolymer microsphere particles were characterized using optical microscope. Magnetic hysteresis measurement were performed using a superconducting quantum interference device (SQUID) magnetometer at room temperature to investigate the magnetic properties of the biopolymer microspheres and magnetite coated biopolymer including magnetite nanoparticles. Magnetic Resonance (MR) imaging was used to investigate biopolymer coated nanoparticles and biopolymer microspheres.