• Title/Summary/Keyword: Song mode

Search Result 1,048, Processing Time 0.033 seconds

Improvement of Gain and Frequency Characteristics of the CMOS Low-voltage Current-mode Integrator (CMOS 저전압 전류모드 적분기의 이득 및 주파수 특성 개선)

  • Ryu, In-Ho;Song, Je-Ho;Bang, Jun-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3614-3621
    • /
    • 2009
  • In this paper, A CMOS low-voltage current mode integrator is designed. The designed current-mode integrator is based on linear cascode circuit that is newly proposed in this paper. When it is compared with gain(43.7dB) and unity gain frequency(15.2MHz) of the typical current-mirror type current-mode integrator, the proposed linear cascode current-mode integrator achieves high current gain(47.8dB) and unity gain frequency(27.8MHz). And a 5th Chebyshev current-mode filter with 7.03MHz cutoff frequency is designed. The designed all circuits are simulated by HSPICE using 1.8V-$0.18{\mu}m$ CMOS technology.

Self-timed Current-mode Logic Family having Low-leakage Current for Low-power SoCs (저 전력 SoC를 위한 저 누설전류 특성을 갖는 Self-Timed Current-Mode Logic Family)

  • Song, Jin-Seok;Kong, Jeong-Taek;Kong, Bai-Sun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.8
    • /
    • pp.37-43
    • /
    • 2008
  • This paper introduces a high-speed low-power self-timed current-mode logic (STCML) that reduces both dynamic and leakage power dissipation. STCML significantly reduces the leakage portion of the power consumption using a pulse-mode control for shorting the virtual ground node. The proposed logic style also minimizes the dynamic portion of the power consumption due to short-circuit current by employing an enhanced self-timing buffer. Comparison results using a 80-nm CMOS technology show that STCML achieves 26 times reduction on leakage power consumption and 27% reduction on dynamic power consumption as compared to the conventional current-mode logic. They also indicate that up to 59% reduction on leakage power consumption compared to differential cascode voltage switch logic (DCVS).

A Adaptive Garbage Collection Policy for Flash-Memory Storage System in Embedded Systems (실시간 시스템에서의 플래시 메모리 저장 장치를 위한 적응적 가비지 컬렉션 정책)

  • Park, Song-Hwa;Lee, Jung-Hoon;Lee, Won-Oh;Kim, Hee-Earn
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.12 no.3
    • /
    • pp.121-130
    • /
    • 2017
  • NAND flash memory has advantages of non-volatility, little power consumption and fast access time. However, it suffers from inability that does not provide to update-in-place and the erase cycle is limited. Moreover, the unit of read/write operation is a page and the unit of erase operation is a block. Therefore, erase operation is slower than other operations. The AGC, the proposed garbage collection policy focuses on not only garbage collection time reduction for real-time guarantee but also wear-leveling for a flash memory lifetime. In order to achieve above goals, we define three garbage collection operating modes: Fast Mode, Smart Mode, and Wear-leveling Mode. The proposed policy decides the garbage collection mode depending on system CPU usage rate. Fast Mode selects the dirtiest block as victim block to minimize the erase operation time. However, Smart Mode selects the victim block by reflecting the invalid page number and block erase count to minimizing the erase operation time and deviation of block erase count. Wear-leveling Mode operates similar to Smart Mode and it makes groups and relocates the pages which has the similar update time. We implemented the proposed policy and measured the performance compare with the existing policies. Simulation results show that the proposed policy performs better than Cost-benefit policy with the 55% reduction in the operation time. Also, it performs better than Greedy policy with the 87% reduction in the deviation of erase count. Most of all, the proposed policy works adaptively according to the CPU usage rate, and guarantees the real-time performance of the system.

The performance of a heat pump with 3-piping system at various charging conditions (3관식 시스템 히트펌프의 충전량 변화에 따른 성능 특성에 관한 연구)

  • Song, In-Sik;Choi, Jong-Min;Joo, Young-Ju;Chung, Hyun-Joon;Kang, Hoon;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.288-293
    • /
    • 2008
  • The cooling load in winter is significant in many commercial buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. The development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the performance of a multi-heat pump with 3-piping system was investigated as a function of refrigerant charge and its performance was analyzed in cooling mode, heating mode, and heat recovery mode. COP in the heating or cooling mode showed little dependence on refrigerant charge at overcharge conditions, while those were strongly dependent on refrigerant charge at undercharge conditions and outdoor inlet temperature. In the heat recovery mode, the performance of the system was very sensitive to charge amount at all conditions. Optimum charge amount in the heat recovery mode was 14% lower than that in the cooling mode at the standard condition because the refrigerant only passed the indoor units. It is required to store the excessive refrigerant charge in a storage tank to optimize the system performance at operating modes.

  • PDF

SPACEBORNE TOPS SAR SYSTEM MODELING AND PERFORMANCE ANALYSIS (TOPS 위성 SAR 모드 시스템 구현 및 성능 평가 연구)

  • Kang, Seo-Li;Song, Jeong-Hwan;Kim, Bum-Seung;Kim, Hyeon-Cheol;Lee, Woo-Kyung
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.2
    • /
    • pp.74-79
    • /
    • 2014
  • Conventional ScanSAR mode has been adopted in Envisat or Radarsat and played an important role to acquire wide swath SAR images for environmental surveillance. However, it suffers from the undesirable scalloping effect caused by non-homogeneity of antenna pattern while the image resolution is sacrificed. In recent years, TOPS mode has been suggested and put into use to overcome the disadvantages of the conventional scanning mode. Although TOPS mode is able to produce wide-swath SAR image in a short time interval, it demands highly complicated system design knowledge. In this paper, we present the operation principle of TOPS mode and a full SAR simulation is performed to generate TOPS SAR raw data. Azimuth antenna pattern is modified during TOPS mode operation and it is shown that the undesired scalloping effect is suppressed in the generated SAR image.

An Analysis of Access and Egress Mode Choice to Regional Railway Station using Transit Smart Card Data (a case of Seoul station) (지역 간 철도 이용객의 접근통행 패턴 연구)

  • Choi, Myoung-Hun;Eom, Jin-Ki;Lee, Jun;Moon, Dae-Seop;Song, Ji-Young
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.595-600
    • /
    • 2011
  • This study analyzed passenger's access modes that connect to regional railway station and developed a model of access mode choice based on transit smart card data of Seoul station as a case study. The study boundary includes sixteen bus stops around the station. The results show that most passengers access to station have less than two transfers. Of total 15000, eighty percent of passengers use metro and the rest of people take a bus. Interestingly, it is found that almost same proportions of passengers use metro and bus for egress the station. Consequently, metro is found to be most likely used mode compared to bus for both access and egress trips.

  • PDF

A study of regenerative inverter system with capability of harmonic reduction (고조파 저감 능력을 가진 회생용 인버터 시스템 연구)

  • Choi, Chang-Youl;Bae, Chang-Hwan;Jang, Su-Jin;Song, Sang-Hun;Won, Cung-Yeun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.443-448
    • /
    • 2005
  • This paper proposed a regeneration inverter system, which can regenerate the excessive power form dc bus line to ac source for traction system. The proposed regeneration inverter system for dc traction can reduce harmonics which are include to ac current source. The regenerative inverter is operated as two modes. As a regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and as an active power filter mode, it can compensate for harmonic distortion produced by the rectifier substation. In the paper, a regeneration inverter used PWM DC/AC converter algorithm. And an active power filter used p-q theory. The simulation was composed as a prototype model[3kW]. Simulation results show that two algorithm can be used to real model[100kW]. Finally, the inverter was successfully operated as regeneration mode.

  • PDF

Life Analysis of Flexible Tubes Fitting for Pneumatic system (공기압용 관연결 피팅의 수명 분석)

  • Kang, Bo-Sik;Song, Joo-Sub;Yoo, Yung-Chul;Kim, Hyoung-Eui
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1842-1847
    • /
    • 2007
  • In this study, we are to analyze the life and the main failure mode of flexible tubes fitting for pneumatic that are usually applied in the factory automation line. Flexible tubes fitting for pneumatic have complicated failure cause because they are organized as a complex of various elements. Therefore, in this paper, we analyzed the main failure mode of flexible tubes fitting for pneumatic, and then performed life test and performance test according to the international standards. On the basis of these processes, we estimate shape parameter that is the main factor for the calculation of test time for the reliability of flexible tubes fitting for pneumatic and their data analysis of life distribution.

  • PDF

Study on Museum Digital Exhibition Mode and Industrialization of Intangible Cultural Heritage

  • Bai, Jian-Song;Boo, Jong-Chul
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.2
    • /
    • pp.129-134
    • /
    • 2011
  • Nowadays, most of exhibits are material antiquities while the exhibit of intangible cultural heritage is deficient and the form is less advanced which cannot meet the exhibition needs of digital times. This has resulted in insufficient display of intangible heritage's value which may not facilitate inherit and protection of intangible heritage, no other than protection mechanism of forming healthy industrialization. This article has established digital exhibition mode in museum about intangible cultural heritage by analysis on current museum and using mobile communication and augmented reality techniques. Discuss the mode in the layer integrating creative industry and mobile industry and provide practicable reference project of forming the healthy industrialization mechanism for protecting intangible heritage.

A Study on Characteristics of Step-down Piezoelectric Transformer Using Contour Extended Vibration Mode (경방향 확장 진동모드를 이용한 강압용 압전변압기의 특성에 관한 연구)

  • Lee, Won-Jae;Min, Bok-Ki;Song, Jae-Sung;Chong, Hyon-Ho;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.638-641
    • /
    • 2002
  • This paper presents design and construct of flat type step-down piezoelectric transformer for the application to AC-adapters. This piezoelectric transformer operated in resonance vibration mode. In this paper, Finite element method(FEM) was used for analysis piezoelectric transformers. Vibration mode and electric field of piezoelectric transformer at resonance frequency were simulated. Using this simulation, we manufactured flat type piezoelecric transformer and measured its output characteristics. As results, output power was linearly increased by increasing input power at resonance frequency. And it was found that the transformer exhibited an output power of 11.4[W] at 60[V] input voltage. From these results, we expect that this piezoelecric transformer can be applied to AC adapters.

  • PDF