• Title/Summary/Keyword: Solution pump

Search Result 283, Processing Time 0.025 seconds

An investigation of absorption phenomena in the horizontal staggered tube absorber for various LiBr solution flow rates (LiBr용액량 변화에 따른 수평다관 흡수기의 특성 연구)

  • Kwon, Yul;Yoon, Sang-Guk
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.332-338
    • /
    • 1999
  • An experimental study of absorption phenomena of water vapor into LiBr solution was carried out to find out the optimum solution flow rate. The staggered bundle of horizontal absorption tubes, which are the same configuration as the commercial heat pump, were tested. The results showed that the heat transfer and absorption rate were enhanced with the increase of LiBr solution flow rate. Those values for different absorber pressures showed the same qualitative trends. The optimum flow rate of solution was obtained as three times of the designed flow rate.

  • PDF

Measurements of Vibration and Pressure of an Oxidizer Pump for a 7-tonf Turbopump with a Modified Rear Floating Ring Seal (수정된 후방 플로팅 링 실을 적용한 7톤급 터보펌프 산화제 펌프의 진동 및 압력 측정)

  • Bae, JoonHwan;Kwak, Hyun-Duck;Choi, ChangHo;Choi, JongSoo
    • Tribology and Lubricants
    • /
    • v.36 no.5
    • /
    • pp.253-261
    • /
    • 2020
  • In this paper, we present an experimental investigation of the frequency characteristics and a visual inspection of an oxidizer pump with a modified rear-floating ring seal for a 7-tonf turbopump. An oxidizer pump typically operates at high rotational speeds and under cryogenic conditions. Despite its low hydraulic efficiency, the floating ring seal is frequently employed as a leakage control solution for turbomachinery because it effectively reduces abrasion by friction. When the oxidizer pump starts up, the floating ring moves excursively but locks up stably against the pump casing when the contact pressure increases. The compressive force on the floating ring depends on the hydrodynamic forces induced by the flow through the floating ring. This force is controlled by the nose position of the floating ring. Based on a validation test for a 7-tonf turbopump with two types of floating rings, we concluded that the floating ring with a small diameter nose can move easily with a low contact pressure in the cooling path. This leads to instability of the pressure fluctuation around the floating ring. In contrast, a floating ring with a large diameter nose has a high contact pressure and attaches strongly to the casing, which causes wear and frictional oxidation between the contact surfaces of the impeller and the floating ring.

Reliability Investigation of a Pump-Turbine System at Various Operating Conditions (운전조건에 따른 펌프 터빈 시스템의 안정성 연구)

  • Chen, Chengcheng;Singh, Patrick Mark;Choi, Young-Do
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.3
    • /
    • pp.46-52
    • /
    • 2015
  • Pump-turbine system is widely used by the hydropower industry for stabilizing the electrical grid in the vast growing economy of most developed countries. This study only investigates the Fluid-structure Interaction (FSI) analysis of the pump-turbine system at various operating conditions. The FSI analysis can show how reliable each component of the system is by providing the engineer with a better understanding of high stress and deformation points, which could reduce the lifespan of the pump-turbine. Pump-turbine components are categorized in two parts, pressurized static parts and movable stressed parts. The fixed parts include the spiral casing, top and bottom cover, stay vane and draft tube. The movable parts include guide vanes and impeller blades. Fine hexahedral numerical grids were used for CFD calculation and fine tetrahedral grids were used for structural analysis with imported load solution mapping greater than 90 %. The maximum equivalent stress are much smaller than the material yield stress, and the maximum equivalent stress showed an increasing tendency with the varying of operating conditions from partial to excessive at both modes. In addition, the total deformation of all the operating conditions showed a small magnitude, which have quite small influence on the structural stability. It can be conjectured that this system can be safely implemented.

Clinical use of cold blood potassium cardioplegia (냉혈 K 심정지액의 임상적 이용)

  • Oh, Bong-Suc;Kim, Sang-Hyung;Lee, Dong-Joon
    • Journal of Chest Surgery
    • /
    • v.15 no.1
    • /
    • pp.35-39
    • /
    • 1982
  • Cold blood potassium cardioplegia, by two types of the infusion systems, was used in 45 patients who were undergone the open cardiac operation. Method A [in 25 patients] was the syringe infusion system and method B [in 20 patients] was the pump infusion system. Cold blood potassium cardioplegic solution was used less amount on method B than method A. Serum potassium was often increased significantly on method A as a result of excessive infusion of cold blood potassium cardioplegic solution. But method B, excessive infusion of cold blood potassium cardioplegic solution was prevented by reperfusion of the previous infused cold blood potassium cardioplegic solution through the recirculation system. Alteration of infused rate and concentration of potassium in cold blood potassium cardioplegic solution during infusion [which might be suggested on the method A] could be controlled on method B.

  • PDF

Effect of trace amount of ferrous and ferric ions on the dissolution of iron plate in magnetically treated 3% sodium chloride solution

  • Chiba, Atsushi;Ohki, Tomohiro;Wu, Wen-Chang
    • Corrosion Science and Technology
    • /
    • v.4 no.2
    • /
    • pp.45-50
    • /
    • 2005
  • A 3% NaCl solution of 1 $dm^3$ circulated with 1.5 $dm^3/min$ by a pump for 24 h in the presence of magnetic field. An iron plate immersed in a $100cm^3$ of test solution for 24 h. The rest potential and pH on surface fixed after 3 h. Containing 0~120 ppm of Fe(II) ion, the dissolution in the magnetically treated solution rose comparing with that in the non-magnetically treated solution. The dissolution amount reached to maximum at 50 ppm, then fixed in the non-magnetically treated solution. When Fe(II) ion existed in the magnetically treated solution, dissolution accelerated a little. In the non-magnetic treated solution containing 10~125 ppm of Fe(III) ion existed, the dissolution accelerated. The dissolution amounts reached to maximum at 50 ppm, then decreased from maximum value. In the magnetically treated solution, the dissolution amounts reached to minimum until 50 ppm, then increased from minimum value. The dissolution amounts affected larger with increasing of magnetic flux density. Fe(II), Fe(III) ions and magnetic treatment affected to formation of $Fe(OH)_2$ and/or $Fe_3O_4$ films. The magnetically treated effects memorized about one month.

Effects of Histamine Pretreatment on the subsequent Noradrenaline-induced Contraction and $K^+-Contracture$ in Rabbit Renal Artery (가토 신동맥의 고농도 Histamine에 의한 노아드레날린 유발 수축 및 K-경축 약화 기전)

  • Lee, Sung-Woo;Kim, Se-Hoon;Chang, Seok-Jong;Park, Hae-Kun
    • The Korean Journal of Physiology
    • /
    • v.23 no.2
    • /
    • pp.351-361
    • /
    • 1989
  • The contraction of renal arterial strip by no.epineph.me (NE) or 40 mM $K^+$ were Significantly attenuated after histamine $(10^{-5}\;M)-induced$ contraction. The mechanisms of this phenomenon were investigated in the helical strips of isolated renal artery with the measurement of isometric tension. The arterial strip was immersed in the tris-buffered Tyrode's solution which was equilibrated with 100% $O_2\;at\;35^{\circ}C$. The contraction was induced by NE or 40 mM $K^+$ during the recovery from the histamine-induced contraction which lasted for 15 minutes. The contraction by NE was also attenuated in the $Ca^{2+}-free$ Tyrode's solution and the increase of contraction by addition of 2 mM $Ca^{2+}$ was attenuated as well. This attenuation phenomenon was not observed in the presence of low concentration $(3{\times}10^{-7}\;M)$ of histamine. This attenuation was not affected by destruction of endothelium, pretreatment with papaverine or propranolol. This attenuation was partially inhibited by pretreatment of ouabain or in low $K^+(0.5 mM)$ Tyrode's solution. But the attenuation in the $Ca^{2+}-free$ Tyrode's solution was not inhibited. Furthermore this attenuation was completely blocked by pretreatment of djphenhydramine $(H_1-receptor blocker)$ and potentiated by pretreatment of cimetidine $(H_2-receptor\;blocker)$. This attenuation Phenomenon was disappeared after recovery of 1 hour. From the above results, it is suggested that the attenuation phenomenon may be resulted partially from the activation of $Na^+-K^+$ exchange pump and partially from the depletion of intracellular $Ca^{2+}$ pool after the histamine-induced contraction mediated through $H_1-receptor$ function.

  • PDF

Determination of the Unsaturated Hydraulic Conductivity Function (불포화 투수계수함수에 대한 연구)

  • 황창수;김태형
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.3
    • /
    • pp.47-51
    • /
    • 2004
  • An unsaturated hydraulic conductivity function and a soil-water characteristic curve are the essential constitutive factors in studying unsaturated soils. In order to obtain the unsaturated hydraulic conductivity function, prediction functions, which are based on the soil-water characteristic curve, have been used because it is difficult to measure the unsaturated hydraulic conductivity function directly. In this study, a parameter estimation method using the flow pump technique is introduced to determine the unsaturated hydraulic conductivity function. This method provides more accurate and independent solution than previous methods for the determination of the unsaturated hydraulic conductivity function which is not subordinate to the soil-water characteristic curve or prediction models.

Performance Characteristic of the Compression-Absorption Hybrid Heat Pump Cycles (흡수압축 하이브리드 히트펌프 사이클의 성능특성)

  • Yoon J. I.;Kwon O. K.;Yang Y. M.
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.1
    • /
    • pp.14-20
    • /
    • 1999
  • This study describes the results of Coefficient of Performance(COP) analysis by cycle simulation for two types of absorption-compression hybrid cycle using the Water/Lithium Bromide solution pair. These types are basic hybrid systems introducing a mechanical compression process into the refrigerant vapor phase of the single effect absorption cycle. In absorption-compression hybrid cycles, coefficient of performance is improved compared with absorption cycle. Hybrid cycle Type 2 is considered as a key technology to support energy utilization system, given its capability of utilizing waste heat to drive system with a high level of efficiency.

  • PDF