• 제목/요약/키워드: Solution pump

검색결과 283건 처리시간 0.03초

Verification of mechanical failure mode through corrosion test of a pump for soil sterilizer injection

  • Han-Ju Yoo;Jooseon Oh;Sung-Bo Shim
    • 농업과학연구
    • /
    • 제50권4호
    • /
    • pp.817-828
    • /
    • 2023
  • Deteriorating soil physical properties and increasing soil pathogens due to the continuous cultivation of field crops are the leading causes of productivity deterioration. Crop rotation, soil heat treatment, and chemical control are used as pest control methods; however, each has limitations in wide application to domestic agriculture. In particular, chemical control requires improvement due to direct exposure to sterilizing solution, odor, and high-intensity work. To improve the overall domestic agricultural environment, the problems of time and cost, such as field maintenance and cultivation scale, must be addressed; therefore, mechanization technology for chemical control must be secured to derive improvement effects in a short period. Most related studies are focused on the control effect of the DMDS (dimethyl disulfide) sterilizer, and research on the performance of the sterilization spray device has been conducted after its introduction in Korea, but research on the corrosion suitability of the material is lacking. This study conducted a corrosion test to secure the corrosion resistance of a soil sterilizer injection pump, and a mechanical failure mode by corrosion by the material was established. The corrosion test comprised operation and neglect tests in which the sterilizing solution was circulated in the pump and remained in the pump, respectively. As a result of the corrosion test, damage occurred due to the weakening of the mechanical strength of the graphite material, and corrosion resistance to aluminum, stainless steel, fluororubber, and PPS (polyphenylene sulfide) materials was confirmed.

Development of LiFePO4/FePO4 Electrode for Electro-Osmotic Pump using Li+ Migration

  • Baek, Jaewook;Kim, Kyeonghyeon;Shin, Woonsup
    • Journal of Electrochemical Science and Technology
    • /
    • 제9권2호
    • /
    • pp.85-92
    • /
    • 2018
  • Olivine structure of $LiFePO_4$ (LFP) is one of the most commonly used materials in aqueous rechargeable lithium batteries (ARLBs), and can store and release charge through the insertion/de-insertion of $Li^+$ between LFP and FP. We have fabricated LFP and LFP/FP electrodes on titanium paper and studied their electrochemical properties in 2 M $Li_2SO_4$. The LFP/FP electrode was determined to be a suitable electrode for electo-ostmotic pump (EOP) in terms of efficiency in water and 0.5 mM $Li_2SO_4$ solution. Experiments to determine the effect of cations and anions on the performance of EOP using LFP/FP electrode have shown that $Li^+$ is the best cation and that the anion does not significantly affect the performance of the EOP. As the concentration of $Li_2SO_4$ solution was increased, the current increased. The flow rate peaked at $4.8{\mu}L/30s$ in 1.0 mM $Li_2SO_4$ solution and then decreased. When the EOP was tested continuously in 1.0 mM $Li_2SO_4$ solution, the EOP transported approximately 35 mL of fluid while maintaining a stable flow rate and current for 144 h.

관절경 수술을 위한 주입 펌프 시스템 개발 (Development of Irrigation Pump System Used for Arthroscopy Surgery)

  • 이종선;심재원;최주호;차인혁;정영근;안재용
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.1186-1189
    • /
    • 2004
  • A new pump used in arthroscopy surgery was developed. The pump is driven by pneumatic air compressor and controlled by a stepper motor connected to an air regulator. Pressure control performance was observed to be similar compared to commercially available artheroscopy pumps. However, pressure pulses observed in the commercial pumps driven by multiple rollers disappeared in the pneumatically driven pump. The new pump required containers to enclose and squeeze saline solution packs. A dramatic saving in manufacture cost is expected considering the simple pneumatic drive used in this pump.

  • PDF

흡수기 용액 재순환이 흡수식 냉동기 성능에 미치는 영향 (The Influences of LiBr Solution Recirculation in Absorber on the Absorption Chiller Performance)

  • 정종수;진성민;박찬우;최승학;정봉철
    • 대한기계학회논문집B
    • /
    • 제26권5호
    • /
    • pp.733-741
    • /
    • 2002
  • If a part of the poor solution from the absorber outlet is recirculated to the absorber inlet, the solution temperature at the solution spray pump can be reduced, and the solution flow rate in the absorber is increased. We have performed the experiments on the influences of the absorption chiller performance according to the ratio of the recirculation, defined as the ratio of the recirculation flow rate to the total solution flow rate at the absorber outlet. As increasing the ratio of the recirculation, the absorption capacity of the solution can be deteriorated. On the other hand, due to the increasing flow rate, the heat transfer rate can be enhanced. As a result, the performance of the absorber and the cooling capacity of the absorption chiller have nothing to do with the recirculation ratio, and the lifetime of the spray pump will be maintained.

하천수 열원 2단 압축 열펌프시스템의 부분부하 운전특성에 관한 실험적 연구 (An Experimental Study on the Part-Load Performance of a River Water Source 2-Stage Heat Pump)

  • 김지영;백영진;이영수;나호상
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1964-1968
    • /
    • 2007
  • The river water heat source heat pump has the advantage in the performance compared to air source heat pump. Although its better performance, the large temperature difference between load and source makes system performance worse by nature. In this study, 2-stage compression is considered as the solution of this problem. Generally, heat pump is designed for maximum capacity rate, but it actually operates at part load condition in many cases. Therefore, an information on the part-load character is very important in view of the system overall performance. In this study, part-load performance tests of a R134a 2-stage compression heat pump were carried out over the river water and supply heating water temperature changes. The experimental results show that the system performance is influenced by the part load rates, river water temperature, load temperature, etc.

  • PDF

연료공급 장치의 진동 특성에 대한 연구 (A study on the characteristics of vibration in fuel pump system)

  • 권요섭;김찬묵;강태원;사종성;강태식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.494-500
    • /
    • 2007
  • The comfort and quietness of vehicle has been improved greatly due to the development of technology in automobile industry. It is driven by reduction on the level of vibration and noise in powertrain system. However, the hidden problems in automobile parts become noticeable since the vehicle has been better in overall performance. One of them is related to the fuel pump system. Therefore, this study is focused on investigating the characteristics of fuel pump and fuel tank first, and then comparing the data before and after installation of fuel pump system in a testing vehicle. Additionally, the measured data will be analyzed to identify the problems and find a solution to improve the level of noise and vibration in fuel pump system.

  • PDF

GAX 암모니아 흡수식 열폄프의 발생기 일체형 정류기의 열 및 물질전달 해석 (Heat and mass transfer characteristics of generator combined rectification system of the GAX ammonia absorption heat pump)

  • 윤상국
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.431-439
    • /
    • 1999
  • A generator-GAX combined rectification system of an ammonia absorption heat pump was investigated to get the optimum design values. The mass and heat transfer phenomena of the rectification system were analysed. The number of column plates, equilibrium temperature of solution on each plate and flow rates of solution and vapor generated were predicted. The characteristics of mass and heat transfer of the generator-GAX combined rectification system, i.e. concentration difference of leaving solution and vapor on each column plate, were found to be mainly governed by the pressure of generator, reflex ratio and temperature difference of analyser coolant. The number of rectification column plates for each different pressure in generator was obtained. The optimum locations for installing the feeder from solution-cooled absorber and GAX desorber in generator were predicted. The improvement of COP was followed by the increase of the rectifier efficiency and the number of column plate, and the decrease of reflex ratio.

  • PDF

정량펌프를 이용한 무토양재배시스템의 증산량 추정 및 그 응용 (Estimation of Transpiration Rate with a Metering Pump and its Application in Soilless Culture System)

  • 손정익;박종석
    • 원예과학기술지
    • /
    • 제16권1호
    • /
    • pp.25-26
    • /
    • 1998
  • 본 연구는 정량펌프를 이용한 정확한 증산량 추정 시스템의 구축 및 측정된 증산량과 환경요인과의 관계를 분석하는 데 있다. 정량펌프에 의한 양액공급 및 증산량 추정 시스템은 매우 안정적인 특성을 나타냈으며, 증산량 추정을 위하여 재배 시스템에 설치한 정량펌프의 공급시간과 투입량과의 관계는 직선관계를 나타냈다. NFT 및 고형배지 시스템에서의 적산일사량과 증산량을 실측한 결과 증산량은 일사량에 직접적인 영향을 받고 있었으며, NFT는 상관계수 0.98. 고형배지는 상관계수 0.92의 높은 상관관계를 나타내었다. 따라서 정량펌프에 의한 증산량 추정은 양액급액 제어에 효율적인 방법이며, 이러한 방법을 사용하여 적산일사량에 의한 관수량 조절 및 비료투입량의 결정에 적용이 가능하다. 따라서, 측정된 적산일사량에 의하여 증산량 추정이 가능하기 때문에, 정량펌프에 의하여 필요 관수량을 정확한 공급할 수 있다.

  • PDF

제 2종 LiBr-H2O 흡수식 히트펌프의 운전 변수에 따른 성능 특성 수치 해석 (Effects of Operation Conditions on the Performance of Type II LiBr-H2O Absorption Heat Pump)

  • 윤준성;권오경;차동안;배경진;김인관;김민수;박찬우
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.7-14
    • /
    • 2017
  • This study carried out a numerical analysis of the effects of hot waste water supply on the performance of a Type II absorption heat pump. There are two types of hot waste water supply, regular series flow and reverse series flow. Also it investigated the interaction between each type of flow and heat exchange solutions. As the effectiveness of heat exchange solutions increase, the steam generation and (COP) increase as well. If the effectiveness of a heat exchange solution is lower than 0.566, the steam generation rate of the reverse flow is lower than that of the regular series flow. A high effectiveness of heat exchange solution is therefore required to make a larger amount of steam in reverse series flow than with ordinary series flow. The COP difference between the two types of flow decreases with the increasing effectiveness of the heat exchange solution. Thus, a reverse flow type absorption heat pump can match the high steam generation rate and COP of the ordinary flow type when a highly effective heat exchange solution is applied.

공랭형 병렬방식 2중효용 흡수식 냉방시스템의 사이클 해석 (Cycle Analysis of Air-Cooled Double-Effect Absorption Cooling System with Parallel Flow Type)

  • 오명도;김선창;김영인;이홍원
    • 대한기계학회논문집
    • /
    • 제17권8호
    • /
    • pp.2099-2109
    • /
    • 1993
  • A gas-fired 4RT absorption heat pump was designed as an air-conditioner for domestic use during the summer. The absorption heat pump is air-cooled. double-effect, $LiBr-H_{2}O$ system with parallel flow type. The performance of the absorption heat pump in the cooling mode of operation was investigated through cycle modeling and simulation to obtain the system characteristics with parameter changes. System parameters considered in this analysis were the inlet temperature of cooling air to the absorber, the working solution concentrations, the ratio of the amount of the weak solution from the absorber, and the LTD's of each heat exchange component. The optimum designs and operating conditions were determined based on the operating constraints and the coefficient of performance.