• Title/Summary/Keyword: Solution flow

Search Result 3,126, Processing Time 0.03 seconds

Quantitative analysis of cholesterol in infant formula by isotope dilution liquid chromatography-tandem mass spectrometry (동위원소희석 액체크로마토그래피 질량분석법에 의한 분유 내 콜레스테롤의 정량)

  • Ahn, Eun Jeong;Lee, Hwa Shim;Kim, Byung Joo;Lee, Gae Ho
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.460-466
    • /
    • 2015
  • An isotope dilution liquid chromatography tandem mass spectrometry was developed as a primary method for the quantitative analysis of cholesterol in infant formula. Cholesterol-d4 was used as an internal standard and spiked into the infant formula sample. In order to release cholesterol out of cholesteryl ester, which is cholesterol bound to fatty acids in infant formula, saponification was carried out. Saponification conditions were optimized with heating temperature, reaction time and the concentration of KOH. The optimum conditions were as follows; heating temperature was 70 ℃, reaction time was 180 min and the concentration of KOH was 0.8 mL of 8 M KOH for about 0.1 g infant formula sample. Extraction of cholesterol out of sample solution was carried out with hexane uisng liquid-liquid extraction. Chromatographic analysis was carried out using Phenomenex Kinetex C18 column. Mobile phase was 0.1% acetic acid in methanol/water (v/v, 99/1) and flow rate was 0.3 mL/min. Cholesterol and cholesterol-d4 were monitored at mass transfer m/z 369/259 and 373/263 respectively. Reproducibility of the method was evaluated to be 0.23% of the measurement result. The expanded uncertainty of the measurement result of cholesterol in infant formula was approximately 1.9% at a 95% confidence level. NIST standard reference material having certified values of cholesterol in infant formula, was analyzed in order to verify this method. The ID-LC/MS/MS results were well agreed with the certified values of NIST SRM within the uncertainty.

Removal of Phenanthrene by Electrokinetic-Fenton Process in a 2-dimensional Soil System (동전기-펜턴 공정을 이용한 2차원 토양 정화장치에서의 phenanthrene 제거)

  • Park Ji-Yeon;Kim Sang-Joon;Lee You-Jin;Yang Ji-Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.5
    • /
    • pp.11-17
    • /
    • 2005
  • Characteristics of phenanthrene removal in the Electrokinetic (EK)-Fenton process were investigated in a 2-dimensional test cell in a viewpoint of the effect of gravity and electrosmotic flow (EOF). When the constant voltage of 100 V was applied to this system, the current decreased from 1,000 to 290 mA after 28 days, because soil resistance increased due to the exhaustion of ions in soil by electroosmosis and electromigration. Accumulated EOF in two cathode reservoirs was 10.3 L and the EOF rate was kept constant for 28 days. At the end of operation, the concentration of phenanthrene was observed to be very low near the anode and increased in the cathode region because hydrogen peroxide was supplied from anode to cathode region following the direction of EOP. Additionally, the concentration of phenanthrene decreased at the bottom of the test cell because the electrolyte solution containing hydrogen peroxide was largely transported toward the bottom due to a low capillary action in the soil with high porosity. Average removal efficiency of phenanthrene by EK-Fenton process was 81.4% for 28 days. In-situ EK-Fenton process would overcome the limitations of conventional remediation technologies and effectively remediate the contaminated sites.

Analysis of Steady and Unsteady Flow Around a Ship Using a Higher-Order Boundary Element Method (고차경계요소법에 의한 선체주위 유동해석)

  • Sa-Y. Hong;Hang-S. Choi
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.32 no.1
    • /
    • pp.42-57
    • /
    • 1995
  • An efficient and accurate scheme has been constructed by taking advantages of the hi-quadratic spline scheme and the higher-order boundary element method selectively depending on computation domains. Boundary surfaces are represented by 8-node boundary elements to describe curved surfaces of a ship and its neighboring free surface more accurately. The variation of the velocity potential complies with the characteristics of the 8-node element on the body surface. But on the free surface, it is assumed to follow that of the hi-quadratic spline scheme. By which, the free surface solution is free from numerical damping and has better numerical dispersion property. As numerical examples, steady and unsteady Neumann-Kelvin problems are considered. Numerical results for a submerged spheroid, Series 60($C_B=0.6$) and a modified support the proposed method. Finally, a new upstream radiation condition is derived using a wave equation operator in order to deal with problems for subcritical reduced frequency. The relevance of this operator has been confirmed in the case of unsteady Kelvin source potential.

  • PDF

Control of Several Fungi in the Recirculating Hydroponic System by Modified Slow Sand Filtration (재순환 양액재배시 저속 모래여과기 시스템을 이용한 진균류 제어)

  • Park, K.W.;Lee, G.P.;Kim, M.S.;Lee, S.J.;Seo, M.W.
    • Horticultural Science & Technology
    • /
    • v.16 no.3
    • /
    • pp.347-349
    • /
    • 1998
  • Slow sand filtration was modified and applied for the determination of eliminating efficacy of various fungi and for recommending an easy approach to growers. After 1,500 liter filtration, Fusarium oxysporum was eliminated by several substrates such as activated charcoal (92.5% elimination), silica (90.8%), vermiculite (90.5%), sand (82.3%), perlite (50.4%), and hydroball (21.2%). Silica was able to eliminate several fungi by maximal ratio, which was corresponded to Fusarium oxysporum 120 cfu/mL. Collectotrichum lagenarium 98 cfu/mL. Phytophthora capsici 82 cfu/mL, Botrytis cinerea 62 cfu/mL, Pythium spp. 42 cfu/mL, and Sclerotinia ssp. 52 cfu/mL. In this case, the change of EC was minor and pH was maintained to about 7. In deep flow culture of 'Ddooksum Cheokchookmyeon' lettuce and 'Seokwang' tomato, silica-, activated charcoal-, and vermiculite-based filtration system successfully eliminated Fusarium oxysporum and Phytophthora capsici from the nutrient solution. As a result, these plants were not diseased by ten weeks after inoculation. With this system, growers can easily control the root-zone fungi in the recirculating hydroponic system.

  • PDF

A Study on Improvement γ-Reθt Model for Hypersonic Boundary Layer Analysis (극 초음속 경계층 해석을 위한 γ-Reθt모델 개선 연구)

  • Kang, Sunoh;Oh, Sejong;Park, Donghun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.5
    • /
    • pp.323-334
    • /
    • 2020
  • Since boundary layer transition has a significant impact on the aero-thermodynamic performance of hypersonic flight vehicles, capability of accurate prediction of transition location is essential for design and performance analysis. In this study, γ-Reθt model is improved to predict transition of hypersonic boundary layers and validated. A coefficient in the production term of the intermittency transport equation that affects the transition onset location is constructed and applied as a function of Mach number, wall temperature, and freestream stagnation temperature based on the similarity numerical solution of compressible boundary layer. To take into account a Mach number dependency of transition onset momentum thickness Reynolds number and transition length, additional correlation equations are determined as function of Mach number and applied to Reθc and Flength correlations of the baseline model. The suggested model is implemented to a commercial CFD code in consideration of practical use. Analysis of hypersonic flat plate and circular cone boundary layers is carried out by using the model for validation purpose. An improvement of prediction capability with respect to variation of Mach number and unit Reynolds number is identified from the comparison with experimental data.

Measurement of $\textrm{CO}_2$ Concentration and Leaf Area Index for Crop Photosynthesis Model in Sweet Pepper (단고추의 작물 광합성 모델을 위한 $\textrm{CO}_2$ 농도와 엽면적지 수 측정)

  • Lee, Beom-Seon;Chung, Soon-Ju;Jang, Hong-Gi
    • Journal of Bio-Environment Control
    • /
    • v.8 no.3
    • /
    • pp.192-201
    • /
    • 1999
  • This study was aimed to introduce the measurement of $CO_2$ concentration and leaf area index in the phytotron for predicting the effect of CO.E, light and leaf area index on the instantaneous photosynthetic rate of sweet pepper with the existing ASKAM model. Measurements were made in 2 semi-closed phytotron compartments in which three different $CO_2$ concentrations were applied at random. Plants were grown on containers with circulating nutrient solution at 21$^{\circ}C$ and 80-95% relative humidity. The model estimates crop net $CO_2$ uptake for short time intervals during the day based on short-term data of daily radiation, temperature and $CO_2$ concentration. During the photosynthesis measurements, $CO_2$ concentrations in both compartments and in the basement were measured every minute. This was also done for the flow of pure $CO_2$ into the compartment, global radiation, photosynthetic active radiation inside the compartment, temperature and relative humidity. Crop growth models summarize our knowledge on crop behavior and have as such a wide range of applications in analysis, crop management and thus as a farm management tool.

  • PDF

Factors Affecting Foam Separation of Proteins (단백질의 기포분리에 영향을 미치는 요소들에 관한 연구)

  • Lee, Boo-Young;Lee, Cherl-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.220-224
    • /
    • 1987
  • The concentration ranges forming surface excess of bovine serum albumin(BSA) and ovalbumin solutions were determined, and the factors affecting the foam separation of BSA were investigated. The surface tension of BSA solution decreased from 72 to 61 dynelcm, when the concentration changed from $5{\times}10^{-3}$ to $3{\times}10^{-2}%$, and the critical micelle concentration was appeared to be at 0.03% of BSA. At the isoelectric point (pH 4.9) of BSA, the foamate volume was maximum, but enrichment ratio was minimum, resulting in the maximum recovery rate. When the pH deviated from the isoelectric point, the foamate volume decreased and the enrichment ratio increased. The enrichment ratio increased, while the foamate volume decreased drastically as the temperature was elevated above $20^{\circ}C$, resulting in the decrease in recovery rate. As the gas flow rate increased, the enrichment ratio decreased and the foamate volume increased. When $(NH_4)_2SO_4$ was added, the enrichment ratio decreased, but the maximum foamate was obtained at ionic strength 7. The concentration to form the surface excess of ovlbumin, which has lower surface hydrophobicity than BSA, was 200 times higher than that of BSA. This fact indicates the possibility of selective foam separation by hydrophobicity difference of proteins.

  • PDF

Open Heart Surgery for Six Cases of the Conegnital Heart Disease (선천성(先天性) 심장병(心臟病)의 개심술(開心術) -6례(例) 수술경험(手術經驗) -)

  • Lee, Sung Haing;Lee, Sung Koo;Han, Sung Sae;Lee, Kihl Rho;Kim, Song Myung;Lee, Kwang Sook;Lee, Chong Kook
    • Journal of Chest Surgery
    • /
    • v.9 no.2
    • /
    • pp.220-238
    • /
    • 1976
  • Six cases of congenital heart disease were operated on by means of cardiopulmonary bypass between December, 1975 and April, 1976. Two cases of ventricular septal defects (VSD), two cases of VSD, associated with ruptured aneurysm of sinus Valsalva, two cases of atrial septal defects (ASD) and one case of pulmonic stenosis with patent ductus arteriosus were operated. Sarns roller pumps and Bentley Temptrol oxygenators were used for extracorporeal circulation. Pump oxygenator was primed with Ringer's lactate solution, 5% dextrose in water, mannitol, and ACD blood. Flow rate ranged from 2.0 to $2.4L/M^2/min$. Bicarbonate was added to the oxygenator with estimated amount as 15 mEq/L/hr. Venous catheters were introduced into superior and inferior vena cava, and oxygenated blood was returned to the body through aortic cannula inserted into ascending aorta. Moderate hypothermia ($30^{\circ}C$) was induced by core cooling. Aorta was cross clamped for 15 minutes and released for 3 minutes, and repeated clamping when necessary. Atrial and ventricular septal efects were closed by direct sutures. Aneurysms of sinus Valsalva ruptured into the right ventricle were repaired through right ventriculotomy by d:rect closure with Dacron patch reinforcement. Cardiopulmonary bypass time varied from 66 to 209 minutes, and aorta cross clamping time ranged from 13 to 56 minutes. Postoperative bleeding was minimal except one case who needed for evacuation of substernal hematoma. Intra- and postoperative urinary output was satisfactory. Acid-base balance, partial pressure of $O_2$, electrolytes, and hematological changes during intra- and post-perfusion period remained at the acceptable ranges. No mortality was experienced.

  • PDF

A Design of Handoff-aware DiffServ Scheduler in TDD/CDMA Networks (TDD/CDMA망에서 핸드오프를 지원하는 DiffServ 스케줄러 설계)

  • Zang, Seog-Ku;Kim, Young-Han
    • The KIPS Transactions:PartC
    • /
    • v.14C no.6
    • /
    • pp.493-502
    • /
    • 2007
  • In this paper, we propose a handoff-aware DiffServ scheduler which intends to guarantee various QoS requirements of multimedia services for mobile nodes in TDD/CDMA based wireless networks. TDD is widely used duplexing mechanism in wireless communications. Unlike FDD, TDD allows a node to symmetrically communicate with a base station by using a single frequency band, resulting in high utilization of wireless resources. DiffServ is regarded as a relatively simple QoS support mechanism and thus it is easy to be extended. This is because DiffServ is not a per-flow based mechanisms and it does not require any signaling protocol. However, previously proposed DiffServ schedulers for wired networks can not be deployed directly into wireless networks since they do not consider properties of wireless networks. As a solution to the problem, DSS(DiffServ Supporting Scheduler) was proposed. DSS uses uplink channel, which is originally used for a node to require a base station to transmit packets, to support QoS efficiently. However, QoS does not consider handoff so that it can not support QoS for moving nodes from one cell to the other cell. Therefor. the proposed handoff support QoS mechanism is necessary for TCC/CDMA networks. The proposed scheme allows a mobile node to achieve seamless service without QoS degradation even for the handoff duration.

Clinical Experience of Continuous Epidural Analgesia Using Baxter $Infusor^{(R)}$ (Baxter $Infusor^{(R)}$를 이용한 경막외 진통제 지속 주입)

  • Bae, Sang-Chull;Lee, Jang-Won;Kim, Ill-Ho;Song, Hoo-Bin;Park, Wook;Kim, Sung-Yell
    • The Korean Journal of Pain
    • /
    • v.4 no.2
    • /
    • pp.127-132
    • /
    • 1991
  • Recently a non-electronic, disposable and portable infusor(Baxter infusor with patient control module, Baxter health care Co., Deerfield IL 60015 USA: BI $\bar{c}$ PCM) has been developed that will deliver both a continuous drug infusion as well as allow the patient to deliver extra doses of medication on a demand basis under predetermined limitation of analgesics. Patients may also not require as high analgesic dose rate to control pain when the acceptable and tolerable level of pain relief can be maintained by this device. From April l99l, we have used a total l93 units of BI $\bar{c}$ PCM. These units consisting of two components which one made by a balloon reservoir(capacity 65 ml, flow rate 0.5 ml/hr) to store medication and to regulate the pump power(490 torr), and another two PCMs to regulate additional analgesic administration by patients demand at intervals of 1S minutes and 60 minutes. The dose administered to the patient can be varied by changing the concentration of the infusate within the balloon reservoir. These devices were utilized for the pain control of 44 patients. These patients were divided into two groups. Twenty seven cases had cancer pain and 17 cases had non-cancer pain. The Touhy needle(No. l8 G.) tip was inserted into the epidural space and was used to guide the catheter to the spinal nerve level corresponding to the most painful area. The device was connected to the opposite site of the catheter tip and was filled with 60 ml of mixture solution such as 0.5% bupivacaine 15 ml, morphine HCl 10 mg, trazodone 10 ml, Tridol 3 ml and normal saline 31 ml were administed as the initial dose. When the initial dose was less effective, the next dose could be varied by increasing the concentration of bupivacaine, by adding more morphine (5~10 mg), and by reducing the volume of normal saline. Using these modules of drug self administration, we experienced the following: 1) Improvement of patient's self titration of analgesic requirement was provided. 2) The patients anxiety with pain recurrence resulting from delays in administering pain control medication was decreased significantly. 3) The working load accompanying with the single bolus injection as the usual method was reduced remarkably. 4) There was urinary retention in 5 cases and pruritus in 4 eases which developed as side effects but respiratory depression and vomiting was not encountered in a single case.

  • PDF