• 제목/요약/키워드: Solution flow

검색결과 3,133건 처리시간 0.026초

전기화학적 노이즈 저항 측정에서의 불확도 평가 (Uncertainty evaluation in electrochemical noise resistance measurement)

  • 김종집;강수연
    • Corrosion Science and Technology
    • /
    • 제12권5호
    • /
    • pp.220-226
    • /
    • 2013
  • The uncertainty in statistical noise resistance measurement was evaluated for a type 316 stainless steel in NaCl solutions at room temperature. Sensitivity coefficients were determined for measurands or variables such as NaCl concentration, pH, solution temperature, surface roughness, inert gas flow rate and bias potential amplitude. The coefficients were larger for the variables such as NaCl concentration, pH, inert gas flow rate and solution temperature, and they were the major factors increasing the combined standard uncertainty of noise resistance. However, the contribution to the uncertainty in noise resistance measurement from the above variables was remarkably low compared to that from repeated measurements of noise resistance, and thus, it is difficult to lower the uncertainty in noise resistance measurement significantly by lowering the uncertainties related with NaCl concentration, pH, inert gas flow rate and solution temperature. In addition, the uncertainty in noise resistance measurement was high amounting to 17.3 % of the mean, indicating that the reliability in measurement of noise resistance is low.

수평단관 상의 유하액막 열전달 (Falling Film Heat Transfer on a Horizontal Single Tube)

  • 김동관;김무환
    • 설비공학논문집
    • /
    • 제12권7호
    • /
    • pp.642-648
    • /
    • 2000
  • Falling film heat transfer analyses with aqueous lithium bromide solution were peformed to investigate the transfer characteristics of the copper tubes. Finned(knurled) tube and a smooth tube were selected as test specimens. Averaged generation fluxes of water and the heat transfer performances(heat flux, heat transfer coefficient) were obtained. The results of this work were compared with the data reported previously. As the film flow rate of the solution increased, the generation fluxes of water decreased for both tubes. The reason is estimated by the fact that the heat transfer resistance with the film thickness increased as the film flow rate increased. The effect of the enlarged surface area at the knurled tube was supposed to be dominant at a small flow rate. The generation fluxes of water increased with the increasing degree of tube wall superheat. Nucleate boiling is supposed to occur at a wall superheat of 20 K for a smooth tube, and at 10 K for a knurled tube. The heat transfer performance of the falling film was superior to pool boiling at a low wall superheat below 10 K for both tubes tested. The knurled tube geometry showed good performance than the smooth tube, and the increased performance was mainly came from the effect of the increased heating surface area.

  • PDF

미소해칭 전열관의 젖음률에 대한 실험적 상관식 (Experimental Correlation of Wettability for Micro-scale Hatched Tubes)

  • 김진경;박찬우;이경엽;강용태
    • 설비공학논문집
    • /
    • 제15권1호
    • /
    • pp.19-24
    • /
    • 2003
  • The objectives of this paper are to develop a new method of wettability mea-surement and to study the effect of surface roughness on the wettability in a $H_2O$/LiBr falling film absorber. Two absorber tubes with micro-scale roughness and a bare tube are tested in a falling film absorber installed in a test rig. Inlet solution temperature, concentration and mass flow rate are considered as key parameters. A new method is proposed to estimate the wettability of a tube by measuring a minimum mass flow rate to wet the tube completely. The wettability for the structured surfaces was higher than that for the bare tube. The wettability decreased linearly along the vertical location. The wettability increased with increasing the solution temperature and the solution mass flow rate. The experimental correlations of the wettability for the bare and the micro-hatched tubes were developed with error bands of$\pm20%\;and\;\pm10%$, respectively. This work can be used in the design of absorbers with micro-scale roughness.

용액에서의 아미노산 및 단백질 자유기에 관한 ESR 연구 제3보 $Ti-H_2O_2$ Flow System으로 만든 Lysozyme 자유기의 ESR 연구 (An ESR Study of Amino Acid and Protein Free Radicals in Solution Part Ⅲ. ESR Study of Lysozyme Free Radical Produced by $Ti-H_2O_2$ Flow System)

  • 홍순주
    • 대한화학회지
    • /
    • 제15권4호
    • /
    • pp.177-181
    • /
    • 1971
  • Free radicals of lysozyme produced by $Ti-H_2O_2$ system were studied in aqueous solution at room temperature using ESR with a continuous flow-mixing. The spectra, each consisting of a doublet with 5.5 G splitting and a broad resonance covering 80 G splitting are closely similar in shape to that for solid irradiated in vacuum at $77^{\circ}K$ and observed at room temperature immediately on warming. The result is assumed to indicate that the secondary protein radical components formed within 0.01 second, dead time of the mixing chamber, and initiated by hydrogen atom abstraction at ${\alpha}$-carbon atom of peptide chain in liquid solution at room temperature are identical to those resulting from the initial formation of a mixture of positive holes and negative ions by ionization processes as well as radical fragments by the rupture of chemical bonds in the solid during similar time at the same temperature. A broad resonance is observed with considerable amplitude on the high field side of the doublet, which is quite dissimilar to the spectra of irradiated solid lysozyme. This resonance was tentatively attributed to the polypeptide free radical in which unpaired electrons are localized on side chain.

  • PDF

SOFC용 복합 배기 시스템 유동 특성에 관한 실험 및 수치해석적 연구 (Experimental and Numerical Study on Flow Characteristics of a Common Exhaust System for Multiple SOFCs)

  • 정대웅;윤종혁;송형운
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.657-666
    • /
    • 2023
  • In this study, experiments and numerical analysis were conducted to investigate the exhaust gas flow in a common exhaust system of multiple solid oxide fuel cells. The system was fabricated based on KGS code and operated within a pressure range of 0.12 kPa, with flow rates ranging from 79.1 to 103.4 L/min. Numerical modeling was validated with a mean absolute error of 3.8% for pressure results. The study assessed the impact of changes in area ratio and emergency stops on pressure distribution, velocity vectors, and wall shear stress. The findings revealed no significant factors causing high differential pressure or backflow.

전산유체역학을 활용한 마찰교반용접의 해석적 접근에서 표면추적을 위한 알고리즘 연구 (A study on an Interface Tracking Algorithm in Friction Stir Welding based on Computational Fluid Dynamics Analysis)

  • 김수덕;나석주
    • Journal of Welding and Joining
    • /
    • 제34권3호
    • /
    • pp.12-16
    • /
    • 2016
  • Friction stir welding(FSW) was studied using commercial tool, FLOW-3D. The purpose of this study is to suggest a method to apply frictional heat in Computational fluid dynamics(CFD) analysis. Cylindrical tool shape was used, and the interface cells between tool surface and workpiece were tracked by its geometrical relations in order to consider the frictional heat in FSW. After tracking the interface cells, average area concept was used to calculate the frictional heat, which is related to interface area. Also three-dimensional heat source and visco-plastic flow were modeled. The frictional heat generation rate calculated numerically from the suggested algorithm was validated with the analytical solution. The numerical solution was well matched with the analytical solution, and the maximum percentage of error was around 3%.

NUMERICAL SIMULATION OF PLASTIC FLOW BY FINITE ELEMENT LIMIT ANALYSIS

  • Hoon-Huh;Yang, Wei-H.
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1992년도 춘계학술대회 논문집 92
    • /
    • pp.159-176
    • /
    • 1992
  • Limit analysis has been rendered versatile in many problems such as structural problems and metal forming problems. In metal forming analysis, a slip-line method and an upper bound method approach to limit solutions is considered as the most challenging areas. In the present work, a general algorithm for limit solutions of plastic flow is developed with the use of finite element limit analysis. The algorithm deals with a generalized Holder inequality, a duality theorem, and a combined smoothing and successive approximation in addition to a general procedure for finite element analysis. The algorithm is robust such that from any initial trial solution, the first iteration falls into a convex set which contains the exact solution(s) of the problem. The idea of the algorithm for limit solution is extended from rigid/perfectly-plastic materials to work-hardening materials by the nature of the limit formulation, which is also robust with numerically stable convergence and highly efficient computing time.

  • PDF

Job shop에서 평균처리시간 최소화를 위한 할당 규칙

  • 전태준;박성호
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 1996년도 춘계공동학술대회논문집; 공군사관학교, 청주; 26-27 Apr. 1996
    • /
    • pp.310-313
    • /
    • 1996
  • Mathematical programming method for finding optimal solution of job shop scheduling is inadequate to real situation because fo too much computation time. In contrast, dispatching rule is helpful for reducing compuation time but is not guaranted to find optimal solution. The purpose of this paper is to develop a new dispatching rule and procedure to minimize mean flow time whose result is near the optimal solution for job shop scheduling. First step is to select machine which have shortest finishing operation time among the schedulable operations. Second step is to select operation with regard to estimated remaining operation time. The suggested rule is compared with nondelay and MWKR rule for three examples, and is confirmed to be most effective to minimize mean flow time.

  • PDF

A BOUNDARY CONTROL PROBLEM FOR THE TIME-DEPENDENT 2D NAVIER-STOKES EQUATIONS

  • Kim, Hongchul;Kim, Seon-Gyu
    • Korean Journal of Mathematics
    • /
    • 제16권1호
    • /
    • pp.57-84
    • /
    • 2008
  • In this paper, a boundary control problem for a flow governed by the time-dependent two dimensional Navier-Stokes equations is considered. We derive a mathematical formulation and a relevant process for an appropriate control along the part of the boundary to minimize the drag due to the flow. After showing the existence of an optimal solution, the first order optimality conditions are derived. The strict differentiability of the state solution in regard to the control parameter shall be exposed rigorously, and the necessary conditions along with the system for the optimal solution shall be deduced in conjunction with the evaluation of the first order Gateaux derivative to the performance functional.

  • PDF

역전 유동층에 의한 슬러리아이스 생성에 관한 연구 (A study on formation of slurry ice by the reversing flow)

  • 오철;문성배;최영규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권3호
    • /
    • pp.376-381
    • /
    • 2006
  • This study is experimented to observe an influence of experimental conditions on production characteristics of slurry ice by putting ball into test section to disturb ice adhesion. And at this experiment it used ethylene glycol-water solution and the concentration is 20wt%. The experimental apparatus was constructed of ethylene glycol-water solution and slurry ice storage tank. brine tank, pumps for ethylene glycol-water solution and brine circulating, a mass flow-meter data logger for fluid temperature measuring and a vertical circular tube with two copper tubes as test section. The experiments were carried out under various conditions, with mean velocity of fluid at the entry ranging from 0.07 to 0.13m/s and ball diameter is 10mm, 15mm. Also ball filling rate is 33%, 50%.