• 제목/요약/키워드: Solution flow

검색결과 3,119건 처리시간 0.029초

천연가스배관내 피그흐름의 동적모델링 (Dynamic Modeling of PIG Flow in Natural Gas Pipelines)

  • 김상봉;쿠엔탄티엔;유휘룡;노용우
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.241-246
    • /
    • 2001
  • This paper introduces modeling and solution for the dynamics of pipeline inspection gauge (PIG) flow in natural gas pipeline. Without of bypass flow, the dynamic behavior of the PIG depends on the different pressure between the rear and nose parts, which is generated by injected gas flow behind the tail of the PIG and expelled gas flow in front of its nose. With bypass flow, the PIG dynamics also depends on the amount of bypass flow across its body. The mathematical model are derived for unsteady compressible flow of the PIG driving and expelled gas, and for dynamics of the PIG. The bypass flow is assumed to be incompressible with the condition of its Mach number smaller than 0.45. The method of characteristic (MOC) and the Runge-Kutta method are used to solve the system governing equations. The simulation is performed with a pipeline segment in the Korea Gas Corporation (KOGAS) low pressure system, Ueijungboo-Sangye line. The simulation results show that the derived mathematical model and the proposed solution are effective for estimation the dynamics of the PIG with and without bypass flow under given operational condition.

  • PDF

리튬브로마이드 수용액 유하액막의 흡수과정에 대한 근사 해법 : 증기 유동의 영향 (Approximate solutions on the absorption process of an aqueous LiBr falling film : effects of vapor flow)

  • 김병주;이찬우
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.144-152
    • /
    • 1997
  • Film absorption involves simultaneous heat and mass transfer in the vapor-liquid system. In the present work, the absorption process of water vapor by an aqueous soluton of LiBr flowing inside of the vertical tube was investigated. The continuity, momentum, energy and diffusion equations for the solution film and vapor were formulated in integral forms and solved numerically. The model could predict the film thickness, the pressure gradient, and the heat and mass transfer rate. Particularly the effects of vapor flow conditions on the absorption process were investigated in terms of the vapor Reynolds number. As the vapor Reynolds number increased, the shear stress at the vapor-solution interface also increased. Consequently solution film became thinner at higher vapor flowrate under the co-currentflow condition. Thinner film was capable of higher heat transfer to the wall and leaded to higher absorption rate of the water vapor into the solution film.

  • PDF

전해수를 이용한 견섬유 정련 및 세리신 회수(II)-분리막에 의한 세리신 농축을 중심으로- (The Degumming and Sericin Recovery of the Silk fabric Using the Electrolytic Water(II))

  • 배기서;이태상;노덕길;홍영기
    • 한국염색가공학회지
    • /
    • 제16권4호
    • /
    • pp.10-18
    • /
    • 2004
  • In this work, Aqueous sericin solution was prepared by degumming process with electrolytic reduction water. Then, the microfiltration and ultrafiltration systems were applied to the concentration of aqueous sericin solution. The objective of this study was to select the optimum operating condition among the different pressure. The permeate flux and rejection ratio were observed with time, pressure, flow rate and concentration. and, the wastewater and permeated water quality values such as pH, BOD, COD, and NH levels were measured. In order to see the influence of electrolytic reduction water, the flux of pure water and electrolytic reduction water by PVDF22(MF) and PS100(UF) membrane was measured. In microfiltration system, the relative flux reduction decreased rapidly to 0.02 in the 30min, as the concentration polarization and gel layer formation were increased. and then the sericin concentration rejection ratio was 40%. In ultrafiltration system, the permeate flux decreased with time and concentration, and increased with the operating pressure and flow rate. Optimal condition in PS100 membrane system for sericin concentration was operating pressure 1.464kgf/$cm^24, operating flow rate $7\ell/min at\; 40^{\circ}C$. At that time, sericin concentration rejection ratio was 83% respectably. The sericin solution was concentrated from 0.1wt% solution to 0.2 wt % solution during about 2 hrs by the UF filteration membrane system.

시멘트 페이스트의 슬럼프 유동 모사를 위한 분석적 해의 검토 (Review on Analytical Solutions for Slump Flow of Cement Paste)

  • 윤태영
    • 한국도로학회논문집
    • /
    • 제18권3호
    • /
    • pp.21-32
    • /
    • 2016
  • PURPOSES : In this paper, the analytical solutions suggested to simulate the behavior of rheological fluids were rigorously re-derived and investigated for fixed conditions to evaluate the applicability for the solutions on a mini-cone slump test of cement paste. The selected solutions with proper boundary conditions can be used as reference solutions to evaluate the performance of numerical simulation approaches, such as the discrete element method. METHODS : The slump, height, and spread radius for the given boundary and yield stress conditions that are determined by five different analytical solutions are compared. RESULTS : The analytical solution based on fluid mechanics for pure shear flow shows similar results to that for intermediate flow at low yield stresses. The fluid mechanics-based analytical solution resulted in a very similar trend to the geometry-based analytical solution. However, it showed a higher slump at high yield stress and lower slump at low yield stress ranges than the geometry-based analytical model. The analytical solution based on the mini-cone geometry was not significantly affected by the yield criteria, such as von Mises and Tresca. CONCLUSIONS : Even though differences among the analytical solutions in terms of slump and spread radius existed, the difference can be considered insignificant when the solutions were used as reference to evaluate the appropriateness of numerical approaches, such as the discrete element method.

H2O/LiBr+HO(CH2)3OH계 공냉형 이중효용 흡수식 냉방시스템의 사이클 해석 (Cycle Analysis of Air-Cooled Double-Effect Absorption Cooling System Using H2O/LiBr+HO(CH2)3OH)

  • 권오경;문춘근;윤정인
    • 대한기계학회논문집B
    • /
    • 제23권2호
    • /
    • pp.272-280
    • /
    • 1999
  • A cycle analysis was achieved to predict the characteristics by comprehensive modeling and simulation of an air-cooled, double-effect absorption system using a new $H_2O/LiBr+HO(CH_2)_3OH$ solution. The simulation results showed that the new working fluid may provide the crystallization limit 8% higher than the conventional $H_2O/LiBr$ solution. With a crystallization margin of 3wt%(weight%), the optimal solution distribution ratio was found in the range of 36 to 40%. Variation of cooling air Inlet temperature has a sensitive effect on the cooling COP and corrosion problem. The simulation of heat exchangers with UA value revealed that the absorber and the evaporator are relatively important for an air-cooled system compared with the condenser and the low temperature generator. The effect of cooling air flow rate, circulation weak solution flow rate and chilled water inlet temperature were also examined. The new working fluid may provide the COP approximately 5% higher than the conventional $H_2O/LiBr$ solution.

태양열 이용 냉난방 공조시스템 중 전열교환기의 최적운전조건에 관한 연구 (Research on the Optimal Operating Condition of a Total Heat Exchanger in Solar Air-Conditioning System)

  • 김광호;최광환;금종수;김보철;김동규
    • 태양에너지
    • /
    • 제19권4호
    • /
    • pp.55-62
    • /
    • 1999
  • This study was performed to find out the influence of experimental factors on dehumidification performance and furthermore to suggest an optimal combination of factors of a total heat exchanger in a solar air conditioning system. The experimental apparatus was set up in a climate-controlled chamber where the temperature and humidity was maintained constant. In order to find out the contribution ratio of factors on dehumidification performance, the table of orthogonal arrays $L_8(2^7)$ was used. According to the results, the most influential factor on dehumidification performance was the concentration of LiCl(Lithium Chloride) solution. The next influential factors were the temperature of LiCl solution and the air flow rate. The packed layer height, packed material, and flow rate of LiCl solution had no influence on the dehumidification performance under these experimental conditions. Through the three level experiments of $L_{27}(3^{13})$, it was found that the optimal combination was $A_2B_0G_2$(concentration of solution 30 wt%, temperature of solution $15^{\circ}C$, air flow rate $253m^3/h$).

  • PDF

직교격자상에서 효율적인 비압축성 자유표면유동 해법 (AN EFFICIENT ALGORITHM FOR INCOMPRESSIBLE FREE SURFACE FLOW ON CARTESIAN MESHES)

  • 고광수;안형택
    • 한국전산유체공학회지
    • /
    • 제19권4호
    • /
    • pp.20-28
    • /
    • 2014
  • An efficient solution algorithm for simulating free surface problem is presented. Navier-Stokes equations for variable density incompressible flow are employed as the governing equation on Cartesian meshes. In order to describe the free surface motion efficiently, VOF(Volume Of Fluid) method utilizing THINC(Tangent of Hyperbola for Interface Capturing) scheme is employed. The most time-consuming part of the current free surface flow simulations is the solution step of the linear system, derived by the pressure Poisson equation. To solve a pressure Poisson equation efficiently, the PCG(Preconditioned Conjugate Gradient) method is utilized. This study showed that the proper application of the preconditioner is the key for the efficient solution of the free surface flow when its pressure Poisson equation is solved by the CG method. To demonstrate the efficiency of the current approach, we compared the convergence histories of different algorithms for solving the pressure Poisson equation.

관상동맥 우회로술에서 내유동맥 이식편의 처치방법에 따른 문합전 내유동맥 혈류량의 비교 (Preparation of the Internal Mammary Artery Graft in Coronary Artery Bypass Surgery - Comparison of Free Mammary Artery Flows -)

  • 최종범;김형곤;정진원
    • Journal of Chest Surgery
    • /
    • 제26권2호
    • /
    • pp.148-153
    • /
    • 1993
  • To compare two methods of mammary pedicle graft preparations with free internal mammary artery flow, we studied 31 patients who had the left internal mammary artery harvested for coronary artery bypass grafting. The free flow was measured at the transected opening of 2 to 3 cm distal to the point of bifurcation on mean arterial pressure of 50 to 55 mmHg during cardiopulmonary bypass. Group I comprised 14 patients, whose grafts were sprayed and wrapped in sponges soaked in diluted papaverine solution (60 mg in 40 ml Hartmann's solution). An average 80 minutes after the preparations, free flow of the internal mammary artery ranged from 20 to 80 ml/min (mean 37.7 ml/min). Group II comprised 17 patients, who had internal mammary artery takedown under the exact conditions used in group I. The grafts were sprayed and wrapped in sponges soaked in the diluted papaverine solution as in group I. After an average of 28 minutes, free flow ranged from 8 to 28 ml/min (mean 17.6 ml/min). Intraluminal papaverine of the same dilution was then injected without any hydrostatic dilatation and flows increased upto 37 to 150 ml/min (mean 74.7 ml/min). This study shows that intraluminal papaverine preparation method markedly increases free mammary artery flow which is inadequate with external papaverine preparation.

  • PDF

The effect of rotation on the macro-steps formation during 4H-SiC solution growth

  • Shin, Yun-Ji;Park, Tae-Yong;Bae, Si-Young;Jeong, Seong-Min
    • 한국결정성장학회지
    • /
    • 제29권6호
    • /
    • pp.294-297
    • /
    • 2019
  • New insights about macro-step formation has been investigated. The phenomena of surface instability caused by the interaction between step flow and fluid flow was describe in mechanical way. The rotation of the seed crystal in a clockwise direction was applied with a speed varied from 30 to 200 rpm during the TSSG process on the Si- and C-faces 4H-SiC. The macro-steps were formed along the two specific directions at different locations on the crystal for each, i.e., [10-10] or [01-10] directions or both. From the results, it is suggested that the macro-steps were generated from the micro-steps by interaction between step flow and fluid flow during the rotation of seed crystal. Furthermore, The fluid flow could be effective to control the micro- and/or macro-step behavior during solution growth.

저점성 SWNT 분산액 도포용 슬릿 노즐 설계를 위한 유동해석 (A STUDY ON FLOW IN A SLIT NOZZLE FOR DISPENSING A LOW-VISCOSITY SOLUTION OF SINGLE-WALLED CARBON NANOTUBES)

  • 손병철;곽호상;이상현
    • 한국전산유체공학회지
    • /
    • 제14권1호
    • /
    • pp.78-85
    • /
    • 2009
  • A combined theoretical and numerical study is conducted to design a slit nozzle for large-area liquid coating. The objectives are to guarantee the uniformity in the injected flow and to provide the capability of explicit control of flow rate. The woking fluid is a dilute aqueous solution containing single-walled carbon nanotubes and its low viscosity and the presence of dispersed materials pose technical hurdles. A theoretical analysis leads to a guideline for the geometric design of a slit nozzle. The CFD-based numerical experiment is employed as a verification tool. A new flow passage unit, connected to the nozzle chamber, is proposed to permit the control of flow rate by using the commodity pressurizer. The numerical results confirm the feasibility of this idea. The optimal geometry of internal structure of the nozzle has been searched for numerically and the related issues are discussed.