• Title/Summary/Keyword: Solution Plasma

Search Result 735, Processing Time 0.031 seconds

Preparation of Ultrafine $SnO_2$ Powders by Spray-ICP Technique

  • Kim, Jung-Hwan;Kim, Young-Do;Shin, Kun-Chul;Park, Jong-Hyun
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1998.06a
    • /
    • pp.65-70
    • /
    • 1998
  • The Spray-ICP technique uses the ICP(Inductively Coupled Plasma) of ultra-high temperature which is produced by r.f power. The ICP is well-kwown as a clean heat source for the preparation of pure ceramic particles because the ICP is a electrodeless-thermal plasma without contamination. In this study,{{{{ { SnO}_{2 } }}}} particles were sythesized from metal salt solution by Spray-ICP technique. The effects of concentration of solution, collecting location of powders were investicated. The prepared {{{{ { SnO}_{2 } }}}} particles from each concentration of solution had same crystalline phase(tetragonal {{{{ { SnO}_{2 } }}}}) a nd the mean size decreased in proportion to the increase of solution concentration. Each {{{{ { SnO}_{2 } }}}} p owders collector in reactor and electrostatic collector had same crystalline phase and morphologies. The mean size of {{{{ { SnO}_{2 } }}}} p articles prepared by Spray-ICP technique was below 30nm.

  • PDF

Effect of HF and Plasma Treated Glass Surface on Vapor Phase-Polymerized Poly(3,4-ethylenedioxythiophene) Thin Film : Part II

  • Lee, Joonwoo;Kim, Sungsoo
    • Journal of Integrative Natural Science
    • /
    • v.6 no.4
    • /
    • pp.215-219
    • /
    • 2013
  • In this study, in order to investigate how consecutive treatments of glass surface with HF acid and water vapor/Ar plasma affect the quality of 3-aminopropyltriethoxysilane self-assembled monolayer (APS-SAM), poly(3,4-ethylenedioxythiophene) (PEDOT) thin films were vapor phase-polymerized immediately after spin coating of FeCl3 and poly-urethane diol-mixed oxidant solution on the monolayer surfaces prepared at various treatment conditions. For the film characterization, various poweful tools were used, e.g., FE-SEM, an optical microscope, four point probe, and a contact angle analyzer. The characterization revealed that a well prepared APS-SAM on a glass surface treated with water vapor/Ar plasma is very useful for uniform coating of FeCl3 and DUDO mixed oxidant solution, regardless of HF treatment. On the other hand, a bare glass surface without APS-SAM but treated with HF and water vapor/Ar plasma generally led to a very poor oxidant film. As a result, PEDOT films vapor phase-polymerized on APS-SAM surfaces are far superior to those on bare glass surfaces in the quality and electrical characteristics aspects.

Effect of Plasma Polymerization Coating of CNTs on the Tensile Strength of Pei/Cnt Composites

  • Song, K.C.;Yoon, T.H.
    • Journal of Adhesion and Interface
    • /
    • v.6 no.4
    • /
    • pp.7-11
    • /
    • 2005
  • Multi-walled carbon nanotubes (CNTs), which were purified by etching in 25% $H_2SO_4/HNO_3$ solution at $60^{\circ}C$ for 2 h, were modified via plasma polymerization coating of acrylic acid, allylamine or acetylene, and then utilized to prepare PEI/CNT composites. First, plasma polymerization conditions were optimized by measuring the solvent resistance of coatings in THF, chloroform and NMP, and the tensile strength of PEI/CNT (0.5%) composites as a function of plasma power (20~50 W) and monomer pressure (20~50 mTorr). The tensile strength of PEI/CNT composites was further evaluated as a function of CNT loading (0.2, 0.5 and 1%). Finally, FT-IR was utilized to provide a better understanding of the improved tensile properties of PEI/CNT composites via plasma polymerization coating of CNTs. Plasma polymerization of acrylic acid greatly enhanced the tensile strength of PEI/CNT composites, as did allylamine but to a lesser degree, while acetylene plasma polymerization coating decreased tensile strength.

  • PDF

Studies on the Pharmacodynamic Action of Methemoglobin (Methemoglobind의 약력학적(藥力學的) 작용(作用)에 관(關)한 연구(硏究))

  • Kim, Kwang-Yun
    • The Korean Journal of Pharmacology
    • /
    • v.2 no.1 s.2
    • /
    • pp.49-69
    • /
    • 1966
  • For the purpose of stydying the pharmacodynamic action of methemoglobin, the author made the following experiments: 1. Preparation of hemoglobin and methemoglobin solutions: Red cell suspension from rabbit blood was hemolysed with distilled water and then divided into two portions. One portion was dialysed through cellophane paper and made isotonic with the proper amount of sodium chloride. The second portion was treated with sodium nitrite to convert hemoglobin to methemoglobin, dialysed through cellophane paper and made isotonic. 2. The concentration of methemoglobin in solution, plasma and urine was determined by Horecker and Brackette's method, and that of hemoglobin by the cyanmethemoglobin method. 3. The concentration of methemoglobin and hemoglobin in the plasma and urine of rabbits was measured at several intervals of time after infusion of the above samples. 4. The blood pressure and respiration of rabbits were recorded on a kymograph, and the effects of the samples on them were observed. 5. The effects of the samples on the movements of the in-situ heart and the isolated intestine of rabbits were studied. 6. The kidneys of rabbits were excised 4 to 5 hours after injection of the samples, and histopathological examinations were made. These experiments revealed the following results: 1. When methemoglobin solution was allowed to stand in room air, there was no decrease in the concentration of methemoglobin. 2. When methemoglobin solution was mixed with whole blood and incubated at $37^{\circ}C$, the concentration of methemoglobin decteased gradually. 3. After the infusion of methemoglobin and hemoglobin solutions, the rate of disappearance of methemoglobin in the plasma was more rapid than that of hemoglobin in the plasma. The higher the initial concentration in the plasma, the larger was the rate of disappearance of methemoglobin. 4. The rate of disappearance of methemoglobin was exceedingly rapid for 30 minutes after the infusion. 5. The urinary excretion of methemoglobin was more rapid than that of hemoglobin. 6. It would seem that the circulating blood contains substances which are promptly mobilized in the plasma to reduce methemoglobin to hemoglobin. 7. Moderate amounts of methemoglobin solution caused some rise in the blood pressure and a transient acceleration of the respiration of the rabbits. These effects of methemoglobin were milder than those of hemoglobin. 8. The movements of the in-situ heart and the isolated intestine of rabbits were accelerated by methemoglobin. These accelerating effects were milder than those of hemoglobin. 9. In the kidneys of rabbits treated with methemoglobin solution, hyperemia of the glomeruli, cloudy swelling and hemoglobin deposit in the tubular epithelium, hemoglobin casts in the tubular lumina of the proximal tubules, and interstitial congestion were constantly observed. There was no definite difference between the histological findings in the rabbit kidneys injected with methemoglobin, and those injected with hemoglobin solutions.

  • PDF

Plasma Phosphoproteome and Differential Plasma Phosphoproteins with Opisthorchis Viverrini-Related Cholangiocarcinoma

  • Kotawong, Kanawut;Thitapakorn, Veerachai;Roytrakul, Sittiruk;Phaonakrop, Narumon;Viyanant, Vithoon;Na-Bangchang, Kesara
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.1011-1018
    • /
    • 2015
  • This study was conducted to investigate the plasma phosphoproteome and differential plasma phosphoproteins in cases of of Opisthorchis viverrini (OV)-related cholangiocarcinoma (CCA). Plasma phosphoproteomes from CCA patients (10) and non-CCA subjects (5 each for healthy subjects and OV infection) were investigated using gel-based and solution-based LC-MS/MS. Phosphoproteins in plasma samples were enriched and analyzed by LC-MS/MS. STRAP, PANTHER, iPath, and MeV programs were applied for the identification of their functions, signaling and metabolic pathways; and for the discrimination of potential biomarkers in CCA patients and non-CCA subjects, respectively. A total of 90 and 60 plasma phosphoproteins were identified by gel-based and solution-based LC-MS/MS, respectively. Most of the phosphoproteins were cytosol proteins which play roles in several cellular processes, signaling pathways, and metabolic pathways (STRAP, PANTHER, and iPath analysis). The absence of serine/arginine repetitive matrix protein 3 (A6NNA2), tubulin tyrosine ligase-like family, member 6, and biorientation of chromosomes in cell division protein 1-like (Q8NFC6) in plasma phosphoprotein were identified as potential biomarkers for the differentiation of healthy subjects from patients with CCA and OV infection. To differentiate CCA from OV infection, the absence of both serine/threonine-protein phosphatase 2A 56 kDa regulatory subunit beta isoform and coiled-coil domain-containing protein 126 precursor (Q96EE4) were then applied. A combination of 5 phosphoproteins may new alternative choices for CCA diagnosis.

Effects of OH Radical Density from Atmospheric Plasma to Induce Cell Death in Lung Cancer and Normal Cells

  • Park, Dae-Hun;Kim, Yong-Hui;Sim, Geon-Bo;Baek, Gu-Yeon;Eom, Hwan-Seop;Choe, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.254.1-254.1
    • /
    • 2014
  • Atmospheric plasma's electron temperature is less than thermal plasma, so it is useful at bio experiment. We have investigated the optical emission spectroscopy (OES) lines by spectrometer during Atmospheric plasma bombardment onto the PBS surface by using an Ar gas flow. Also we have measured the OH radical density inside the solution induced by the Atmospheric plasma bombardment. OH radical species are appeared at 308 nm and 309 nm. Densities of OH radical species has been found to be significantly decreased versus depth of the solution from 2 mm to 6 mm. OH radical density inside the PBS is measured to be about $1.87{\times}1016cm-3$ downstream at 2 mm from the surface under optimized Ar gas flow of 200 sccm in Atmospheric plasma. Also we have investigated cell viability of lung cancer and normal cell after Atmospheric plasma treatment for fixed exposure time in 60 seconds, but different depths. We used SEM, we observed change of cell morphorogy, did experiment about FDA & PI Staining method. It is found that there is selectivity between the lung cancer and lung normal cell, in which cancer cell definitely has higher cell death ratio more than normal cell. We have investigated change of bond structure in FT-IR spectroscopy, the following peaks were observed: and intense O-H peak at 3422 cm-1 and at 2925 cm-1 corresponds to C-H stretch vibrations of methylene group.

  • PDF

Breakdown Properties in Physiological Saline by High Voltage Pulse Generator

  • Byeon, Yong-Seong;Song, Ki-Baek;Uhm, Han-Sup;Shin, Hee-M.;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.333-333
    • /
    • 2011
  • We have investigated the breakdown properties in liquids by high voltage pulse system. High voltage pulse power system is consisted of the Marx-generator with two capacitors (0.5 ${\mu}F$, withstanding voltage is 40 kV), to which the charging voltage can be applied to maximum 30 kV DC, spark gap switch and charging resistor of 20 $M{\Omega}$. We have made use of tungsten pin electrodes of anode-cathode (A-K), which are immersed into the liquids. The breakdown voltage and current signals are measured by high voltage probe (Tektronix P6015A) and current monitor (IPC CM-1.S). Especially the high speed breakdown or plasma propagation characteristics in the pulsed A-K gap have been investigated by using the high speed ICCD camera. We have measured the electron temperature through the Boltzmann plot method from the breakdown spectrums. Here the A-K gap has been changed by 1 mm, 2 mm, and 3 mm. The used liquids are distilled water and solution of salt (0.9 %). The output voltage and current signals at breakdown in distilled water are shown to be bigger than those in saline solution. The breakdown voltage and current characteristics in liquids will be discussed in accordance with A-K gap distances. It is also found that the electron temperatures and plasma densities in liquids are decreased in conformity with A-K gap.

  • PDF

Decomposition of Aqueous Anatoxin-a Using Underwater Dielectric Barrier Discharge Plasma Created in a Porous Ceramic Tube (다공성 세라믹관내에서 생성되는 수중 유전체 장벽 방전 플라즈마를 이용한 아나톡신-a의 분해)

  • JO, Jin-Oh;Jwa, Eunjin;Mok, Young-Sun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.2
    • /
    • pp.167-177
    • /
    • 2016
  • This work investigated the decomposition of aqueous anatoxin-a originated from cyanobacteria using an underwater dielectric barrier discharge plasma system based on a porous ceramic tube and an alternating current (AC) high voltage. Plasmatic gas generated inside the porous ceramic tube was uniformly dispersed in the form of numerous bubbles into the aqueous solution through the micro-pores of the ceramic tube, which allowed an effective contact between the plasmatic gas and the aqueous anatoxin-a solution. Effect of applied voltage, treatment time and the coexistence of nutrients such as $NO_3{^-}$, $H_2PO_4{^-}$ and glucose on the decomposition of anatoxin-a was examined. Chemical analyses of the plasma-treated anatoxin-a solution using liquid chromatography-mass spectrometry (LC-MS) and ion chromatography (IC) were performed to elucidate the mineralization mechanisms. Increasing the voltage improved the anatoxin-a decomposition efficiency due to the increased discharge power, but the energy required to remove a given amount of anatoxin-a was similar, regardless of the voltage. At an applied voltage of 17.2 kV (oxygen flow rate: $1.0L\;min^{-1}$), anatoxin-a at an initial concentration of $1mg\;L^{-1}$ (volume: 0.5 L) was successfully treated within 3 min. The chemical analyses using LC-MS and IC suggested that the intermediates with molecular weights of 123~161 produced by the attack of plasma-induced reactive species on anatoxin-a molecule were further oxidized to stable compounds such as acetic acid, formic acid and oxalic acid.

2D Kinetic Simulation of Partially Magnetized Capacitively Coupled Plasma Sources (2차원 동역학 시뮬레이션을 활용한 부분적으로 자화된 용량성 결합 플라즈마 전산 모사)

  • Sung Hyun Son;Junbeom Park;Kyoung-Jae Chung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.1
    • /
    • pp.118-123
    • /
    • 2023
  • Partially magnetized capacitively coupled plasma (CCP) sources are investigated using a two-dimensional kinetic simulation code named EDIPIC-2D. A converging numerical solution was obtained for CCP with a 60 MHz power source, while properly capturing the dynamics of electrons and power absorption over a single RF period. The effects of magnetic fields with different orientations were evaluated. Axial magnetic fields caused changes in the spatial distribution of plasma density, affecting the loss channel. Transverse magnetic fields enhanced stochastic heating near the powered electrode, leading to an increase in plasma density while the significant E×B drift loss compensated for this rise.

  • PDF

Study on Corrosion Resistance Performance of Zn Coating Applied by Arc Thermal and Plasma Arc Spray Process in Artificial Ocean Water (인공해양환경에서 Arc Thermal and Plasma Arc Spray 공법이 적용된 Zn 코팅 강재의 내식성능 평가에 관한 연구)

  • Jannat, Adnin Raihana;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.83-84
    • /
    • 2020
  • In present study, we have deposited the Zinc coating using arc thermal spray and plasma arc spray processes onto the steel substrate and durability of the deposited coating was evaluated. The bond adhesion result shows that plasma arc sprayed Zn coating exhibited higher in its value compared to arc thermal spray. SEM shows that Zn coating deposited by plasma arc process is more compact, less porous and adherent compare to arc spray process. The corrosion resistance properties are evaluated in artificial ocean water solution with exposure periods. EIS results show that total impedance at 0.01 Hz of plasma arc sprayed coating is higher than arc thermal spray owing to the compact and less porous morphology. It is concluded that plasma arc sprayed Zn coating is better than arc thermal spray process.

  • PDF