• Title/Summary/Keyword: Solid separation efficiency

Search Result 119, Processing Time 0.021 seconds

Turbidity Treatment of TiO2 Wastewater by Electrocoagulation/flotation Process (전기응집/부상 공정을 이용한 TiO2 폐수의 탁도 제거)

  • Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.19 no.1
    • /
    • pp.89-96
    • /
    • 2010
  • The separation of $TiO_2$ wastewater carried out by an electrocoagulation/flotation process, which had various operating parameters. The effect of electrode material (aluminum and four dimensionally stable electrode), applied current (0.07~0.5 A), electrolyte concentration (0~1 g/L), solution pH (3~11), initial turbidity (1000~20000 NTU) and suspended solid concentration (5000~25000 mg/L) were evaluated. Turbidity removal efficiency of the soluble anode (aluminum), which could produce metal ions, was higher than that of the dimensionally stable electrode. Considering operation time, turbidity removal and electric power, optimum current was 0.19 A. The more NaCl dosage was high, the less electric power was required. However, optimum NaCl concentration was 0.125 g/L considered removal efficiency, operation time and cost. Initial $TiO_2$ concentration did not affected turbidity removal on the electrocoagulation/flotation operation. The electrocoagulation/flotation process was proved to be a very effective separation method in the removal of $TiO_2$ from wastewater.

Study on Separation Characteristics of Flue Gas Using Hydroquinone Clathrate Compounds (하이드로퀴논 크러스레이트를 이용한 배가스 분리 특성 연구)

  • Lee, Jong-Won;Choi, Ki-Jong
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.865-868
    • /
    • 2011
  • An organic substance, hydroquinone is used to form clathrate compounds in order to identify separation characteristics of carbon dioxide in flue gas. Formed samples were analyzed by means of the solid-state $^{13}C$ nuclear magnetic resonance (NMR) and Raman spectroscopic methods to examine enclthration behaviors of guest species. In addition, elemnetal analysis was also performed in order to evaluate separation efficiency of $CO_2$ in a quantitative way. Based on the experimental results obtained, $CO_2$ molecules are found to be captured into the clathrate compound more readily than $N_2$ molecules. Moreover, because such preferential enclathration is even more significant at low pressure conditions, $CO_2$ separation/recovery from flue gas can be achieved with minimizing additional energy cost for the technique. Experimental results obtained in this study can provide useful information on separation techniques of flue gas or selective separation of gas mixtures in the future.

Temperature Effect of the UASB Process for Treatment of Organic Waste (상향류식 혐기성 입상슬러지 공법의 유기폐수 처리 효율에 미치는 온도의 영향)

  • Park, Chul Hwi;Chung, Tai Hak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.4
    • /
    • pp.45-54
    • /
    • 1996
  • Effects of temperature on the efficiency of the Upflow Anaerobic Sludge Blanket(UASB) process for treatment of wastewater from a starch and related products manufacturing industry were investigated using laboratory scale reactors equipped with two types of Gas-Solid Separator(GSS). Both fresh digested sludge and granular sludge stored nearly for one year at room temperature were good as a seeding material. The reactors seeded with aged granular sludge showed slow start-up, however, lowered activity at the initial period was recovered gradually. The GSS with an inner cylinder was proved to be effective in liquid-solid separation compared to the conventional type. Although the rate of organic removal and gas production per unit volatile suspended solids in the reactor reduced significantly as the temperature varied from 35 to $20^{\circ}C$, possibility of operation at low temperatures was shown as a result of gradual buildup of volatile suspended solids in the bed. Stable operation with a reduced efficiency was possible at a COD loading of $5-8kg/m^3/day$ at a temperature as low as $20^{\circ}C$.

  • PDF

Saturation curves for chemical coagulation of wastewater treatment (화학 응집제 투입에 따른 수질항목별 하수처리 반응곡선)

  • Ryu, Jae-Na;Oh, Je-Ill;Lee, Kyeoung-Jong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.537-548
    • /
    • 2010
  • Recently the Government has announced updated water quality standards for wastewater treatment effluent (become effective in 2012). That includes highly enforced regulations for T-P, BOD and COD, and a large budget, in particular for phosphorus removal, was set by the Ministry of environment. Chemical coagulation destabilizes colloidal particles so that particles grow to larger flocs, and solid particles are removed by solid-liquid separation. The efficiency of chemical coagulation depends on a various factors, including coagulant types and costs, construction and operation costs for the treatment facilities and so on. The proper selection should be based on the treatment efficiency of coagulants and underlying costs. The current research was to evaluate the treatment efficiencies of coagulants on a variety of wastewater influents and to develop saturation curves for several water quality parameters. Typical $Al_2(SO_4)_3$ and $FeCl_3$ were tested under a range of coagulant concentrations. The pollutant removal efficiencies of chemical treatment both for the $Al_2(SO_4)_3$ and $FeCl_3$ were especially high for T-P, followed by SS, BOD and COD. Correlation test also proved the highest relationship between SS and T-P.

Rapid Fabrication of Micro-nano Structured Thin Film for Water Droplet Separation using 355nm UV Laser Ablation (355 nm UV 레이저 어블레이션을 이용한 마이크로-나노 구조의 액적 분리용 박막 필터 쾌속 제작)

  • Shin, Bo-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.7
    • /
    • pp.799-804
    • /
    • 2012
  • Recently micro-nano structures has widely been reported to improve the performance of waterproof, heat isolation, sound and light absorption in various fields of electric devices such as mobiles, battery, display and solar panels. A lot of micro-sized holes on the surface of thin film provide excellent sound, or heat, or light transmission efficiency more than solid film and simultaneously nano-sized protrusions around micro hole increase the hydrophobicity of the surface of thin film because of lotus leaf effects as generally known previously. In this paper new rapid fabrication process with 355 nm UV laser ablation was proposed to get micro-nano structures on the surface of thin film, which have only been observed at higher laser fluence. Developed thin micro-nano structured film was also investigated the hydrophobic property by measuring the contact angle and demonstrated the possibility to apply to water droplet separation.

Determination of relevant Characteristics for Cartridge Filters

  • Ogawa, Takao
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1993.04a
    • /
    • pp.1-11
    • /
    • 1993
  • Cartridge filters are widely used in liquid-solid separation processes. To select a proper filter system for the requirements of a given application, a knowledge of filter efficiency and dirt capacity is required. The filter manufacturer needs to provide data which are based on test procedures simulating real parameters on a laboratory scale. There does not exist at present a standard for liquid filter testing (with the exception of the Multipass Test to ISO4752 for hydraulic filters). Users have to work with data based on different test procedures. This paper will discuss principles of filter testing, efficiency andd dirt capacity results as a function of test parameters, and data interpretion to provide a guideline for the end user.

  • PDF

Attrition Characteristics of WGS Catalysts for SEWGS System (SEWGS 시스템을 위한 WGS 촉매들의 마모특성)

  • Ryu, Hojung;Lee, Dongho;Lee, Seungyong;Jin, Gyoungtae
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.2
    • /
    • pp.122-130
    • /
    • 2014
  • Attrition characteristics of WGS catalysts for pre-combustion $ CO_2$ capture were investigated to check attrition loss of those catalysts, to check change of particle size distribution during attrition tests, and to determine solid circulation direction of WGS catalysts in a SEWGS system. The cumulative attrition losses of two catalysts increased with increasing time. However, attrition loss under humidified condition was lower than that under non-humidified condition case for long-term attrition tests. Between two catalysts, attrition loss of PC-29 catalyst was higher than that of commercial catalyst for long-term attrition tests. However, the commercial catalyst generated much more fines than PC-29 catalyst during attrition. Therefore, we conclude that the PC-29 catalyst is more suitable for fluidized bed operation if we take into account the separation efficiency of cyclone. Based on the results from the tests for the effect of humidity on the attrition loss, we selected solid circulation direction from SEWGS reactor to regeneration reactor because the SEWGS reactor contains more water vapor than regeneration reactor.

Effectiveness of Continuous Deflective Separation System to Control Nonpoint Source Pollution from Urban Areas (도시지역 비점오염원 관리를 위한 와류필터형 처리시설의 효율성 연구)

  • Park, Jong-Sik;Koh, Jeung-Hyun;Kim, Sang Keun;Chung, Ha-Ik
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.10 no.6
    • /
    • pp.88-98
    • /
    • 2007
  • The control of nonpoint source pollution from the urban paved areas with high imperviousness in is required to improve the water quality of aquatic resources. This research investigated the characteristics of urban runoffs and evaluate the effectiveness of the continuous deflective separation systems for stormwater best management practice. The systems were installed in the vicinity of a high-level road, an apartment complex, and the Cheonggye stream. Stormwater runoff was sampled in these sites. Biochemical oxygen demand ($BOD_5$), total suspended solid (TSS), total nitrogen (T-N), and total phosphorus (T-P) were analyzed. The removal efficiency of $BOD_5$, TSS, and T-P for the road was 10.9-81.0%, 11.7-93.4%, 0-37.5%, respectively. That of $BOD_5$, TSS, T-N, and T-P for the complex was 12.5-65.8%, 26.5-77.6%, 1.8-28.7%, and 20.0-37.5%, respectively. The abatement efficiency $BOD_5$, TSS, T-N, and T-P for the stream was 7.2-85.2%, 41.7-98.2%, 11.3-65.6%, and 2.0-71.5%, respectively. This study shows that the systems can be used to remove $BOD_5$ and TSS from urban runoffs efficiently.

An Experimental Study on the Treatment of Organic Wastewater by Soil Microbes Using Three-phase Fluidized Bed (삼상유동층 반응기에서 토양미생물에 의한 유기성 폐수처리에 관한 연구)

  • Choung, Youn Kyoo;Chun, Yang Kun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.207-217
    • /
    • 1992
  • In this study, isolated and cultured nitrogen fixed microbes were seeded in the three-phase fluidized bed in which gas, solid and liquid were contacted directly. Input velocity was varied from 8.12 cm/hr to 16.32 cm/hr. And upflow gas pressure was fixed to 80 psi. Return ratios were from 0.2 to 0.6 with the each experimental condition. According to these condition, movement of media, growth of biofilm and removal efficiency were measured. As the results, in case of briquette ash, biofilm was developed to $170{\mu}m$ when velocity was 8.12 cm/hr and return ratio was 0.6. In this condition, COD removal efficiency was 97% and $NH_4$-N removal efficiency was 83%. At the same condition, biofilm thickness of glass bead was $17.59{\mu}m$ and its COD and $NH_4$-N removal efficiency was 83% and 72%. Nitrogen fixed microbes have following characters: it formed dark-brownish sludge, excellent adhesive force, easy solid-liquid separation and low oxygen uptake ratio, but sensitive to DO concentration. Not only it endured shock loading, but required short time to steady state.

  • PDF

Evaluation of Floc Formation Conditions for Increasing Flotation Velocity in DAF Process (DAF 공정에서 부상속도 향상을 위한 플럭형성 조건 평가)

  • Kwon, Soon-Buhm;Min, Jin-Hee;Park, No-Suk;Ahn, Hyo-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.2
    • /
    • pp.245-255
    • /
    • 2006
  • Dissolved air flotation is a solid-liquid separation system that uses fine bubbles rising from bottom to remove particles in water. In order to enhance the flotation velocity and removal efficiency of flocs in the flotation process, we tried to obtain pretreatment conditions for the optimum DAF process operation by comparing and evaluating features of actual floc formation and flotation velocity etc, according to coagulant types and conditions for flocculation mixing intensity by using PIA, PDA, and FSA. Accordingly, generating big flocs that have low density at low flocculation mixing intensity may reduce treatment efficiency. In addition, generating small flocs at high flocculation mixing intensity makes floc-bubbles smaller, which reduces flotation velocity, In this study, it was found that high flocculation mixing intensity could not remove the remaining micro-particles after flocculation, which had negative effects on treated water quality, Therefore, in order to enhance treatment efficiency in a flotation process, flocculation mixing intensity around $50sec^{-1}$ is effective.