• Title/Summary/Keyword: Solid phase cartridge

Search Result 99, Processing Time 0.019 seconds

Determination of Thiamin by Gas-chromatography (기체크로마토그래피법에 의한 티아민 분석)

  • Yoo, Ji-Sang;Moon, Dong-Cheul;Hong, Sung-Hwa;Han, Kun;Kim, Bak-Kwang
    • YAKHAK HOEJI
    • /
    • v.33 no.3
    • /
    • pp.156-160
    • /
    • 1989
  • A gas-chromatographic determination method of thiamin which use a quantitative cleavage of thiamin to 4-methyl-5-(2-hydroxyethyl)thiazol [I] and solvent extraction of the analyte prior to GC injection was modified. A column chromatographic procedure using a reversed phase, high capacity solid phase cartridge was applied to the clean-up of the analyte. Thiazol derivative[I] was quantitatively recovered upon the column method. Acetanilide, an internal standard, has a good recovery through the analytical procedure. The method has analytical precision of 2% or less in the coefficient of variation.

  • PDF

The Analysis of Common Metabolites of Organophosphorus Pesticides in Urine by Gas Chromatography/Mass Spectrometry

  • 박성수;표희수;이강진;박송자;박택규
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.1
    • /
    • pp.45-50
    • /
    • 1998
  • Most organophosphorus pesticides may be metabolized to yield some common phosphates in human or in animals, and these metabolites may be used as the exposure biomarkers to pesticides. In this study, we developed the extraction method of four phosphate metabolites from the spiked human urine in high recovery by the solid phase extraction with a reverse-phase cartridge (cyclohexyl silica) followed by the elution with methanol. The extracted urinary metabolites were derivatized with hexamethyldisilazane/trimethyl-chlorosilane/pyridine (2 : 1 : 10, v/v/v) and identified by gas chromatography/mass spectrometry. Calibration curve obtained from each metabolite standard using by GC/MS/SIM has shown good linearity and detection limits of metabolites were the range of 0.05-0.1 ㎍/㎖ in urine. Phenthoate, one of the organophosphorus pesticides, was orally administrated to rats. Four metabolites were detected in the rat urine. The results of this study may be applied to development of exposure biomarkers for monitoring of environmental pollutants.

Development of Analytical Method and Monitoring of Organophosphorus Pesticides in the Raw Water and Clean Water by Liquid Chromatography-Tandem Mass Spectrometry (LC/MS/MS를 이용한 유기인계 농약류의 최적 분석법 정립과 원·정수에서의 모니터링)

  • Kim, Gyung-A;Song, Mi-Jeong;Yeom, Hoon-Sik;Son, Hee-Jong;Lee, Sang-Won;Choi, Jin-Tack
    • Journal of Environmental Science International
    • /
    • v.24 no.12
    • /
    • pp.1569-1582
    • /
    • 2015
  • The analytical method for 16 organophosphorus pesticides was developed in this study. The 16 organophosphorus pesticides were analyzed by liquid chromatography-tandem mass spectrometry (LC/MS/MS) using on-line solid phase extraction (on-line SPE) with PLRP- S cartridge. Analysis of all analytes in the MS/MS was processed in the electrospray ioni-zation (ESI) positive mode. They are Azinphos ethyl, Chlorfenvinphos, Ethion, Famphur, Phosmet, Phosphamidon, Terbufos, Aspon, Chlorpyrifos-methyl, Crotoxyphos, Dichlofenthi-on, Dicrotophos, Fonofos, Thionazin, Dimethoate and Iprobenfos. Limits of detection (LODs) and Limits of quantification(LOQs) were obtained as 0.8~2.0 ng/L and 2.6~6.4 ng/L, respectively. All compounds were not detected at the 8 sampling points of the raw water and clean water.

Estogenic and Dioxin-like Activity of Influent and Effluent of the Industrial Wastewater Treatment Plant

  • Oh, Seung-Min;Kim, Gi-Sur;Kim, Soung-Ho;Kim, Yun-Hee;Chung, Kyu-Hyuck
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2002.10a
    • /
    • pp.166-166
    • /
    • 2002
  • The response of environmental pollutants can be detected bioanalytically focusing on the source and matrices of concern. Cell culture bioassays are rapid and inexpensive, and thus have great potential for determination of environmental pollution. We have examined the estrogenic and dioxin-like activites of industrial wastewater using E-screen assay and EROD microbioassay. Influent and effluent wastewater were collected from four different industrial wastewater treatment plants, such as cosmetics, paints, textile producing and metal coating plant, and extracted using solid-phase extraction with Oasis@HLB plus cartridge. Pollutants adsorbed to the cartridge were eluted with MTBE. MCF-7 cells were treated with extracts showed various estrogenic potential. The textile wastewater showed strong estrogenic activity and the others showed weak estrogenic activity, No effect was observed in the wastewater from paints producing plant. All extracts showed CYPIA inducing effects, indicating these samples contain dioxin-like chemicals. Bioanalytical results of effluents compared with influents could give us information about the incomplete wastewater treatment and biological potency caused by pollutants. [Supported by a Grant from the Korea Science and Engineering Foundation]

  • PDF

Development of Isotope Dilution-Liquid Chromatography/Tandem Mass Spectrometry as a Candidate Reference Method for the Determination of Acrylamide in Potato Chips

  • Park, Sun-Young;Kim, Byung-Joo;So, Hun-Young;Kim, Yeong-Joon;Kim, Jeong-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.5
    • /
    • pp.737-744
    • /
    • 2007
  • An isotope dilution-liquid chromatography/tandem mass spectrometric method was developed as a candidate reference method for the accurate determination of acrylamide in potato chips, starch-rich foodstuff cooked at high temperature. Sample was spiked with 13C3-acrylamide and then extracted with water. The extract was further cleaned up with an Oasis HLB solid-phase extraction (SPE) cartridge and an Oasis mixed-phase cation exchange (MCX) SPE cartridge. The extract was analyzed by using LC/ESI/Tandem MS in positive ion mode. LC with a medium reversed-phase (C4) column was optimized to obtain adequate chromatographic retention and separation of acrylamide. MS was operated to selectively monitor [M+H]+ ions of the analyte and its isotope analogue at m/z 72 and m/z 75, respectively. Sample was also analyzed by the LC/MS with selectively monitoring the collisionally induced dissociation channels of m/z 72 → m/z 55 and m/z 75 → 58. Compared to the LC/MS chromatograms, the LC/MS/MS chromatograms showed substantially reduced background chemical noises coming from solvent clusters formed during ESI spray processes and interferences from sample matrix. Repeatability and reproducibility studies showed that the LC/MS/MS method is a reliable and reproducible method which can provide a typical method precision of 1.0% while the LC/MS results are influenced by chemical interferences.

Study on Determination of Seven Transition Metal Ions in Water and Food by Microcolumn High-Performance Liquid Chromatography

  • Hu, Qiufen;Yang, Guangyu;Li, Haitao;Tai, Xi;Yin, Jiayuan
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.5
    • /
    • pp.694-698
    • /
    • 2004
  • A new method for the simultaneous determination of seven transition metal ions in water and food by microcolumn high-performance liquid chromatography has been developed. The lead, cadmium, mercury, nickel, cobalt, silver and tin ions were pre-column derivatized with tetra-(4-aminophenyl)-porphyrin ($T_4$-APP) to form the colored chelates which were then enriched by solid phase extraction with $C_{18}$ cartridge. The enrichment factor of 50 was achieved by eluted the retained chelates from the cartridge with tetrahydrofuran (THF). The chelates were separated on a ZORBAX Stable Bound microcolumn ($2.0{\times}50\;mm,\;1.8\;{\mu}m$)with methanol-tetrahydrofuran (95 : 5, v/v, containing 0.05 mol/L pyrrolidine-acetic acid buffer salt, pH = 10.0) as mobile phase at a flow rate of 0.5 mL/min and detected with a photodiode array detector from 350-600 nm. The seven chelates were separated completely within 2.0 min. The detection limits of lead, cadmium, mercury, nickel, cobalt, silver and tin are 4 ng/L, 3 ng/L, 6 ng/L, 5 ng/L, 5 ng/L, 6 ng/L, 4 ng/L respectively in the original samples. This method was applied to the determination of the seven transition metal in water and food samples with good results.

Determination of Niacin in Infant Formula by Solid-phase Clean-up and HPLC with Photodiode Array Detector (고체상 정제 및 HPLC/PDA에 의한 영유아식 중 나이아신의 분석)

  • Hong, Jee-Eun;Kim, Mi-Ran;Cheon, Sang-Hee;Chai, Jung-Young;Park, Eun-Ryong;Mun, Chun-Sun;Gwak, In-Shin;Kim, Ok-Hee;Lee, Kwang-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.3
    • /
    • pp.359-363
    • /
    • 2009
  • This study was performed to establish a rapid and simple analytical method for niacin (nicotinic acid and nicotinamide) using HPLC. A pretreatment method for the extraction and clean-up of niacin in infant formula sample and an instrumental condition for HPLC were optimized. Niacin was extracted by 5 mM hexanesulfonate with ultrasonication for 30 min. For the clean-up of the sample, the extract was applied to a HLB cartridge, and then niacin was eluted from the cartridge using 5 mL of 80% methanol after washing with 5 mL of n-hexane. The total recoveries were $83{\sim}104%$ and relative standard deviation were in the range of $1.5{\sim}3.5%$ during the extraction and clean-up process. Niacin was determined by gradient elution with sodium hexanesulfonate/methanol buffer as a mobile phase and a photodiode array detector (260 nm). It showed a high linearity between the content of niacin and the peak area ($r^2$=1.000) in the range of $0.02{\sim}10.0$ mg/L of nicotinic acid and nicotinamide. The detection limit was 0.02 mg/L (0.2 mg/kg in the sample). The method was successfully applied for the determination of niacin in infant formula. Total niacin contents were in the range of $53.5{\sim}140.3$ mg/kg.

Determination of Pentoxifylline and Metabolite(I) by HPLC (혈장내 Pentoxifylline과 Metabolite(I)의 HPLC에 의한 분석)

  • Min, Byeong-Sun;Choung, Se-Young;Rho, Young-Soo;Youn, Byoung-Ho;Lim, Soo-Han
    • YAKHAK HOEJI
    • /
    • v.32 no.6
    • /
    • pp.415-419
    • /
    • 1988
  • A rapid and simple method for the determination of pentoxifylline and its major metabolite, metabolte(I) in plasma was examined by HPLC. For the purification and enrichment of drug from plasma, solid-phase extraction was examined using Sep-pak C18 cartridge. The effectiveness of test method was proved by monitoring of the rat after oral administration of pentoxifylline in a dose of 40mg/kg.

  • PDF

Rapid and Simple Analytical Method for Removing Patulin from Apple Juice Using Solid Phase Extraction (고체상 추출법(SPE: Solid Phase Extraction)을 이용한 국내 사과주스 중 Patulin 간편.신속 분석방법)

  • Yim, Jong-Gab;Jang, Hae-Won;Lee, Kwang-Geun
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.3
    • /
    • pp.257-262
    • /
    • 2010
  • Patulin, a secondary metabolite of mold, is commonly found in rotten apples. Many countries regulate patulin at levels ranging from 30 to $50\;{\mu}g/L$. Most analytical methods for removing patulin from apple juice include liquid-liquid extraction (LLE), which is time and labor intensive. To replace the LLE method, a solid-phase extraction (SPE) method has been developed for apple juice and unfiltered apple juice. A portion of the test sample was applied to a macroporous copolymer cartridge and washed with 5 mL of 1% sodium bicarbonate, followed by 5 mL of 1% acetic acid. Patulin was eluted with 5 mL of 2% acetonitrile in anhydrous ethyl ether. The mobile phase was tetrahydrofuran in water (0.8:99.2) and was detected with a UV detector at 276 nm. Recoveries ranged from 95 to 101% in test samples, and the minimum detectable level was 30 ppb. Because this SPE method is fast, easy, reliable, and inexpensive, it could be applicable for companies or analytical agencies to analyze patulin concentrations in apple juice.

Analysis of tetracyclines in shrimp samples based on a two-step extraction approach prior to high-performance liquid chromatography

  • Thinnakorn Sukkhunthod;Thanakorn Pluangklang;Sumita Boonnab;Sira Sansuk;Phitchan Sricharoen;Maliwan Subsadsana
    • Analytical Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.211-219
    • /
    • 2024
  • This study presents a sensitive and reliable method for determining tetracycline (TC), oxytetracycline (OTC), and chlortetracycline (CTC) residues in shrimp samples. A two-step process involving liquid-liquid extraction (LLE) followed by solid-phase extraction (SPE) was developed prior to HPLC analysis. The target analytes were effectively extracted using EDTA/McIlvaine buffer (pH 4.0): methanol (80:20, %v/v), with subsequent clean-up using a C18 SPE cartridge. HPLC separation was conducted on a C18 column (250 mm × 4.6 mm i.d., 5 ㎛) at 30 ℃, using 0.01 % trifluoroacetic acid (A) and acetonitrile (B) as the mobile phase. A gradient elution protocol was applied, transitioning from 85(A):15(B) %v/v to 70(A):30(B) %v/v at 7 min, with a 5 min hold, followed by adjustment to 85(A):15(B) %v/v for 13-14 min. The detection was performed using photodiode array (PDA) at 365 nm with a flow rate of 1.0 mL/min. The calibration curves exhibited good linearity within a concentration range of 0.4-6.0 ㎍/mL (R2 > 0.995). The limits of detection (LOD) for TC, OTC, and CTC in shrimp were 0.034, 0.029, and 0.021 ㎍/mL, respectively. The limits of quantitation (LOQ) for TC, OTC, and CTC were found to be 0.114, 0.097, and 0.071 ㎍/mL, respectively. Recoveries of TC, OTC, and CTC from spiked shrimp samples ranged from 91.0 % to 95.5 %, 92.4 % to 97.2 %, and 93.3 % to 96.6 %, respectively. This method was successfully applied to the determination of TC, OTC, and CTC residues in shrimp samples sourced from various local markets.