• Title/Summary/Keyword: Solid phase ELISA

Search Result 15, Processing Time 0.026 seconds

Qualitative Enzyme-Linked Immunosorbent Assay (ELISA) for the Diagnosis of Edwardsiellosis (Edwardsiellosis의 진단을 위한 정성적 ELISA법)

  • Kim, Myoung-Sug;Hwang, Eun-A;Huh, Min-Do;Jeong, Hyun-Do
    • Journal of fish pathology
    • /
    • v.12 no.1
    • /
    • pp.24-31
    • /
    • 1999
  • Optimization and standardization of solid phase enzyme immunoassay were done for the diagnosis of edwardsiellosis in fish. The analyzed degree of immobilized antibody on surface of solid phase with peroxidase saturation method showed the optimized result by using partially purified $50{\mu}g/ml$ of rabbit anti-E. tarda Edk-2 antibody in sodium bicarbonate buffer for overnight incubation to cover the surface of polystyrene beads. Optimized immunoreaction was observed in the treatment of $50{\mu}g/ml$ of biotin conjugated antibody followed extravidin-peroxidase diluted 1 : 2,000 in PBS. The detectable concentrations of the this method were $1{\times}10^5$ cells/ml and $1{\times}10^5$ cells/ml expressed as the source of antigen amount for EDTA extraction and heat extraction, respectively. High cross-reaction of solid phase ELISA with the prepared rabbit and-E. tarda Edk-2 was observed against E. tarda strains isolated from flounder suffering from edwardsiellosis in aquatic farms of Korea. It suggested that the potential of this solid phase of ELISA technique is very powerful for the application to different strains of E. tarda isolated in farms of many different areas.

  • PDF

Studies on the development of enzyme linked immuno-sorbent assay (ELISA) for hepatitis B surface antigen (HBsAg) by monoclonal antibodies of different affinity constants

  • Kim, Gye-Won;Hong, Sung-Youl;Shin, Soon-Cheon;Lee, Sung-Hee;Kim, Won-Bae
    • Archives of Pharmacal Research
    • /
    • v.10 no.1
    • /
    • pp.18-24
    • /
    • 1987
  • Mouse monocolonal antibodies to Hepatitis B surface antien (HBsAg) were prepared and their functional capabilities tested by the method of solid phase enzyme linked immuno sorbent assay (ELISA). HBsAg binding studies inicated that one monoclonal antibody 6E-1-1 bound more HBsAg at a faster rate than the other monoclonal antibodies. Also, for the binding inhibition studies with the selected monoclonal antibody 6E-1-1, one monoclonal antibody 8D-3-6 didn't exhibit binding inhibition for HBsAg. Then, a simultaneous ELISA method was developed for the immunodiagnosis of HBsAg. Different combinations of two monoclonal antibodies as solid phase and horseradish peroxidase (HRPO) labeled phase were studied. The combination of monoclonal antibody of higher affinity constant (6E-1-1) immobilized in a solid phase and monoclonal antibody of lower affinity constant (8D-3-6) as a HRPO laeled phase was more sensitive when two monoclonal antibodies of different affinity constants for HBsAg were prepared.

  • PDF

Establishment and application of a solid-phase blocking ELISA method for detection of antibodies against classical swine fever virus

  • Cao, Yuying;Yuan, Li;Yang, Shunli;Shang, Youjun;Yang, Bin;Jing, Zhizhong;Guo, Huichen;Yin, Shuanghui
    • Journal of Veterinary Science
    • /
    • v.23 no.5
    • /
    • pp.32.1-32.11
    • /
    • 2022
  • Background: Classical swine fever (CSF) is a severe infectious disease of pigs that causes significant economic losses to the swine industry. Objectives: This study developed a solid-phase blocking enzyme-linked immunosorbent assay (spbELISA) method for the specific detection of antibodies against the CSF virus (CSFV) in porcine serum samples. Methods: A spbELISA method was developed based on the recombinant E2 expressed in Escherichia coli. The specificity of this established spbELISA method was evaluated using reference serum samples positive for antibodies against other common infectious diseases. The stability and sensitivity were evaluated using an accelerated thermostability test. Results: The spbELISA successfully detected the antibody levels in swine vaccinated with the C-strain of CSFV. In addition, the detection ability of spbELISA for CSFV antibodies was compared with that of other commercial ELISA kits and validated using an indirect immunofluorescence assay. The results suggested that the spbELISA provides an alternative, stable, and rapid serological detection method suitable for the large-scale screening of CSFV serum antibodies. Conclusions: The spbELISA has practical applications in assessing the vaccination status of large pig herds.

Study on the production and management of aquatic animals : direct detection of Edwardsiella tarda using an enzyme linked immunosorbent assay (수생산물의 생산과 관리에 관한 기초연구 : ELISA법을 이용한 Edwardssiella tarda의 직접 검출)

  • Chung, Soon-Yoon;Sohn, Sang-Gyu;Chung, Joon-Ki;Huh, Min-Do;Jeong, Hyun-Do
    • Journal of fish pathology
    • /
    • v.10 no.2
    • /
    • pp.75-86
    • /
    • 1997
  • Solid phase enzyme linked immunosorbent assay (ELISA) was developed to detect the whole cells of Edwardsiella tarda from infected tissues of flounder. Cross-reaction test was performed by ELISA against fish pathogens such as A. hydrophila ATCC7966. V. anguillarum HYUFP5001, Y, ruckeri 11-4, E. ictaluri and Streptococcus sp. NG8206. Rabbit anti-E, tarda Edk-2 sera highly cross-reacted with A. hydrophila ATCC7966 and V. anguillarum HUFP5001. However, the cross-reaction was removed by using the anti-serum pre-adsorbed with A, hydrophila ATCC7966 FKC. The intra-species cross-reaction among E. tarda isolates was very high. ELISA with the whole cell antigens present in tissue homogenate appeared with highly decreased sensitivity, presumably by the co-coating of lipid or proteins in tissues. Thus, it would be necessary to use the infected tissue homogenates diluted more than 100 times with PBS for diagnosis. Interestingly, compared with the using of FKC antigen, the direct detection of viable cells in tissue homogenate showed more sensitive results with detection limit of $1{\times}10^3$ cells/ml in buffer or diluted tissue homogenate. Consequently, the ELISA method developed in this study was specific, rapid and sensitive for diagnosing edwardsiellosis.

  • PDF

Methods for Coating the Killed Whole Cell Antigens of Salmonella typhi in Enzyme-linked Immunosorbent Assay (효소면역측정법을 위한 장티푸스 균체항원의 부착방법)

  • Kim, Youn-Won;Hwang, Eung-Soo;Kook, Yoon-Hoh;Choi, Kang-Won;Kim, Ik-Sang;Cha, Chang-Yong;Lee, Seung-Hoon
    • The Journal of the Korean Society for Microbiology
    • /
    • v.20 no.1
    • /
    • pp.91-102
    • /
    • 1985
  • The advantages of enzyme-linked immunosorbent assay(ELISA) are its senstivity and simplicity in detecting IgG, IgM and IgA antibody. To apply ELISA to diagnosis of typhoid fever, antigen such as lipopolysaccharide of Salmonella typhi or killed whole cell must be coated on solid phase. It is easy to coat lipopolysaccharide on ELISA plate but troublesome to purify it. As it is easy to obtain the killed whole cells, the development of the appropriate method by which those antigens of S. typhi are optimally coated on solid phase is needed. To establish the appropriate method, carbonate buffer, methanol or poly-L-lysine was applied as binding substance on polystyrene or polyvinylchloride plate as solid phase when the killed whole cell antigens of S. typhi varided as follows: $10^6$, $10^7$, $10^8$ and $10^9\;cell/ml$. The criteria of the optimal method were determined as follows: 1. The optical density of positive sera is above 1.0(0.6 in IgM) at 1:10 serum dilution and is 0.3(0.2 in IgM) higher than that of negative sera: 2. The O.D. of sera is flat or lowering according to serum dilution: 3. It must be that the O.D. of negative sera is lower than 0.2 at the point of serum dilution where the O.D. of positive sera is higher than 1.0(0.5 in IgM). The results obtained were summarized as follows: 1. The methods which fitted the above criteria were to use poly-L-lysine as binding substance, polyvinylchloride plate as solid phase and $10^7\;cell/ml$ as antigen concentration of S. typhi(poly-L-lysine/polyvinylchloride/$10^7$) and poly-L-lysine/polyvinylchloride/$10^8$ in detecting IgG antibody, methanol/polystyrene/$10^9$, poly-L-lysine/polyvinylchloride/$10^8$ and poly-L-lysine/polyvinylchloride/$10^9$ in IgM and carbonate buffer/polystyrene/$10^8$, carbonate buffer/polystyrene/$10^9$, methanol/polystyrene/$10^8$, methanol/polyvinylchloride/$10^8$, methanol/polyvinylchloride/$10^9$, poly-L-lysine/polyvinylchloride/$10^8$ and poly-L-lysine/polyvinylchloride/$10^9$ in IgA. 2. The coaling method using poly-L-lysine, polyvinylchloride plate and $10^8\;cell/ml$ was best to assay IgG, IgM and IgA antibody all in one. By this method, to assay the each immunoglobulin calss with an appropriate fixed serum dilution, 1:320 dilution was best.

  • PDF

Characteristics and application of monoclonal antibody to progesterone II. Development of progesterone enzyme-linked immunosorbent assay(ELISA) (Progesterone의 단크론성 항체에 관한 특성 및 활용에 관한 연구 II. ELISA 기법의 개발)

  • Kang, Chung-boo;Kim, Jong-shu
    • Korean Journal of Veterinary Research
    • /
    • v.31 no.4
    • /
    • pp.403-409
    • /
    • 1991
  • This experiment was carried out to develop a sensitive, rapid, solid-phase microtitre plate assay of progesterone using the monoclonal antibody to this hormone. Monoclonal antibody to progesterone was much higher titre and binding affinity about 10 times than conventional polyclonal antibody to progesterone. Dot-blot analysis of monoclonal antibody revealed a single precipitation band when reacted with anti-mouse IgM and anti-mouse K. A competitive reaction was used with a reaction time of 2 hours. The standard dose-response curve was linear through 1,000pg/well. This ELISA system approach is applicable to evaluation for the rapid assessment of luteal function and reproductive status in both clinical and research in a wide variety of species.

  • PDF

Development of Heterologous ELISA System for Diagnosis of Pregnancy in Swine (돼지 임신 진단을 위한 Heterologous ELISA 법 개발)

  • Park, Sung-Min;Lee, An-Na;Yoon, Taek-Joon;Park, Yong-Su;Song, Tae-Jun;Kim, Young-Hoon;An, Hyo-Sun;Park, Won-Choul;Kim, Jong-Bae
    • Reproductive and Developmental Biology
    • /
    • v.34 no.3
    • /
    • pp.161-167
    • /
    • 2010
  • Early diagnoses of pregnancy for animal such as swine and bovine is extremely important to increase income of a farmhouse and for the management of farm. For the development of immunoasaay system of pregnancy in swine, we report a competitive heterologous enzyme linked immunosorbent assay (ELISA) for the direct measurement of oestrone sulfate (E1S) in diluted urine using anti-E1G (glucuronide) monoclonal antibody which cross react with ElS. The principle of assay was based on the typical solid-phase competitive ELISA methods using E1G-HRP (horseradish peroxidase) as a tracer and E1S for standard. The method had a reasonable sensitivity for the detection of E1S with 0.15 ng/ml as a detection limit. The intra-assay and inter-assay precisions were raging coefficient of from 8.50~9.67% and 8.50~9.87%, respectively, which were quite acceptable. In a field trial with a group 37 sows (18 non-pregnancy and 19 pregnancy sows) after day 29~30 post service, the concentration of E1S were determined to be below 30 ng/ml in all non-pregnancy group and over 48 ng/ml in pregnancy group except one sample. The method described here, heterologous ELISA for the measurement of E1S in urine is good enough for monitoring the early pregnancy test of swine.

A Study on the Measurement of Anti-Cyclic Citrullinated Peptide (Anti-CCP) (Anti-Cyclic Citrullinated Peptide(Anti-CCP) 측정에 대한 연구)

  • Seo, Seol
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.1
    • /
    • pp.42-48
    • /
    • 2007
  • This study was carried out to review and evaluate anti-CCP ELISA assay for diagnostic in RA patients from an early arthritis clinic (EAC). The subjects were obtained from patients visiting the outpatient clinic of the Dept. of Rhumatology med.of P hospital in Daegu, during 6 months from July 1, 2006 to December 31, 2006. The subjects were 140 cases : 80 cases from RA patients (60 women and 20 men; mean age 58 years; range, 32-68 years) confirmed by clinical diagnostic. 39 cases of these RA patients were classified as having early RA (EAC). 50 cases (non-RA) did not fulfill the criteria for RA, and 10 cases were from healthy individuals. We performed the analysis with solid phase-ELISA method (ETI-max3000, Diasorin; Italy) for anti-CCP and Nephelometry assay (Roche/Hitachi 902 analyzer; USA) for RF. The results obtained were summarized as follows ; anti-CCP ELISA is more specific than RF Nephelometry assay (specificity 94% vs 90%) to diagnose RA patients with suspected EAC (early arthritis clinic). The combination test "anti-CCP and RF" had a very high specificity (specificity 98.3%, PPV; RA group 96%, EAC 95%), the difference was statistically significant (p<0.05). Anti-CCP ELISA had more sensitivity in EAC (Early arthritis clinic) patients than chronic RA patients (sensitivity 64% vs 24%, respectively), anti-CCP of RA group and EAC group was more specific than RF (anti-CCP PPV; 92%, 89% vs 89%, 81% respectively), the difference was statistically significant (p<0.05). The difference of antibody concetration between anti-CCP and RF for RA and the control group is statistically significant (p<0.05). In conclusion, anti-CCP ELISA testing may be useful if performed concomitantly with RF Nephelometry assay to diagnose RA patients with suspected EAC (early arthritis clinic).

  • PDF

Development of Chemiluminescence Immunoassay(CIA) & ELISA for the Detection of Anti-sperm Antibodies in Male Serum (항정자 항체 검출을 위한 CIA 및 ELISA 개발을 위한 기초 연구)

  • Kim, S.C.;Lee, K.S.;Kim, Y.K.;Kim, C.K.;Choi, K.H.;Kwon, O.J.;Kim, J.B.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.17 no.1
    • /
    • pp.71-80
    • /
    • 1990
  • New immunoassay systems for the detection of anti-sperm antibodies were developed. For this, sperm surface protein was purified by the immunoaffinity column prepared by the coupling of rabbit anti-human IgG antibodies to Sepharose-4B. Fraction eluted by tris-HCI buffer containing SDS showed a single band having molecular weight of about 60KD on electrophoresis. Enzyme HRP labelled goat anti-human IgG and chemiluminescence aminobutylethyl-isoluminol(ABEI) labelled rabbit anti-human IgG were used for ELISA and CIA, respectively. These two labelled conjugate bound well with human IgG. When serum dilution curves were made to titrate positive serums, two kinds of curves with steep and sluggish slopes were obtained Serum samples were categorized into 3 groups: positive, weak positive and negative based on slope of curve and O.D. values at 1:160 dilution of serum. When ELISA and CIA were compared to conventional method Kibrick test by the determinations of 62 male serums with different diagnosis, the results of ELISA and CIA agreed well, but both disagreed with that of Kibrick test. This study showed that purified sperm surface antigen can be used to develope solid-phase immunoassay systems such as ELISA and CIA which may eliminate the problems encounted the immobilization of living sperm in other tests.

  • PDF