• 제목/요약/키워드: Solenoid Control

검색결과 374건 처리시간 0.024초

고정밀도 솔레노이드 방식의 원자로 제어봉 위치지시기 (High Precision Solenoid Type Nuclear Reactor Control Rod Position Indicator)

  • 백민호;홍훈빈;박희준
    • 전기학회논문지
    • /
    • 제65권11호
    • /
    • pp.1848-1853
    • /
    • 2016
  • Control Rod Position Indicator in nuclear reactor vessel has developed for small reactor in Korea. Because of severe environment in reactor vessel, target of this study is to develop the suitable position indicator. In this study, solenoid type position indicator made of Mineral Insulated Cable(MI Cable) was introduced to adapt in severe environment. And inductance of the solenoid was used to indicate the rod position for high precision. But problem of this concept is that a linear slope of inductance is changed by temperature effect. To resolve this problem, two sensing coils were introduced for temperature compensation. A role of the sensing coil is to make reference linear equation about certain temperature. To confirm this concept, also, inductance of solenoid and sensing coils were measured at room and high temperature (${\sim}300^{\circ}C$). The results of measurement show that the position error of sensing coil between room and high temperature was about 2%. But it was identified that this error was resulted from insufficient test environment (temperature error between solenoid and sensing coils was about 2% at high temperature condition). Therefore, solenoid type position indicator shows that it is very suitable in reactor vessel as a high precision rod position indicator.

고속전자밸브를 이용한 유압실린더의 PWM 제어에 관한 연구 (A Study on PWM Control of Hydraulic Cylinder Using High Speed Solenoid Valve)

  • Park, S.H.;Lee, J.K.
    • 한국정밀공학회지
    • /
    • 제12권7호
    • /
    • pp.138-147
    • /
    • 1995
  • The conventional PWM method, which was used in controlling the on-off valve, such as high-speed solenoid valve, was modulating the width of the pulse applied to the valve, by selecting arbitrary sampling time and modulating the duty-ratio in proportion to the error. However, in this method, a selection of long sampling time was inevitable and it was unable to get a high accuracy and a quick response. This study is for designing an appropriate controller for high-speed solenoid valve by proposing an improved duty-ratio modulation method using the Saw-toothed Carrier Wave which enables a short sampling time selection, high accuracy of control, and a quick response. Test which was carried out in the laboratory shows that transient and steady state response could be improved by PID controller.

  • PDF

솔레이노-유량제어 방식 ABS의 응답성 향상에 관한 연구 (A Study on the Impronement on the Response of Solenoid-Flow control type ABS Modulator)

  • 송창섭;김형태
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.569-572
    • /
    • 1995
  • In this study, a hydraulic modulator of solenoid-flow type ABS, the master sylinder, and the wheel cylinder are modeled and simulated for increasing pressure characteristics of the brake. Response can be predicted by external force of the the master sylinder and pulses to the solenoid valve as input. For a demonstration of simulation result, experiment is done under the same condition as simulation condition after experimental apparatus of 1/4 car model is constructed. When factors of flow control valve are changed, the effect of each factor to response, how to improve response, and the most critical factors are considered from simulated result of time constant.

  • PDF

IMV 비례 유량제어밸브 정특성 선형해석 (Liner Analysis of IMV Proportional Flow Control Valve Static Characteristics)

  • 정규홍
    • 드라이브 ㆍ 컨트롤
    • /
    • 제16권4호
    • /
    • pp.56-64
    • /
    • 2019
  • Recently, as the environmental regulation for earth moving equipment has been tightened, advanced systems using electronic control have been introduced for energy savings. An IMV(Independent Metering Valve), which consists of four 2-way valves, is one of the electro-hydraulic control systems that provides more flexible controllability and potential for energy savings in excavators, when compared to the conventional 4-way spool valve system. To fully realize an IMV, a two-stage bi-directional flow control valve which can regulate the large amount of flow in both directions, should be developed in advance. A simple design that allows proportional flow control to apply the pilot pressure from the current-controlled solenoid to the spring loaded flow control spool and thus valve displacement, is proportional to the solenoid current. However, this open-loop type valve is vulnerable to flow force which directly affects the valve displacement. Force feedback servo of which the position loop is closed by the feedback spring which interconnects the solenoid valve and flow control spool, could compensate for the flow force. In this study, linearity for the solenoid current input and robustness against load pressure disturbance is investigated by linear analysis of the static nonlinear equations for the IMV proportional flow control valve with feedback spring. Gains of the linear system confirm the performance improvement with the feedback spring design.

전자밸브를 이용한 ABS 슬립율 제어에 관한 연구 (A Study of ADS Slip Ratio Control using Solenoid Valve)

  • 최종환;김승수;양순용;박성태;이진걸
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.676-681
    • /
    • 2001
  • ABS is a safety device, which adds hydraulic system to the existing brake system to prevent wheel from locking, so we can obtain maximum braking force on driving. The hydraulic system to control braking pressure consists of sol-flow type using solenoid valve, flow control valve or consists of sol-sol type using two solenoid valve. In this paper, the hydraulic system in ABS is composed of sol type using a 3port-2position solenoid valve, and vehicle system is composed of 1/4 vehicle model. And slip ratio is controlled using PWM (Pulse-Width-Modulation) control algorithm. Braking friction coefficient and tracking friction coefficient which are described by slip ratio's function have maximum value when slip ratio has its value from 0.1 to 0.3. And slip ratio is controlled constantly in this boundary value even in the variation of road's condition in some boundary.

  • PDF

시스템 식별을 이용한 비례솔레노이드밸브 위치제어기 설계 (Design of Position Controller for Proportional Solenoid Valve Using System Identification)

  • 정규홍
    • 유공압시스템학회논문집
    • /
    • 제7권4호
    • /
    • pp.23-31
    • /
    • 2010
  • As the analysis and design technologies for electro-magnetic actuation has advanced over the years, proportional solenoid valve is gaining acceptance in wide range of industrial and commercial applications because of its superior characteristics over the conventional AOV or MOV, such as improved performance, reduced maintenance costs. This research deals with the position controller design of two-stage flow control solenoid valve. Investigation of steady-state characteristics and dynamic model identification for pilot disc is performed. Least square method to minimize the error magnitude of frequency response between the closed-loop and target system is applied to the design of PI-controller gains. From the experiments of step and frequency response, it is concluded that the controller meets the performance specification of target system, which verifies the usefulness of controller design method for proportional solenoid valve.

  • PDF

유압 전자 파일럿밸브를 이용한 섬유송출기 속도제어에 관한 연구 (A Study on Speed Control of Textiles Let off Using Hydraulic Solenoid Pilot Valve)

  • 이재구;김도태;김성동
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 추계학술대회 논문집
    • /
    • pp.225-230
    • /
    • 2002
  • Machine of textiles let off is equipment supplying constantly fabrics. Nowdays, as it is replaced band - brake type with hydraulic motor driven type, we looked into characteristic of hydraulic solenoid pilot direction valve(SPDV) for controlling acceleration performance of hydraulic motor. This study deals with controlling the initial speed of textiles let off machine. Finally, to control the initial speed of hydraulic motor, we controlled the adjustment screw of SPDV by a hand. Test which was carried out in the laboratory shows that initial speed of textiles let off could be improved by controlling adjustment screw of SPDV. Also, the results of experiment work were compared with dynamic characteristic of other on/off solenoid direction valve(SDV).

  • PDF

Study on Mathematical Modeling and Response Characteristics of High-speed Solenoid Valve for Aero-engine

  • Zhang, Xiaodong;Yang, Yutao
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.80-83
    • /
    • 2008
  • Because of its advantages of simple structure, fast response speed, strong anti-pollution ability and good stability, high-speed solenoid valve has been widely used in aeroengine control systems, and some performances of the aeroengine control systems were affected directly by the response speed of high-speed solenoid valve. For some two-position two-way highspeed solenoid cone-valve, the paper discusses the establishment of its mathematical model and analyses its response characteristics by simulation model which is run in simulink of Matlab. Further more, a backstepping and segmentation method is used in the research of response characteristics, and the method is proved to be an accurate, fast and new method to get the influences of parameters on the valve s response characteristics.

  • PDF

본드선도를 이용한 비례전자 감압밸브의 수치해석 (Numerical Analysis of Proportional Pressure Control Valve using Bondgraph)

  • 양경욱;허정규
    • 동력기계공학회지
    • /
    • 제12권2호
    • /
    • pp.62-70
    • /
    • 2008
  • The paper made a description of the method for numerical analysis and modeling of a proportional pressure control valve by bondgraph. The valve is a three port pressure regulator valve, consists of two subsystems; a proportional solenoid and a spool assembly. A purpose of this study is to analysis the dynamic characteristics of the valve using bondgraph method and to verified results that each of parameters has an effect on modeling. It considered the effect which the presence of solenoid, flow coefficient and non-linearity of resistance causes in the valve modeling. In particular, it is analyzed the effect that the solenoid interacted with modeling results and characteristics of the nonlinear resistance through orifice on the supply and discharge side of valve. Thus this paper described method to present nonlinear characteristics by bondgraph modeling method, so that we could know easily result that each parameters has an effect on the modeling.

  • PDF

차동PWM방식에 의한 유압실린더의 위치제어 (Position Control of a Hydraulic Cylinder by a Differential PWM Method)

  • 권기수;이창돈;이진걸
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제15권4호
    • /
    • pp.54-69
    • /
    • 1991
  • This study deals with the position control of a hydraulic cylinder system operated by two port 3-way high speed solenoid valve in Pulse-Width-Modulation mode, instead of using conventional electro-hydraulic servovalve. Due to the complexity and the relatively poor reliability of the servovalve, an actuator using simpler and more study high speed solenoid valve will be presented. The high speed solenoid valve acts as converters of electronic pulse signal to hydraulic ones. It has been pointed out that there are practical problems to be solved in the PWM system, that is (1) accuracy of positioning control becomes considerably insufficient because the system is affected by on/off action of the solenoid valves, and (2) serious nonlinerality appears in the valve characteristics as a result of the switching behavior of the valves. As a method to overcome these defects, the differential PWM driving method of a hydraulic cylinder that improved the steady-state-error, flow rate nonlinearity in simple PWM, and the hydraulic hunting of dead time compensated-PWM driving is proposed in this study.

  • PDF