• Title/Summary/Keyword: Solar radiation calculation

Search Result 91, Processing Time 0.021 seconds

An Effective Algorithm for Transmitted Solar Radiation Calculation through Window Glazing on a Clear Day

  • Oh, John Kie-Whan
    • KIEAE Journal
    • /
    • v.14 no.4
    • /
    • pp.35-45
    • /
    • 2014
  • The main objective of this study is to provide an effective algorithm of the transmitted solar radiation calculation through window glazing on a clear day. This algorithm would be used in developing a computer program for fenestration system analysis and shading device design. Various simulation methods have been evaluated to figure out the most accurate and effective procedure in estimation of transmitted solar radiation on a tilted surface on a clear day. Characteristics of simulated results of each step have been scrutinized by comparing them with measured results of the site as well as results from other simulation programs. Generally, the Duffie & Beckman's solar calculation method introducing the HDKR anisotropic model provided the most reliable simulation results. The DOE-2 program usually provided over-estimated simulation results. The estimation of extraterrestrial solar radiation and beam normal radiation were conducted pretty accurately. However, the solar radiation either on horizontal surface or on tilted surface involves complicated factors in estimation. Even though the estimation results were close to the real measured data during summer when solar intensity is getting higher, the estimation provided more error when solar intensities were getting weaker. The convex polygon clipping algorithm with homogeneous coordinates was fastest model in calculation of sunlight to shaded area ratio. It could not be applied because of its shape limitation.

Correction of One-layer Solar Radiation Model by Multi-layer Line-by-line Solar Radiation Model (다층 상세 태양복사 모델에 의한 단층 태양복사 모델의 보정)

  • Jee, Joon-Bum;Lee, Won-Hak;Zo, Il-Sung;Lee, Kyu-Tae
    • Atmosphere
    • /
    • v.21 no.2
    • /
    • pp.151-162
    • /
    • 2011
  • One-layer solar radiation(GWNU; Gangneung-Wonju National University) model is developed in order to resolve the lack of vertical observations and fast calculation with high resolution. GWNU model is based on IQBAL(Iqbal, 1983) and NREL(National Renewable Energy Laboratory) methods and corrected by precise multi-layer LBL(Line-by-line) model. Input data were used 42 atmospheric profiles from Garand et al.(2001) for calculation of global radiation by the Multi-layer and one-layer solar radiation models. GWNU model has error of about -0.10% compared with LBL model while IQBAL and NREL models have errors of about -3.92 and -2.57%, respectively. Global solar radiation was calculated by corrected GWNU solar model with satellites(MODIS, OMI and MTSAT-1R), RDPS model prediction data in Korea peninsula in 2009, and the results were compared to surface solar radiation observed by 22 KMA solar sites. All models have correlation($R^2$) of 0.91 with the observed hourly solar radiation, and root mean square errors of IQBAL, NREL and GWNU models are 69.16, 69.74 and $67.53W/m^2$, respectively.

CFD Simulations of the Ground Surface Temperature and Air Temperature, Air flow Coupled with Solar Radiation (태양복사열에 따른 지표면 온도와 열, 기류 환경 시뮬레이션 연구)

  • Lee, JuHee;Kim, JaeGwon;Yoon, JaeOck
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.65-70
    • /
    • 2014
  • The thermal environment in a small city rapidly deteriorates due to the urbanization and overpopulation. It is important to understand and predict the thermal environment in a city area. The thermal environment is highly affected by the solar radiation and temperature distributions changing over time periodically. To predict the thermal environment precisely, the solar radiation calculation including radiation strength, incidence angle, and thermal radiation between building surface and ground should be considered. In this study, the computational domain includes various artificial structures such as building, ground, asphalt, brick and grass. To consider the solar radiation, the unsteady state numerical calculation is performed from sun rise to mid-day (2:00pm). The numerical methods consist of solar load and one dimensional heat conduction through the boundaries to reduce the computational load and improve the flexibility of the calculation.

The Calculation on the Optimum Angle of Tilt Type Window by Length of Transmitted Solar Radiation (투과일사의 유입길이에 따른 Tilt 창호의 적정 기울기 산정)

  • Cho, Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.9
    • /
    • pp.635-640
    • /
    • 2010
  • This study is suggested tilt window type to be restrained solar radiation through vertical window type in buildings. The shading and aesthetical effect of buildings would be solved by installation of tilt window type. For investigate optimum an angle of tilt window and building azimuth in reference region, the distance of transmitted solar radiation is calculated. The results of calculation showed optimum an angle of tilt window is obtained $7^{\circ}$ that the distance of transmitted solar radiation is 20% of 1.5m of balcony width. In case of an tilt window angle of $7^{\circ}$, the optimum building azimuth is showed $SW15^{\circ}{\sim}SE15$.

Circulation Effect of the Transparent Insulated Opaque Envelopes (투명 단열외피를 통한 환기효과에 관한 연구)

  • Kim, S.H.;Kim, S.J.;Lee, S.
    • Solar Energy
    • /
    • v.20 no.4
    • /
    • pp.31-43
    • /
    • 2000
  • A model house with a "Ondol" heating working with solar energy and supplied by circulation air was investigated both experimentally and theoretically, A calculation method was developed for interpreting the measured values and for comparing several variants, This calculation method together with the measurement result is presented in the following. The gain in energy of the collector(Trombe wall type with TWD) measured on a particularly selected winter day with plenty of radiation amounted to approximately 31 % of the total solar radiation.

  • PDF

The Solar Atmospheric Transmittance Data for Peak Cooling Load Calculation using ETD Method (실효온도차법에 의한 최대열부하계산용 일사 대기투과율)

  • Kim, D.C.;Seo, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.4
    • /
    • pp.316-322
    • /
    • 1992
  • A simplified TAC method was developed for the selection of solar atmospheric transmittance data fundamental to the calculation of design solar radiation for the peak cooling load calculation using ETD method. The summer and autumn solar atmospheric transmittance data of the 11 major cities in Korea were obtained. Based on the simplified TAC method, the atmospheric transmittance data were selected by the TAC 2.5% of July instead of the TAC 2.5% of June through September for summer and the TAC 5.0% of October instead of the TAC 2.5% of October and November for autumn. Results show that the atmospheric transmittance data at solar noon were in the range of 0.61-0.66 for summer and 0.78-0.82 for autumn except for Pusan and Incheon.

  • PDF

New mathematical approach to determine solar radiation for the southwestern coastline of Pakistan

  • Atteeq Razzak;Zaheer Uddin;M. Jawed Iqbal
    • Advances in Energy Research
    • /
    • v.8 no.2
    • /
    • pp.111-123
    • /
    • 2022
  • Solar Energy is the energy of solar radiation carried by them in the form of heat and light. It can be converted into electricity. Solar potential depends on the site's atmosphere; the solar energy distribution depends on many factors, e.g., turbidity, cloud types, pollution levels, solar altitude, etc. We estimated solar radiation with the help of the Ashrae clear-sky model for three locations in Pakistan, namely Pasni, Gwadar, and Jiwani. As these locations are close to each other as compared to the distance between the sun and earth, therefore a slight change of latitude and longitude does not make any difference in the calculation of direct beam solar radiation (BSR), diffuse solar radiation (DSR), and global solar radiation (GSR). A modified formula for declination angle is also developed and presented. We also created two different models for Ashrae constants. The values of these constants are compared with the standard Ashrae Model. A good agreement is observed when we used these constants to calculate BSR, DSR, GSR, the Root mean square error (RMSE), Mean Absolute error (MABE), Mean Absolute percent error (MAPE), and chisquare (χ2) values are in acceptance range, indicating the validity of the models.

Calculation of Solar radiation based on Cloud Data for Major cities of Korea (국내 주요도시의 운량데이터를 이용한 일사산출)

  • Yoo, Ho-Chun;Lee, Kwan-Ho;Park, So-Hee
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.142-147
    • /
    • 2008
  • Limited fossil fuels and unstable energy supply are considered as one of the critical problems in architecture requiring large amounts of energy. In order to this challenge, environment-friendly architecture design is required. Especially, Application of solar energy as a clean energy source and one kind of renewable energy. Many sites however are mainly concentrated in the developed countries, and are scarcer within the developing world. Simple radiation estimation models using meteorologically observed input parameters are often used in the applications requiring rough estimations of solar radiation. In this paper, measurements of global solar radiation and cloud data hours in climatological locations in South Korea are used to develop an estimation in solar radiation. The results of measured data are compared with the results obtained from equations, internationally accepted correlations.

  • PDF

Impact of Horizontal Global Solar Radiation Calculation Modelson Building Energy Performance Analysis Considering Solar Heat Gain Coefficient and Window-to-wall Ratio (수평면 전일사량 산출모델이 일사열취득계수 및 창면적비를 고려한 건물 에너지 성능분석에 미치는 영향)

  • Kim, Kee Han;Oh, John Kie-Whan
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.39-47
    • /
    • 2014
  • Solar applications analysis and building energy performance depend on the quality of the solar resource data available. Unfortunately, most of the weather stations do not measure solar radiation data in Korea, as a reason many researchers have studied different solar radiation estimation models and suggested to apply them to various locations in Korea. In addition, they also studied the impact of hourly global solar radiation on energy performance of an office building by comparing the simulated building energy consumptions using four different weather files, one using measured, and three estimated solar radiation from different models, which are Cloud-cover Radiation Model (CRM), Zhang and Huang Model (ZHM), and Meteorological Radiation Model (MRM), and concluded that there was some impact on energy performance of the building due to the using different solar radiation models. However, the result cannot be applied to all other buildings since the simulated office building for that study only used limited building characteristics such as using fixed values of solar heat gain coefficient (SHGC) and window-to-wall ratio (WWR), which are significant parameters related to solar radiation that affect to the building energy consumptions. Therefore, there is a need to identify how the building energy consumption will be changed by varying these building parameters. In this study, the impact of one measured and three estimated global solar radiation on energy performance of the office building was conducted taking account of SHGC and WWR. As a result, it was identified that the impact of four different solar radiation data on energy performance of the office building was evident regardless SHGC and WWR changes, and concluded that the most suitable solar models was changed from the CRM/ZHM to the MRM as SHGC and WWR increases.

Analysis and Calculation of Global Hourly Solar Irradiation Based on Sunshine Duration for Major Cities in Korea (국내 주요도시의 일조시간데이터를 이용한 시간당전일사량 산출 및 분석)

  • Lee, Kwan-Ho;Sim, Kwang-Yeal
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.2
    • /
    • pp.16-21
    • /
    • 2010
  • Computer simulation of buildings and solar energy systems are being used increasingly in energy assessments and design. This paper discusses the possibility of using sunshine duration data instead of global hourly solar irradiation (GHSI) data for localities with abundant data on sunshine duration. For six locations in South Korea where global radiation is currently measured, the global radiation was calculated using Sunshine Duration Radiation Model (SDRM), compared and analyzed. Results of SDRM has been compared with the measured data on the coefficients of determination (R2), root-mean-square error (RMSE) and mean bias error (MBE). This study recommends the use of sunshine duration based irradiation models if measured solar radiation data is not available.