• Title/Summary/Keyword: Solar modules

Search Result 398, Processing Time 0.026 seconds

Performance characteristics of building-integrated transparent amorphous silicon PV system for a daylighting application (자연채광용 박막 투광형 BIPV 창호의 발전특성 분석 연구)

  • Yoon, Jong-Ho;Kim, Seok-Ge;Song, Jong-Wha;Lee, Sung-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.280-283
    • /
    • 2007
  • The first grid-connected, building-integrated transparent amorphous silicon photovoltaic installation has been operated since October 2004 in Yongin, Korea. The 2.2kWp transparent PV system was applied to the facade of entrance hall in newly constructed KOLON E&C R&D building. The PV module is a nominal 0.98m ${\times}$ 0.95m, 10% transparent, laminated, amorphous(a-Si) thin-film device rated at 44 Wp per module. To demonstrate the architectural features of thin film PV technologies for daylighting application, transparent PV modules are attached to the building envelope with the form of single glazed window and special point glazing(SPG) frames. Besides power generation, the 10% transmittance of a-Si PV module provides very smooth natural daylight to the entrance hall without any special shading devices for whole year. The installation is fully instrumented and is continuously monitored in order to allow the performance assessment of amorphous silicon PV operating at the prevailing conditions. This paper presents measured power performance data from the first 12 months of operation. For the first year, annual average system specific yield was just 486.4kWh/kWp/year which is almost half of typical amorphous silicon PV output under the best angle and orientation. It should be caused by building orientation and self-shading of adjacent mass. Besides annual power output, various statistical analysis was performed to identify the characteristics of transparent thin film PV system.

  • PDF

Design of a Stabilized Milling Machine for the Improved Precision Machining (가공정도 향상을 위한 Milling Machine의 안정화 설계)

  • Ro, Seung-Hoon;Lee, Min-Su;Park, Keun-Woo;Kang, Hee-Tae;Lee, Jong-Hyung;Yang, Seong-Hyeon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.14 no.2
    • /
    • pp.45-52
    • /
    • 2011
  • Since the most exclusive machines of the modern industries which require the nano precision rates are evolved from the machine tools, the design of the stable machine tool structure is very critical. Exclusive machines for the modern industries such as semiconductor, solar cell and LED have surface machining processes which are similar to the face cutting and grinding of conventional machine tools. This study was initiated to stabilize a milling machine structure and further to help design those exclusive machines which have similar machining mechanisms. The vibrations inherent to the machine tool structures hurt the precision machining as well as damage the longevity of the structures. There have been numerous researches in order to suppress the vibrations of machine tool structures using the extra modules such as actuators and dampers. In this paper, the dynamic properties are analyzed to obtain the natural frequencies and mode shapes of a machine tool structure which reflect the main reasons of the biggest vibrations under the given operating conditions. And the feasibility of improving the stability of the structure without using any additional apparatus has been investigated with minor design changes. The result of the study shows that simple changes based on proper system identification can considerably improve the stability of the machine tool structure.

소형위성 ETB에서의 전력계 기능시험

  • 윤영수;박종오;최종연;권재욱;안재철;조승원;김영윤
    • Bulletin of the Korean Space Science Society
    • /
    • 2003.10a
    • /
    • pp.91-91
    • /
    • 2003
  • 위성을 발사하기 전까지는 지상에서 EGSE(Electrical Ground Support Equipment)를 이용하여 충분한 시스템 단위의 위성체 기능 시험을 수행한다. KOMPSAT-2(Korea Multi-Purpose Satellite - 2)와 같은 소형 위성의 서브시스템 각각이 요구사항에서 제시하는 규격을 만족하는지 여부를 점검하는 단계에서 전력계 관련 서브시스템의 기능 시험도 EPS(Electrical Power Subsystem) Test Plan에 의해 순차적으로 수행한다. KOMPSAT-2 ETB(Engineering Test Bed)에서의 전력계 시험은 먼저 Test Fuse Modules Check를 수행하였다. 퓨즈 모듈은 PCU(Power Control Unit) 상에 설치되어 있는 장치로써 퓨즈 모듈의 입력과 출력 사이에 도통성 및 다른 출력과의 절연성을 검증한다. 다음으로 EGSE 중 PMTS(Power Monitor Test Set)와 PCU와의 직렬 인터페이스를 점검하는 PCU Interface Check를 수행하였다 시험절차서에 따라 PCU가 가지는 릴레이 스위치에 대하여 명령어를 보내어 릴레이의 동작 상태 및 출력 전압 등을 점검한다. 다음 단계에서는 DC Integration을 수행하여 ETB 하니스 중 전원 관련 라인을 점검하였다 PCU는 모든 위성체 하드웨어에 전력을 공급하는 장비로써 과전력으로부터 하드웨어를 보호하기 위하여 하니스를 연결하기 전에 우선적으로 시험한다. 다음으로는 ECU(EPS Control Unit)가 각각에 해당하는 하드웨어에 명령어를 보내어 전력계 전체적인 동작 상태 검증하는 EPS Hardware Command & Telemetry Checkout을 수행하였다. ECU는 전력계의 모든 하드웨어를 제어하고 그 상태를 모니터링하는 기능을 한다. PCU와의 인터페이스를 통하여 전력의 제어 및 분배에 관련되는 특성을 제어 및 모니터하며 DDC(Deploy Device Controller)는 ECU로부터 명령어를 받아서 arm 및 safe 상태에 대한 텔리 메트리 데이터를 제공한다 그리고, SAR(Solar Array Regulator)는 ECU로부터 Bypass Relay 및 ARM Relay에 관한 명령어를 받아 수행되며 그에 따른 텔리 메트리 데이터를 제공한다. 마지막으로 EPS 소프트웨어를 검증하는 EPS Software Verification을 수행하였다 전력계 소프트웨어의 설계의 검증 부분은 현재 설계 제작된 전력계 .소프트웨어의 동작 특성 이 위성 의 전체 운용개념과 연계하여 전력계 소프트웨어가 전력계 및 위성체의 요구조건을 만족시키는지를 확인하는데 있다. 전력계 운용 소프트웨어는 배터리의 충ㆍ방전을 효율적으로 관리해 3년의 임무 기간동안 위성체에 전력을 공급할 수 있도록 설계되어 있다

  • PDF

The verification about possibility of introducing Window to Floor Ratio as design index for building energy performance

  • Choi, Won-Ki;Lee, Yong-Jun;Lee, Hyun-Soo;Eom, Jae-Yong;Lee, Chung-Kook
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.23-28
    • /
    • 2017
  • Purpose: Many design index that are using in planning phase have been developed. The most popular things among them are Window to Wall Ratio and Surface to Volume Ratio. However there are some limits. Window to Wall Ratio cannot consider building size and Surface to Volume Ratio cannot do Window to Wall Ratio. Accordingly, in this paper, the Window to Floor Ratio was proposed that it can be considered both building size and Window to Wall Ratio. And analyzed correlation of energy demand. Method: For the test, 16 modules with the size of $6m{\times}6m{\times}4m$ were used to make 35 models with the same volume. The simulation was conducted to 945 cases using the window-to-wall ratio of 30, 50 and 70 % in three areas such as Seoul, Gwangju and Jeju and three kinds of windows. And IES_VE was used. Result: The findings above show that the Window to Floor Ratio that can be considered both building size and Window area have to become as design index. It was found out that design criteria with SHGC is necessary, not with the thermal performance (U-value). It is needed to additional analysis about residential building and the effect of 24-hours heating and cooling condition. It plans to carry out research to establish design indicators for climatic conditions in the country and building applications.

The grid-connected bidirectional PCS technology of the ESS (에너지 저장장치의 계통 연계형 양방향 PCS 기술)

  • Ko, Bong-Woon
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1280-1287
    • /
    • 2019
  • Grid-connected bidirectional PCS(Power Conditioning System) technology is a technology for implementing distributed renewable energy smart grid. And it is always charged by using power collected from solar modules and commercial grid power among vast smart grid systems, and stored when needed.It is a hybrid energy storage device that allows power to be released into the low voltage system. To this end, a PV input power converter with MPPT function, a bidirectional power converter for battery charging and discharging, and a DC Link input are output to a 3 phase 380V AC system, and if nessary, the bidirectional DC/DC converter We designed and developed a PCS with three power converter structures composed of inverters that perform battery charging. Currently, this system is applied to the site of Jeju, which is vulnerable to power outages and fire accidents.

ELECTRICAL GROUND SUPPORT EQUIPMENT (EGSE) DESIGN FOR SMALL SATELLITE

  • Park, Jong-Oh;Choi, Jong-Yoen;Lim, Seong-Bin;Kwon, Jae-Wook;Youn, Young-Su;Chun, Yong-Sik;Lee, Sang-Seol
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.3
    • /
    • pp.215-224
    • /
    • 2002
  • This paper describes EGSE design for the small satellite such like KOMPSAT-2 satellite. Recent design trend of small satellite and EGSE is to take short development time and less cost. For this purpose, the design for KOMPSAT-2 satellite and EGSE are not much modified from KOMPSAT-1 heritage. It means that it is able to be accommodated the verified hardware and software modules used in KOMPSAT-1 satellite program if possible. The objective of EGSE is to provide hardware and software for efficient electrical testing of integrated KOMPSAT-2 satellite in three general categories. (1) Simulators for ground testing (e.g. solar-simulation power, earth scenes, horizons and sun sensor). (2) Ground station type satellite data acquisition and processing test sets. (3) Overall control of satellite using hardline datum. In KOMPSAT (KOrea Multi-Purpose SATellite) program, KOMPSAT-2 EGSE was developed to support satellite integration and test activities. The KOMPSAT-2 EGSE was designed in parallel with satellite design. Consequently, the KOMPSAT-2 EGSE was based on the KOMPSAT-1 heritage since the spacecraft design followed the heritage. The KOMPSAT-2 baseline was elaborated by taking advantage of experience from KOMPSAT-1 program. The EGSE of KOMPSAT-2 design concept is generic modular design with preference in part selection with commercial off-the-shelf which were proven from KOMPSAT-1 programs, flexible/user friendly operational environment (graphical interface preferred), minimized new design and self test capability.

A Study on Development of PV Charging Module for Home Using Master-Slave Method (Master-Slave 방식을 적용한 가정용 PV Charging Module 개발에 관한 연구)

  • Chung, Doyoung;Cha, Insu;Jung, kyunghwan;Kim, Sungmin;Kim, Rakjun;Kang, Byungbok
    • Journal of Energy Engineering
    • /
    • v.29 no.1
    • /
    • pp.44-51
    • /
    • 2020
  • The importance of ESS has been emphasized due to stabilization of power demand due to deterioration of network reliability and expansion of renewable energy sources. ESS (Energy Storage System) stores the remaining power and uses it when necessary to meet the power demand, and build the ESS system mainly in conjunction with solar and wind power. In this paper, we propose a home PV Charging Module using the Master-Slave method which is effective for low insolation. After designing the module, Fast MPPT algorithm is applied to generate the maximum output from the nonlinear output characteristics of the PV modules. The average power value for the input of PV Charging Module was 296.90 W and the output power was 289.60 W, which averaged 97.54%.

Thermal Characteristic and Failure Modes and Effects Analysis for Components of Photovoltaic PCS (태양광 발전 PCS 구성부품에 대한 열적특성 및 고장모드영향분석)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Kim, Yoon-Bok
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.4
    • /
    • pp.1-7
    • /
    • 2018
  • This paper is analyzed for the thermal characteristics(1 year) of the 6 components(DC breaker, DC filter(including capacitor and discharge resistance), IGBT(Insulated gate bipolar mode transistor), AC filter, AC breaker, etc.) of a photovoltaic power generation-based PCS(Power conditioning system) below 20 kW. Among the modules, the discharge resistance included in the DC filter indicated the highest heat at $125^{\circ}C$, and such heat resulting from the discharge resistance had an influence on the IGBT installed on the rear side the board. Therefore, risk priority through risk priority number(RPN) of FMEA(Failure modes and effects analysis) sheet is conducted for classification into top 10 %. According to thermal characteristics and FMEA, it is necessary to pay attention to not only the in-house defects found in the IGBT, but also the conductive heat caused by the discharge resistance. Since it is possible that animal, dust and others can be accumulated within the PCS, it is possible that the heat resulting from the discharge resistance may cause fire. Accordingly, there are two options that can be used: installing a heat sink while designing the discharge resistance, and designing the discharge resistance in a structure capable of avoiding heat conduction through setting a separation distance between discharge resistance and IGBT. This data can be used as the data for conducting a comparative analysis of abnormal signals in the process of developing a safety device for solar electricity-based photovoltaic power generation systems, as the data for examining the fire accidents caused by each module, and as the field data for setting component management priorities.

An Experimental Comparison Study of PVT Water and PVT Air Modules for Heat and Power Co-Generation (태양 열 전기 복합생산 PVT Water and PVT Air 모듈의 실험적 성능비교 연구)

  • Lee, Kwang-Seob;Putrayudha S., Andrew;Kang, Eun-Chul;Lee, Euy-Joon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.559-564
    • /
    • 2014
  • The development of photovoltaic-thermal (PVT) technology has been introduced in recent years specifically to increase PV efficiency. One of the characteristics of PV systems is that the electricity generation increases as the solar radiation increases whereas the efficiency decreases because of high surface temperatures. Using a photovoltaic-thermal system, the surface temperature can be decreased by capturing the excess heat and the efficiency can be increased due to these characteristics. In this paper, three cases are introduced : 1) PV_r as the reference case, 2) PVT_a, which uses air as a heat source, and 3) PVT_w, which uses water as a heat source. Experiments were performed, analyzed, and compared to examine the effect of the PVT type on the efficiency of the system. The results showed that ETC($%/^{\circ}C$) efficiency of the PVT cases was increased versus the reference case due to decreasing surface temperature. Total efficiencies, which are electrical efficiency and thermal efficiency, for each PVT are tested and found to be 12.22% for PV_r, 29.50% for PVT_a, and 68.74% for PVT_w.

Numerical Study on the Thermal Design of Lunar Terrain Imager System Loaded on the Korea Pathfinder Lunar Orbiter (시험용 달 궤도선의 광학탑재체 시스템 열설계에 대한 수치해석적 연구)

  • Kim, Taig Young;Chang, Su-Young;Heo, Haeng-Pal
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.4
    • /
    • pp.309-318
    • /
    • 2019
  • The thermal design of the Lunar Terrain Imager (LUTI) on the Korean Pathfinder Lunar Orbiter (KPLO) was performed and the soundness of the thermal design was verified by thermal analysis. The thermal environment of the lunar mission orbit should be reflected in the thermal design because the IR radiation of the lunar surface is important, unlike the earth orbit. The components or modules exposed to the outside of the satellite are insulated with MLI as much as possible, but the camera tube and the radiator are functionally exposed, so the thermal shield using the concept of radiation shape factor is mounted on the front to mitigate IR radiation. The IR emissivity is important in the front side of the radiator that receives little solar radiation, and components that are susceptible to thermal deformation such as the tube use a radiation heater to minimize the temperature gradient. Through the investigation of computational results, it was confirmed that the thermal design of LUTI is stable in various situations.