• Title/Summary/Keyword: Solar irradiance

Search Result 237, Processing Time 0.034 seconds

Analysis of cloud cover and solar irradiance of typical meteorological data (표준기상데이터의 운량과 일사량 데이터 비교 분석)

  • Yoo, Ho-Chun;Lee, Kwan-Ho;Kang, Hyun-Gu
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.330-335
    • /
    • 2009
  • kDomestic studies on meteorologicaldata have been carried out, however they were mostly not constant but limited to fragment compilation. The studies on solar energy, among others, have been relatively active but the measurement of solar irradiance is also limited to some extent. This study, in an effort to identify the difference in data between solar radiance and cloud cover, was intended to compare and analyze the typical meteorological data developed by Korean Solar Energy Society with the solar irradiance calculated using the typical meteorological data and cloud cover data provided by current simulation program. Monthly average solar irradiance from the meteorological data (ISO TRY) of Korea's typical meteorological data which was actuallymeasured appeared to be far below the monthly solar irradiance from the American Department of Energy. The solar irradiance calculated based on cloud cover indicates very limited difference between the two data, so the solar irradiance measured by Korean typical metrologicaldata (ISO TRY) indicated the similar value, which demonstrates the solar irradiance data from Korean Meteorological Administration is more accurate than those US National Weather Center.

  • PDF

Simulation of Solar Irradiance Distribution Under Agrivoltaic Facilities (영농형 태양광 발전 시설 하부의 일사량 분포 모의)

  • Jeong, Young-Joon;Lee, Sang-Ik;Lee, Jong-Hyuk;Seo, Byung-Hun;Kim, Dong-Su;Lee, Jimin;Choi, Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.2
    • /
    • pp.1-13
    • /
    • 2022
  • Agrivoltaic facility is the composite system that the solar panel is installed above the farmland, and it enables crop and electricity production simultaneously. Solar panels of the agrivoltaic facilities can block and reduce the amount of solar irradiance arriving at the farmland, but it can help the crop growth by preventing excessive solar irradiance. Therefore, to clarify how the agrivoltaic facilities affect the crop growth, precise solar irradiance distribution under the solar panel should be modeled. In this study, PAR (photosynthetically active radiation), radiation from 400 to 700 nm, which crops usually use to grow, was extracted from the total irradiance and its distribution model under various conditions was developed. Monthly irradiance distributions varied because the elevation of the sun was changed over time, which made the position changed that the local maximum and minimum irradiance appear. The higher panel height did not cause any significant difference in the amount of irradiance reaching below the solar panel, but its distribution became more uniform. Furthermore, the panel angles with the most irradiance arriving below the solar panel were different by month, but its difference was up to 2%p between the irradiance with 30° angle which is usually recommended in Korea. Finally, the interval between panels was adjusted; when the ratio of the length of the panel to the empty space was 1:2, the irradiance of 0.719 times was reached compared to when there was no panel, 0.579 times for 1:1 and 0.442 times for 2:1.

Analysis of Clear Sky Index Defined by Various Ways Using Solar Resource Map Based on Chollian Satellite Imagery (천리안 위성 영상 기반 태양자원지도를 활용한 다양한 정의에서의 청천지수 특성 분석)

  • Kim, Chang Ki;Kim, Hyun-Goo;Kang, Yong-Heack;Yun, Chang-Yeol
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.3
    • /
    • pp.47-57
    • /
    • 2019
  • Clear sky indices were estimated by various ways based on in-situ observation and satellite-derived solar irradiance. In principle, clear sky index defined by clear sky solar irradiance indicates the impacts of cloud on the incoming solar irradiance. However, clear sky index widely used in energy sciences is formulated by extraterrestrial irradiance, which implies the extinction of solar irradiance due to mainly aerosol, water vapor and clouds drops. This study examined the relative difference of clear sky indices and then major characteristics of clear sky irradiance when sky is clear are investigated. Clear sky is defined when clear sky index based on clear sky irradiance is higher than 0.9. In contrast, clear sky index defined by extraterrestrial irradiance is distributed between 0.4 and 0.8. When aerosol optical depth and air mass coefficient are relative larger, solar irradiance is lower due to enhanced extinction, which leads to the lower value of clear sky index defined by extraterrestrial irradiance.

Recent Changes in Solar Irradiance, Air Temperature and Cloudiness at King Sejong Station, Antarctica (남극 세종기지에서 최근 태양 복사, 기온과 운량의 변화)

  • Lee, Bang Yong;Cho, Hi Ku;Kim, Jhoon;Jung, Yeon Jin;Lee, Yun Gon
    • Atmosphere
    • /
    • v.16 no.4
    • /
    • pp.333-342
    • /
    • 2006
  • The long-term trends of global solar irradiance, air temperature, specific humidity and cloudiness measured at King Sejong station, Antarctica, during the period of 1988-2004, have been investigated. A statistically insignificant decrease, -0.21 $Wm^{-2}yr^{-1}$ (-0.26 %$yr^{-1}$, P<0.5) in global solar irradiance was found in an analysis from the time series of the monthly mean values, except for the increasing trends only in two months of January and June. The trends in irradiance are directly and inversely associated with the cloudiness trends in annual and monthly means. The trends in surface air temperature show a slight warming, $0.03^{\circ}Cyr^{-1}$ (1.88 %$yr^{-1}$, P<0.5) on the annual average, with cooling trend in the summer months and the warming in the winter. The exact relationship, if any, between the irradiance and temperature trends is not known. No significant tendency was found in specific humidity for the same periods. Recent (1996-2004) erythermal ultraviolet irradiance shows decreasing trend in annual mean, -0.15 $mWm^{-2}yr^{-1}$ (-1.18 %$yr^{-1}$, P<0.1) which is about five times the trends of global solar irradiance. The ratio of erythermal ultraviolet to global solar irradiance shows remarkable seasonal variations with annual mean value of 0.01 % and a peak in October and November, showing the increase of ultraviolet irradiance resulting from the Antarctic ozone hole. The sensitivity of global solar irradiance to the change in cloudiness is roughly $13%oktas^{-1}$ which is about twice of the value at the South Pole due to the difference in the average surface reflectance between the two stations. Much more sensitive values of $59%oktas^{-1}$ was found for erythermal UV irradiance than for the global solar irradiance.

Variation of Solar Photovoltaic Power Estimation due to Solar Irradiance Decomposition Models (일사량 직산분리 모델에 따른 표준기상연도 데이터와 태양광 발전 예측량의 불확실성)

  • Jo, Eul-Hyo;Lee, Hyun-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.3
    • /
    • pp.81-89
    • /
    • 2019
  • Long-term solar irradiance data are required for reliable performance evaluation and feasibility analysis of solar photovoltaic systems. However, measurement data of the global horizontal irradiance (GHI) are only available for major cities in Korea. Neither the direct normal irradiance (DNI) nor the diffuse horizontal irradiance (DHI) are available, which are also needed to calculate the irradiance on the tilted surface of PV array. It is a simple approach to take advantage of the decomposition model that extracts DNI and DHI from GHI. In this study, we investigate variations of solar PV power estimation due to the choice of decomposition model. The GHI data from Korea Meteorological Administration (KMA) were used and different sets of typical meteorological year (TMY) data using some well-known decomposition models were generated. Then, power outputs with the different TMY data were calculated, and a variation of 3.7% was estimated due to the choice of decomposition model.

The effects of clouds on enhancing surface solar irradiance (구름에 의한 지표 일사량의 증가)

  • Jung, Yeonjin;Cho, Hi Ku;Kim, Jhoon;Kim, Young Joon;Kim, Yun Mi
    • Atmosphere
    • /
    • v.21 no.2
    • /
    • pp.131-142
    • /
    • 2011
  • Spectral solar irradiances were observed using a visible and UV Multi-Filter Rotating Shadowband Radiometer on the rooftop of the Science Building at Yonsei University, Seoul ($37.57^{\circ}N$, $126.98^{\circ}E$, 86 m) during one year period in 2006. 1-min measurements of global(total) and diffuse solar irradiances over the solar zenith angle (SZA) ranges from $20^{\circ}$ to $70^{\circ}$ were used to examine the effects of clouds and total optical depth (TOD) on enhancing four solar irradiance components (broadband 395-955 nm, UV channel 304.5 nm, visible channel 495.2 nm, and infrared channel 869.2 nm) together with the sky camera images for the assessment of cloud conditions at the time of each measurement. The obtained clear-sky irradiance measurements were used for empirical model of clear-sky irradiance with the cosine of the solar zenith angle (SZA) as an independent variable. These developed models produce continuous estimates of global and diffuse solar irradiances for clear sky. Then, the clear-sky irradiances are used to estimate the effects of clouds and TOD on the enhancement of surface solar irradiance as a difference between the measured and the estimated clear-sky values. It was found that the enhancements occur at TODs less than 1.0 (i.e. transmissivity greater than 37%) when solar disk was not obscured or obscured by optically thin clouds. Although the TOD is less than 1.0, the probability of the occurrence for the enhancements shows 50~65% depending on four different solar radiation components with the low UV irradiance. The cumulus types such as stratoculmus and altoculumus were found to produce localized enhancement of broadband global solar irradiance of up to 36.0% at TOD of 0.43 under overcast skies (cloud cover 90%) when direct solar beam was unobstructed through the broken clouds. However, those same type clouds were found to attenuate up to 80% of the incoming global solar irradiance at TOD of about 7.0. The maximum global UV enhancement was only 3.8% which is much lower than those of other three solar components because of the light scattering efficiency of cloud drops. It was shown that the most of the enhancements occurred under cloud cover from 40 to 90%. The broadband global enhancement greater than 20% occurred for SZAs ranging from 28 to $62^{\circ}$. The broadband diffuse irradiance has been increased up to 467.8% (TOD 0.34) by clouds. In the case of channel 869.0 nm, the maximum diffuse enhancement was 609.5%. Thus, it is required to measure irradiance for various cloud conditions in order to obtain climatological values, to trace the differences among cloud types, and to eventually estimate the influence on solar irradiance by cloud characteristics.

Characteristics and Error Analysis of Solar Resources Derived from COMS Satellite (기상청 천리안 위성 자료를 활용한 태양광 기상자원 특성 및 오차 분석)

  • Lee, Su-Hyang;Kim, Yeon-Hee
    • Atmosphere
    • /
    • v.30 no.1
    • /
    • pp.59-73
    • /
    • 2020
  • The characteristics of solar resources in South Korea were analyzed by comparing the solar irradiance derived from COMS (Communication, Ocean and Meteorological Satellite) with in-situ ground observation data (Pyranometer). Satellite-derived solar irradiance and in-situ observation showed general coincidence with correlation coefficient higher than 0.9, but the satellite observations tended to overestimate the radiation amount compared to the ground observations. Analysis of hourly and monthly irradiance showed that relatively large discrepancies between the satellite and ground observations exist after sunrise and during July~August period which were mainly attributed to uncertainties in the satellite retrieval such as large atmospheric optical thickness and cloud amount. But differences between the two observations did not show distinct diurnal or seasonal cycles. Analysis of regional characteristics of solar irradiance showed that differences between satellite and in-situ observations are relatively large in metrocity such as Seoul and coastal regions due to air pollution and sea salt aerosols which act to increase the uncertainty in the satellite retrieval. It was concluded that the satellite irradiance data can be used for assessment and prediction of solar energy resources overcoming the limitation of ground observations, although it still has various sources of uncertainty.

A Study on Solar Radiation and Efficient Solar Panel of Icosahedron-based Hemispherical Dome (정20면체기반 반구형 돔의 일사량과 효율적인 솔라패널에 관한 연구)

  • Shon, Su-Deok;Lee, Don-Woo;Lee, Seung-Jae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.1
    • /
    • pp.53-64
    • /
    • 2016
  • Solar power is being spotlighted recently as a new energy source due to environmental problems and applications of solar power to curved structures are increasing. Solar panels installed on curved surfaces have different efficiencies depending on its position and the efficient positioning of solar panels plays a critical role in the design of solar power generation systems. In this study, the changing characteristics of solar irradiance were analyzed for hemispherical dome with a large curvature and the positioning of solar panels that can efficiently utilize solar energy was investigated. With an icosahedron-based hemispherical dome consisting of triangular elements as target model, a program for calculating solar irradiance using a normal vector of the solar module on each face was developed. Furthermore, the change of solar irradiance according to the sun's path was analyzed by time and season, and its effects on shades were also examined. From the analysis results, the effective positioning could be determined on the basis of the efficiency of the solar panels installed on the dome surfaces on solar irradiance.

A Thermal Flow Analysis for an Optimal shape of Solar Lamp Bank (최적의 램프뱅크형태를 결정하기 위한 열유동 해석)

  • Baek, Sang-Hwa
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.82-89
    • /
    • 2012
  • This study is on the thermal flow analysis to select an optimal shape of solar lamp bank. Solar Lamp bank is designed by the lamp bank design program based on point light source theory. The reliability of the program for lamp bank design is verified through irradiance variation experiments of a kind of lamp according to horizontal distance. Solar lamp bank facilitates heat distribution and satisfies the irradiance in the three wave length which test guidelines require. Among the 4 kinds of lamp bank, since lamp bank type D satisfies uniformity ${\pm}10%$ and also doesn't exceed total irradiance 1,232 $W/m^2$, type D is finally selected.

An Experimental Study on Daily Efficiency of Solar Collector with Heating Loads of Solar Water Heating System (부하를 고려한 태양열온수시스템의 일간 집열효율에 대한 실험적 분석)

  • Lee, Kyoung-Ho;Joo, Hong-Jin;Yoon, Eung-Sang;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.19-27
    • /
    • 2012
  • This paper describes an experimental study on efficiency of solar collector in solar water heating system connected to hourly water heating load. In general, the functional form of solar efficiency is expressed as a function of fluid temperature entering solar collector, ambient temperature, and solar irradiance. When energy saving from solar heating of water heating system is analyzed on along-term basis such as one year with given solar irradiance data, simplified analysis is more convenient han detailed system simulation for quick assessment. However, the functional form of the efficiency is not convenient for approximately simplified energy analysis because the inlet temperature can be obtained through a detailed system simulation. In the study, solar collector efficiency is obtained with various daily water heating load sand daily solar irradiance using experimental tests. The study also considers large residential buildings such as apartment buildings for application of solar water heating systems. From test results, it is found that daily solar collector efficiency is proportional to daily water heating loads and daily solar irradiance. The data obtained from the study can be utilized to find a functional relation between daily solar irradiance and daily heating load in stead of collector inlet temperature for application of solar collector efficiency to long-term approximated energy analysis of solar heating system.