• Title/Summary/Keyword: Solar insolation

Search Result 254, Processing Time 0.033 seconds

A Detailed Analysis of Solar Energy Resources in Korean Peninsula Using a Satellite (인공위성을 이용한 한반도 태양에너지자원 상세 정밀분석)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.68-76
    • /
    • 2012
  • Since the solar energy resource is the main input for sizing any solar energy utilization system, it is essential to utilize the solar radiation data as an application and development of solar energy system increase. It will be necessary to understand and evaluate the insolation data. The Korea Institute of Energy Research(KIER) has begun collecting horizontal global insolation data since May, 1982 at 16 different locations in Korea and for the more detailed analysis, images taken by geostationary satellite may be used to estimate solar irradiance fluxes at earth's surface. It is based on the empirical correlation between a satellite derived cloud index and the irradiance at the ground. From the results, the measured data has been collected at 16 different stations and estimated using satellite at 44 different stations over the Korean peninsula from 1982 to 2010. The Result of analysis shows that the annual-average daily global radiation on the horizontal surface is 3.66 $kWh/m^2/day$ and estimated solar radiation fluxes show reliable results for estimating the global radiation with average deviation of -7.2 to +3.7 % from the measured values.

Variation of the Insolation by Cloud Cover over Pusan in Korea (釜山地方의 雲量에 따른 日射量의 變化)

  • Cho, Byoung-Gil;Lee, Bu-Yong;Moon, Sung-Euii
    • Journal of Environmental Science International
    • /
    • v.4 no.1
    • /
    • pp.13-18
    • /
    • 1995
  • In order to examine the effect on the insolation of cloud cover, we analyzed the data of the insolation, cloud cover and surface air pressure in Pusan during the period of 1991. 10 - 1993.1. At first, we investigate the atmospheric transmissivity A(t) using the Beer's law at clear skies. The atmospheric transmissivity is characterized by cold season high and warn season low. From this atmospheric transmissivity, the empirical formula that shows the variation of the insolation due to the cloud cover is obtained. The result formula is I : l0 A(tn)·( 0.7-0.05×m ). 1 is the insolation that reaches the surface when cloud cover is m and to is solar constant. Although the result is some rough it seems meaningful that the estimation of insolation can be made only from the routine data.

  • PDF

A Revaluation Study of Cheju-Do Solar Insolation Data by Field Measurement (실측에 의한 제주도 일사량자원의 평가)

  • Jo, Dok-Ki;Lee, Tae-Kyu;Chun, Il-Soo;Cho, Suh-Hyun;Auh, Chung-Moo
    • Solar Energy
    • /
    • v.13 no.1
    • /
    • pp.67-74
    • /
    • 1993
  • Solar radiation intensity in Cheju-Do has been measured and analyzed to study the its characteristic and the possibility of the alternative energy, This work will also support the on-going project "Clean Enertopia in Cheju" which is strongly driven by government recently. The results of this project indicate that 1) Insolation in Cheju-Do is 10% lower than Southern coastal area. 2) A significant difference of insolation is observed between western and eastern part of Cheju-Do.

  • PDF

Estimation of Solar Radiation Distribution in Korea Using a Satellite (인공위성을 이용한 국내 일사량 분포 예측)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.2
    • /
    • pp.99-106
    • /
    • 2011
  • Since the solar energy resource is the main input for sizing any solar photovoltaic system, it is essential to utilize the solar radiation data as an application and development of solar energy system increase. It will be necessary to understand and evaluate the insolation data. The Korea Institute of Energy Research(KIER) has begun collecting horizontal global insolation data since May, 1982 at 16 different locations in Korea and for the more detailed analysis, images taken by geostationary satellite may be used to estimate solar irradiance fluxes at earth"s surface. It is based on the empirical correlation between a satellite derived cloud index and the irradiance at the ground. From the results, the measured data has been collected at 16 different stations and estimated using satellite at 23 different stations over the South Korea from 1982 to 2009. The Result of analysis shows that the annual-average daily global radiation on the horizontal surface is 3.56 kWh/ $m^2$/day and estimated solar radiation fluxes show reliable results for estimating the global radiation with average deviation of -7.27 to +3.65% from the measured values.

Long-term thermal performance of evacuated tubular solar collector for demonstration system (태양열 실증시스템의 진공관형 태양열 집열기 장기 열성능)

  • Lee, Ho;Joo, Hong-Jin;Yoon, Eung-Sang;Kim, Sang-Jin;Kwak, Hee-Youl
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.104-110
    • /
    • 2008
  • This paper presents demonstration study results derived through field testing of a part load solar energized cooling system for the library of a cultural center building located in Gwangju, Korea. First operating demonstration system was set up in Gwangju in 2005. These system comprises the $200m^2$ evacuated tubular solar collector, a $6m^3$ heat storage tank. In a 2006, daily average of insolation showed about $506W/m^2$, the solar collector efficiency was 44%. In a 2007, daily average of insolation showed about$507W/m^2$, the solar collector efficiency was 42%. As a result, evacuated tubular solar collector kept the high efficiency for two years.

  • PDF

Simulation of Radiative Property Effects on Radiant Cooling of Opaque Surface (비 투과면 복사 냉각에 대한 복사 물성의 영향 예측)

  • Byun, Ki-Hong
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.32-38
    • /
    • 2009
  • The effects of surface radiative properties on the radiant cooling of opaque surfaces under clear sky condition are studied. Two types of surfaces, one gray and the other selective, are compared. For the nighttime cooling, black surface gives the lowest plate temperature and on the other hand the ideal selective surface gives the highest temperature. The reverse is true when there is an insolation. Equivalent radiative heat transfer coefficient of radiant cooling without convection is about $1{\sim}7\;W/m^2-K$ for the range of values studied. The surface with black within the $6{\sim}13\;{\mu}m$ band else zero emissivity could be regarded as a black surface for the nighttime radiant cooling purposes. However, lower band limit of $4\;{\mu}m$ is preferred to $6\;{\mu}m$ for small insolation situations.

A Study of New Highly Efficient MPPT Control Algorithm (새로운 고효율 MPPT 제어 알고리즘 고찰)

  • Yu, Gwon-Jong;Jung, Young-Seok;Choi, Ju-Yeop
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.3
    • /
    • pp.11-20
    • /
    • 2002
  • This paper proposed a MPPT(Maximum Power Point Tracking) control algorithm for PV(Photovoltaic) array based on a modified constant voltage control MPPT algorithm at low insolation. This method which combined a reference voltage control and a constant voltage control algorithm. In contrast to the typical conventional MPPT algorithm, the proposed method have been obtained high efficiency and good performance in all insolation intensity. The proposed algorithm is verified through simulation and experiment.

A MPPT Control of Photovoltaic System for Current ripple reduce (전류리플 저감을 위한 태양광발전시스템의 최대출력점추적제어)

  • Chung, Choon-Byeong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.496-499
    • /
    • 2006
  • The solar cells should be operated at the maximum power point because its output characteristics are greatly fluctuate on the variations of insolation, temperature and loads. To obtain maximum power from solar cell, photovoltaic system cell power system usually requires maximum power point tracking controller. This paper propose Maximum power point tracking method using zero slope of differential value of maximum power. The power compare method traces to maximum power point rapidly but oscillate on the maximum power point largely, when quantity insolation variation is big. The power compare method is traces to maximum power point slowly but oscillate maximum point on the maximum power point smally, when quantity insolation variation is small. To solve two problem of the power compare method, designed zero slope of differential value of maximum power.

  • PDF

The Effect of Urban Trees on Residential Solar Energy Potential (도심 수목이 분산형 주거 태양광에너지 잠재량에 미치는 영향)

  • Ko, Yekang
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.1
    • /
    • pp.41-49
    • /
    • 2014
  • This study spatially assesses the impact of trees on residential rooftop solar energy potential using urban three-dimensional models derived from Light Detection and Ranging(LiDAR) data in San Francisco, California. In recent years on-site solar energy generation in cities has become an essential agenda in municipal climate action plans. However, it can be limited by neighboring environments such as shade from topography, buildings and trees. Of all these effects, the impact of trees on rooftop photovoltaics(PVs) requires careful attention because improper situation of solar panels without considering trees can result in inefficient solar energy generation, tree removal, and/or increasing building energy demand and urban heat island effect. Using ArcMap 9.3.1, we calculated the incoming annual solar radiation on individual rooftops in San Francisco and the reduced insolation affected by trees. Furthermore, we performed a multiple regression analysis to see what attributes of trees in a neighborhood(tree density, tree heights, and the variance of tree heights) affect rooftop insolation. The result shows that annual total residential rooftops insolation in San Francisco is 18,326,671 MWh and annual total light-loss reduction caused by trees is 326,406 MWh, which is about 1.78%. The annual insolation shows a wide range of values from $34.4kWh/m^2/year$ to $1,348.4kWh/m^2/year$. The result spatially maps the locations that show the various levels of impact from trees. The result from multiple regression shows that tree density, average tree heights and the variation of tree heights in a neighborhood have statistically significant effects on the rooftop solar potential. The results can be linked to municipal energy planning in order to manage potential conflicts as cities with low to medium population density begin implementing on-site solar energy generation. Rooftop solar energy generation makes the best contribution towards achieving sustainability when PVs are optimally located while pursuing the preservation of urban trees.

A Study on the Instrumentation and Valuation of Photovoltaic Energy Utilization System (태양광발전 에너지이용시스템의 계측과 평가에 관한 연구)

  • Chung, Heun-Sang;Baek, Hyung-Lae;Cho, Geum-Bae;Kim, Dong-Hwi;Kim, Dae-Gon;You, Gwon-Jong
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.496-499
    • /
    • 1991
  • Photovoltaic system has very low energy conversion efficiency and the output characteristics of solar cell is varied by the Insolation quantity and the temperature. In order to improve the efficiency of photovoltaic system, the energy which has got from solar cell must be use maximum. In this paper, it was stimultaneous executed both MPPT control and instrumentation in order that the operating point of solar cell is located maximum power point, using the PWM inverter and micro-computer, which is for the purpose of acquiring maximum power from the solar cell. As a result, maximum power point tracking had carried out and the efficiency of photovoltaic system improved, even if insolation quantity and the temperature are varied.

  • PDF