• Title/Summary/Keyword: Solar cell connection

Search Result 61, Processing Time 0.023 seconds

Analysis and Control of Series$\cdot$Parallels Connection Characteristics for Virtual Implementation of 50[W] Solar Cell Module (50[W]급 태양전지의 가상 구현을 위한 모듈의 직$\cdot$병렬 연결 특성 해석 및 제어)

  • Han J. M.;Ryu T. G.;Gho J. S.;Choe G. H.
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.53-57
    • /
    • 2002
  • The solar energy is purity and infinity. Solar power converter were used to convert the electrical energy from the solar arrays to a stable and reliable power source. So many countries research this solar energy system The photovoltaic system is construct many solar cell array. In this paper, new implementation solar system was showed buck converter that V-I curve produced. This system can be used to study the short-term and long-term performances of solar cell and efficiency. This system is a far more cost effective and reliable replacement for field and outdoor flight testing. Study of buck converter, analysis and control series or parallels connection characteristics of solar cell way.

  • PDF

A Characteristic Study on the Dye-Sensitized Solar Cell by the Shadow Effect (그림자 효과에 의한 염료감응형 태양전지의 특성연구)

  • Kim, Hee-Je;Lee, Jeong-Gee;Lee, Kyung-Jun;Prabakar, Prabakar;Sin, Dong-Seoul;Chae, Won-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.144-151
    • /
    • 2010
  • The shadowing effects lead to the serious power losses of the PV module. The shadowing effects are caused by several factors such as leafs, dust, antenna and clouds. The dye-sensitized solar cells are more economical than the conventional silicon solar cell that's why the dye-sensitized solar cells are recently focused on. We carried out research on the efficiency of the dye-sensitized solar cell depending on the level of shadow changing the formula of the circuit. The research on the efficiency of the large dye-sensitized solar cell depending on the level of shadow focused on commercialization was carried out. As the results, it is known that the series and parallel connection method is the best choice for the least losses of PV module assemblies. It is especially known that one more series connection is the best choice for the least losses about shadowing effects and current losses in the series and parallel connection.

The Analysis of the Current Loss in the Parallel Connection of Dye-sensitized Solar Cells (염료감응형 태양전지의 병렬 연결에서 발생하는 전류 손실 분석)

  • Seo, Hyun-Woong;Lee, Kyoung-Jun;Son, Min-Kyu;Hong, Ji-Tae;Kim, Hee-Je
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.412-415
    • /
    • 2008
  • In a research on the practical dye-sensitized solar cell, a study on a large module have preference because module must be able to generate the proper current that is possible to convert electrically. So the parallel connection of dye-sensitized solar cells which outputs a large current easily is essential. However, there is a current loss in a paralle connection of dye-sensitized solar cells and the loss becomes larger according to increasing the number of parallel connection. In this study, we analyzed the cause of the current loss in the parallel connection by using the equivalent circuit analysis. One DSC used in this experiment had an active area $8cm^2$(4.62cm$\times$1.73cm) and it attained a conversion efficiency of 5.43% under 1 sun illumination ($P_{in}$ of 100 mW/$cm^2$) using a solar simulator.

  • PDF

Photovoltaic Properties of Tandem Structure Consisting of Quantum Dot Solar cell and Small Molecule Organic Solar cell

  • Jang, Jinwoong;Choi, Geunpyo;Yim, Sanggyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.249.2-249.2
    • /
    • 2015
  • Connecting two or more sub-cells is a simple and effective way of improving power conversion efficiency (PCE) of solar cells, and the theoretical efficiency of this tandem cell is known to reach 85~88% of the sum of the sub-cell's efficiencies. There are two ways of connecting sub-cells in the tandem structure, i.e. parallel and series connection. The parallel connection can increase the short circuit current (Jsc) and the series connection can increase the open circuit voltage (Voc). Although various tandem structures have been studied, the full use of incident light and optimization of cell efficiency is still limited. In this work, we designed series tandem solar cells consisting of lead sulfide (PbS) quantum dots/zinc oxide-based QDSC and zinc phthalocyanine (ZnPc)/C60-based small molecule OSCs. It is expected that the loss of the incident light is minimized because the absorption range of the PbS quantum dots and ZnPc is significantly different, and the Voc increases according to the Kirchhoff's law.

  • PDF

The Analysis of missmatch with resistance on Si-PV module (결정질 태양전지 모듈 내부 저항의 Missmatch 분석)

  • Ji, Yang-Geun;Kong, Ji-Hyun;Kong, Gi-Hwan;Yu, Gwon-Jong;Won, Chang-Sub;Ahn, Hyung-Geun;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.98-103
    • /
    • 2009
  • In this paper, we test the electrical resistance of flat wire in the PV module. normally solar cell has two kind of flat wire(inter connection ribbon and bus bar ribbon). we found the phenomenon that has a unbalance with resistance when we make a wiling between of string. So, we measurement the resistance of flat wire each other. and analysis of missmatch with resistance between flat wires on PV module. next to survey of IR picture on missmatch flat wire samples for analyze of missmatch with current in the wire. and we perform IR test with solar cell that has a connection with flat wire for test the effect of missmatch resistance on solar cell. Finally we perform the Dark I-V test for survey of effect by the unbalance of resistance. By the result of Dark I-V test, the series resistance of existing connection sample is large more then innovated connection sample.

  • PDF

Controller Design of Stand-Alone Photovoltaic System with Charge-Discharge Controller for Remote lsland Power Supply

  • Kang, Ki-Hwan;Yu, Gwon-Jong;Song, Jinsoo;Jeong, Young-Seok;Kang, Ki-Hwan;Lee, Byoung-Ku;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.972-977
    • /
    • 1998
  • This paper deals with stand-alone Photovoltaic system(SPVS) with charge and discharge controller. Main power source of SPVS are generally solar cell and battery. Therefore SPVS can be classified into variable types in accordance with connection method between battery and solar cell array. Mainly used one of them is direct connection type which has advantages such as simple structure and simple controller. However most big drawback of this system is energy loss by voltage disharmony between solar cell array and battery. Therefore SPVS with charge and discharge controller which can operate solar cell array at maximum power point is designed and experimented with a laboratory prototype.

  • PDF

Design of Stand-Alone Photovoltaic System with Charge-Discharge Controller (충방전 제어기를 이용한 독립형 태양광 발전시스템의 설계)

  • 김홍성;유권종;송진수;이병구;정영석;강기환;최규하
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.103-108
    • /
    • 1998
  • This paper deals with stand-alone Photovoltaic system(SPVS) with charge and discharge controller. Main power source of SPVS are generally solar cell and battery. Therefore SPVS can be classified into variable types in accordance with connection type between battery and solar cell. Mainly used one of them is direct connection type which has advantages such as simple structure and simple controller. However most big drawback of this system is energy loss by voltage disharmony between solar cell and battery. Therefore SPVS with charge and discharge controller which can operate solar cell at maximum power point is designed and analyzed by simulation in this paper.

  • PDF

The Control Algorithm of Power-conditioner for Stand-alone PV System (독립형 PV시스템용 전력변환기 제어 알고리즘)

  • 정영석;강기환;김홍성;정명웅;유권종;송진수
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1998.10a
    • /
    • pp.209-215
    • /
    • 1998
  • This paper deals with stand-alone Photovoltaic system(SPVS) with charge and discharge controller. Main power source of SPVS are generally solar cell and battery. therefore SPVS can be classified into variable types in accordance with connection type between battery and solar cell. Mainly used one of them is direct connection type which has advantages such as simple structure and simple controller. However most big drawback of this system is energy loss by voltage disharmony between solar cell and battery. Therefore SPVS with charge and discharge controller which can operate solar cell at maximum power point is designed and analyzed by simulation in this paper.

  • PDF

Optimum Design of Dye-Sensitized Solar Module for Building-Integrated Photovoltaic Systems

  • Lee, Kyu-Seok;Kang, Man Gu
    • ETRI Journal
    • /
    • v.39 no.6
    • /
    • pp.859-865
    • /
    • 2017
  • This paper presents a method for determining the optimum active-area width (OAW) of solar cells in a module architecture. The current density-voltage curve of a reference cell with a narrow active-area width is used to reproduce the current density profile in the test cell whose active area width is to be optimized. We obtained self-consistent current density and electric potential profiles from iterative calculations of both properties, considering the distributed resistance of the contact layers. Further, we determined the OAW that yields the maximum efficiency by calculating efficiency as a function of the active-area width. The proposed method can be applied to the design of the active area of a dye-sensitized solar cell in Z-type series connection modules for indoor and building-integrated photovoltaic systems. Our calculations predicted that OAW increases as the sheet resistances of the contact layers and the intensity of light decrease.

Fire Prevention Systems for Photovoltaic Connection Panel (태양광 접속반의 화재 방지 시스템)

  • Han, Man Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.137-138
    • /
    • 2019
  • The photovoltaic module connects the voltage generated by the solar cell to the inverter. In the photovoltaic module, a diode is used to block the reverse voltage from the inverter to the solar cell. The heat generation of this diode is the main cause of the solar connection fire. In this paper, we propose a method to monitor the heat generation of diodes and prevent fire by using IoT devices.

  • PDF