• 제목/요약/키워드: Solar Thermal Power

검색결과 338건 처리시간 0.023초

우주선용 GaAs/Ge 태양전지에 관한 연구 (Study on GaAs/Ge Solar Cell for Space Use)

  • 이만근;박이준;최영희;전흥석
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국태양에너지학회, 한국에너지공학회 1993년도 춘계 공동학술발표회 초록집
    • /
    • pp.53-59
    • /
    • 1993
  • The interests on GaAs solar cell grown on Ge substrates as an alternative of GaAs substrate arises from its very close lattice parameters, very small difference in thermal expansion coefficients, and much higher fracture toughness between GaAs and Ge. In addition, for many space power application, it would be a most attractive solar cell with high radiation resistance of GaAs and high reliability for the reverse current damage of Ge, and expecting the theoretical efficiency limit of the tandem GaAs/Ge solar cell is 34% under 1 Sun, AM 0, and 28$^{\circ}C$ condition. In this report, we have reviewed the performance and the manufacturing technics of GaAs/Ge solar cell, and current status of research in GaAs/Ge solar cell.

  • PDF

국내 일사량 자원 특성분석 (A Characteristic Analysis of Solar Radiation Resources in Korea)

  • 조덕기;윤창열;김광득;강용혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.413-416
    • /
    • 2009
  • Since the solar radiation is main input for sizing any solar photovoltaic system and solar thermal power system, it will be necessary to understand and evaluate the insolation data. The Korea Institute of Energy Research(KIER) has begun collecting horizontal global insolation data since May, 1982 and direct normal insolation data since December 1992 at 16 different locations. Because of a poor reliability of existing data, KIER's new data will be extensively used by solar energy system users as well as by research institutes. Among some significant results, the yearly averaged horizontal global insolation was turned out 3.61 kWh/$m^2$/day and the yearly mean 5.38 kWh/$m^2$/day of the direct normal insolation was evaluated for clear days.

  • PDF

혹한기 지역에서의 자연순환형 태양열 시스템 동파방지 (Freeze Protection for Passive Solar Water Heating System in Bitter Cold Areas)

  • 권재욱;김종현;홍희기
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.41-46
    • /
    • 2011
  • In the present work, a new freeze protection method has been proposed for a natural circulation system of solar water heater. Though electrothermal wire is popularly used for the purpose, there are freezing troubles by wire cut-off and excessive electric power consumption. In the experimental device, hot water in a storage tank was circulated by a small pump and used to heat the outdoor pipes if the cold water pipe surface temperature falls lower than a set point. As a result, It was observed that there was no hot water waste while the solar water heating system operated without freeze and burst.

직달일사를 이용한 잠열축열식 바닥난방 시스템이 냉방부하에 미치는 영향에 대한 검토 (Effects of Phase Change Material Floor Heating Systems using Direct Solar Gain on Cooling Load)

  • 김수경
    • 한국태양에너지학회 논문집
    • /
    • 제33권3호
    • /
    • pp.9-16
    • /
    • 2013
  • In this research, the effect of a heating system, which is powered by direct solar energy accumulated in phase change material (PCM) as heat storage material installed on the floor surface, on the cooling load was studied. Cooling load of a test building designed for this research was measured with fan coil unit and factors affecting it were also estimated. Experiments were performed with and without PCM installed on the building floor to understand the effect of the PCM on the cooling load. Additionally, to confirm the experiments results, the prediction calculation formula by average outside temperature and integrated solar radiation was composed using multivariate regression model. The results suggested that the heating system with PCM on the floor surface has the potential to shift electric power peak by radiating heat, stored during the daytime in it, at night, not increasing the total cooling load much.

피어슨 상관계수를 이용한 적외선 열화상 안전 진단 시스템 개발 (The Development of Infrared Thermal Imaging Safety Diagnosis System Using Pearson's Correlation Coefficient)

  • 정종문;박성훈;이용식;김재현
    • 한국태양에너지학회 논문집
    • /
    • 제39권6호
    • /
    • pp.55-65
    • /
    • 2019
  • With the rapid development of the national industry, the importance of electrical safety was recognized because of a lot of new electrical equipment are installing and the electrical accidents have been occurring annually. Today, the electrical equipments is inspect by using the portable Infrared thermal imaging camera. but the most negative element of using the camera is inspected for only state of heating, the reliable diagnosis is depended with inspector's knowledge, and real-time monitoring is impossible. This paper present the infrared thermal imaging safety diagnosis system. This system is able to monitor in real time, predict the state of fault, and diagnose the state with analysis of thermal and power data. The system consists of a main processor, an infrared camera module, the power data acquisition board, and a server. The diagnostic algorithm is based on a mathematical model designed by analyzing the Pearson's Correlation Coefficient between temperature and power data. To test the prediction algorithm, the simulations were performed by damaging the terminals or cables on the switchboard to generate a large amount of heat. Utilizing these simulations, the developed prediction algorithm was verified.

열전소자를 활용한 도로구조물에서의 에너지 하베스팅 기초 연구 (Fundamental Study of Energy Harvesting using Thermoelectric Module on Road Facilities)

  • 이재준;김대훈;이강휘;임재규;이승태
    • 한국도로학회논문집
    • /
    • 제16권6호
    • /
    • pp.51-57
    • /
    • 2014
  • PURPOSES : An conventional method for electric power generation is converting thermal energy into mechanical energy then to electrical energy. Due to environmental issues such as global warming related with $CO_2$ emission etc., were the limiting factor for the energy resources which resulting in extensive research and novel technologies are required to generate electric power. Thermal energy harvesting using thermoelectric generator is one of energy harvesting technologies due to diverse advantages for new green technology. This paper presents a possibility of application of the thermoelectric generator's application in the direct exchange of waste solar energy into electrical power in road space. METHODS : To measure generated electric power of the thermoelectric generator, data logger was adopted as function of experimental factors such as using cooling sink, connection methods etc. Also, the thermoelectric generator、s behavior at low ambient temperature was investigated as measurement of output voltage vs. elapsed times. RESULTS : A few temperature difference between top an bottom of the thermoelectric generator is generated electric voltage. Components of an electrical circuit can be connected in various ways. The two simplest of these are called series and parallel and occur so open. Series shows slightly better performance in this study. An installation of cooling sink in the thermoelectric generator system was enhanced the output of power voltage. CONCLUSIONS : In this paper, a basic concepts of thermoelectric power generation is presented and applications of the thermoelectric generator to waste solar energy in road is estimated for green energy harvesting technology. The possibility of usage of thermoelectric technology for road facilities was found under the ambient thermal gradient between two surfaces of the thermoelectric module. An experiment results provide a testimony of the feasibility of the proposed environmental energy harvesting technology on the road facilities.

태양정밀추적 알고리즘의 LabVIEW 적용 연구 (The Study on the Application of Accurate Solar Tracking Algorithm by using LabVIEW)

  • 오승진;김영민;이윤준;조일식;천원기
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.121-125
    • /
    • 2009
  • There have been many developed systems for harnessing the solar energy such as solar water heaters, solar thermal power systems, PV systems, daylighting and solar hydrogen systems. all of them are capable of reducing $CO_2$ emission. However, the efficiency of those systems which work without a solar tracker is lower. This paper is a step by step procedure for fabrication and a performance test of a solar tracking system. The system developed in this study consists of motion controllers, motor drives, step-motors, feedback devices and application. CdS sensors are introduced into the solar tracking system for playing a primary role in poor conditions for tracking due to a gear backlash and a strong wind. Mini-dish was used as a concentrator for collecting sun light. The solar position data, in terms of azimuth and elevation, sunrise and sunset times was compared with those of KASI(Korea Astronomy & Space Science Institute). The results presented in this article provide the high accuracy of the present system in solar tracking and indicate a potential for energy savings.

  • PDF

태양광발전, 태양열 급탕, 지열시스템의 신재생에너지설비 조합에 관한 LCC 분석 (Life Cycle Cost Analysis about Renewable Energy Facilities Combination of Photovoltaic system, Solar thermal system and Geothermal system)

  • 전상현;안장원;김원우;조승연
    • KIEAE Journal
    • /
    • 제12권1호
    • /
    • pp.105-112
    • /
    • 2012
  • When a building is planned and designed, the design should be able to minimize the cost during the whole life cycle of the building. This study has begun to analyze LCC about the alternative design which is applicable to renewable energy facility construction. It is reviewed domestic and foreign papers about the trend of LCC technology and it is determined the analytical method to analyze the LCC of renewable energy. Regarding the review of alternatives, it is chosen the three alternatives which are able to designed combing the renewable energy facilities and it is performed the LCC analysis about each alternative. Alternative 1 is Photovoltaic + Solar Thermal + Photovoltaic /Wind Power, Alternative 2 is Geothermal + Photovoltaic, and Alternative 3 is Photovoltaic + Solar Thermal. The LCC analysis is present value method, its analytical period is 40 years and it is applied 3.2% of real discount rate. As a result, it is proved that Alternative 1 and Alternative 3 are not able to collectible the early investment cost during the analytical period and Alternative 2 is analyzed that its pay-back period of early investment cost is about 31 years. As the final outcome of this study on case analysis, it is more advantageous to use the combination of Geothermal and Photovoltaic energy than to use the other combination in LCC aspect.

국내 직달일사량 자원 분석 (Analysis of Direct Normal Insolation Resources in Korea)

  • 조덕기;윤창열;김광득;강용혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.130.1-130.1
    • /
    • 2011
  • Since the direct normal insolation is a main factor for designing any solar thermal power system, it is necessary to evaluate its characteristics all over the country. We have begun collecting direct normal insolation data since December 1992 at 16 different locations and considerable effort has been made for constructing a standard value from measured data at each station. KIER(Korea Institute of Energy Research)'s new data will be extensively used by solar thermal concentrating system users or designers as well as by research institutes. From the results, we can conclude that 1) Yearly mean $2.67kWh/m^2/day$ of the all day's direct normal insolation was evaluated for all days all over the 16 areas in Korea. 2) All day's direct normal insolation of spring and summer were $2.91kWh/m^2/day$ and $2.23kWh/m^2/day$, and for fall and winter their values were $2.78kWh/m^2/day$ and $2.77kWh/m^2/day$ respectively. So, spring, fall and winter were higher, and summer was lower than the yearly mean value.

  • PDF

농촌 마을회관 제로에너지 건축물 구축을 위한 에너지 성능 분석 연구 - 충남 태안군 정죽4리 마을회관을 중심으로 - (A study on the analysis of energy performance for zero-energy building of rural village hall - Focused on the Jung Juk 4-le village hall -)

  • 박미란;최정만;이정훈
    • 한국농촌건축학회논문집
    • /
    • 제20권4호
    • /
    • pp.1-8
    • /
    • 2018
  • In this study, we survey the 2 buildings at the Central 1 and 8 buildings at the Central 2, which are divided by each climate region in the rural regions. Major heat loss factors are 47% loss of the outer shell including outer wall, roof, and bottom, 30% loss through window, and 23% loss through crevice wind. We analyze the energy simulation of ECO2 program to construct a zero energy building regarding village hall located in Jung Juk 4-le at Centeral 2. We simulate the primary energy requirement regarding village hall and the simulated results show the $265.3kWh/m^2{\cdot}a$ and it may estimate '2' energy efficiency grade. The energy requirement regarding village hall is the $183.2kWh/m^2{\cdot}a$ when the passive technology are applied in village hall. We research total amount of energy requirement in village hall when the passive and active technologies such as solar cell with 3kW and solar thermal with $20m^2$, geothermal power with 17.5kW. The simulated results show the improved energy efficiency certification grade with $1^{{+}{+}{+}}$ due to the reduced primary energy requirement with 73% when passive technology including 3kW of solar panel is applied and the energy independence rate is 54%, which is estimated to be 4th grade of zero energy buildings. The order of energy consumption are solar panel, solar thermal, and geothermal power under applied passive technology in the building. In order to expand the zero energy building, it is necessary to introduce the zero energy evaluation system in the rural region.